GENERALPlant Resource Manager (PRM®) is an asset management software tool for the digital network era. The PRM software efficiently manages and supports maintenance work of field devices, which contributes in reducing total cost of ownership (TCO) of an industrial plant.The PRM software packages support intelligent devices such as Foundation™ fieldbus, HART, PROFIBUS, and ISA100.11a field wireless devices as well as conventional analog devices.
PRODUCT OVERVIEWPlant Resource Manager (PRM) consists of the following components:
•Centralizeddeviceinformationsuchasdevicemaster,inspectionschedulesandrecords,user-createdelectronicdocuments, and parts lists are generated and managed as database.
l PRM client•Devicenavigatorwindowsinhierarchytreeviewareprovidedformonitoringandmanagingfielddevices.•Automaticdevicerecognitionandregistration(plug&play)areperformedbyusingfulldigital,bi-directional,fielddigitalnetworkssuchasFoundationfieldbus,HART,PROFIBUS,andISA100.11a.Monitorsdevicehealthstatuswithmaintenancealarmsandcommunicationerrors.WithPRMAdvancedDiagnosticFunction,thePRMalsoperformsdevicestatusdiagnosis,deviceparametersettingusingdevicediagnostictools(i.e.DeviceViewer,DTMWorks,andDDmenu).
•Maintenancemarksareakindofflagstobeassignedtodevicesforsettingandcheckingmaintenancestatus.Themaintenancemarkiconisdisplayeduponsetting,andenablestotemporarilychangedeviceaccesslevel.ThemaintenancemarkscanalsobelinkedwithCENTUM’soperationmarkssothatthemaintenanceengineersandoperators can share the same information and coordinate their work.
l Field communications serverThissoftwareistosetandacquirefielddevicedataonline.Thefieldcommunicationserverprovidesinformationsuchasdevicestatusmonitoring,deviceadjustment,anddevicediagnosistothemaintenancesupportapplication.
Connecting with field devicesFollowingmethodsareavailabletoconnectwithfielddevices.•FoundationfieldbusCommunicationModulesforCENTUMVP/CS3000•AI/AOmodulesoranalogdigitalI/OmodulewithHARTcommunicationforCENTUMVP/CS3000•PROFIBUS-DPcommunicationmoduleforCENTUMVP•FoundationfieldbusCommunicationModulesforSTARDOM•AI/AOmoduleswithHARTcommunicationforSTARDOM•PROFIBUScommunicationmoduleforSTARDOM•AI/AOmodulesoranalogdigitalI/OmoduleswithHARTcommunicationforProSafe-RS•NI-FBUScard•3rdpartyHARTmultiplexers(PepperandFuchs,MTL,ELCON,orSTAHL)•3rdpartyPROFIBUScommunicationdevices(CommunicationDTM/GatewayDTMcommunications)•FieldWirelessAccessPointandFieldWirelessManagementStation(CommunicationDTM/GatewayDTMcommunications)
l Multiple server switchoverPRMcanmanagefielddevicesthatarecontrolledbyaCENTUMVP/CS3000,ProSafe-RS,orSTARDOMproject.PRMcanalsomonitoralarge-scaleprojectwhichisgeographicallydistributedinremotelocationsatasinglelocation.Forthelarge-scaleprojectwheretensofthousandsoffielddevicesareinstalled,dividingthemintomultiplenumbersofPRMserversisinevitable.PRM’smultipleserverfunctionenablestoselectwhichPRMserverisreferredtobyaPRMclient.Inthisway,asinglePRMclientcanmonitorseveralPRMservers.
l PRM advanced diagnosis server function (optional)Thisseverfunctionprovidesanenvironmentforexecutingdiagnosticalgorithmsbyutilizingfielddeviceparameters.ThediagnosticalgorithmapplicationcanbeconfiguredbyusingthePRMadvanceddiagnosticsoftwaredevelopmentkit(PAA-developmentkit)withoutanyadditionalsoftwareprogram.Bymonitoringparametersandprocessdatatransmittedfromfielddevices,thePRMadvanceddiagnosisserverfunctionconfiguresandexecutesdiagnosisofthedevicesandassets.Formoredetails,refertotheGS“PRMadvanceddiagnosisserver”(GS33Y05Q21-32E).
l PST scheduler package (optional)PST(*1)standsforapartialstroketest.ThePSTschedulerschedulesPST,automaticallyexecutesPSTinaccordancewiththeschedule,andmanagestheresultsinunifiedmanners.FunctionstomodifytheplannedschedulesandswitchPSTexecutionfromautomatictomanualareavailable.Fordetails,refertotheGS“PSTSchedulerPackage”(GS33Y05Q23-32E).
l Interface for Computerized maintenance management system (optional)PRMhasaninterfacewithMaximoAssetManagement,acomputerizedmaintenancemanagementsystem(CMMS),fromIBMSoftware,Inc.Withthisinterface,PRMcanprovidemaintenanceinformationtothemaintenancemanagement system online.Fordetails,refertotheGS“InterfaceforCMMS”(GS33Y05Q20-32E).
l Interface for GE Energy’s System 1® (optional)PRMcanprovideasinglemonitoringwindowfordiagnosisofturbines,rotatingequipmentandreciprocatingequipmentundermanagementbyGEEnergy’sSystem1optimizationanddiagnosticssoftwareplatforminadditiontofielddevicessuchaspressuretransmittersandflowmeters.Fordetails,refertotheGS“InterfaceforGEEnergy’sSystem1”(GS33Y05Q22-32E).
SYSTEM CONFIGURATIONPRMmanagesinformationoffielddevicesbythePRMserverasaunit.ThePRMsystemcanbeconfigurableinscalableways–aminimumsystemconsistsofaPRMserver,aFieldcommunicationsserver,andaPRMclientallresidedinasinglecomputer,oralargesystemwithmultipleclients.ExamplesofPRMsystemconfigurationsareshown in this section.
l System configurationCENTUM VP/CS 3000
CENTUM HIS/ENG
PRM client
PRM server
Ethernet
Ethernet
Control network
HART devices
AnalogHART I/O module
ALP121(*2)
PROFIBUS-DP
PROFIBUS devices
FieldMate
ALF111
FCS FCS FCS
F01E.ai
Terminator
YFGW410Field wirelessmanagementstation
FOUNDATION fieldbusPower supply + Terminator
YFGW410Field wirelessmanagement
station
Firewall
L3 switch
Wide-area field network
Field wireless devicesHIS: Human interface stationENG: FCS: Field control stationALF111: FOUNDATION fieldbus communication module
FF-H1 devices
Field wireless devices
(*1)
ALE111
ALE111: Ethernet communication moduleALP121: PROFIBUS-DP communication module
Field communications server
Engineering station
TM1READY
FUSE RL1 CN1 (PSU-L) TM2 100-120V AC
CN2 (PSU-R)
TM1READY
FUSE RL1 CN1 (PSU-L) TM2 100-120V AC
CN2 (PSU-R)
TM1READY
FUSE RL1 CN1 (PSU-L) TM2 100-120V AC
CN2 (PSU-R)
Figure CENTUM VP System Configuration (for FIO)Note:APRMserver,aPRMClientandaFieldCommunicationsServercanrunonasinglecomputer. APRMclientcanrunonthesamecomputerwhereHIS/ENGisalreadyinstalled. APRMserveroraFieldcommunicationsservercannotrunonthesamecomputerwhereHIS/ENGisalreadyinstalled.*1: ProcessdataanddiagnosisstatuscanbedisplayedonanHIS. AsforconfigurationofISA100.11afieldwireless,refertotheGS“Fieldwirelesssystemoverview”(GS01W01A01-01EN).*2: ALP121issupportedbyCENTUMVPR5.02orlaterrevision.
VDS: STARDOM versatile data serverHMI: Human machine interfaceFCU: STARDOM autonomous controller (field control node)FCJ: STARDOM autonomous controller (field control junction)NFLF111: FOUNDATION fieldbus communication moduleNFAI***: Analog I/O modules (with HART communication function)NFLP121: PROFIBUS-DP communication module
Notes for STARDOM configuration:PRMpackagescannotbeinstalledonacomputerwhereSTARDOMversatiledataserver(VDS)isalreadyinstalled.InstallingtheFCN/FCJOPCserverforWindowspackageonadifferentcomputerseparatelyfromthePRMpackagesis recommended.RefertothetablebelowforcombinationofthesoftwarerevisionnumberswheninstallingFCN/FCJOPCserverforWindowspackageonthesamecomputerwiththePRM.Thosecombinationsotherthanshownhere,FCN/FCJOPCserverforWindowsmustbeinstalledonadifferentcomputerseparatelyfromthePRMpackages.
FCN/FCJ OPC server for Windows PRM
Revision R1.90 R3.02
R2.20 R3.03, R3.04
R3.01 to R3.10 R3.05
– R3.10
R3.20 to R3.40 R3.11
– R3.12 or later
Upto100unitsofFCN/FCJcontrollerscanbeconnectedtoaFieldcommunicationsserver.Asforalarge-scalesystem,multi-serverfunctionshouldbeusedtodividethenumberofcontrollersconnectedtoaPRMserverbythegroup of 100 units or less.
Communication with HART devices via multiplexerPRMcancommunicatewithHARTdevicesviaaHARTmultiplexerconnectedtotheserialportsoftheFieldcommunicationsserver.
Ethernet
Field communications server
PRM client
HART devices
HART devices
HART devices
PRM server
Control network
Analog I/O module
F05E.ai
FCS
HIS/ENG
HART multiplexer(3rd party)
HART multiplexer(3rd party)
RS-485/ Ethernet converter
HART devices
HART digital signals
4 - 20 mA
TM1READY
FUSE RL1 CN1 (PSU-L) TM2 100-120V AC
CN2 (PSU-R)
Figure Serial port connection via HART multiplexer (Parallel connection and two-way data flow)Note:APRMserver,aPRMclient,andaFieldcommunicationsservercanrunonasinglecomputer.
l Device navigatorFourdifferentviews-plantview,networkview,classview,signalview,andcustomview–areprovided.Eachviewdisplaysdevicesinaplantintheformofaplanthierarchytreeview,intheWindowsexplorer-likeformat.Intheseviews,devicestatusanddevicepriority are shown with icons so that operators are able tojudgethemaintenancepriorityofthedevicesataglance.Wheretherearedeviceswithunacknowledgedmaintenance alarms, unacknowledged alarm icons are displayed.Useraccessescanberestrictedbasedonthedevicenavigatorhierarchy,whichpreventsanunauthorizedpersonnelfromoperatingdevicesbymistake.
Class viewFielddevicesinatreeviewbyvendors,models,andrevisionsaredisplayed.Userscanidentifythestatusofhowsparedevicesareusedwhiledevices-in-usearefailedorundermaintenance.Devicetemplatescanbecreated using this function.
Signal viewBasedonthefielddevicediagnosisresult,fielddeviceswhichareeitherhavingoperationalproblemorrequiringmaintenancearedisplayedinatablesortedbythestatussignals.Onlythefielddevicesthatrequiremaintenance can be shown on the list sorted by the category,whichenablestomaintainthefielddevicesknowing the priority. Four status signals - failure, check function,outofspecification,andmaintenancerequired-areprovidedbasedontheNE107recommendedbyNAMUR.
Custom viewUser-createdviewscanbecreatedanddisplayedinthehierarchicalstructure.Fielddevicescanbecategorizedby persons in charge of maintenance, inspection or replacement schedule, operation or failure status, and so on.
l Maintenance mark Maintenance marks are assigned electronically to each devicetoletmaintenanceengineersidentifystatusofadevice.ThemaintenancemarksareenabledtolinkwithCENTUM’soperationmarkssothatmaintenanceengineers and operators can share the same information and coordinate their work.
l Maintenance alarm functionAmessagesystemtonotifymaintenanceinformationandinformationnecessaryforfielddevicemaintenanceto all the maintenance engineers. The information contains not only messages generated by the fielddevices,butalsoattributessuchasmessageinformation,phenomenon,causes,andactions.Alarmsgeneratedbydiagnosticfunctionscanalsobedeliveredto the users.
Message acquisitionMessagesfromfielddigitaldevicesaswellaseventmessagesgeneratedbyCENTUM,STARDOMProSafe-RS,andthird-partysystemsareacquired.User-definedinformationsuchaseventpriorities,objectiveinformation,phenomenon,causes,andactionsareautomaticallyaddedtotheoriginaleventmessages, which are acknowledged as maintenance alarms,andpassedontothefilteringfunction.
Device patrolFielddevicestatusprovidedbydevice’sself-diagnosticsareacquiredtogeneratemaintenancealarmswiththeuser-definedattributessuchasmessagepriorities,objectiveinformation,phenomenon,causes, and actions. These maintenance alarms are handedovertothefilteringfunction.Dataacquisitionisperformed periodically or on demand. Information from deviceswhichdonotgeneratealarmmessagesbythemselvescanalsobeacquired.
l Maintenance information managementPRMactsasacentraldatabasefordevicemaintenance information.
Device masterAlistoffielddevicesaregeneratedandmanagedwithalltherelevantinformation.Thelistofalltheregisteredfielddevicesanddetailedinformationoftheindividualfielddevicescanbedisplayed.Fielddeviceswithfieldcommunication function can be added automatically tothedevicelistbyplug&playwhenthedevicesarerecognized.
Inspection memoDetailsofinspection,maintenance,andservicingtasksperformedonadeviceorataplantareincluded.Comments and remarks by maintenance engineers duringservicingormaintenancecanalsobeincludedastheservicelogs.
Parts listComponents and attribute information of parts whichcomposeofafielddeviceareincluded.AsforYokogawafielddeviceswithdigitalnetworkcommunication function, dedicated templates are provided.
Document linksFielddevicerelateddocumentssuchasplantstructures(e.g.P&IDandcontroldrawings),componentsparepartslist,onlineinstructionmanuals,anddeviceimages are freely allocated and enables users to accessthembythedevicetagnameaskeys.ThesedocumentscanbestoredinadocumentserveronanEthernetandaccessedbyURLaddresses.
l Audit trail managementHistoricalrecordsofPRMoperations,inspectionrecords,andeventinformationgeneratedbythemaintenance alarm function are managed and displayed on the PRM client. These historical records canbeshowninchronologicalorders,devicepriority,or message priority. The records can also be displayed filteringbythedeviceIDsordevicetagnames.
l Adjustment and diagnostic functionsOnlineadjustmentanddiagnosticfunctionsoffielddevicesaresupported.
Parameter tuning and comparisonDeviceparameterscanbesetanddisplayedonline.ThisfunctionenablesPRMtocomparethesavedparameterswithactualones.Theparametersetvaluesaresavedaslogs.Thedevicedatacanbeuploadedand stored to the database at any time. PRM also supports one-time uploading of all the connected devices.
APLUG-INapplicationtodisplayresultsoffielddeviceself-diagnosis.Mostofthefielddevicesholdself-diagnosticresultsasthevendor-specificparameters.TheDeviceViewerreadsthoseself-diagnostic results and displays them in user-friendly ways.TheDeviceVieweralsodisplaysfielddeviceinformationwhichisusuallydisplayedontheLCDofthedevices,whichenablesuserstoremotelymonitorthedevicesconnectedtoPRMwithoutviewingthelocalLCDs.
Calibration data managementThedevicecalibrationdataaremanagedandmaintained by the PRM. Calibration results, differences,andjudgment(passorfail)areregisteredto the database and displayed on a PRM client. The calibrationdataapprovalfunctionallowsonlytheauthorizedpersontomodifythecalibrationdataonceitisapproved.Themodificationofthecalibrationdatais recorded as an operation history by the historical operation management function.When the documenting calibrator is used, the calibrationdatacanbeupload/downloadviacommunication. The calibration results are automaticallysavedintothedatabase.Thedocumentingcalibratorconnectionisprovidedasoptional.
l Other functionsBrowserAspecificdevicecanbesearchedbythedeviceattributesinformationaskeywordssuchasdeviceID,devicetagname,devicetagcomments,blockname,and parameters.
SecurityFormaintainingfielddevices,onlytheauthorizedpersonnel is allowed to access PRM or the scope of workislimitedsoastopreventtroublescausedbymis-operations from happening or secure system safety.Ausernameisusedtoidentifytheuserandtheusername is recorded to the operation records. The user operationsanditsprivilegesarerestrictedbytheusergroup where they belong.Byusingthedevicesecurityfunction,fielddevicescanbedisplayedonthedevicenavigatoronlyforthespecifiedusergroup.
ExportAdevicelist(deviceID,devicetagname,devicetagcomments, etc.) registered to the PRM database can beexportedasatextfileinCSVfileformatsothatthePRM’sdeviceinformationcanbeutilizedbyothersoftware such as asset management.
Self-documentationThe data stored in the PRM database can be output inadocumentformattolettheusersmanagedevice-related information electronically and print out on demands. The information displayed on each window can also be printed out in a format to be used as a maintenance report.The following printing properties can be edited.•Printingrange•Tableofcontents•Header/footer•Coverpage
PLUG-IN applicationsAPLUG-INapplicationisYokogawaorathird-partysoftware program that runs on a PRM client computer. FielddevicesandPRMdatabaseareaccessedviaPLUG-INapplicationlibrary.
*1: PLUG-INValveNaviisasoftwareprogramforYVP110valvepositionercompliedwithFoundation fieldbus to calibrate and execute advanceddiagnosticsusingsignaturefunctionsuchasdevicediagnosis.ItsfunctionsareequivalenttoYVP20S,astand-alonetypeValveNavi.FormoredetailsoftheValveNavifunctions,pleaserefertotheGS"YVPManagementSoftware"(GS21B04C50-01E).
PRM system back-up scriptUserscanbackupandrestorethePRMdatabasedontheuserenvironment.Registryinformation,PRMdatabase,advanceddiagnosisdatabaseandsooncanbe backed up.
l Relevant solutionField asset KPI reportThistoolprovidesservicesolutionsforplantequipmentsuch as status monitoring, performance diagnosis, andefficiencyimprovements.Usingtheintelligentfunctionsofthefielddevices,thetoolacquiresdevicestatus,availability,numberofalarms&events,andtheir rankings to automatically create the KPI report. Thereporthelpsoperatorstograsptheoverallstatusofthefielddeviceswiththeirowneyes.TheKPI report also helps make maintenance plans with prioritiesdependingonthedeviceconditions.Fordetails,refertotheGS“FieldAssetKPIReport”(GS43D02S03-02EN).
l Supported functionsPRM’ssupportedfunctionsdifferbythekindsoffielddevices.Therelationshipbetweenthefielddevicesandtheircomplied functions are as shown below.
