fluid sensors and diagnostic systems bus, identification and control systems position sensors and object recognition www.ifm.com/gb/connect Connection technology Get connected. ifm connection technology.
fluid sensors and diagnostic
systems
bus, identification
and control systems
position sensors
and objectrecognitionw
ww
.ifm
.co
m/g
b/c
on
nec
tC
on
nec
tio
n t
ech
no
log
y
Get connected.ifm connection technology.
Without tools:
Vibration protec-tion and maximumingress resistancewhen hand-tight.The end stop pre-vents an overtight-ening.
The right choice forreliable connections.
Vibration protection with end stop
Excessive force impossible! Due to the
special installation of a mechanical end
stop the O-ring is always correctly com-
pressed and so permanently maintains its
sealing function.
With vibration protection! The saw-tooth
type contour ensures that the nut is secure-
ly positioned. During mounting the nut
slides easily over the flat edge. So safe
sealing is achieved during manual mount-
ing. The steep edge of the contour pro -
tects the nut against unintentional loosen-
ing. The connector remains securely posi-
tioned on the unit even in case of extreme
vibration and impacts.
Clearly visible! Novel design and a trans-
parent black housing ensure that even in
bright lighting conditions the LEDs are
more clearly visible than with the clear
transparent versions. This is an important
prerequisite to keep an eye on the plant
process all the time and to be able to act
quickly in case of problems.
ecolink M12.
Testedto extremes:
The temperatureshock test simu-lates CIP processesand verifies theageing resistance.
2
The specialists! High-quality materials
enable use in special applications – from
factory automation to machine-tool indus-
try. The new ecolink M12 connectors are
especially resistant to oils and coolants
and ensure high machine uptime.
Sealed:The innovative sealing conceptprovides the high protectionratings IP 67 / IP 68 / IP 69K forM12 and even M8 connectors.
Held in place:The saw-tooth type vibrationprotection ensures that the nutdoes not become loose uninten-tionally in case of shock andvibration.
By hand:Easy to install and removemanually. The integrated endstop protects the O-ring froman excessive compression.
Visible:Versions in a transparent blackhousing for an optimum visibilityof the LED even in bright lightingconditions.
Standardised:The connection technologymeets the M8 and M12 standardEN 61076.
Special:In addition to the standard seriesfor industrial applications youcan choose special versions adapt-ed to your application.
The new quality standardin connection technology.
ecolink M8:
For the first timethe innovative
profiled sealingring also provides
the high protec-tion ratings IP 67 /
IP 68 / IP 69K forM8 connectors.
For demanding applications: So far only
M12 connectors could be used in difficult
applications. For the first time the new
ecolink M8 series provides all advantages
of the ecolink M12 series for standardised
M8 connectors (EN 61076).
Without tools: The innovative profiled
sealing ring seals radially and axially,
guaranteeing a high protection rating. No
tools needed for installation and removal.
Permanently ingress-resistant: The asym-
metrically acting vibration protection
holds the nut tight in its position, guaran-
teeing an optimum and permanent seal.
High quality standard: High-quality mate-
rials especially adapted to the application
and intensive monitoring during and after
production guarantee maximum quality
standards.
Now new: ecolink M8.
An eye on theplant process:
Even in brightlighting conditionsthe LEDs are clear-ly visible in thetransparent blackversion.
3
The right choice forreliable connections.
ecolink EVT – resistant to chemicalinfluence and temperature shocks.
ecolink EVC – the standard series forindustrial applications. Resistant to oilsand greases.
4
For industrial applications:High-quality materials adaptedto the requirements in industrialenvironments. Largely resistantto oils and greases.
Page 6 Wirable plugs andsockets
Page 7-8 Sockets with cablePage 9-14 JumpersPage 15 Splitter boxes M12Page 16 Splitter boxes M8
For hygienic and wet areas:Housings and cables made ofPVC, gold contacts and high-grade stainless steel nuts are thebest prerequisite for a long life inthe special applications of thehygienic and food industry.
Page 17 Sockets with cablePage 18-19 Jumpers
Page 20 Sockets with cable
For oils and coolants:With PUR housing, cable with fullPUR sheath, Viton seals and goldcontacts, these products set newstandards for the harsh operatingconditions of the machine toolindustry.
Page 22 Sockets with cable
For electromagnetic fields:In welding equipment weld-slagresistant, halogen-free PURcables and coupling nuts withspecial coating provide a maxi-mum protection from weldspatter. A special polyester fleecestrip foil in the cable ensures along life even in case of hightorsional stress, for example inrobot arms.
Page 23 Sockets with cable
For hazardous areas:The connectors comply withthe strict requirements of thestandard and are therefore al-lowed for use in ATEX areas ofthe categories 2D, 3D and 3G.Approval body DEKRA EXAM,notified in Germany, has type-tested and certified the connec-tors. The EC type examinationcertificate for components isvalid in all EU countries.
Adapted to yourapplication conditions.
ecolink EVM – the robust connectionfor sensors in harsh environments.
