Geoflow Subsurface Drip Dispersal Systems in freezing conditions 2011 WCOWMA Conference 1 Subsurface Drip Dispersal Introduction to SDD design for cold climates FREEZING CONDITIONS Geoflow Agenda Cold climate experience and research Design concepts for cold climate Example system Further design concepts Questions and discussion 2 Geoflow
41
Embed
Geoflow Subsurface Drip Dispersal · Geoflow Subsurface Drip Dispersal Systems in freezing conditions 2011 WCOWMA Conference 4 Other typical sites Where site or ecosystem impact must
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
1
Subsurface Drip Dispersal
Introduction to SDD design for cold climates
FREEZING CONDITIONS
Geoflow
Agenda
Cold climate experience and research
Design concepts for cold climate
Example system
Further design concepts
Questions and discussion
2Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
2
What is SDD?
Application of effluent by drip emitters Applies water directly into the root zone (6-12
inches deep)
More evapotranspiration
Puts effluent in the most biologically active soil zone
Keeps soil drier for better treatment and greater horizontal dispersal
3Geoflow
Dose Mode
When WASTEFLOW PC is pressurized,
the rubber diaphragm flexes across
the compensating chamber to regulate
flow regardless of pressure variances
Each dripper has a filter built in at the entry port.
Effluent travels through a turbulent flow path
that helps keep any fine particles from settling inside the dripper. And slows theflow until flow is laminar at discharge
WASTEFLOW ClassicFlow varies with pressure
Flush Mode.
As the pump is powered on and
again powered off, system pressure
relaxes across the exit hole
enabling the dripper to
self flush every cycle.
WASTEFLOW PC = pressure compensatingGives same output flow even if emitters are at different levels
Drip emitters PC emitters usually have lower flow rates
PC = Pressure compensating
4Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
3
Water movement from emitter
Subsurface drip Surface drip
5Geoflow
Typical Sites
If severely constrained for conventional drainfields Depth
Slope
Shape and slope alignment
Size or setbacks
Heavy soils
Sand/gravel soils
6Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
4
Other typical sites
Where site or ecosystem impact must be reduced
Where in soil treatment must be maximized
Where irrigation/reuse is a priority For cost savings on large systems
7Geoflow
Typical SDD layout
Dose manifold
Shows single lines (not looped)
Dose forcemain
Flush main
Returns to trash tank inlet 8
Air valveAir valve
Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
5
SDD IN COLD CLIMATES
9
Geoflow
Geoflow
Research and experience since the 1990s Wisconsin—Bohrer and Converse
Minnestota—Scott Wallace, NAWE
Wetland applications (various)—NAWE
New Zealand—Peter Gearing, URS
Colorado and Utah high altitude systems
BC (Southern Interior, Prince George)
Eastern Washington state (Scott Jones)
Small, medium and large systems
10Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
6
11
Large Systems under Freezing Conditions
Aluminum Smelter (Invercargill, NZ)
Disposing 78,000 gallons of human effluent per day over 12.35 acres.
Steep wooded slope down to a fragile stream which is monitored by Fish & Game.
Reference: Matt Freeman, DPW, Maricopa County, California.
Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
7
13
Large Systems under Freezing Conditions
Tenaya Lodge (Fish Camp, CA)
Installed Summer 2000.
Slope in excess of 50% at the top of the section.
20,000 gpd.
Designed by: Summit Engineering Tel: 707-527-0775
Project overseen by Jack Niblett Tel: 559-692-5340
Geoflow
NAWE cold climate wetlands
14
B.P. Casper, Wyoming. Wetland 3.3mgpd by NAWE
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
8
Shenyang, China vertical flow wetland
SSD used for distribution to reed planted wetland with subdrain discharge
-25 to -30 C in February/March
Improved efficiency 1 sqm/pe vs more normal 2 sqm/pe
6000 person equivalent = 750 cum/day size
Blumberg Engineering and NAWE, 2004
15Images: Blumberg Engineering. Geoflow
16
SDD distribution system
Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
9
17Geoflow
18
.
. Minnesota
Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
10
19
.
.Minnesota
Minnesota
Drip mounds in E. Washington
Cold, dry climate
Type 1 to sand mound
Many systems
Only one freezing issue to date Due to winter startup with cold water
Short term
20Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
11
BC experience
Prince George
Kelowna
Penticton
Kamloops
No freezing issues even where some conventional systems froze.
Even in cold dry climates
CAREFUL DESIGN AND INSTALLATION
21Geoflow
Research papers on Geoflow website
http://www.geoflow.com/research_w.html
Drip Distribution Soil Performance and Operations in a Northern Climate by R. Bohrer
Bohrer Thesis
Design & Performance of Drip Dispersal Systems in Freezing Environments by S.D. Wallace
22Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
12
Soil temperature
Soil temperature measurement in dispersal systems
Temperature found to be higher than ambient
Example Roger Shafer, Colorado Septic tank, textile filter and polishing sand filter
Standard pressure distribution system
23
Use of a Recirculating Textile Filter followed by a Polishing Sand Filter for Onsite Wastewater Treatment in Colorado’s Fractured Bedrock Environment Roger J. Shafer, P.E., Fractured Rock Aquifers 2002 conference, Denver Colorado, 2002
Geoflow
24
Sand filter temperature maintains above freezing at 1 inch below surface
Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
13
Biological activity and freezing
Bernhart research (Ontario)
Opinion that biologically active, aerobic systems keep warmer
And have higher winter evaporation from soil
This favors use of Type 1 effluent
25Geoflow
SDD in frozen soils
Bohrer and Converse paper and others
SDD lines in soil that is below freezing point
SDD still functions
26Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
14
Bohrer and Converse
Soil < 0 C at and also < 0 C 4ʺ below dripline Temperatures as low as – 12 C in soil observed
Ice crystals found in soil cores, but pores still open
Effluent dosing does warm the soil Warm effluent is important
27Geoflow
8 systems monitored in Minnestota, Scott Wallace 7.5 to 60cm cover over dripline
Soil below freezing at dripline Temperature probes and soil cores
Temperature between doses lower than surrounding soil with light loading Heavier loading showed more dose impact
Air valve enclosure design to reduce impact of freezing conditions
28Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
15
Residential system—light loading
29
30
Elementary school
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
16
Saturation issues
Installation error led to standing water in dripline at the school in January 2000
Field froze due to high water in tank backing up into dripline
31Geoflow
Air circulation on systems with two air valves Scott Wallace’s paper shows soil at dripline
to be cooler between doses than surrounding soils
Theorizes this is due to air circulation
Effluent warming soil only supported for heavier loadings
Consider: Single air valve system
Sealed air valve boxes
32Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
17
What helps SDD to work in frozen soil?
Soil is not saturated Larger pores are not clogged with ice crystals
Small doses do not lead to clogging
Water has short distance to travel vertically to non frozen soil
Some frozen water will sublimate
Dripline and manifolds drained down between doses—design and installation is critical
33Geoflow
KEY DESIGN CONCEPTS
34
Geoflow
Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
18
Drain back
Drain manifolds and dripline back
Drain rapidly
Any more than 15 mins may freeze Keep it to 10 mins or less
Design and also TEST at commissioning
Make sure forcemains slope properly And are lower than the dripline
35Geoflow
Insulate
Insulate dose and flush forcemains
Even when draining back
Insulate headworks (if not in pump chamber)
Insulate air valves
36Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
19
Keep the dripline warm
Install with 8ʺ cover minimum.
Consider temporary insulation (peat, sawdust etc) for first year.
Revegetate.
Trap snow.
37Geoflow
Keep the effluent warm
Insulate lid of tanks and riser lids
Create heat island by extending insulation laterally
Try to get heat island next to house
Use treatment that keeps effluent warmer
Type 1 is warmest
Keep draining volumes low (reduce cooling of effluent)
38Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
20
Special case effluent temperature
Caution with cold water systems Example highway rest area
Caution with startup in winter
Caution with seasonal use systems that get used at Christmas…
39Geoflow
Continuous flush
Do NOT use continuous flush in cold climates
Cools effluent by running it through the field
Reduces treatment performance
And greater risk of freezing
40Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
21
Soil type
Consider soil drainage
Design for the soil Do not allow saturation around emitters
Do not allow water to drain along driplines
Do not damage soils at installation!
Do not use Type 1 in low permeability soils Reduced activity in winter may lead to biomat and
saturation near emitters/line
41Geoflow
Site
Sloping sites are easier Drainage
Frost drainage
South facing best
Steep slope is even better
Tanks below field area preferable
But can use less favorable sites
42Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
22
Climate
Heavy snow cover insulates
More care where snow is not reliable
Consider microclimate 12ʺ cover where shaded, frost hollows
43Geoflow
Site use—some considerations
Keep people off the field in the winter
Do not compact or remove the snow
Try to trap snow
Deep vegetation or forest cover preferable
Do not compact soils
44Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
23
AIR VACUUM VALVE DESIGN
45
Geoflow
Geoflow
Drainback design—Air valves SDD systems need to draw air from air
vacuum valves when draining
Caution not to allow cold air to circulate through valves and pipes
Risk of air valves freezing and either leaking or not allowing air back in for drain down.
Prefer to draw warmer air into air valve
Air valves are most likely part of system to freeze
Try to keep it to one or two valves
Regular inspection of air valves 46
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
24
Insulated air valve installation
Creates heat island at valve
Valve draws warm air from deep in soil profile
Concept developed from NAWE research
In sealed valve box Polylok riser/lid suitable
47Geoflow
Air valve detail
48Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
25
Sizing of excavation
Base on void space in drainrock fill
49Geoflow
Sealed, insulated air valve boxes
Less likely to lead to air circulation in situation with more than one air valve
Air is warmer if it does circulate
50Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
26
Air valve in tank
Can install air valve in pump chamber
With filter headworks
Site specific (tank above field)
Will need to drain the manifolds and line to a secondary tank lower down
51Geoflow
52
Line slopes down to field
Air valve
FilterNote unions
Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
27
53
Site near Kamloops
Design: Chad Meir and Ian RalstonInstall: John Pavlovich
Drains to tank below field, with small pump to return flows to trash tank.
Geoflow
54Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
28
55Geoflow
56Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
29
SYSTEM EXAMPLE
Summerland system.
Design Karen Halliday and Ian Ralston Install Gary Dicken
57
Geoflow
Geoflow
Site and soils
Steeply sloping site
Slope 40 – 50%, slope to SW
Soil Silt Loam BK/2, sl hard. Perk. 34 mins.
Shallow soil over shale
Constrained soil area
58Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
30
Single air valve design
Sloping dripline
Dose and flush connections with pressure test ports Insulated valve boxes!
59Geoflow
60
Dripline, sloping from dose to flush
Setback
Headworksand tanks in insulated heat island
Air valve
Second dripline
Flush connections
Dose and flush mains
Flush and dose connections with pressure test portsGeoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference
31
Headworks flow paths
61Geoflow
62
Filter drains to pump discharge orifice
NC Flush valve. Opens to drain system
NO drain valve, open when pump off
Pressure regulator
Geoflow
Geoflow Subsurface Drip Dispersal Systems in freezing conditions2011 WCOWMA Conference