Top Banner
................................ IN-LINE TILE ® , SLATE & RIDGE VENTILATORS CI/SfB (47) Uniclass Pr_30_59_29 July 2018
6

Glidevale In-line, Slate & Ridge Ventilators · slate and ridge ventilators are designed to ventilate through the roof slope and form an integral part of the roof covering. The slate

Sep 28, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Glidevale In-line, Slate & Ridge Ventilators · slate and ridge ventilators are designed to ventilate through the roof slope and form an integral part of the roof covering. The slate

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

IN-LINE TILE®, SLATE & RIDGE VENTILATORS

CI/SfB (47) Uniclass Pr_30_59_29July 2018

Page 2: Glidevale In-line, Slate & Ridge Ventilators · slate and ridge ventilators are designed to ventilate through the roof slope and form an integral part of the roof covering. The slate

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Glidevale profile dedicated In-line tileslate and ridge ventilators are designed

to ventilate through the roof slope and forman integral part of the roof covering.

The slate and tile ventilators can be used atlow level or high level where the roofconstruction does not allow eaves or ridgeventilators to be used such as wherecompartment walls or fire break wallsobstruct airflow. They are also used incomplex roof shapes where effective cross-ventilation is not possible.

The In-line ridge ventilators are used atintervals with proprietary ridge tiles, onbedded and many dry ridge systems. Thewhole In-line range can also be used as soilvent pipe or mechanical extract terminalswith separately supplied accessories.

Composition, ManufactureManufactured from ABS and polypropylenematerial for a high quality finish and robustconstruction. All exposed surfaces arecoated with a durable water based colourblended surface treatment. This surfacetreatment has been used on all GlidevaleVentilators for over 20 years, and after thistime shows only a marginal lightening ofshade which is usually counteracted by theeffect of atmospheric pollution on the roofcovering itself. All tile and ridge ventilatorshave silica sand entrained in the multi coatcoating. Slate ventilators have a smoothfinish.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

● Profile matched and colour blended in with adjacent slates, tiles and ridges as standard, making the ventilators almost indiscernible once installed.

● Can be installed wherever they are required as part of the normal roofing process.

● Driving rain and deluge rain resistance demonstrated by test data.

● High nett free ventilation area and low airflow resistance allow for an optimum spacing to avoid stagnant air pockets.

● Integral or supplied extension sleeves ensure a clear air path from the roof void to the outside to meet the design requirements of BS 5250.

● Integral 4mm large insect ingress screen.

● An unrivalled range of slate, tile & ridge profiles plus a colour matching service means that Glidevale offer an excellent service for heritage projects and listed buildings.

● Designed and developed under BS EN ISO 9001.

BENEFITS

2

Page 3: Glidevale In-line, Slate & Ridge Ventilators · slate and ridge ventilators are designed to ventilate through the roof slope and form an integral part of the roof covering. The slate

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IN-LINE TILE & SLATE VENTILATORS

Redland 50/DoubleRoman tiles

Redland Regent tiles

Redland MiniStonewold andStonewold Mk IItiles

Marley MendipDouble Pantiles

Plain tiles (otheruniversal In-line tileand slate ventilatorsavailable)

Redland Cambrianslate

600 x 300mm slate

Universal In-lineslate

Examples of ventilators, with tiles/slates forwhich they are designed to be compatible

AppearanceIn-line Tile & Slate Ventilators are availablefor use with the roof tile manufacturers’specific profiles listed on the back page,colour-matched to any of the standardcolours for that tile.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Other profiles available on request (aselection of universal profiles to fit across arange of manufacturers is also available,see Universal In-line tile and slate ventilatorrange brochure).

3

Page 4: Glidevale In-line, Slate & Ridge Ventilators · slate and ridge ventilators are designed to ventilate through the roof slope and form an integral part of the roof covering. The slate

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Interlocking Tile & Slate VentilatorsGuaranteed actual nett free ventilation area:10 000mm2

Spacing centres to achieve ventilation area of5000mm2/m: 2.0m10 000mm2/m: 1.0mMinimum pitch: 22.5° - 60° unlessotherwise stated

Airflow resistance when used asSVP/extract terminal:54m3/hr (15 litres/sec) 10 Pa108m3/hr (30 litres/sec) 42 Pa216m3/hr (60 litres/sec) 162 Pa

Plain Tile VentilatorsGuaranteed actual nett free ventilation area:7500mm2

Spacing centres to achieve ventilation area of5000mm2/m: 1.5m10 000mm2/m: 0.75mMinimum pitch: 35°- 60°

Airflow resistance when used asSVP/extract terminal 54m3/hr (15 litres/sec) 12 Pa108m3/hr (30 litres/sec) 37 Pa216m3/hr (60 litres/sec) 127 Pa

Roof ventilation: profiled interlocking Tile Ventilator, insulation at rafters

Rigid insulation board Rigid insulation board

Underlayprotector

Underlayprotector

Protect VP400 Plus LRunderlay

Roof ventilation: plain Tile Ventilator, insulation at rafters

Plain Tile Ventilator

SVP/extract terminal: flat interlocking TileVentilator

Soil Universal Pipe Adaptor

SVP/extract terminal: plain Tile Ventilator

Flexi Pipe (must be insulated inunheated roof space)