5
Page 21 Sockets with cable
For sensors in robust applications:The saw tooth contoured vibra-tion protection secures againststrong shocks and vibrations.The high protection rating IP 67 /IP 68 / IP 69K, the wide tempe -rature range of -40...90 °C as wellas high-quality housing materials(high-grade stainless steel, TPU)ensure a long-term safe connec-tion in harsh environments suchas salty moisture, oil, grease andcoolants.
You can find the new generationof ifm connection technology underthis product logo:
ecolink EVW – thanks to a non-stickcoating resistant to weld spatter.
6
For industrialapplications
Type Pinassignment
E11504
Order no.
Plug M12 4-pole · 5-pole
Currentrating
[A]
Operatingtemperature
[°C]
Protec-tion
Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
4 -25...100 IP 68 PA CuZn/Ni 0.6...0.7
4 -40...85 IP 65 PA PA –
7.5 -25...90 IP 65 CuZn/Ni CuZn/Ni –
3 -40...100 IP 67 PBT PBT –
3
1
4
2
E115063
1
4
2
5
E11508
Socket M12 4-pole · 5-pole
4
2
3
1
E10137
Socket M18 4-pole
2
4
3
1
E70142
Socket RD24 7-pole
6
4
1
52
3
E10448
Socket M23 12-pole · 19-pole
10
2
1 8
12
4 5
7
11
9
3 6
E10887102
1
8
12
4
5 7
11
93
6
18
17
16
15
19
13
14
E115114
2
3
1
5
Type Pinassignment
E11505
Order no. Wiring diagram /Wire specification
Plug M12 4-pole · 5-pole
3
1
4
2
E115073
1
4
2
5
E11509
Socket M12 4-pole · 5-pole
4
2
3
1
E10013
Socket M18 4-pole
2
4
3
1
E11043
Socket RD24 7-pole
6
4
1
52
3
E115104
2
3
1
E10447
Socket M23 12-pole · 19-pole
10
2
1 8
12
4 5
7
11
9
3 6
E10886102
1
8
12
4
5 7
11
93
6
18
17
16
15
19
13
14
E115124
2
3
1
5
Wirable plugs and socketsM12, M18, M23, RD24
Technical data
0.75 mm2, Ø 4...6 mm
0.75 mm2, Ø 4...6 mm
0.75 mm2, Ø 6...8 mm
1 mm2, Ø 10...14 mm
2.5 mm2, Ø 6...9.5 mm
Plug
PIN
Connection
screw terminals
selectable
Socket
PIN
Connection
soldering
selectable
Socket
PIN
Connection
screw terminals
selectable
Socket
PIN
Connection
screw terminals
selectable
Operating voltage /Operating voltage with LED
[V]
Type
250 AC, 300 DC / 10...30 DC
250 AC/DC
10...30 DC
250 AC, 300 DC
M12 4-pole
M18
4 -40...85 IP 65 PA PA –125 AC/DCM12 5-pole
M23
RD24
with LED
LED: signals yellow, operating voltage green
Socket
PIN
Connection
screw terminals
selectable
Type Pinassignment
Cable
[m]
LEDs
Socket M8 3-pole
Currentrating
[A]
Operatingtemperature
[°C]
Protection Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
3 -25...85 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.3...0.5
3 -25...85 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.3...0.5
4 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.6...1.5
4 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.6...1.5
Order no. Wiring diagram /Wire specification
M8, M12 sockets
Technical data
PUR cable black5 x 0.34 mm2, Ø 4.9 mm
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
5
GY
Socket M8 4-pole
2
Socket M12 4-pole ecolink
–
5 –
10 –
2
4
2
3
1
4
2
3
1
4
2
3
1
–
5 –
10 –
2 •
5 •
10 •
2
Socket M12 5-pole ecolink
–
5 –
10 –
2 –
5 –
10 –
Operating voltage /Operat. voltage with LED
[V]
Type
50 AC, 60 DC / 10...36 DC
50 AC, 60 DC
250 AC, 300 DC / 10...36 DC
36 DC
M8 3-pole
M8 4-pole
M12 4-pole
M12 5-pole
PUR cable black3 x 0.34 mm2, Ø 5 mm3 x 0.25 mm2, Ø 3.7 mm
LED: signal yellow, operating voltage green
LED: signals yellow, operating voltage green
PUR cable black4 x 0.25 mm2, Ø 3.7 mm
PUR cable black4 x 0.34 mm2, Ø 4.9 mm
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
2
3
1
5
4
2
3
1
5
7
EVC001
EVC002
EVC003
EVC004
EVC005
EVC006
EVC007
EVC008
EVC009
EVC070
EVC071
EVC072
EVC073
EVC074
EVC075
ecolink. The new quality standard
in connection technology.
2 –
5 –
10 –
24
13
–
5 –
10 –
EVC141
EVC142
EVC143
EVC144
EVC145
EVC146
2 •
5 •
10 •
EVC147
EVC148
EVC149
4
13
4
13
2
13
4 2
–
5 –
10 –
2 –
5 –
10 –
EVC150
EVC151
EVC152
EVC153
EVC154
EVC15513
4 2
8
For industrialapplications
Type Pinassignment
5
Cable
[m]
Socket M12 8-pole
Currentrating
[A]
Operatingtemperature
[°C]
Protec-tion
Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
3 -25...80 IP 68 PUR CuZn/Ni 0.7...0.9
3 -25...90 IP 68 PUR CuZn/Ni –
8 -25...80 IP 67 PUR CuZn/Ni –
8 -25...80 IP 67 PUR CuZn/Ni –
6
2
4
1
37
5
8
10
Order no.
–
E11311
2
5
E11231
E11232
Wiring diagram /Wire specification
M12, M16, M23 sockets
Technical data
PUR cable black8 x 0.25 mm2, Ø 6.2 mm
PUR cable black8 x 0.5 mm2 and 3 x 1 mm2, Ø 9.3 mm
PUR cable black16 x 0.5 mm2 and 3 x 1 mm2, Ø 11.6 mm
PUR cable black8 x 0.34 mm2 and 2 x 0.75 mm2, Ø 9.1 mm
5
Socket M16 14-pole, 8-wire
L AMUN
OP
EGRS
TJ C
10
E11226
E11227
5
Socket M23 12-pole
10
15
5
10
15
E11736
E11737
E11738
E11739
E11740
E11741
5
Socket M23 19-pole
102
1
8
12
4
5 7
11
93
6
18
17
16
15
19
13
1410
15
5
10
15
E11742
E11743
E11744
E11745
E11746
E11747
M12 8-pole
M16 8-pole
M23 12-pole
M23 19-pole
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
5
GY
6
PK
7
VT
8
OG
Socket
PIN
Colours
A
BN
C
WHGN
E
GYPK
J
GN
L
BU
N
GNBN
O
RDBU
P
WH
S
GY
T
YE
Socket
PIN
Colours
1
VT
2
RD
3
GY
4
RDBU
5
GN
6
BU
7
GYPK
8
WHGN
9
WHYE
10
WHGY
11
BK
12
YEGN
Socket
PIN
Colours
1
WH
2
GN
3
YE
4
GY
5
GYPK
6
RDBU
7
WHGN
8
BNGN
9
BU
10
BU
11
BN
12
YEGN
PIN
Colours
13
YEBN
14
BNGN
15
WH
16
YE
17
PK
18
GYBN
19
BN
Operating voltage /Operating voltage with LED
[V]
Type
30 AC, 36 DC
30 DC
250 AC/DC
160 AC/DC
10
2
1 8
12
4 5
7
11
9
3 6
6
2
4
1
37
5
8
102
1
8
12
4
5 7
11
93
6
18
17
16
15
19
13
14
10
2
1 8
12
4 5
7
11
9
3 6
9
Type Pinassignment
plug
Pinassignment
socket
Cable
[m]
LEDs
Plug M8 3-pole · Socket M8 3-pole
Order no. Wiring diagram /Wire specification
Jumpers
PUR cable black3 x 0.25 mm2, Ø 3.7 mm
PUR cable black3 x 0.25 mm2, Ø 3.7 mm
PUR cable black3 x 0.25 mm2, Ø 3.7 mm
Plug M8 3-pole · Socket M8 4-pole
Plug M8 4-pole · Socket M8 3-pole
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
ProtectionType Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
50 AC, 60 DC 3 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.3...0.5
50 AC, 60 DC 3 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.3...0.5
50 AC, 75 DC / 10...36 DC 3 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.3...0.5
50 AC, 60 DC 3 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.3...0.5
Technical data
Plug M8 3-pole
Plug M8 4-pole
Socket M8 3-pole
Socket M8 4-pole
Socket
Plug
PIN
1
1
BN
2 3
3 BU
4
4
BK
Socket
PIN
1
1
BN
3 4
3 BU
4 BK
Plug
Socket
Plug
PIN
1
1
BN
3
2
3 BU
4
4 BK
LED: signal yellow, operating voltage green
0.3
4
31
–
0.6 –
1 –
–
–
–
EVC265
EVC266
EVC267
2 –
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
–
EVC268
EVC269
EVC275
EVC276
EVC277
–
–
EVC278
EVC279
4
13
4
31
4
13
4
31
4
13
•
•
•
EVC280
EVC281
EVC282
•
•
EVC283
EVC284
0.3
0.6
1
2
5
0.3
0.6
1
2
5
4
31
4
31
–
–
–
–
–
–
EVC270
EVC271
EVC272
–
–
EVC273
EVC274
EVC260
EVC261
EVC262
–
–
EVC263
EVC264
13
4 2
13
4 2
0.3
0.6
1
2
5
0.3
0.6
1
2
5
–
–
–
–
–
–
EVC305
EVC306
EVC307
–
–
EVC308
EVC309
EVC315
EVC316
EVC317
–
–
EVC318
EVC319
4
31
2
4
31
2
4
13
4
13
ecolink. The new quality standard
in connection technology.
10
For industrialapplications
PUR cable black4 x 0.25 mm2, Ø 3.7 mm
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
ProtectionType Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
50 AC, 60 DC 3 -25...90 IP 68 PUR CuZn/Ni 0.3...0.5
250 AC, 300 DC 4 -25...85 IP 68 PUR CuZn/Ni 0.7...0.9
60 AC, 75 DC / 10...30 DC 3 -25...85 IP 68 PUR CuZn/Ni 0.6...0.7
Technical data
Plug M8 4-pole
Plug M12 3-pole
Socket M8 3-pole
50 AC, 60 DC 3 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.3...0.5Socket M8 4-pole1)
60 AC, 75 DC 3 -25...85 IP 68 PUR CuZn/Ni 0.6...0.7Socket M8 4-pole
Type Pinassignment
plug
Pinassignment
socket
Cable
[m]
LEDs
Plug M8 4-pole · Socket M8 4-pole ecolink
Order no.
Jumpers
Plug M12 3-pole · Socket M8 3-pole
3
1
4
–
–
–
–
–
–
E11376
E11377
E11378
–
–
E11379
E11380
E11381
E11382
E11383
–
–
E11384
E11385
4
13
3
1
4
4
13
3
1
4
3
1
4
3
1
4
4
13
•
•
•
E11386
E11387
E11388
•
•
E11389
E11390
Plug M12 3-pole · Socket M8 4-pole
–
–
–
–
–
–
E11391
E11392
E11393
–
–
E11394
E11395
E11396
E11397
E11398
–
–
E11399
E11400
PUR cable black3 x 0.25 mm2, Ø 4.1 mm
Socket
PIN
1
1
BN
3 4
3 BU
4 BK
Plug
PUR cable black3 x 0.25 mm2, Ø 4.1 mm
Socket
Plug
PIN
1
1
BN
2 3
3 BU
4
4
BK
Socket
Plug
PIN
1
1
BN
2 3
2 WH
3 BU
4
4
BK
Wiring diagram /Wire specification
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
13
4 2
13
4 2
LED: signal yellow, operating voltage green
4
31
2
–
–
–
4
31
2
–
–
–
EVC310
EVC311
EVC312
–
–
EVC313
EVC314
EVC300
EVC301
EVC302
–
–
EVC303
EVC304
0.3
0.6
1
2
5
0.3
0.6
1
2
5
13
4 2
13
4 2
1)ecolink
11
Type Pinassignment
plug
Pinassignment
socket
Cable
[m]
LEDs
Plug M12 4-pole · Socket M8 4-pole
3
1
4
2
–
–
–
–
–
–
Order no.
E11441
E11442
E11210
–
–
E11211
E11445
E11446
E11447
E11212
–
–
E11213
E11450
Jumpers
13
4 2
3
1
4
2
13
4 2
Plug M12 3-pole · Socket M12 3-pole ecolink
3
1
4
–
–
–
–
–
–
–
–
–
–
4 3
1
3
1
4 4 3
1
3
1
4 4 3
1
•
•
•
•
•
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
ProtectionType Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
250 AC, 300 DC 4 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.6...1.52)
250 AC, 300 DC 4 -25...85 IP 68 PUR CuZn/Ni 0.7...0.9
Technical data
Plug M12 3-pole
Plug M12 4-pole
60 AC, 75 DC 3 -25...85 IP 68 PUR CuZn/Ni 0.6...0.7Socket M8 4-pole
250 AC, 300 DC / 10...36 DC 4 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.6...1.5Socket M12 3-pole
PUR cable black4 x 0.25 mm2, Ø 4.4 mm
PUR cable black3 x 0.34 mm2, Ø 4.3 mm
Socket
PIN
1
1
BN
3 4
3 BU
4 BK
Plug
Socket
Plug
PIN
1
1
BN
2 3
2 WH
3 BU
4
4
BK
Wiring diagram /Wire specification
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
LED: signals yellow, operating voltage green
EVC040
EVC041
EVC042
EVC043
EVC044
EVC045
EVC046
EVC047
EVC048
EVC049
EVC050
EVC051
EVC052
EVC053
EVC054
ecolink. The new quality standard
in connection technology.
2)adhere to the maximum value of the counterpart
12
For industrialapplications
Type Pinassignment
plug
Pinassignment
socket
Cable
[m]
LEDs Order no.
Jumpers
Plug M12 4-pole · Socket M12 4-pole ecolink
3
1
4
2
–
–
–
–
–
–
–
–
–
–
4
2
3
1
3
1
4
2
4
2
3
1
3
1
4
2
4
2
3
1
•
•
•
•
•
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
ProtectionType Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
250 AC, 300 DC 4 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.6...1.52)
250 AC, 300 DC / 10...36 DC 4 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.6...1.5
Technical data
Plug M12 4-pole
Socket M12 4-pole
PUR cable black4 x 0.34 mm2, Ø 4.9 mm
Socket
Plug
PIN
1
1
BN
2 3
2 WH
3 BU
4
4
BK
Wiring diagram /Wire specification
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
LED: signals yellow, operating voltage green
EVC010
EVC011
EVC012
EVC013
EVC014
EVC015
EVC016
EVC017
EVC018
EVC019
EVC020
EVC021
EVC022
EVC023
EVC024
ecolink. The new quality standard
in connection technology.
3
1
4
2
4
2
3
1
–
–
–
EVC025
EVC026
EVC027
–
–
EVC028
EVC029
0.3
0.6
1
2
5
3
1
4
2
4
2
3
1
–
–
–
EVC030
EVC031
EVC032
–
–
EVC033
EVC034
0.3
0.6
1
2
5
3
1
4
2
4
2
3
1
•
•
•
EVC035
EVC036
EVC037
•
•
EVC038
EVC039
0.3
0.6
1
2
5
2)adhere to the maximum value of the counterpart
LED: signals yellow, operating voltage green
13
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
ProtectionType Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
30 AC, 36 DC 43) -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.6...1.52)
30 AC, 36 DC 43) -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.6...1.5
Technical data
Plug M12 5-pole
Socket M12 5-pole
Plug M12 5-pole · Socket M12 5-pole ecolink
3
1
4
2
5
–
–
–
EVC055
EVC056
EVC057
–
–
EVC058
EVC059
4
2
3
1
5
Type Pinassignment
plug
Pinassignment
socket
Cable
[m]
LEDs Order no.
Jumpers
Wiring diagram /Wire specification
0.3
0.6
1
2
5
3
1
4
2
5
–
–
–
EVC060
EVC061
EVC062
–
–
EVC063
EVC064
4
2
3
1
5
0.3
0.6
1
2
5
3
1
4
2
5
–
–
–
EVC065
EVC066
EVC067
–
–
EVC068
EVC069
4
2
3
1
5
0.3
0.6
1
2
5
3)cRUus 3A 2)adhere to the maximum value of the counterpart
ecolink. The new quality standard
in connection technology.
PUR cable black5 x 0.34 mm2, Ø 4.9 mm
Socket
Plug
PIN
1
1
BN
2 3
2 WH
3 BU
4
4
BK
5
5 GY
14
For industrialapplications
Type Pinassignment
plug
Pinassignment
DIN-plug
Cable
[m]
Version Order no.
Jumpers M12 plug / valve plug
Plug M12 3-pole · Valve plug 3-pole
3 4
5 DIN A
E11416
E11417
E11418
E11419
E11420
2 1
2 1
2 1
3 4
51 2
3 4
5
DIN B
E11421
E11422
E11423
E11424
E11425
Plug M12 3-pole · Valve plug 3-pole
3 4
5industrystandard
B
E11431
E11432
E11433
E11434
E11435
3 4
5
industrystandard
C
E11436
E11437
E11438
E11439
E11440
DIN C
E11426
E11427
E11428
E11429
E11430
Wiring diagram /Wire specification
PUR cable black3 x 0.5 mm2, Ø 5 mm
Socket
PIN
3
1
BN
2 PE
4 BU
5 YE/GN
Plug
PUR cable black3 x 0.5 mm2, Ø 5 mm
Operating voltage
[V]
Currentrating
[A]
Operatingtemperature
[°C]
Protec-tion
Type Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
250 AC, 300 DC 4 -25...85 IP 68 PUR CuZn/Ni 0.7...0.9
24 AC/DC 3 -25...80 IP 67 PUR CuZn/Ni –
Technical data
Plug M12
Valve plug
Socket
PIN
3
1
BN
2 PE
4 BU
5 YE/GN
Plug
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
1 2
LED: signal yellow
15
Passive splitter boxeswith M12 locations
Type Pinassignment
Signalson pin
Connection/ Cable
[m]
LED Order no. Wiring diagram /Wire specification
Technical data
Splitter boxes with cable ecolink
Splitter boxes with connector ecolink
Plug
Locationno.
PIN 1L+
3L-
4signal
1 BN BU WH
2 BN BU GN
3 BN BU YE
2signal
GY/PK
RD/BU
PE
GN/YE
GN/YE
4 BN BU GY
WH/GN
BN/GN
GN/YE
GN/YE
5 BN BU PK
6 BN BU RD
WH/YE
YE/BN
GN/YE
GN/YE
7 BN BU BK
8 BN BU VT
WH/GY
GY/BN
GN/YE
GN/YE
PUR cable black
Plug
PIN 1L+
3L-
4signal
1 19 6 15
2 19 6 5
3 19 6 16
2signal
7
4
PE
12
12
4 19 6 3
8
14
12
12
5 19 6 17
6 19 6 2
9
13
12
12
7 19 6 11
8 19 6 1
10
18
12
12
Locationno.
EBC015
EBC016
EBC013
EBC014
EBC027
EBC028
EBC025
EBC026
10
5
10
5
10
5
10
5
EBC019
EBC020
EBC017
EBC018
EBC031
EBC032
EBC029
EBC030
EBC023
EBC024
EBC021
EBC022
EBC035
EBC036
EBC033
EBC034
–
–
•
•
4
–
–
•
•
2 and 4
–
–
•
•
4
–
–
•
•
2 and 4
–
–
•
•
4
–
–
•
•
2 and 4
10
5
10
5
10
5
10
5
10
5
10
5
10
5
10
5
4
2
3
1
5
4 3
1
5
4
2
3
1
5
4 3
1
5
4
2
3
1
5
4 3
1
5
EBC002
EBC004
EBC001
EBC003
EBC006
EBC008
EBC005
EBC007
EBC010
EBC012
EBC009
EBC011
4 3
1
5
4
2
3
1
5
4 3
1
5
4
2
3
1
5
4 3
1
5
4
2
3
1
5
–
•4
2 and 4
M23
M23
–
•4
2 and 4
M23
M23
–
•
–
•
–
•
–
•
4
2 and 4
M23
M23
LED: signals yellow, operating voltage green
LED: signals yellow, operating voltage green
Operating voltage /Operating voltage with LED
[V]
Current rating[A]
Operatingtemperature
[°C]
ProtectionType Housingmaterial
Lockingmaterial
60 AC, 75 DC / 10...30 DC 4 per location, 12 in total -25...80 IP 67 PA CuZn/Ni
60 AC, 75 DC / 10...30 DC 4 per location, 12 in total -25...80 IP 67 PA CuZn/Ni
Cable
Plug M23
16
Passive splitter boxeswith M8 locations
Wiring diagram /Wire specification
Operating voltage
[V]
Currentrating
[A]
Operatingtemperature
[°C]
Protec-tion
Housingmaterial
Lockingmaterial
Operatingvoltage
LED
10...30 DC 2 per location, 6 in total -25...90 IP 67 PBT-GF20 CuZn/Ni green
Signalindication
LED
yellow
Technical data
E11216
E11219
M12
Splitter box 8 locations 3-pole · Cable
Splitter box 8 locations 4-pole · Cable
E11214
E11215
E11217
E11218
Splitter box 4 locations 3-pole · Connector
Splitter box 4 locations 4-pole · Connector
Plug
Locationno.
PIN 1L+
3L-
4signal
1 BN BU GN
2 BN BU YE
3 BN BU GY
4 BN BU PK
5 BN BU WH
6 BN BU RD
7 BN BU BK
8 BN BU VT
Plug
Locationno.
PIN 1L+
3L-
4signal
1 5 7 1
2 5 7 2
3 5 7 3
4 5 7 4
Plug
Locationno.
PIN 1L+
3L-
4signal
1 A L P
2 A L J
3 A L T
4 A L S
2signal
E
O
C
N
Plug
Locationno.
PIN 1L+
3L-
4signal
1 BN BU WH
2 BN BU GN
3 BN BU YE
4 BN BU GY
5 BN BU PK
6 BN BU RD
7 BN BU BK
8 BN BU VT
2signal
GY/PK
RD/BU
WH/GN
BN/GN
WH/YE
YE/BN
WH/GY
GY/BN
PUR cable black16 x 0.34 mm2, 2 x 0.75 mm2, Ø 9.1 mm
PUR cable black8 x 0.34 mm2, 2 x 0.75 mm2, Ø 9.1 mm
4
13
13
4 2
4
13
13
4 2
Type Pinassignment
Signalson pin
Connection/ Cable
[m]
LED Order no.
10
5
10
5
•4
•4
•2 and 4
•2 and 4
•4
M16•2 and 4
For industrialapplications
17
M8, M12 sockets
Type Pinassignment
5
Cable
[m]
LEDs
Socket M8 3-pole
Currentrating
[A]
Operatingtemperature
[°C]
Protection Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
3 -25...85 IP 68 PVC SS (316S12) 0.6...0.7
3 -25...85 IP 68 PVC SS (316S12) 0.6...0.7
4 -25...100 IP 68 / IP 69K PVC SS (316S12) 0.6...1.5
4 -25...100 IP 68 / IP 69K PVC SS (316S12) 0.6...1.5
–
10 –
25
5
10
25
5
10
25
5
10
25
5
10
25
–
–
–
–
Order no.
E11495
E11496
E11497
E11498
E11499
E11500
Wiring diagram /Wire specification
Technical data
PVC cable orange3 x 0.25 mm2, Ø 5 mm
PVC cable orange4 x 0.25 mm2, Ø 5 mm
PVC cable orange4 x 0.34 mm2, Ø 4.9 mm
PVC cable orange5 x 0.34 mm2, Ø 5.1 mm
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
5
GY
Socket
PIN
Colours
1
BN
3
BU
4
BK
•
•
•
E11501
E11502
E11503
Socket M8 4-pole
13
4 2
–
–
–
–
–
–
E11223
E11224
E11225
E11220
E11221
E11222
Socket M12 4-pole
Socket M12 5-pole
Operating voltage /Operating voltage with LED
[V]
Type
60 AC, 75 DC / 10...30 DC
60 AC, 75 DC
250 AC, 300 DC / 10...36 DC
30 AC, 36 DC
M8 3-pole
M8 4-pole
M12 4-pole
M12 5-pole
4
13
13
4 2
4
13
4
13
LED: signals yellow, operating voltage green
LED: signals yellow, operating voltage green
For hygienicand wet areas
5
10
25
5
10
25
5
10
25
5
10
25
5
10
25
–
–
–4
2
3
1
–
–
–
EVT001
EVT002
EVT003
EVT004
EVT005
EVT006
•
•
•
EVT007
EVT008
EVT009
4
2
3
1
5
–
–
–
–
–
–
EVT010
EVT011
EVT012
EVT013
EVT014
EVT015
4
2
3
1
4
2
3
1
4
2
3
1
5
ecolink. The new quality standard
in connection technology.