Table Supported Functions
Function Conventional
Devices(*1)
Foudation fieldbus
HART (*2)
ISA100.11a(*3)
PROFIBUS(*4)
Devicenavigationfunction
Plantview XX XX XX XX XXNetworkview — XX XX XX XXClassview XX XX XX XX XXSignalview — XX XX XX XXCustomview XX XX XX XX XX
Maintenance mark XX XX XX XX XX
Maintenance information management functions
Devicemaster XX XX XX XX XXPlug&Play — XX XX XX XXRegister from host fileset — XX X — X
Inspection memo XX XX XX XX XXInspection schedule XX XX XX XX XXParts list XX XX XX XX XXLinktodocument XX XX XX XX XX
Audittrailmanagement function
Parameter history — XX XX XX XXInspection memo history XX XX XX XX XX
Operationhistory XX XX XX XX XXDeviceeventmessage — XX XX — XX(*5)
Adjustmentanddiagnosis
Parameter tuning and comparison — XX XX XX —
Status display — XX XX XX XXTool — XX XX XX XXCalibration — XX XX — —
Maintennancealarm
Plantview — XX XX XX XXNetworkview — XX XX XX XXClassview — XX XX XX XXCustomview — XX XX XX XX
Otherfunctions
Browser XX XX XX XX XXSecurity XX XX XX XX XXPrinting XX XX XX XX XXPLUG-INapplication — XX XX XX —FieldMate synchronization XX XX XX XX XX
XX: Supported X: Partly supported —: Not applicable
MULTIPLE SERVER SWITCHOVERAssetmanagementofmultipleplantscanbeintegrallymanaged.A“server-set”concepthasbeenintroducedandenablesaPRMclienttoswitchfromaFieldcommunicationsserverandaPRMservertootherservers.Auserhastodefinetheserver-setbeforeuse.Withthisswitchoverfunction,aPRMclientmanagesallthedevicemanagementinformation of the multiple plants at a single location.
Main memory size required by Windows OSThemainmemorysizesrequiredbytheapplicableWindowsOSareasdescribedasbelow:
Table Required main memory size by Windows OS
Memory Size OS
Minimum memoryrequirement
Recommended(for better performance)
Windows Vista Business Edition SP2 512MB 1GBormore
Windows Server 2008 Standard Edition SP2 or Windows Server 2008 R2 Standard Edition SP1 512MB 2GBormore
Windows 7 Professional Edition SP1 2GB 4GBormore
PRM serverCPU:Refertothetablebelow.Main memory: Refer to the table below.Harddiskspace:Refertothetablebelow.Peripheraldevices:DVD-ROMdrive Ethernet cardDisplayresolution/colors:256colorsormore
Table PRM server hardware requirements (without Advanced diagnosis server)
Number of field devices300 units or less 1000 units or less 3000 units or less
Field communications serverCPU:PentiumIII1GHzorhigherForconnecting2000devicesormore,2.8GHzorhigherisrequired.Main memory: Refer to the table below.Harddiskspace:1GBormoreCommunication unit: Refer to the table below.Peripheraldevices:DVD-ROMdriveDisplayresolution/colors:256colorsormore
Table Hardware requirements for Field communications server
Connecting with CENTUM VP/CS
3000 or ProSafe-RSConnecting with
STARDOM
Connecting via NI-FBUS simplified
system for Foundation fieldbus
Connecting withsimplified system
for HART device or HART multiplexer
Connecting viacommDTM/
gatewayDTM
Main memory (*1)(*2)
•FCS/SCS1-16units(100+80 x number ofFCS/SCS)MBormore recommended
•FCN/FCJ1-16units(100+60 x number ofFCN/FCJ)MBormore recommended 256MBormore
required512MBormorerecommended
256MBormorerequired512MBormorerecommended
256MBormorerequired{30+(commDTM/gatewayDTMmainmemory)×(No. of node)}MBormorerecommended