Flexi Pipe (for soil vent orextract terminal)

Soil UniversalPipe Adaptor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specification clausesVentilation of roof spaceProvide low level/highlevel roof spaceventilation by means ofGlidevale In-line Tile/SlateVentilators with integral4mm large insect screen.Size/profile ......., colour.......... (matched to theroof covering), and to beinstalled complete withGlidevale UnderlayOpening Protectors.Install at ...... m centresas shown on drawings toprovide ventilation areaequivalent to ........mm2/min accordance withBuilding RegulationsApproved Document C22004 amd 2010 & 2013and BS 5250: 2011 andA1: 2016. Fix inaccordance withmanufacturer’sinstructions.

SVP/mechanical extractterminalsSoil vent pipestacks/mechanicalextract ducts to beterminated at the roofslope by means ofGlidevale In-line Tile/SlateVentilators with integral4mm large insect screen.Size/profile ....., colour...... (matched to the roofcovering), and to beinstalled with GlidevaleUnderlay OpeningProtector, Soil UniversalAdaptor and Flexi Pipe.Install where shown ondrawings and fix inaccordance withmanufacturer’sinstructions. All joints andconnections to be airtightin accordance withBuilding RegulationsApproved Document H 2010, and all pipesand ducts in the roofspace to be insulated.

4

Page 5: Glidevale In-line, Slate & Ridge Ventilators · slate and ridge ventilators are designed to ventilate through the roof slope and form an integral part of the roof covering. The slate

BENEFITS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

IN-LINE RIDGE VENTILATORS

G64 Angle Ridge VentilatorRedland Universal Angle ●

G51 Half Round Ridge VentilatorRedland Half Round ●

Russell Half Round ●

Sandtoft Half RoundWeatherwell Half RoundRoadstone Half Round ●

Scott Half Round ●

Scotcem Half RoundQuinn Half Round

G53 Segmental Ridge VentilatorMarley Segmental ●Sandtoft SegmentalMorrissey Segmental

G54 Angle Ridge VentilatorMarley Modern Angle ●

G52 Half Round Ridge VentilatorEternit Clay Half RoundRedbank 200mm Half RoundKeymer Half RoundGoxhill Clay Half Round ●

G103 Legged Angle Ridge VentilatorSandtoft Legged Angle ●

Richmond Universal Angle ●

G501 Ridge Pipe Adaptor(supplied separately)

G52 Ridge VentilatorUsed as soil vent/mechanical extract terminal

Flexi Pipe (must be insulated inunheated roof space)

Protect VP400Plus LR Underlay

Detachable ExtensionSleeve

System compatible with:● Russell/Scott Dry Ridge ● Redland Dry Vent Ridge ● Marley Dry Fix Ridge ● Goxhill Ventilated Dry Ridge ● Sandtoft Ventilated Dry Ridge

Company names and productdescriptions are the registered trade marks of the relevantmanufacturer.

G501 Ridge PipeAdaptor

Flexi Pipe (for soil vent orextract terminal)

PerformanceGuaranteed actual nett free ventilation area: 12 000mm2.Spacing to achieve 5000mm2/m: 2.4m.Maximum pitch when used with dry ridge systems: G51 45°,G53 40°, G54 40°, G64 45°.

Airflow resistance when used as SVP/extract terminals

Pipe diameter100mm 125mm

54m3/h (15 litres/sec) 2Pa 3Pa108m3/h (30 litres/sec) 8Pa 10Pa216m3/h (60 litres/sec) 29Pa 37Pa

Specification clausesVentilation of roof spaceProvide high level roofspace ventilation bymeans of GlidevaleG51/G52/G53/G54/G64Ridge Ventilators withintegral 4mm large insectscreen. Profile ......,colour......... (matched toridge tiles), withdetachable ExtensionSleeves. Install at 2.4mcentres to provideventilation areaequivalent to5000mm2/m inaccordance with BuildingRegulations ApprovedDocument C2 2004 amd2010 & 2013 and BS 5250: 2011. Fix inaccordance withmanufacturer’sinstructions.

SVP/mechanical extractterminalsSoil vent pipe stacks/Mechanical extract ductsto be terminated at theridge by means ofGlidevale G51/G52/G53/G54/G64 RidgeVentilators with integral4mm large insect screen.Profile ...., colour ......(matched to ridge tiles),and to be installedcomplete with RidgePipe Adaptor and FlexiPipe. Install where shownon drawings and fix inaccordance withmanufacturer’sinstructions. All joints andconnections to be airtightin accordance withBuilding RegulationsApproved Document H2010, and all pipes andducts in the roof spaceto be insulated.

Hawkins Half RoundAnchor Half RoundCondron Half RoundBallymena Half Round

DetachableExtensionSleeve

DescriptionGlidevale In-line ridge ventilators have been designed toprovide an aesthetic and unobtrusive solution to roofventilation at ridge level.