18
For hygienicand wet areas
Jumpers
Type Pinassignment
plug
Pinassignment
socket
Cable
[m]
LEDs Order no.
Plug M12 3-pole · Socket M12 3-pole ecolink
3
1
4
–
–
–
–
–
–
EVT022
EVT023
EVT024
–
–
EVT025
EVT026
EVT028
EVT029
EVT030
–
–
EVT031
EVT032
4 3
1
3
1
4 4 3
1
3
1
4 4 3
1
•
•
•
EVT034
EVT035
EVT036
•
•
EVT037
EVT038
PVC cable orange4 x 0.34 mm2, Ø 4.9 mm
Socket
PIN
1
1
BN
3 4
3 BU
4 BK
Plug
Wiring diagram /Wire specification
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
– EVT027
– EVT033
• EVT039
10
10
10
LED: signals yellow, operating voltage green
Plug M12 4-pole · Socket M12 4-pole ecolink
3
1
4
2
–
–
–
–
–
–
EVT040
EVT041
EVT042
–
–
EVT043
EVT044
EVT046
EVT047
EVT048
–
–
EVT049
EVT050
4
2
3
1
3
1
4
2
4
2
3
1
3
1
4
2
4
2
3
1
•
•
•
EVT052
EVT053
EVT054
•
•
EVT055
EVT056
0.3
0.6
1
2
5
0.3
0.6
1
2
5
0.3
0.6
1
2
5
– EVT045
– EVT051
• EVT057
10
10
10
PVC cable orange4 x 0.34 mm2, Ø 4.9 mm
Socket
Plug
PIN
1
1
BN
2 3
2 WH
3 BU
4
4
BK
LED: signals yellow, operating voltage green
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
ProtectionType Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
250 AC, 300 DC 4 -25...100 IP 67/ IP 68/ IP 69K PVC SS (316S12) 0.6...1.52)
250 AC, 300 DC 4 -25...100 IP 67/ IP 68/ IP 69K PVC SS (316S12) 0.6...1.52)
Technical data
Plug M12 3-pole
Plug M12 4-pole
250 AC, 300 DC / 10...36 DC 4 -25...100 IP 67/ IP 68/ IP 69K PVC SS (316S12) 0.6...1.5Socket M12 3-pole
250 AC, 300 DC / 10...36 DC 4 -25...100 IP 67/ IP 68/ IP 69K PVC SS (316S12) 0.6...1.5Socket M12 4-pole2)adhere to the maximum value of the counterpart
ecolink. The new quality standard
in connection technology.
ecolink. The new quality standard
in connection technology.
Jumpers
Type Pinassignment
plug
Pinassignment
socket
Cable
[m]
LEDs Order no.
Plug M12 5-pole · Socket M12 5-pole ecolink
3
1
4
2
5
–
–
–
EVT058
EVT059
EVT060
–
–
EVT061
EVT062
4
2
3
1
5
0.3
0.6
1
2
5
– EVT06310
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
ProtectionType Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
30 AC, 36 DC 4 -25...100 IP 67/ IP 68/ IP 69K PVC SS (316S12) 0.6...1.52)
Technical data
Plug M12 5-pole
30 AC, 36 DC 4 -25...100 IP 67/ IP 68/ IP 69K PVC SS (316S12) 0.6...1.5Socket M12 5-pole2)adhere to the maximum value of the counterpart
PUR cable orange4 x 0.34 mm2, Ø 4.9 mm
Socket
Plug
PIN
1
1
BN
2 3
2 WH
3 BU
4
4
BK
5
5 GY
Wiring diagram /Wire specification
19
20
For oils andcoolants
M12 sockets
Type Pinassignment
Cable
[m]
LEDs Order no.
2
Socket M12 4-pole ecolink
–
5 –
10 –
2 –
5 –
10 –
2 •
5 •
10 •
2
Socket M12 5-pole ecolink
–
5 –
10 –
2 –
5 –
10 –
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
ProtectionType Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
250 AC, 300 DC / 10...36 DC 4 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.6...1.5
4 -25...90 IP 67/ IP 68/ IP 69K PUR CuZn/Ni 0.6...1.530 AC, 36 DC
Technical data
M12 4-pole
M12 5-pole
PUR cable black4 x 0.34 mm2, Ø 4.9 mm
PUR cable black5 x 0.34 mm2, Ø 5 mm
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
5
GY
4
2
3
1
4
2
3
1
4
2
3
1
5
4
2
3
1
4
2
3
1
5
LED: signals yellow, operating voltage green
Wiring diagram /Wire specification
EVC001
EVC002
EVC003
EVC004
EVC005
EVC006
EVC007
EVC008
EVC009
EVC070
EVC071
EVC072
EVC073
EVC074
EVC075
ecolink. The new quality standard
in connection technology.
