The product

Page 4: Global Advanced Technology Group

H2X Container System

Page 5: Global Advanced Technology Group

The patented H2X systemenables in the first place

the use of Methanol Water or Ethanol Water mixture.

It is applicable for all engines.

What does the H2X

system mean?

Page 6: Global Advanced Technology Group

* Engine unit Type Turbine 50 H2X

* Generator type 3.5 MW (Siemens Morelli Motors or Elin)

* Tank system Incl. Fuel pump

* Computerized control systems incl. GPS or GSM

* Tariff strategy

* Container modules (sound and heat insulated)

* Connection device for the net link

Components of the H2X Container

Page 7: Global Advanced Technology Group

A) The sequence of the erection for the

container begins with its base plate.

It is the floor of the container, a so called double floor, which contains all fixtures necessary for the erection of the turbine and the generator. This base plate with adequate fixtures enables a transportation with a fork lift.

These fixations are important, because they constitute a rigid connection to the container itself on one side, and on the other side guarantee a firm connection between the engine and the generator, thus enabling a smooth operation.

All supply pipes are also laid in the base plate for the fuel, the cables, the control system and the cable bus, thus protected.

The base plate is then covered. This cover serves as a protection for all pipes and cables and can be used as a floor.

Technical Description of the H2X Container

Page 8: Global Advanced Technology Group

B) The next step is to fix the Generator with the erection fixtures in the base plate.

The generator is a three-phase generator with a

power output of 3.5 MW (an increase of the

capacity is being considered). The tension is

between 4 and 6 KV. The possible number of

revolutions is at 1500 R/min.

Because of the high speed of the turbine, a

gear is placed between the generator and

the turbine.

Due to the reduction of the speed of the

turbine down to the permissible rotations of

the generator, the torque output increases.

Technical Description of the H2X Container

Page 9: Global Advanced Technology Group

C) The turbine being the power engine of the generator, is then erected.

The capacity of the turbine is appr. 5 000 PS/3 650 KW at a speed of appr. 20 000 R/min. The continuous output is 3 200 KW. The shaft to the gear operates on ceramic bearings. The pressure is indicated at 04 bar. The values of the waste gas reach a temperature of 390°C.

The injection system is manufactured by the company Bosch.

A gear is installed between the generator and the turbine, as already mentioned, to balance the different speed frequency of the 2 aggregates. This increases and strengthens the speed torque.At normal operation the turbine has a speed frequency of appr. 18 000 R/min

Technical Description of the H2X Container

Page 10: Global Advanced Technology Group

D) Near the mechanical erection devices installed

on the foundation, there is the fuel tank with a

capacity of appr. 40 000 litres. The fuel is a

methanol-water mixture or an ethanol-water

mixture. It is also possible to use natural gas.

E) The container consists of an insulated sound

absorbing outer shell, sandwich type of

dimensions L 12m B 2.75m H 3m. Exterior

coating according to wish of customer.

Technical Description of the H2X Container

Page 11: Global Advanced Technology Group

Technical Description of the drive unit Type Turbine 50 H2X

• Type turbine 50 H2X• Length 215 cm• Diameter 147 cm• Revolutions 18000 1/min• Pressure rate 04• Capacity 3650 KW• Temperature of waste gas appr. 390°C• Ball Bearing – Ceramic• Shaft alley – Sp. steel• Conductor equipment – Sp. cast iron• Injection system – H.2.X System• Casing – Special steel casting

Page 12: Global Advanced Technology Group

Fuel mixtures

• Methanol-Water mixture

• Ethanol-Water mixture• Natural gas

Current Generator Type 3.5 MW

• Continuous output – 3200 KW

• Nominal output – 3500 KVA• Voltage – 6 KV• Tension uniformity - +/- 1 per cent• Tension adjustment range - +/- 5 per cent• Frequency – 50 Hz• Rotation speed – 1500 1/min• Over speed• Insulation class – F• Radio interference suppression degree – N

Page 13: Global Advanced Technology Group

Tank system incl. fuel pump

• Out of Special steel

• Volume – 40 000 litres• Fuel pump – Type Bosch• Quantity sensor – Type Bosch• Exhauster• Fuel sensor

Computerized Control system incl. GPS or GSM

• Computer (LCU, LCD)

• Processor 1000 Hz• Display – 2x15“ TFT SXGA• Tension – 12 Volt• Radio facility • GSM or GPS• Control equipment H2X• Control generator Rate strategist• Rate strategist

Page 14: Global Advanced Technology Group

Container modules

• Casing – Steel frame

• Side walls – Sandwich type

Aluminium synthetic material

• Insulation

• Door – 1

• Ventilation – 1 / max. 100 m³/ H

• Deaeration – 1/ max. 100 m³ /H

• Lights – 2 neon strips

• Antenna – 1 suitable for SAT

• Hoisting device – 2 hoists on rail

Page 15: Global Advanced Technology Group

Turbine H2X System

Page 16: Global Advanced Technology Group

The construction of the H2X Turbine has been

specially conceived for the power plant container. The

advantage compared to already existing turbines

are also highlighted.

Page 17: Global Advanced Technology Group

2. Efficiency close to 70 % compared to other turbines at max. 45%

1. Half the weight compared to existing engines

3. One third in size of a conventional turbine

4. Fuel consumption reduced by 50% (150 litre/hourPower 5000 hp)

5. High quality materials guarantee a longer servicelife.

Advantages

Page 18: Global Advanced Technology Group

TURBINE H2X

Why is this engine so powerful?

The turbine H2X system is by nature so powerful.

The injection system HIGS, patented world wide,

and the special construction and conception of

the combustor chamber upon this turbine guarantee an

usually high power output.

Small and powerfulLow fuel consumptionClean and environmentally friendly combustion

Page 19: Global Advanced Technology Group

TURBINE H2X INJECTION SYSTEM

Explanation:

Through the patented HIGS Injection System, a new

generation of turbines has been born. The water fuel

mixture is injected into the combustor chamber under

a very high pressure( 173psi). This triggers the ignition

of the mixture through an ignition plug. An explosive

force arises. Compared to the one flame of the

conventional turbine, the H2X System experiences a

double power impact.

As a result the world wide protected H2X Turbine

1.) has a low fuel consumption2.) is very powerful

Page 20: Global Advanced Technology Group

TURBINE H2X compared to DIESEL ENGINE

A comparison between H2X and a Diesel engine reveals.

A Power Plant Container with the H2X System has the

following dimensions. L 12m, W 2,6 m, H 3 m. The weight

is approximately. 15 tons.

In a Power Plant Container with a Diesel Engine of the

same capacity, the Diesel Engine alone would weigh 30

to 35 tons, and measure a lenght of the 6 to 8 m.

Hence unsuitable for a container.

The turbine has a very low noise level (26 db).

In contrast is the diesel engine very noisy (over 100 db).

Page 21: Global Advanced Technology Group

ADVANTAGE OF THE INSTALLATION

** INSTALLATION:

The container is only connected to the net

coupling point. Following this points we

recommend our customers to lay the cables

underground. So damages due to storm,

hurricane or floods are impossible.

** CONSTRUCTION:

The only civil activity comprises the construction

of a concrete foundation slab, according to data

of the company. No supply roads and no

expensive high voltage over headlines are

needed.

** TRANSPORT:

On trucks, by ship, on trains and in some

countries, if necessary, by a helicopter.

Page 22: Global Advanced Technology Group

** INTERCONNECTION:

In the cities with more than one power container,

the demand for electricity is controlled by a rating

communication equipment. In case of a

breakdown of one container, the loss is

equalized by this equipment.

NO MORE BLACK OUT

** NOISE:To the construction of the container wall

which is isolated against head and

noise, the outside perceptible noise level

is very low therefore, 26 db.

** ENVIRONMENT:

Though the use of ethanol-water and methanol-

water mixture, there is no emission of pollutants

following combustion. This means that the power

plant container is clean and can be placed

anywhere, even in front of the house door.

Page 23: Global Advanced Technology Group

** INSTALLATION POSSIBILITIES

Military Areas

Residential Compounds

Hospital and Social Institutions

Harbor (Port Facilities )

Big Factories

Timber Industry

for all Communities

Page 24: Global Advanced Technology Group

PRODUCTION COSTS PER kW/H

Nuclear Power 22 Cent 440%

Caloric Power 18 Cent 360%

Hydroelectric

Power 14 Cent 280%

H2X Container 05 Cent 100%

Page 25: Global Advanced Technology Group

CONSTRUCTION COSTS PER kW/H

Nuclear Power Euro 3.100,-- 280%

Caloric Power Euro 2.100,-- 190%

Hydroelectric

Power Euro 4.400,-- 400%

H2X Container Euro 1.380,-- 100%

Page 26: Global Advanced Technology Group

PLANNING PERIOD UP TO INITIAL GENERATION OF ELECTRICITY

Nuclear Power 4 Years

Caloric Power 2-3 Years

Hydroelectric 3-4 Years

Power

H2X Container 8-12 MONTH

Page 27: Global Advanced Technology Group

COMPARISON

DIESELENGINE

TURBINE CONVENTIONALTURBINE H2X

WEIGHT

Diesel Engine 30.000 Kg

Turbine conventional 4.500 Kg

Turbine H2X 2.100 Kg

Page 28: Global Advanced Technology Group

COMPARISON

DIESELENGINE

TURBINE CONVENTIONALTURBINE H2X

EFFICIENCY

Diesel Engine 47 %

Turbine conventional 48 %

Turbine H2X 70 %

Page 29: Global Advanced Technology Group

COMPARISON

DIESELENGINE

TURBINE CONVENTIONALTURBINE H2X

FUELCONSUMPTION

Diesel Engine 770 Liter / h

Turbine conventional 450 Liter / h

Turbine H2X 150 Liter / h

Page 30: Global Advanced Technology Group

COMPARISON

DIESELENGINE

TURBINE CONVENTIONALTURBINE H2X

SERVICE

Diesel Engine 1.000 - 1.500 /h

Turbine conventional 2.000 - 2.500 /h

Turbine H2X 4.000 - 4.500 /hafter 2.250 hrs. Inspection of Plant through GPS

and the Control System (total check up )

Page 31: Global Advanced Technology Group

COMPARISON

DIESELENGINE

TURBINE CONVENTIONALTURBINE H2X

SHUTDOWN TIME DURING SERVICE

Diesel Engine 24 - 48 /h

Turbine conventional 12 - 18 /h

Turbine H2X 2 - 3 /h

Page 32: Global Advanced Technology Group

COMPARISON

DIESELENGINE

TURBINE CONVENTIONALTURBINE H2X

SERVICE COSTS

Diesel Engine 10.000 - 200.000,-- Euro

Turbine conventional 10.000 - 150.000,-- Euro

Turbine H2X 4.000 - 5.000,-- Euro