•FCS/SCS17-44units (1380+10 x (numberofFCS/SCS-16))MBormore recommended
•FCN/FCJ17-100units (1060+5 x (numberofFCN/FCJ-16)MBormorerecommended
Communication devices
Ethernet card Control bus interface card Control network interfacecard(VF702,VI702)
OPC server (for STARDOM system)CPU:Pentium300MHz,400MHz,orfasterrecommendedMainmemory:256MB,512MB,ormorerecommendedDiskcapacity:Minimum1GBoffreespace.Ethernetcard:100BASE-TX,10BASE-T,10BASE-5
R3.31.00/R3.31.10 N/A N/A N/A N/A N/A N/A N/A X X X X
SP:Servicepack X:Applicable N/A:Notapplicable
PRM serverInternet Explorer 8.0, 9.0, or 11.0MicrosoftSQLServer2012SP3(32-bit)isusedasadatabasesoftwareandisincludedinthesoftwaremedia(SSSSM02) for the Plant Resource Manager. (R3.31.10)
PRM clientSoftwarefordocument:AdobeReader10.1,11.0,andDCField communication serverDriver: WhenPRMisconnectedwithCENTUMVP/CS3000and/orProSafe-RS,acontrolnetworkdriver (Vnet/IPorVnet)isrequired.(*1) ForconnectingwithsimplifiedsystemforFF-H1deviceadjustment,FF-H1fieldbusinterfacecarddriver
l Software requirements for connected systemCENTUM VPCENTUMVP:R4.01orlater R4.01orlatertosupportHARTcommunication R4.02.30orlatertosupportISA100fieldwirelesscommunication R4.03.00orlatertosupportFastdevicepatrolforHARTForconnectingwithCENTUMVP,ExaopcOPCinterfacepackage(forHIS)R4.01orlaterorExaopcOPCInterfacePackage(NTPF100)R3.50orlaterisrequired.
CENTUM CS 3000CS 3000: R3.01 or later R3.02orlatertosupportHARTdevices R3.07orlatertonotifyHISofoperatorguidemessage R3.08orlaterforassociationwithConsolidatedalarmmanagementsoftwareforHIS(CAMSforHIS)ForconnectingwithCENTUMCS3000,ExaopcOPCinterfacepackage(forHIS)R3.01orlaterorExaopcOPCinterfacepackage(NTPF100)R3.01orlaterisrequired.AsforHARTdevicesupport,ExaopcOPCinterfacepackage(forHIS)R3.02orlaterisrequired.
ProSafe-RSProSafe-RS: R1.02 or later R2.20orlatertosupportupstreamprojects R3.02.10orlatertosupportVnet/IPnarrowbandsystem R4.01.00orlatertosupportdevicestatusnotificationforHARTdevicesthatareconnectedtoN-IO.ForconnectingwithProSafe-RS,ExaopcOPCinterfacepackage(forHIS)needstobeR3.06orlater;andR3.07orlatertonotifyHISofoperatorguidemessage.Or,useExaopcOPCinterfacepackage(NTPF100)R3.01orlater.
Option Code /FF-H1 For Foundationfieldbusdevices(*1)
Note: This package runs on a computer where a PRM client (SSS7710) is installed.Note: OnlyFoundationfieldbusdevicesaresupported.Note: ThispackageisfortousewithYVP110advancedvalvepositioner.*1: ToconnectwithFoundationfieldbusdevices,ensuretospecifytheoptioncodeof“/FF-H1.”
Software media for PLUG-IN ValveNavi
Description Model SSSAM02 PLUG-INapplicationmediaforPlantResourceManager
Note: ElectronicinstructionmanualforPLUG-INValveNaviisincludedinthissoftwaremedia.FCN/FCJ OPC server for WindowsFor more information, refer to GS 34P02Q61-01E.
SOFTWARE LICENSE VERSION UPGRADE FROM R2 TO R3ThissectionisdedicatedforthePRMR2userswhowishtoupgradetoR3forthebenefitofusingnewfunctionsthatareonlyavailablefromR3.PurchaseeveryupgradingR3licensethatmatchwiththeexistingR2(basicandmultiplelicenses).SpecifythesamenumberofconnecteddevicesasR2.
PRM server for upgrading from R2 to R3
Description Model SSS7700RU PlantResourceManager(server)upgrade[Mediamodel:SSSSM02-C11]