21
For sensors inrobust applications
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
ProtectionType Housingmaterial
Lockingmaterial
Tighteningtorque[Nm]
250 AC, 300 DC / 10...36 DC 4 -40...90 IP 67/ IP 68/ IP 69K PUR SS (316S12) 0.6...1.5
Technical data
M12 4-pole
Wiring diagram /Wire specification
M12 sockets
Type Pinassignment
Cable
[m]
LEDs Order no.
Socket M12 4-pole ecolink
LED: signals yellow, operating voltage green
PUR cable black4 x 0.34 mm2, Ø 4.9 mm
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
2 –
5 –
10 –
2 –
5 –
10 –
EVM001
EVM002
EVM003
EVM004
EVM005
EVM006
2 •
5 •
10 •
EVM007
EVM008
EVM009
4
2
3
1
4
2
3
1
4
2
3
1
ecolink. The new quality standard
in connection technology.
22
For electro-magnetic fields
M12 sockets
2
Socket M12 4-pole ecolink
–
5 –
10 –
2 –
5 –
10 –
EVW001
EVW002
EVW003
EVW004
EVW005
EVW006
2 •
5 •
10 •
EVW007
EVW008
EVW009
2
Socket M12 5-pole ecolink
–
5 –
10 –
2 –
5 –
10 –
EVW010
EVW011
EVW012
EVW013
EVW014
EVW015
Technical data
PUR cable grey, halogen-free, silicone-free, recyclable4 x 0.34 mm2, Ø 4,9 mm
PUR cable grey, halogen-free, silicone-free, recyclable5 x 0.34 mm2, Ø 5.1 mm
Dose
PIN
Farben
1
BN
2
WH
3
BU
4
BK
4
2
3
1
4
2
3
1
4
2
3
1
5
4
2
3
1
4
2
3
1
5
LED: signals yellow, operating voltage green
Wiring diagram /Wire specification
4)when screwed to the matching counterpart
Type Pinassignment
Cable
[m]
LEDs Order no.
ecolink. The new quality standard
in connection technology.
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
5
GY
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
Protection4)Type Housing
materialLockingmaterial
Tighteningtorque[Nm]
250 AC, 300 DC / 10...36 DC 4 -25...90 IP 67/ IP 68/ IP 69K TPU TPI, CuZn,safecoating
0.6...1.5
4 -25...90 IP 67/ IP 68/ IP 69K TPU 0.6...1.530 AC, 36 DC
M12 4-pole
M12 5-pole
23
For hazardous areas
Wiring diagram /Wire specification
Sockets · JumpersM12
2
Socket M12 4-pole ecolink
–
5 –
10 –
EVC04A
EVC05A
EVC06A4
2
3
1
PUR cable black, halogen-free, silicone-free4 x 0.34 mm2, Ø 4.9 mm
Approvals:
EC type examination certificate for componentsfrom DEKRA EXAM
IECEx BVS 08.0041 UBVS 08 ATEX E 109 U
Marking:II 3G Ex nA II Ta: -20...60 °CII 2D Ex tD A21 IP67
Technical data
0.3
Plug M12 4-pole · Socket M12 4-pole ecolink
–
0.6 –
1 –
2 –
5 –
10 –
EVC09A
EVC10A
EVC11A
EVC07A
EVC12A
EVC13A
4
2
3
1
5
4
2
3
1
5
4)when screwed to the matching counterpart
Operating voltage /Operat. voltage with LED
[V]
Currentrating
[A]
Operatingtemperature
[°C]
Protec-tion
4)Type Housing
materialLockingmaterial
Tighteningtorque[Nm]
Type Pinassignment
Cable
[m]
LEDs Order no.
ecolink. The new quality standard
in connection technology.
Dose
PIN
Farben
1
BN
2
WH
3
BU
4
BK
Socket
PIN
Colours
1
BN
2
WH
3
BU
4
BK
60 AC, 60 DC 4 -20...60 IP 67 TPUGRIVORY GV-GH
high-grade stainl. steel(316L/1.4404)
1.2...1.5M12 4-pole
ifm a
rtic
le n
o. 7
5113
99 ·
We
rese
rve
the
right
to
mak
e te
chni
cal a
ltera
tions
with
out
prio
r no
tice.
· Pr
inte
d in
Ger
man
y on
non
-chl
orin
e bl
each
ed p
aper
. 04
/10
Over 70 locations worldwide – at a glance atwww.ifm.com
visit our website:
www.ifm.com
Position sensorsand object recognitionInductive sensorsCapacitive sensorsMagnetic sensors,cylinder sensorsSafety technologyValve sensorsPhotoelectric sensorsObject recognitionEncodersEvaluation systems,power suppliesConnection technology
Fluid sensorsand diagnostic systemsLevel sensorsFlow sensorsPressure sensorsTemperature sensorsDiagnostic systemsEvaluation systems,power suppliesConnection technology
Bus systemsBus system AS-InterfacePower suppliesConnection technology
Identification systemsMulticode reading systemsRF-identification systemsPower suppliesConnection technology
Control systemsControl systemsfor mobile vehiclesConnection technology
Overview ifm product range:
ifm electronic gmbhFriedrichstraße 145128 EssenTel. +49 / 201 / 24 22-0Fax +49 / 201 / 24 22-1200E-Mail: [email protected]