● Continuous, clean, unbroken ridge line with colour-match option.

● 4mm large insect screen.

● Integral stainless steel fixing wires and end sockets restrain the ridge vent for maximum wind uplift resistance.

● Driving rain resistant - by discharging wind-driven rain via baffles concealed below the ridge surface.

● Ventilation slots on each side of vent, making them indistinguishable from standard ridge tiles once installed.

● Condensation grooves on upper surface which divert any condensate which may form on the underside of the vent.

● Nail holes - making it easy to fit.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Page 6: Glidevale In-line, Slate & Ridge Ventilators · slate and ridge ventilators are designed to ventilate through the roof slope and form an integral part of the roof covering. The slate

STANDARD PROFILES

ForticreteGemini Mk 1ViscountStone Slate457mm x 305mmHardrow SlateMinislate Mk IICondronFlatDouble PantileMini Slate (Single Baseplate)

Lagan FlatMarley Eternit Anglia *Bold RollDominoDouble RomanEdgemereLudlow MajorLudlow PlusMarley Melbourn (Ownbrand Only)

MarquessMendipModernMonarch *SymphonyWessexMcLaughlin FoyletileMorrissey MilfordRockford Double PantileQuinn Building ProductsCarnmoreLocherneRathmore - DevenishWesternRedland4950 Double RomanCaledonianCambrian *Fenland Pantile / Norfolk Pantile *

GroveburyMini StonewoldRegentRenownRichmond 10 / Saxon 10Richmond/SaxonStonewold MKIIRoadstone CausewayDerrie MKIIDouble Roman (old)Flat - was Roadstone Stonewold

Mini SlateSeville

SL8Slate TileSpanish RollRussellArgyllCheviotDerwentDouble RomanGalloway - Lothian Moray - Polden

GrampianPennineWeinerberger Sandtoft20/20 - New20/20 - Old styleActuaBold RollBritlock *Calderdale (New)Calderdale EdgeCassiusCounty Pantile *DanumDouble PantileDouble RomanEuropaFlemishFlemish 401 AramantOld English Pantile *LindumNeo PantileOld Hollow 451OlympusPennine Slate 480mm x 280mm

Pennine Slate 480mm x 420mm

RiviusShire PantileStandard PatternScotcemCairngormForthPentlandNorthstone CausewayDerrie MKIDerrie MKIIDonardGalloway-LothianSevilleSlemish MKIIPlain Tiles *ForticreteDreadnaughtEternitHawkinsLangley of LondonMarleyRedlandRoadstoneRosemary

RusellSandtoft/GoxhillNorthstoneTudorUniversal400mm x 400mm Slate (with mock joint and smooth finish)

500mm x 250mm Slate riven finish

500mm x 250mm Slate smooth finish

600mm x 300mm Slate riven finish

600mm x 300mm Slate smooth finish

Bitumen Shingle 12°Bitumen Shingle 20°Slate Soaker - GV11 ALL SIZES

Universal Soaker Slate Vent

Burlington510mm x 455mm405mm x 305mm610mm x 305mm510mm x 355mm510mm x 305mm Natural Slate

Aggregate Industries450mm x 450mm406mm x 375mmConservation Slate450mm x 400mmCotswold Reconstituted Slate

500mm x 375mmMoordale ReconstitutedSlate

Bradstone Crofters Slate

* These tiles requiremultiple baseplates toensure a weatherproofinstallation.

Ventilators designed to suitthe tile manufacturers profiles listed here areavailable in eachmanufacturer’s range ofcolours. For other profilesand colours please contactour Technical Department.

Company names andproduct descriptions arethe registered trade marksof the relevantmanufacturer.

GLIDEVALE 2 Brooklands Road, Sale, Cheshire M33 3SS Tel: 0161 905 5700 Fax: 0161 905 2085Email: [email protected] Web: www.glidevale.com

Glidevale maintains a policy of continuous development and reserves the right to amend product specifications without notice.

A division of Building Product Design Ltd. Company Registration No; 3944123

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .910092 July 2018 4600

Stockist’s stamp

Composition and manufactureAll Glidevale In-line ventilators aremanufactured from upvc, polypropylene orABS for a consistently high quality finishand long lasting construction. Withexcellent weathering characteristicsGlidevale ventilators will complement anyroof for many years to come.

Building RegulationsAll Glidevale In-line ventilators can be usedto comply with:

Roofspace ventilation: Building Regulations Approved Document C,BS 5250 and BS 5534.

Soil vent pipes: Building Regulations Approved Document H.

Mechanical ventilator terminal: Building Regulations Approved Document F.

Glidevale’s range of profile dedicated In-linetile, slate and ridge ventilators are at thecore of an unrivalled capability. Whetheryou want to cover the widest number ofapplications with the fewest number ofreferences or you need to match the exactprofile and colour for a heritage projectGlidevale have the solution. Glidevale is the‘one stop shop’ for roof ventilationsolutions.

ISO 9001 OHSAS 18001

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .