Top Banner
1 19972255 Marvin Signature Collection Architectural Detail Manual General Mulling Information General Mull Information - Mull Types ................................................................................................................... 3 Ultimate Casement Mull Types .............................................................................................................................. 9 Ultimate Casement Narrow Frame Mull Types ...................................................................................................... 23 Ultimate Direct Glaze Mull Types ........................................................................................................................... 37 Ultimate Direct Glaze Round Top Mull Types ........................................................................................................ 49 Ultimate Direct Glaze Narrow Frame Mull Types ................................................................................................... 61 Ultimate Double Hung G2 Mull Types .................................................................................................................... 75 Ultimate Glider Mull Types ..................................................................................................................................... 91 Multi-High, Multi-Wide Mulling................................................................................................................................ 101 Ultimate Inswing French Door Mull Types.............................................................................................................. 107 Ultimate Outswing French Door Mull Types ........................................................................................................... 111 Ultimate Sliding French Door Mull Types ............................................................................................................... 115 Ultimate Sliding Patio Door Mull Types .................................................................................................................. 119 Modern Casement Mull Types ............................................................................................................................... 123 Modern Direct Glaze Mull Types ............................................................................................................................ 127 Modern Swinging Doors Mull Types....................................................................................................................... 131 Modern Additional Steel Mull Types ....................................................................................................................... 135
149

General Mulling Information

May 14, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: General Mulling Information

1 19972255Marvin Signature CollectionArchitectural Detail Manual

General Mulling InformationGeneral Mull Information - Mull Types ................................................................................................................... 3Ultimate Casement Mull Types .............................................................................................................................. 9Ultimate Casement Narrow Frame Mull Types ...................................................................................................... 23Ultimate Direct Glaze Mull Types........................................................................................................................... 37Ultimate Direct Glaze Round Top Mull Types ........................................................................................................ 49Ultimate Direct Glaze Narrow Frame Mull Types ................................................................................................... 61Ultimate Double Hung G2 Mull Types.................................................................................................................... 75Ultimate Glider Mull Types ..................................................................................................................................... 91Multi-High, Multi-Wide Mulling................................................................................................................................ 101Ultimate Inswing French Door Mull Types.............................................................................................................. 107Ultimate Outswing French Door Mull Types........................................................................................................... 111Ultimate Sliding French Door Mull Types............................................................................................................... 115Ultimate Sliding Patio Door Mull Types.................................................................................................................. 119Modern Casement Mull Types ............................................................................................................................... 123Modern Direct Glaze Mull Types............................................................................................................................ 127Modern Swinging Doors Mull Types....................................................................................................................... 131Modern Additional Steel Mull Types....................................................................................................................... 135

Page 2: General Mulling Information

219972255

Marvin Signature Collection Architectural Detail Manual

Page 3: General Mulling Information

Mull-3 19972255Marvin Signature Collection Architectural Detail Manual

General Mulling Information

Ver 2019.3 2019-07-29

General Mull Information - Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. Some mulls can be done in the factory.Others would need to be done in the field. Some mulls create a certified assembly according to third-party testing.

Marvin Mull Options:Marvin-SuppliedStandard Mull (Ultimate): Two units mulled directly together without any reinforcement or space mulls between the frames. Standard Mull (Modern): 2 or more units mulled directly together with the standard 1/2" x 2 1/4" Aluminum; requires standard

interior and exterior mull covers. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field

assembly of the mullion.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull Reinforcement: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available from Marvin.

Space Mull: Non-continuous blocks of wood are used to space units apart. ◦ 3/8", 1", 2", 3", 4" and 6" widths are available.

Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation of an existingstructure in the opening. Units are shipped with temporary blocking. Remove before installation.

Field Supplied and Applied (these are other available mulling options, not provided by Marvin) Tube Mull: Tube aluminum or steel used to reinforce mulled assemblies. Flat Mull: Flat Steel or Aluminum used to reinforce mulled assemblies. These reinforcement types must be primed to prevent corrosion.

AnchoringSpecial considerations need to be made when installing mulled assemblies. Mullions create point loads that need to be

transferred to the rough opening. For Marvin standard, MRF, LVL, and space mulls, the ends of the mull need to be fastened oneach side of the splice with either jamb screws or brackets. Aluminum, steel and other structural mulls need to be anchoreddirectly to the rough opening or building structure.

Section Details:Cross sections will illustrate the mulling of two units.Tributary and Span:Tributary Width - The area supported by the mullion. In the case of a vertical mull, this is equal to the sum of half of the width of eachunit on each side of the mull.Span - The length of the mullion

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 4: General Mulling Information

General Mulling Information

Mull-4 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2020.1 2020-01-13

General Mull Information - Mull TypesCharts:

Mullion Performance ChartsIn accordance with the International Building Code, mullion performance is determined through either physical testing or calculations. A combination of both methods has been used to develop the performance charts. Calculated mulls limit deflection to L/175 (L=length of mullion) and limit allowable stress to 2/3 of the mull material’s allowable stress. Physically tested mulls often outperform calculations and this will show up on the charts as jumps in performances.

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

59606162 PG 65 DP 50 636465666768 DP 40 697071727374 PG50 DP 30 75767778798081828384 DP 20 85 DP 50 86878889909192939495969798 PG4099

100101102103104105106107108109110 DP30111 DP20112113114115116117118119120

Span

Tributary Width

Tested Sizes

Tested Size

Calculated Range

All sizes shown are in accordance with AAMA-450 and Building Codes.

PG – Performance Grade – These sizes have been physically tested for Air/Water and Structural Performance and are certified by WDMA.

DP – Design Pressure – These sizes have not been physically tested. The calculated range demonstrates the maximum range allowed for Structural Performance values.

Page 5: General Mulling Information

Mull-5 19972255Marvin Signature Collection Architectural Detail Manual

General Mulling Information

Ver 2019.3 2019-07-29

Field-Supplied and Applied Mull Types

Page 6: General Mulling Information

General Mulling Information

Mull-6 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Marvin Mull TypesNOTE: Mulls displayed with Ultimate Casement frames, but other products can also be used.

Page 7: General Mulling Information

Mull-7 19972255Marvin Signature Collection Architectural Detail Manual

General Mulling Information

Ver 2019.3 2019-07-29

Marvin Mull TypesNOTE: Mulls displayed with Ultimate Casement frames, but other products can also be used.

Page 8: General Mulling Information

General Mulling Information

Mull-8 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Page 9: General Mulling Information

Mull-9 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Casement product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field

assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.

Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.

Products IncludedUltimate Casement and AwningUltimate Casement PictureUltimate Venting PictureUltimate Pushout Casement and Awning Ultimate Casement French and Ultimate Casement Push Out French IZ3

Certified Mull Installation Methods:Masonry Clips Jamb ScrewsStructural Brackets

Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 10: General Mulling Information

Clad Mulling

Mull-10 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Casement Mulling Types

Page 11: General Mulling Information

Mull-11 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Casement Mulling Types (Continued)

Space Mulls and Solid Space Mulls are available in3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls up to 2".

Page 12: General Mulling Information

Clad Mulling

Mull-12 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Casement Mulling - Standard Frame (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58 DP 65

59606162 PG 65 DP 50 636465666768 DP 40 697071727374 PG50 DP 30 75767778798081828384 DP 20 85 DP 50 86878889909192939495969798 PG4099

100101102103104105106107108109110 DP30111 DP20112113114115116117118119120

Span

Tributary Width

Page 13: General Mulling Information

Mull-13 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP5626364656667686970717273 DP50747576777879808182 DP408384858687888990919293949596979899

100 DP40101102103104 DP30105106107 DP20108109110111112113 DP25114115116117118119120

Span

Tributary Width

Page 14: General Mulling Information

Clad Mulling

Mull-14 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Casement Mulling - 1" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP65626364656667686970717273747576 DP5077787980818283848586878889909192 DP4093949596979899

100 DP30101102103104105106107108109110 DP20111112113114115116117118119120

Tributary Width

Span

Page 15: General Mulling Information

Mull-15 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Mulling - 2" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP65626364656667686970717273747576 DP5077787980818283848586878889909192 DP4093949596979899

100 DP30101102103104105106107108109110111112113114115 DP20116117118119120

Span

Tributary Width

Page 16: General Mulling Information

Clad Mulling

Mull-16 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Casement Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

Page 17: General Mulling Information

Mull-17 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

5960 DP6561626364656667 DP5068697071727374 DP407576777879808182 DP3083848586878889909192 DP2093949596979899

100101102103104105106107108109110111112113114115116117118119120

Tributary Width

Span

Page 18: General Mulling Information

Clad Mulling

Mull-18 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Casement Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP6562636465666768697071 DP5072737475767778798081 DP408283848586878889909192939495 DP3096979899

100101102103104105106107108 DP20109110111112113114115116117118119120

Tributary Width

Span

Page 19: General Mulling Information

Mull-19 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP6562636465666768697071 DP507273747576777879808182 DP408384858687888990919293949596 DP30979899

100101102103104105106107108109110111112113114115 DP20 116117118119120

Span

Tributary Width

Page 20: General Mulling Information

Clad Mulling

Mull-20 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Casement Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88

24-58

59

60

61

62 DP65

63

64

65

66

67

68

69

70

71 DP50

72

73

74

75

76

77

78

79

80

81 DP40

82

83

84

85

86

87

88

89

90

91

92

93

94 DP30

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109 DP20

110

111

112

113

114

115

116

117

118

119

120

Span

Tributary Width

Page 21: General Mulling Information

Mull-21 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP6562636465666768697071 DP5072737475767778798081 DP4082838485868788899091929394 DP309596979899

100101102103104105106107108109110111 DP20112113114115116117118119120

Span

Tributary Width

Page 22: General Mulling Information

Clad Mulling

Mull-22 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Page 23: General Mulling Information

Mull-23 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Casement Narrow Frame product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field

assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.

Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.

Products IncludedUltimate Casement Narrow FrameUltimate Awning Narrow FrameUltimate Casement Push Out Narrow Frame Ultimate Awning Push Out Narrow FrameUltimate Casement/Awning Narrow Frame Picture

NOTE: Multi-High Multi-Wide Assemblies with any side that exceed 72” in either direction will be shipped with a temporary blockingaround the entire perimeter of the assembly to provide support during shipping and handling.

Certified Mull Installation Methods: Jamb Screws

Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 24: General Mulling Information

Clad Mulling

Mull-24 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Casement Narrow Frame Mulling Types

Page 25: General Mulling Information

Mull-25 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Casement Narrow Frame Mulling Types (Continued)

Space Mulls and Solid Space Mulls areavailable in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mullsup to 2".

Page 26: General Mulling Information

Clad Mulling

Mull-26 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mulling-Standard Frame (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 722425262728293031 PG50 DP5032333435363738394041 DP 40 424344 DP3045464748495051 DP205253545556575859606162636465666768 PG406970717273747576777879 PG308081828384

Span

Tributary Width

Page 27: General Mulling Information

Mull-27 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224252627282930313233343536373839404142 DP50434445464748495051525354555657585960616263646566 DP4067686970717273747576 DP407778 DP 307980818283848586878889 DP 209091929394959697

Tributary Width

Span

Page 28: General Mulling Information

Clad Mulling

Mull-28 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mulling - 1" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31

323334353637383940 PG50 DP5041424344454647484950 DP4051525354 DP3055565758596061 DP2062636465666768697071727374 DP207576777879808182

Span

Tributary Width

Page 29: General Mulling Information

Mull-29 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mulling - 2" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31

323334353637383940414243444546 PG50 DP50474849505152535455565758 DP4059606162 DP30636465666768 DP20697071727374 DP3075767778798081828384 DP20858687888990919293

Tributary Width

Span

Page 30: General Mulling Information

Clad Mulling

Mull-30 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224252627282930313233 DP5034353637383940414243 DP4044454647 DP3048495051525354 DP205556575859606162636465666768697071

Tributary Width

Span

Page 31: General Mulling Information

Mull-31 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224252627282930313233343536373839 DP5040414243444546 DP4047484950 DP30515253545556 DP205758596061626364656667686970717273747576

Span

Tributary Width

Page 32: General Mulling Information

Clad Mulling

Mull-32 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31

32333435 DP50363738394041424344454647484950 DP405152535455 DP3056575859606162 DP206364656667686970717273747576777879808182

Tributary Width

Span

Page 33: General Mulling Information

Mull-33 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31

3233343536 DP50373839404142434445464748495051525354 DP405556575859 DP3060616263646566 DP206768697071727374757677787980818283848586878889

Tributary Width

Span

Page 34: General Mulling Information

Clad Mulling

Mull-34 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-41

424344454647 DP504849505152535455565758 DP405960616263 DP30646566676869 DP207071727374757677787980818283848586878889909192939495

Tributary Width

Span

Page 35: General Mulling Information

Mull-35 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Casement Narrow Frame Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-41

42434445464748495051 DP5052535455565758596061626364 DP4065666768 DP3069707172737475 DP2076777879808182838485868788899091929394959697

Tributary Width

Span

Page 36: General Mulling Information

Clad Mulling

Mull-36 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Page 37: General Mulling Information

Mull-37 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Direct Glaze product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field

assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.

Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.

Products IncludedUltimate Direct GlazeUltimate Direct Glaze IZ3

Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets

Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 38: General Mulling Information

Clad Mulling

Mull-38 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Direct Glaze Mulling Types

Page 39: General Mulling Information

Mull-39 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Direct Glaze Mulling Types (Continued)

Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls upto 2".

Page 40: General Mulling Information

Clad Mulling

Mull-40 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Mulling - Standard Frame (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446 DP6548505254565860626466 DP50687072 DP40747678 DP308082848688 DP 209092 PG50949698

100102 PG40104106108110 DP30112114 DP20116118120

Tributary Width

Span

Page 41: General Mulling Information

Mull-41 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244464850 DP655254565860626466687072 DP507476788082 DP408486889092 DP30949698

100102104106 DP20108110112114116118120

Span

Tributary Width

Page 42: General Mulling Information

Clad Mulling

Mull-42 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Mulling - 1" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648505254 DP65565860626466687072 DP507476788082 DP408486889092 DP30949698

100102104106 DP20108110112114116118120

Span

Tributary Width

Page 43: General Mulling Information

Mull-43 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Mulling - 2" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446 DP6548505254565860626466687072 DP507476788082 DP40848688909294 DP309698

100102104106108110 DP20112114116118120

Span

Tributary Width

Page 44: General Mulling Information

Clad Mulling

Mull-44 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446485052 DP65545658606264666870 DP50727476 DP4078808284 DP308688909294 DP209698

100102104106108110112114116118120

Tributary Width

Span

Page 45: General Mulling Information

Mull-45 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446485052 DP6554565860626466687072 DP507476788082 DP4084868890 DP3092949698

100 DP20102104106108110112114116118120

Span

Tributary Width

Page 46: General Mulling Information

Clad Mulling

Mull-46 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446485052 DP6554565860626466687072 DP507476788082 DP40848688909294 DP309698

100102104106108 DP20110112114116118120

Span

Tributary Width

Page 47: General Mulling Information

Mull-47 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP65505254565860626466687072 DP507476788082 DP40848688909294 DP309698

100102104106108110 DP20112114116118120

Span

Tributary Width

Page 48: General Mulling Information

Clad Mulling

Mull-48 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Mulling - 4" and 6" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244464850 DP655254565860626466687072 DP507476788082 DP40848688909294 DP309698

100102104106108110112 DP20114116118120

Span

Tributary Width

Page 49: General Mulling Information

Mull-49 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Round Top Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Direct Glaze Round Top product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field

assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.

Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.

Products IncludedUltimate Direct Glaze Round TopUltimate Direct Glaze Polygon 4/4Ultimate Direct Glaze Round Top IZ3

Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets

Tributary and SpanTributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 50: General Mulling Information

Clad Mulling

Mull-50 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Direct Glaze Round Top Mulling Types

Page 51: General Mulling Information

Mull-51 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Direct Glaze Round Top Mulling Types (Continued)

Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls up to2".

Page 52: General Mulling Information

Clad Mulling

Mull-52 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Round Top Mulling - Standard Frame (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244 DP6546485052545658 DP50606264 DP4066687072 DP307476788082 DP208486889092949698

100102104106108110112114116118120

Tributary Width

Span

Page 53: General Mulling Information

Mull-53 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Round Top Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP505254565860626466687072 DP50747678808284 DP408688909294 DP309698100102104 DP20106108110112114116118120

Tributary Width

Span

Page 54: General Mulling Information

Clad Mulling

Mull-54 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Round Top Mulling - 1" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP6550525456586062646668707274 DP50767880828486 DP408890929496 DP3098

100102104106 DP20108110112114116118120

Tributary Width

Page 55: General Mulling Information

Mull-55 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Round Top Mulling - 2" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244464850 DP655254565860626466687072 DP507476788082 DP4084868890929496 DP3098

100102104106108110112114 DP20116118120

Span

Tributary Width

Page 56: General Mulling Information

Clad Mulling

Mull-56 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Round Top Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244464850 DP655254565860626466687072 DP507476788082 DP4084868890929496 DP3098

100102104106108110112114 DP20116118120

Span

Tributary Width

Page 57: General Mulling Information

Mull-57 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Round Top Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP655052545658606264666870 DP5072747678 DP4080828486 DP308890929496 DP2098

100102104106108110112114116118120

Span

Tributary Width

Page 58: General Mulling Information

Clad Mulling

Mull-58 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Round Top Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP6550525456586062646668707274 DP50767880828486 DP408890929496 DP3098

100102104106108 DP20110112114116118120

Tributary Width

Span

Page 59: General Mulling Information

Mull-59 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Round Top Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP65505254565860626466687072 DP 50747678808284 DP4086889092949698 DP30

100102104106108110112 DP20114116118120

Span

Tributary Width

Page 60: General Mulling Information

Clad Mulling

Mull-60 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Round Top Mulling - 4" and 6" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP65505254565860626466687072 DP50747678808284 DP4086889092949698 DP30

100102104106108110 DP20112114116118120

Tributary Width

Span

Page 61: General Mulling Information

Mull-61 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Direct Glaze Narrow Frame product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field

assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.

Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.

Products Included Narrow Frame (Contemporary) Direct Glaze

NOTE: Multi-High Multi-Wide Assemblies with any side that exceed 72” in either direction will be shipped with a temporary blockingaround the entire perimeter of the assembly to provide support during shipping and handling.

Certified Mull Installation Methods Jamb Screws

Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 62: General Mulling Information

Clad Mulling

Mull-62 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Direct Glaze Narrow Frame Mulling Types

Page 63: General Mulling Information

Mull-63 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Direct Glaze Narrow Frame Mulling Types (Continued)

Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls upto 2".

Page 64: General Mulling Information

Clad Mulling

Mull-64 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mulling - Standard Frame (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 PG50 DP504648505254 DP40565860 DP30626466 DP20687072747678808284 PG25868890929496

Span

Tributary Width

Page 65: General Mulling Information

Mull-65 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mulling - 3/8" Mull Reinforcement(Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP5046485052545658606264666870 DP40727476 DP 30788082 DP 208486889092949698100102104106108110112114116118120

Tributary Width

Span

Page 66: General Mulling Information

Clad Mulling

Mull-66 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mulling - 1" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP504648505254565860 DP40626466 DP30687072 DP2074767880828486889092949698

Span

Tributary Width

Page 67: General Mulling Information

Mull-67 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mulling - 2" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP504648505254565860 DP40626466 DP30687072 DP2074767880828486889092949698

Span

Tributary Width

Page 68: General Mulling Information

Clad Mulling

Mull-68 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP50464850525456 DP40586062 DP30646668 DP20707274767880828486889092

Span

Tributary Width

Page 69: General Mulling Information

Mull-69 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 '88-1203638404244 DP5046485052545658 DP40606264 DP30666870 DP2072747678808284868890929496

Span

Tributary Width

Page 70: General Mulling Information

Clad Mulling

Mull-70 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-120363840424446 DP50485052545658 DP40606264 DP3066687072 DP2074767880828486889092949698

100

Span

Tributary Width

Page 71: General Mulling Information

Mull-71 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-12036384042444648 DP5050525456586062 DP40646668 DP30707274 DP20767880828486889092949698

100102104

Span

Tributary Width

Page 72: General Mulling Information

Clad Mulling

Mull-72 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-12036384042444648 DP505052545658606264 DP40666870 DP30727476 DP207880828486889092949698

100102104106108

Span

Tributary Width

Page 73: General Mulling Information

Mull-73 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Direct Glaze Narrow Frame Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-120363840424446485052 DP505456586062646668 DP407072 DP3074767880 DP20828486889092949698

100102104106108110112114

Span

Tributary Width

Page 74: General Mulling Information

Clad Mulling

Mull-74 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Page 75: General Mulling Information

Mull-75 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Double Hung G2 product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field

assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.

Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around anexisting structure in the opening.

Products IncludedUltimate Double Hung G2Ultimate Double Hung G2 IZ3

Certified Mull Installation MethodsMasonry Clips

Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 76: General Mulling Information

Clad Mulling

Mull-76 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Double Hung G2 Mulling Types

Page 77: General Mulling Information

Mull-77 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Double Hung G2 Mulling Types (Continued)

Page 78: General Mulling Information

Clad Mulling

Mull-78 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Double Hung G2 Mulling Types (Continued)

Space Mulls and Solid Space Mulls areavailable in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls upto 2".

Page 79: General Mulling Information

Mull-79 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Double Hung G2 Mulling Types (Continued)

Space Mulls and Solid Space Mulls are also available in 1", 2", 3" and 4" widths.

Marvin provides interior mull trim for mulls up to 2".

Page 80: General Mulling Information

Clad Mulling

Mull-80 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - Standard Frame (Vertical) (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5 DP65

18 43.5

20 47.5 PG65

22 51.5 DP 50

24 55.5 DP40

26 59.5 DP30

28 63.5 DP20

30 67.5 PG50

32 71.5

34 75.5

36 79.5

38 83.5 PG 25

40 87.5

42 91.5

44 95.5

Tributary Width

Span

Page 81: General Mulling Information

Mull-81 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - Standard Frame (Horizontal) (Ribbon or Stacked Assembly)

Frame OM 21.25 25.25 29.25 33.25 37.25 41.25 45.25 49.25 53.25 57.25 61.25 65.25 69.25 73.25

51.188

53.188

55.188

57.188

59.188

61.188

63.188

65.188

67.188 DP65

69.188

71.188

73.188

75.188

77.188

79.188

81.188

83.188

85.188

87.188

89.188

91.188

93.188 DP50

95.188

97.188

99.188

101.188

103.188

105.188

107.188

109.188

111.188

113.188

115.188

117.188

119.188

121.188

123.188

125.188

127.188 DP50 DP45

129.188

131.188

133.188

135.188

137.188

139.188

141.188

143.188

145.188

147.188

149.188

151.188

153.188

Span

Tributary Width (combined unit heights/2)

Page 82: General Mulling Information

Clad Mulling

Mull-82 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - 1" LVL (Vertical) (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5 DP65

22 51.5

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5 DP50

36 79.5

38 83.5 DP40

40 87.5 DP 30

42 91.5

44 95.5

46 99.5 DP 20

48 103.5

50 107.5

52 111.5

54 115.5

56 119.5

58 123.5

60 127.5

Span

Tributary Width

Page 83: General Mulling Information

Mull-83 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - 2" LVL (Vertical) (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5 DP65

22 51.5

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5

36 79.5 DP50

38 83.5

40 87.5

42 91.5 DP40

44 95.5

46 99.5

48 103.5

50 107.5 DP30

52 111.5

54 115.5

56 119.5 DP20

58 123.5

60 127.5

Tributary Width

Span

Page 84: General Mulling Information

Clad Mulling

Mull-84 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5

22 51.5 DP DP65

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5 DP50

34 75.5

36 79.5

38 83.5 DP40

40 87.5

42 91.5

44 95.5 DP30

46 99.5 DP20

48 103.5

50 107.5

52 111.5

54 115.5

56 119.5

58 123.5

60 127.5

Tributary Width

Span

Page 85: General Mulling Information

Mull-85 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5 DP65

18 43.5

20 47.5

22 51.5 DP50

24 55.5

26 59.5 DP40

28 63.5 DP30

30 67.5

32 71.5

34 75.5 DP20

36 79.5

38 83.5

40 87.5

42 91.5

44 95.5

46 99.5

48 103.5

Tributary Width

Span

Page 86: General Mulling Information

Clad Mulling

Mull-86 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5 DP65

20 47.5

22 51.5

24 55.5

26 59.5

28 63.5 DP50

30 67.5

32 71.5 DP40

34 75.5

36 79.5

38 83.5 DP30

40 87.5

42 91.5 DP20

44 95.5

46 99.5

48 103.5

50 107.5

52 111.5

54 115.5

56 119.5

58 123.5

60 127.5

Span

Tributary Width

Page 87: General Mulling Information

Mull-87 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60

CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5

22 51.5 DP65

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5 DP50

36 79.5

38 83.5 DP40

40 87.5

42 91.5 DP30

44 95.5

46 99.5

48 103.5

50 107.5 DP20

52 111.5

54 115.5

56 119.5

58 123.5

60 127.5

Span

Tributary Width

Page 88: General Mulling Information

Clad Mulling

Mull-88 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5 DP65

22 51.5

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5 DP50

36 79.5

38 83.5

40 87.5 DP40

42 91.5

44 95.5

46 99.5 DP30

48 103.5

50 107.5

52 111.5 DP20

54 115.5

56 119.5

58 123.5

60 127.5Span

Tributary Width

Page 89: General Mulling Information

Mull-89 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5 DP65

22 51.5

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5 DP50

36 79.5

38 83.5

40 87.5 DP40

42 91.5

44 95.5

46 99.5 DP30

48 103.5

50 107.5

52 111.5 DP20

54 115.5

56 119.5

58 123.5

60 127.5Span

Tributary Width

Page 90: General Mulling Information

Clad Mulling

Mull-90 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Double Hung G2 Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5 DP65

22 51.5

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5

36 79.5 DP50

38 83.5

40 87.5

42 91.5

44 95.5 DP40

46 99.5

48 103.5

50 107.5

52 111.5 DP30

54 115.5

56 119.5 DP20

58 123.5

60 127.5

Span

Tributary Width

Page 91: General Mulling Information

Mull-91 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Glider Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Glider product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field

assembly of the mullion.Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available.

Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation of an existingstructure in the opening.

Products IncludedUltimate Glider

Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 92: General Mulling Information

Clad Mulling

Mull-92 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Glider Mulling Types

Page 93: General Mulling Information

Mull-93 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Glider Mulling Types (Continued)

Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls up to2".

Page 94: General Mulling Information

Clad Mulling

Mull-94 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Glider Mulling - Standard Frame Vertical (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2

30 35 1/2

36 41 1/2DP 50

40 47 1/2

46 53 1/2DP 40

50 59 1/2DP 30

56 65 1/2 DP 20

60 71 1/2

Span

Tributary Width

Page 95: General Mulling Information

Mull-95 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Glider Mulling - 3/8" MRF, 1" LVL, 2" LVL (Vertical) (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2

30 35 1/2

36 41 1/2

40 47 1/2

46 53 1/2DP 50

50 59 1/2

56 65 1/2

60 71 1/2

Span

Tributary Width

Page 96: General Mulling Information

Clad Mulling

Mull-96 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Glider Mulling - 3/8" Solid Space Mull (Vertical) (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2

30 35 1/2

36 41 1/2 DP 50

40 47 1/2

46 53 1/2

50 59 1/2DP 40

56 65 1/2DP 30

60 71 1/2DP 20

Tributary Width

Span

Page 97: General Mulling Information

Mull-97 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Glider Mulling - 1" Solid Space Mull (Vertical) (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2

30 35 1/2

36 41 1/2

40 47 1/2 DP 50

46 53 1/2

50 59 1/2

56 65 1/2

60 71 1/2DP 40 DP 30

Span

Tributary Width

Page 98: General Mulling Information

Clad Mulling

Mull-98 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Glider Mulling - 1" and 2" LVL (Horizontal) (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2

30 35 1/2

36 41 1/2

40 47 1/2

46 53 1/2DP 50

50 59 1/2

56 65 1/2

60 71 1/2

66 77 1/2 DP 40

70 83 1/2

76 89 1/2 DP 30

80 95 1/2

86 101 1/2

90 107 1/2DP 20

96 113 1/2

Tributary Width

Span

Page 99: General Mulling Information

Mull-99 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Glider Mulling - Solid Space Mull (2", 3", 4" and 6") (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2

30 35 1/2

36 41 1/2

40 47 1/2DP 50

46 53 1/2

50 59 1/2

56 65 1/2

60 71 1/2

Tributary Width

Span

Page 100: General Mulling Information

Clad Mulling

Mull-100 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Page 101: General Mulling Information

Mull-101 19972255Marvin Signature Collection Architectural Detail Manual

General Mulling Information

Ver 2019.3 2019-07-29

Multi-High, Multi-Wide MullingMarvin offers a variety of mull options for many of the Marvin window and door projects. Some mulls can be done in the factory.Others would need to be done in the field. Some mulls create a certified assembly according to third-party testing.

Marvin Mull Options:Marvin-SuppliedStandard Mull: Two or more units mulled together directly without any reinforcement or space between the frames.

Reinforcement may be required either vertically or horizontally to meet structural design pressure ratings. 3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or field

assembly of the mullion.Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull Reinforcement: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood. ◦ 1" and 2" widths are available from Marvin.

Space Mull: Non-continuous blocks of wood are used to space units apart. ◦ 3/8", 1", 2", 3", 4" and 6" widths are available.

Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation of an existingstructure in the opening.

Field Supplied and Applied Tube Mull: Tube aluminum or steel used to reinforce mulled assemblies. Flat Mull: Flat Steel or Aluminum used to reinforce mulled assemblies.

NOTE: Multi-High Multi-Wide Assemblies with any side that exceed 72” in either direction will be shipped with a temporary blockingaround the entire perimeter of the assembly to provide support during shipping and handling.

Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets

AnchoringSpecial considerations need to be made when installing mulled assemblies. Mullions create point loads that need to be

transferred to the rough opening. For Marvin standard, MRF, LVL, and space mulls, the ends of the mull need to be fastened oneach side of the splice with either jamb screws or brackets. Aluminum, steel and other structural mulls need to be anchoreddirectly to the rough opening or building structure.

Tributary and Span:Tributary Width - The area supported by the mullion. In the case of a vertical mull, this is equal to the sum of half of the width of eachunit on each side of the mull.Span - The length of the mullion

TributaryWidth

SpanTributary

Width

Span

Reinforcement

Rei

nfor

cem

ent

2 Wide 2 High 2 Wide 2 High

Multi-Wide Multi-High Mull

Page 102: General Mulling Information

General Mulling Information

Mull-102 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Multi-High Multi-Wide (Full Frame 3/8" Mull Reinforcement)Mullion Performance Charts

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88485052 DP 50545658 DP 40606264 PG66 DP 3068707274 PG 40 DP 2576788082 DP 2084868890 PG 5092949698

100102104106108 PG 25110112114116118120

Span

Tributary Width

Page 103: General Mulling Information

Mull-103 19972255Marvin Signature Collection Architectural Detail Manual

General Mulling Information

Ver 2019.3 2019-07-29

Multi-High Multi-Wide (Narrow Frame 3/8" Mull Reinforcement)

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 884850 DP 4052545658 DP 5060 DP 206264 DP 3066687072747678 DP 40808284

Tributary Width

Span

Page 104: General Mulling Information

General Mulling Information

Mull-104 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Multi-High Multi-Wide (Full Frame 1" LVL)

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 884850 DP 505254 DP 405658 DP 656062 DP 306466687072747678 DP 5080 DP 40 DP 30 DP 20828486889092949698

100102104106108110112114116118120

Span

Tributary Width

Page 105: General Mulling Information

Mull-105 19972255Marvin Signature Collection Architectural Detail Manual

General Mulling Information

Ver 2019.3 2019-07-29

Multi-High Multi-Wide 2" LVL (4 9/16")

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88485052545658 DP 65606264666870727476788082 DP 50848688 DP 4090929496 DP 3098

100102104106 DP 20108110112114116118120

Span

Tributary Width

Page 106: General Mulling Information

General Mulling Information

Mull-106 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Page 107: General Mulling Information

Mull-107 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Inswing French Door Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Inswing French Door product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

Products IncludedUltimate Inswing French DoorUltimate Inswing French Door IZ3

Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets

Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

Page 108: General Mulling Information

Clad Mulling

Mull-108 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Inswing French Door Mulling Types

Page 109: General Mulling Information

Mull-109 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Inswing French Door Mulling Types (Continued)

Page 110: General Mulling Information

Clad Mulling

Mull-110 19972255Marvin Signature Collection Architectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Inswing French Door Mulling - All Mull Types

NOTE: Includes UIFD with transoms of 1 frame and 1 sash (French Door Transoms, UDHG2 Transoms, Ultimate Direct GlazeTransoms or Ultimate Casement Transoms.

48 50 52 54 56 58 60 62.75

60.625 DP 50

72.625

PG 40

84.625

96.625 DP 30

110.719

DP 20

125.813

Span

Tributary Width

Page 111: General Mulling Information

Mull-111 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Outswing French Door Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Outswing French Door product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

Products IncludedUltimate Outswing French DoorUltimate Outswing French Door IZ3

Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

Page 112: General Mulling Information

Clad Mulling

Mull-112 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Outswing French Door Mulling Types

Page 113: General Mulling Information

Mull-113 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Outswing French Door Mulling Types (Continued)

Page 114: General Mulling Information

Clad Mulling

Mull-114 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Outswing French Door Mulling - All Mull Types

NOTE: Includes UOFD with transoms of 1 frame and 1 sash (French Door Transoms, UDHG2 Transoms, Ultimte Direct GlazeTransoms or Ultimate Casement Transoms.

48 50 52 54 56 58 60 62.75

60.625 DP 50

72.625

PG 40

84.625

96.625 DP 30

110.719

DP 20

125.813

Span

Tributary Width

Page 115: General Mulling Information

Mull-115 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Sliding French Door Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Sliding French Door product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

Products IncludedUltimate Sliding French DoorUltimate Sliding French Door IZ3

Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

Page 116: General Mulling Information

Clad Mulling

Mull-116 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Sliding French Door Mulling Types

Page 117: General Mulling Information

Mull-117 19972255Marvin Signature CollectionArchitectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Sliding French Door Mulling Types (Continued)

Page 118: General Mulling Information

Clad Mulling

Mull-118 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Sliding French Door Mulling - All Mull Types

NOTE: Includes USFD with transoms of 1 frame and 1 sash (French Door Transoms, UDHG2 Transoms, Ultimate Direct GlazeTransoms or Ultimate Casement Transoms.

48 50 52 54 56 58 60 62.75

60.625 DP 50

72.625

PG 40

84.625

96.625 DP 30

110.719

DP 20

125.813

Span

Tributary Width

Page 119: General Mulling Information

Mull-119 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Ultimate Sliding Patio Door Mull TypesMarvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Ultimate Sliding Patio Door product.

Mull Types:Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames. 2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

Products IncludedUltimate Sliding Patio Door

Certified Mull Installation MethodsMasonry Clips Jamb ScrewsStructural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

Page 120: General Mulling Information

Clad Mulling

Mull-120 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Ultimate Sliding Patio Door Mulling Types

Page 121: General Mulling Information

Mull-121 19972255Marvin Signature Collection Architectural Detail Manual

Clad Mulling

Ver 2019.3 2019-07-29

Section Details: Ultimate Sliding Patio Door Mulling Types (Continued)

Page 122: General Mulling Information

Clad Mulling

Mull-122 19972255Marvin Signature CollectionArchitectural Detail Manual

Ver 2019.3 2019-07-29

Ultimate Sliding Patio Door Mulling - All Mull Types

NOTE: Includes USPD with transoms of 1 frame and 1 sash (French Door Transoms, UDHG2 Transoms, Ultimate Direct GlazeTransoms or Ultimate Casement Transoms.

48 50 52 54 56 58 60 62.75

60.625 DP 50

72.625

PG 40

84.625

96.625 DP 30

110.719

DP 20

125.813

Span

Tributary Width

Page 123: General Mulling Information

Mull-123 19972255Marvin Modern Collection

Architectural Detail Manual

Mulling

Ver 2019.3 2019-07-29

Modern Casement Mull TypesThis document is a compilation of mulling options for the Modern Casement and Awning products.

Mull Types:Standard Mull: 2 or more units mulled directly together with the standard 1/2" x 2 1/4" Aluminum; requires standard interior and

exterior mull covers. 1/2" x 2 1/2” Steel: 2 or more units mulled directly together with 1/2" x 2 1/2” Flat steel; requires standard interior and exterior mull

covers. 1/2” x 4” Steel: 2 or more units mulled directly together with 1/2” x 4” Flat steel; requires standard exterior and 4” interior mull

cover. 2” x 4” Tube Steel: 2 or more units mulled together with 2” x 4” Tube steel creates a 1 1/2” space between the units requiring

different interior and exterior covers. 4 1/2” Stud Pocket: Exterior and interior covers to spread the units 4 1/2” apart.

NOTE: Aluminum mull supplied by Marvin. All other structure is supplied by others.

Products IncludedModern Casement Crank OutModern Casement Push OutModern Awning Crank OutModern Awning Push Out

Certified Mull Installation Methods Jamb Screws

Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.Tributary

Width

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 124: General Mulling Information

Mulling

Mull-124 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2019.3 2019-07-29

Section Details: Modern Casement/Awning Standard Mulling Types

Head Jamb and Sill Jambs

15/16" Dual Pane Glass

7/16″(11)

5 9/16″(141)

1 1/8″(29)

2 27/32″(73)

7/16″(11)

5 9/16″(141)

1 1/8″(29)

2 27/32″(73)

4 11/16″(119)

4 11/16″(119)

1 17/32″(39)

1 17/32″(39)

Page 125: General Mulling Information

Mull-125 19972255Marvin Modern Collection

Architectural Detail Manual

Mulling

Ver 2019.3 2019-07-29

Modern Casement/Awning Mulling - Standard Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96

60

62 DP40

64

66

68

70

72 PG40

74

76

78

80

82

84

86

88

90

92

94

96

98

100 DP40

102

Tributary Width

Span

Page 126: General Mulling Information

Mulling

Mull-126 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2019.3 2019-07-29

Page 127: General Mulling Information

Mull-127 19972255Marvin Modern Collection

Architectural Detail Manual

Mulling

Ver 2019.3 2019-07-29

Modern Direct Glaze Mull TypesThis document is a compilation of mulling options for the Modern Direct Glaze product.

Mull Types:Standard Mull: 2 or more units mulled directly together with the standard 1/2" x 2 1/4" Aluminum; requires standard interior and

exterior mull covers. 1/2" x 2 1/2” Steel: 2 or more units mulled directly together with 1/2" x 2 1/2” Flat steel; requires standard interior and exterior mull

covers. 1/2” x 4” Steel: 2 or more units mulled directly together with 1/2” x 4” Flat steel; requires standard exterior and 4” interior mull

cover. 2” x 4” Tube Steel: 2 or more units mulled together with 2” x 4” Tube steel creates a 1 1/2” space between the units requiring

different interior and exterior covers. 4 1/2” Stud Pocket: Exterior and interior covers to spread the units 4 1/2” apart.

NOTE: Aluminum mull supplied by Marvin. All other structure is supplied by others.

Products IncludedModern Direct Glaze PolygonModern Direct Glaze Rectangle

Certified Mull Installation Methods Jamb Screws

Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 128: General Mulling Information

Mulling

Mull-128 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2019.5 2019-10-28

Section Details: Modern Direct Glaze Standard Mulling Types

2 27/32"(72)

2 27/32"(73)

2 27/32"(73)

Direct Glaze RectangleJambs

Direct Glaze RectangleHead Jamb and Sill

2 27/32"(73)

2 27/32"(72)

2 27/32"(73)

2 27/32"(73)

Direct Glaze PolygonJambs

Direct Glaze - PolygonHead Jamb and Sill

2 27/32"(73)

Page 129: General Mulling Information

Mull-129 19972255Marvin Modern Collection

Architectural Detail Manual

Mulling

Ver 2019.3 2019-07-29

Modern Direct Glaze Mulling - Standard Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100-144

72

74

76

78 PG4080

82 DP4084

86

88

90

92 DP3594 DP3096

98

100

102

104 DP40106 DP30 DP25108 DP35110

112 DP20114

116

118

120

122

124

126

128

130

132

134

136

138

140

142

Tributary Width

Span

Page 130: General Mulling Information

Mulling

Mull-130 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2019.3 2019-07-29

Page 131: General Mulling Information

Mull-131 19972255Marvin Modern Collection

Architectural Detail Manual

Mulling

Ver 2021.1 2021-02-22

Modern Swinging Doors Mull TypesThis document is a compilation of mulling options for the Modern Inswing and Outswing Door products.

Mull Types:Standard Mull: 2 or more units mulled directly together with the standard 1/2" x 2 1/4" Aluminum; requires standard interior and

exterior mull covers. 1/2" x 2 1/2” Steel: 2 or more units mulled directly together with 1/2" x 2 1/2” Flat steel; requires standard interior and exterior mull

covers. 1/2” x 4” Steel: 2 or more units mulled directly together with 1/2” x 4” Flat steel; requires standard exterior and 4” interior mull

cover. 2” x 4” Tube Steel: 2 or more units mulled together with 2” x 4” Tube steel creates a 1 1/2” space between the units requiring

different interior and exterior covers. 4 1/2” Stud Pocket: Exterior and interior covers to spread the units 4 1/2” apart.

NOTE: Aluminum mull supplied by Marvin. All other structure is supplied by others.

Products IncludedModern Inswing DoorModern Outswing Door

Certified Mull Installation Methods Jamb Screws

Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 132: General Mulling Information

Mulling

Mull-132 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2021.1 2021-02-22

Section Details: Modern Inswing Door Standard Mulling Types

2 27/32"(72)

5 25/32"(147)

2 27/32"(73)

Direct Glaze Rectangle Sidelite /Inswing Door

Direct Glaze Rectangle OverInswing Door

2 27/32"(73)

5 25/32"(147)

4 7/32"(107)

4 7/32"(107)

5 25/32"(147)

Awning OverInswing Door

Casement Sidelite /Inswing Door

8 23/32"(222)

2 27/32"(73)

Inswing Door /Inswing Door

Page 133: General Mulling Information

Mull-133 19972255Marvin Modern Collection

Architectural Detail Manual

Mulling

Ver 2021.1 2021-02-22

Section Details: Modern Outswing Door Standard Mulling Types

2 27/32"(73)

5 25/32"(147)

5 25/32"(147)

2 27/32"(73)

2 27/32"(73)

7 1/8"(181)

Direct Glaze Rectangle OverOutswing Door

7 1/8"(181)

2 27/32"(73)

Awning OverOutswing Door

Direct Glaze Rectangle Sidelite /Outswing Door

Casement Sidelite /Outswing Door

2 27/32"(73)

8 23/32"(222)

Outswing /Outswing Door

Jambs

Page 134: General Mulling Information

Mulling

Mull-134 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2021.1 2021-02-22

Modern Swinging Doors Mulling - Standard Mull (Ribbon or Stacked Assembly)

* Inswing XX stacked mull excluded as it only meets PG30.** Inswing XX stacked mull with performance sill excluded as it only meets DP30.

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100-1447274767880 *DP40 (Performance Sill)82 *PG40 (Performance Sill)84 PG30 (Low Profile Sill)86889092 **DP3594 DP309698

100 DP30102 *DP40 (Performance Sill)104106108 **DP35 DP25110112114 DP20116118120122124126128130132134136138140142

Tributary Width

Span

DP30 (Low Profile Sill)

DP30 (Low Profile Sill)

Page 135: General Mulling Information

Mull-135 19972255Marvin Modern Collection

Architectural Detail Manual

Mulling

Ver 2019.3 2019-07-29

Modern Additional Steel Mull TypesThis document is a compilation of additional steel mulling options for the Modern window products.

Mull Types: 1/2" x 2 1/2” Steel: 2 or more units mulled directly together with 1/2" x 2 1/2” Flat steel; requires standard interior and exterior mull

covers. 1/2” x 4” Steel: 2 or more units mulled directly together with 1/2” x 4” Flat steel; requires standard exterior and 4” interior mull

cover. 2” x 4” Tube Steel: 2 or more units mulled together with 2” x 4” Tube steel creates a 1 1/2” space between the units requiring

different interior and exterior covers. 4 1/2” Stud Pocket: Exterior and interior covers to spread the units 4 1/2” apart.

NOTE: Aluminum mull supplied by Marvin. All other structure is supplied by others.

Products IncludedModern CasementModern Direct Glaze PolygonModern Direct Glaze Rectangle

Certified Mull Installation Methods Jamb Screws

Tributary and Span:Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Page 136: General Mulling Information

Mulling

Mull-136 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2021.6 2021-12-20

Section Details: Modern Additional Steel Mulling Types

NOTE: Mull Certification includes Direct Glaze, Casement/Awning, Inswing and Outswing door products.Tributary spans are limited based on individual maximum unit sizeStandard Aluminum Mull provided by Marvin. All other structure supplied by others.

2 27/32"(72)

2 27/32"(73)

1/2" X 2 1/4" Aluminum Mull

2 27/32"(72)

2 27/32"(73)

1/2" X 4" Flat Steel Mull

2 5/8"(67)

4 11/32"(110)

4 11/32"(111)

2" X 4" Tube Steel Mull

2 1/8"(54)

1 1/2"(38)

1 1/2"(38)

2 27/32"(72)

2 27/32"(73)

1/2" X 2 1/2" Flat Steel Mull

Page 137: General Mulling Information

Mull-137 19972255Marvin Modern Collection

Architectural Detail Manual

Mulling

Ver 2021.6 2021-12-20

Section Details: Modern Additional Steel Mulling Types

NOTE: Mull Certification includes Direct Glaze, Casement/Awning, Inswing and Outswing door products.Tributary spans are limited based on individual maximum unit sizeStandard Aluminum Mull provided by Marvin. All other structure supplied by others.

5 5/8"(143)7 11/32"

(186) 7 11/32"(187)

4 1/2" Stud Pocket Mull With Wood

5 1/8"(130)

3 1/2"(89)

7 29/32"(201)

4 1/2"(114)

5 5/8"(143)7 11/32"

(186) 7 11/32"(187)

4 1/2" Stud Pocket Mull With Tube Steel

5 1/8"(130)

3 1/2"(89)

7 29/32"(201)

4 1/2"(114)

Page 138: General Mulling Information

Mulling

Mull-138 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2019.6 2019-12-16

Modern Window Steel Mulling - 1/2" x 2 1/2" Flat Steel Mull (Ribbon or Stacked Assembly)

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144

60

62

64

66

68

70

72

74

76

78 DP4080

82

84

86 PG50 (Certified)88 CW40 (Certified)90

92

94

96

98

100

102 DP35104

106 DP30108

110 DP35112 DP25114 PG50 (Certified) DP30116 CW40 (Certified)118

120

122

124

126

128 DP35130

132

134

136

138

140

142

144

Tributary Width

Span

Page 139: General Mulling Information

Mull-139 19972255Marvin Modern Collection

Architectural Detail Manual

Mulling

Ver 2019.6 2019-12-16

Modern Window Steel Mulling - 1/2" x 4" Flat Steel Mull (Ribbon or Stacked Assembly)

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144

60

62

64

66

68

70

72

74

76

78 DP4080

82

84

86 PG50 (Certified)88 CW40 (Certified)90

92

94

96

98

100

102 DP35104

106 DP30108

110 DP35112 DP25114 PG50 (Certified) DP30116 CW40 (Certified)118

120

122

124

126

128 DP35130

132

134

136

138

140

142

144

Tributary Width

Span

Page 140: General Mulling Information

Mulling

Mull-140 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2019.6 2019-12-16

Modern Window Steel Mulling - 2" x 4" Tube Steel Mull (Ribbon or Stacked Assembly)

36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144

60

62

64

66

68 PG40 (Certified)70 CW40 (Certified) DP4072

74

76

78

80

82

84

86

88

90

92

94

96

98

100

102

104

106 DP35108

110

112

114

116

118

120

122

124

126

128

130

132

134

136 DP40 DP35 DP30 DP25138

140

142

144

146

148

150

152

154

156

158

160

162

164

166

168

170

172

174

176

178

180

182

184

186

188

190

192

Tributary Width

Span

Page 141: General Mulling Information

Mull-141 19972255Marvin Modern Collection

Architectural Detail Manual

MullingModern Window Steel Mulling - 1/2" x 2 1/2" Flat Steel Mull (Multi-High, Multi-Wide Assembly)

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144

60 DP4062 DP35 DP3064

66 PG50 (Certified)68 CW40 (Certified)70

72

74

76

78 DP2580 DP4082 DP3084 DP3586

88

90

92

94

96

98

100

102

104

106

108

110

112

114

116

118

120

122

124

Tributary Width

Span

Page 142: General Mulling Information

Mulling

Mull-142 19972255Marvin Modern Collection

Architectural Detail Manual

Modern Window Steel Mulling - 1/2" x 4" Flat Steel Mull (Multi-High, Multi-Wide Assembly)

36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144

60

62

64

66

68 DP4070

72

74

76

78

80 PG40 (Certified)82 CW40 (Certified)84

86

88

90

92 DP3594

96

98

100

102

104

106

108

110

112

114

116

118 DP40 DP35 DP30 DP25120

122

124

126

128

130

132

134

136

138

140

142

144

146

148

150

152

154

156

158

160

162

164

166

168

170

172

174

Tributary Width

Span

Page 143: General Mulling Information

Mull-143 19972255Marvin Modern Collection

Architectural Detail Manual

MullingModern Window Steel Mulling - 2" x 4" Tube Steel Mull (Multi-High, Multi-Wide Assembly)

36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144

60

62

64

66

68 PG40 (Certified)70 DP4072

74

76

78

80

82

84

86

88

90

92

94

96

98

100

102

104

106 DP35108

110

112

114

116

118

120

122

124

126

128

130

132

134

136 DP40 DP35 DP30 DP25138

140

142

144

146

148

150

152

154

156

158

160

162

164

166

168

170

172

174

176

178

180

182

184

186

188

190

192

Tributary Width

Span

Page 144: General Mulling Information

Mulling

Mull-144 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2021.1 2021-02-22

Modern Swinging Doors Mulling - 2 1/2" Steel Mull (Ribbon or Stacked Assembly)

* Inswing XX stacked mull excluded as it only meets PG30.** Inswing XX stacked mull with performance sill excluded as it only meets DP30.

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 1446062646668707274

76 *PG40 (Performance Sill)78 PG30 (Low Profile Sill) *DP4080 DP3082 Availability of CW performance on O configuration only84

86

889092949698100

102 **DP35104106108

110 **DP35112 DP25114 *PG40 (Performance Sill)116 PG30 (Low Profile Sill)118120122124126

128 **DP35 Max sizes based on 144" X 120" O door + DG with 141.375 long dimension130 Vertical Mull132 Max Span = 120" (certified height)134 Max Tributary = 144" ((2)144" wide O units)136 Horizontal Mull138 Max Span = 144" (widest O)140 Max Tributary = 130.6875" (120" tall door + 141.375 tall DG)142144

Tributary Width

Span

DP30

Page 145: General Mulling Information

Mull-145 19972255Marvin Modern Collection

Architectural Detail Manual

Mulling

Ver 2021.1 2021-02-22

Modern Swinging Doors Mulling - 4" Steel Mull (Ribbon or Stacked Assembly)

* Inswing XX stacked mull excluded as it only meets PG30.** Inswing XX stacked mull with performance sill excluded as it only meets DP30.

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 14460626466687072747678808284 *DP4086 *PG40 (Performance Sill) DP3088 PG30 (Low Profile Sill)90929496 Availability of CW performance on O configuration only98100102104106108110112114116118120122 **DP35124

126

128

130 DP30132

134136138140 DP25141

Tributary Width

Page 146: General Mulling Information

Mulling

Mull-146 19972255Marvin Modern Collection

Architectural Detail Manual

Ver 2021.1 2021-02-22

Modern Swinging Doors Mulling - 2" x 4" Tube Steel Mull (Ribbon or Stacked Assembly)

* Inswing XX stacked mull excluded as it only meets PG30.** Inswing XX stacked mull with performance sill excluded as it only meets DP30.NOTE: Tube Steel not recommended with Operating Outswing Door mulls.

36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 ## ## ## ## ## ## 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 1446062646668 *PG40 (Performance Sill)70 PG30 (Low Profile Sill) *DP4072 DP3074767880 Availability of CW performance on O configuration only828486889092949698

100102104

106 **DP35108110112114116118120122124

126 *DP40 **DP35 DP30 DP25128 DP30130132134

136138140142144

Tributary Width

Span

Page 147: General Mulling Information

Mull-147 19972255Marvin Modern Collection

Architectural Detail Manual

MullingModern Door Steel Mulling - 1/2" x 2 1/2" Flat Steel Mull (Multi-High, Multi-Wide Assembly)

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 144

60 *DP4062 **DP35 DP3064

66 *PG40 (Performance Sill)68 PG30 (Low Profile Sill)70 Availability of CW performance on O configuration only72

74

76

78 DP2580 *DP4082 DP3084 **DP3586

88

90

92

94

96

98

100

102

104

106

108

110

112

114

116

118

120

122

124

Span

Tributary Width

Page 148: General Mulling Information

Mulling

Mull-148 19972255Marvin Modern Collection

Architectural Detail Manual

Modern Door Steel Mulling - 1/2" x 4" Flat Steel Mull (Multi-High, Multi-Wide Assembly)

36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 14460626466

68 *DP4070 DP3072747678

80 *PG40 (Performance Sill)82 PG30 (Low Profile Sill)848688 Availability of CW performance on O configuration only90

92 **DP35949698

100102104106108110112114116

118 *DP40 **DP35 DP30 DP25120 DP30122

124

126

128130132134136138140142144146148150152154156158160162164166168170172174

Tributary Width

Span

Page 149: General Mulling Information

Mull-149 19972255Marvin Modern Collection

Architectural Detail Manual

MullingModern Door Steel Mulling - 2" x 4" Tube Steel Mull (Multi-High, Multi-Wide Assembly)

36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 128 130 132 134 136 138 140 142 14460626466

68 *PG40 (Performance Sill)70 PG30 (Low Profile Sill) *DP4072 DP3074

767880828486889092949698100102104

106 **DP35108110112114116118120122124126128130132134

136 *DP40 **DP35 DP30 DP25138 DP30140142144146148150152154156158160162164166168170172174176178180182184186188190192

Tributary Width

Span