WORLD LEADING BRAND OF INDOOR THERMAL COMFORT FRENCH BRAND SINCE 1968 GENERAL CATALOGUE 2016 -17 HEAT PUMPS ELECTRIC ROOM HEATING DOMESTIC HOT WATER BATHROOM HEATING VENTILATION thermal comfort more energy losses less
23

GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

Mar 21, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

WORLD LEADING BRAND OF INDOOR THERMAL COMFORT

F R E N C HB R A N DSINCE 1968

GENERALCATALOGUE

2016 -17

HEAT PUMPS

ELECTRIC ROOM HEATING

DOMESTIC HOT WATER

BATHROOM HEATING

VENTILATION

thermalcomfort

moreenergylosses

less

thermalcomfort

moreenergylosses

less

Page 2: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

www.groupe-atlantic.com

12 strategic and leading brands

5900 employees, including 2500 outside of France

20 industrial sites: 10 in France and 10 in several other countries

€1.35 bn in turnover, 37% of which is generated outside France

4% of turnover allocated to R&D

Water heating, air heating, air conditioning and ventilation, GROUPE ATLANTIC develops high-performance solutions

that are both competitive and environmentally friendly. Distributed in over

70 countries, they are designed for individual homes, collective housing,

offices, shops, schools, airports, hospitals and all other commercial buildings.

A B R A N D O F G R O U P E AT L A N T I C

Page 3: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

T U R K E Y

S W I T Z E R L .

S P A I N

PO

RT

UG

AL

I TA

LY

U K R A I N E

R U S S I A

A U S T R I A

BE L G I U M

GE

RM

AN

Y

U N I T E D K I N G D O MP O L A N D

MERVILL

E BILLY-B

ERCLA

U

CAUROIR

AULNAY-S

OUS-BOIS

ORLÉANS

LA ROCHE S

UR YON

MEYZIE

U

PONT DE V

AUX

POOLE

SAINT-L

OUIS

FONTA

INE

ODESSAKNITT

ELFE

LD

YOZGAT

IZMIR

RAYONG

CAIRO

E G Y P T

BLACKPOOL

HULL

Atlantic is a multi-energy brand manufacturing heating, water heating and ventilation solutions for residential and commercial markets across the globe. It aims at constantly strengthening its customers’ satisfaction by increasing and improving its product portfolio, as well as getting closer to its customers.

To this end, Atlantic succeeded at improving and completing its water heating solutions to comply with the new European environment standards, and offers a coherent range of water heaters from 10 L to 3000 L. It also keeps focusing its R&D investments on developing new eco-friendly solutions for heating and water heating.

With this new broaden and improved offer, customers benefi t from Atlantic's latest technology and energy-savings.

Latest key facts:2014 Factory creation in Thailand for electric water heaters manufacturing2015 Factory creation in France for heat pumps and boilers manufacturing Acquisition of a UK market leader for wall mounted condensing gas boiler and commercial gas boiler2016 Representative offi ce opening in Dubai

COMMERCIAL CALORIFIERS

ELECTRICHEATING

DOMESTICHOT WATER

DOMESTIC & COMMERCIAL GAS

CONDENSING BOILERS

VENTILATIONBATHROOM HEATING

HEAT PUMPS

Atlantic products portfolio: the broadest choice for the customer's benefi t

To learn more about Atlantic, visit our website www.atlantic-comfort.com

ATLANTIC - WORLDWIDE EXPERT OF THERMAL COMFORT SOLUTIONS

Atlantic factories around the world

3

•10 industrial sites in France• 10 industrial sites abroad

preserving French know-how

Page 4: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

54

ATLANTIC GUIDES YOU

What is ErP? The acronym ErP stands for Energy related Products. It is linked to the Ecodesign directive of the European Union concerning this type of equipment. The Ecodesign defines minimum efficiency requirements for energy-related products such as water heaters, heat pumps, boilers and solar water heaters. All manufacturers must comply with this new directive since September, 2015.

Ecodesign Directive

Ecodesign defines the acceptable energy efficiency levels, as well as environmental requirements for energy-related products. Therefore, heating and water heating products must comply with all Ecodesign requirements in order to get the CE mark and be sold within the European Union market.Ecodesing also aims at excluding all low performance energy-using equipment from the market.The ErP Ecodesign will apply to the following products:• Renewable energy water heaters (solar, heat pump)• Electric water heaters• Heat pumps with a rated heat output ≤ 400 kW

Energy Labeling Directive

Well known to the end-user of white goods, energy efficiency label became mandatory for all heating and water heating products, within the EU market, since September 26th, 2015.These products must have energy efficiency labels which inform end-users about their performance. It creates much more transparency for customers and helps them make the right choice, for their purchase, by taking into consideration their real performance level (energy consumption, noise level and other product-specific information).

TWO REQUIREMENTS FOR ENERGY-RELATED PRODUCTS

*According to the European Commission website

2

1 WHY IS IT IMPORTANT?

Energy savings and environmental protection will be the main challenges for the European Union for years to come. In this matter, as some heating and water heating products can be very energy-consuming, the goal of the new European directive, also called the 20-20-20 target, is to: • Decrease CO2 emissions by 20%.• Reduce the use of primary energy by 20%.• Increase renewable energy share by 20% by 2020.

Ultimately, as regards heating and water heating products, the result of these new standards will be an annual energy saving in Europe of around 56 Mtoe (Million tonnes of oil equivalent) by 2020. It represents roughly 20% of France total annual primary energy consumption*.

Page 5: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

54

THROUGH ERP REGULATION

You can find all necessary information about different ErP labels on the ErP section of our website

HOW TO READ A PRODUCT LABEL? EXAMPLE WITH ATLANTIC’S ONDEO*

Depending on product’s functions, the label shows two different classifications: one for heating and one for water heating.

Supplier’s name or trademark

Product’s name or reference

Energy efficiency class

Annual electricity consumption

Considering all energy efficiency indicators, products are ranked

from A (highest) to G (lowest)

Water heater load profile

Generated sound level

*Example of ErP label for water heaters

www.atlantic-comfort.com

The product's label is provided by the manufacturer. In European Union the end-user's contact (distributor or installer) is responsible for providing visibility and comprehension of the ErP label content.

3

Page 6: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

6

ATLANTIC PRODUCTS ARE ErP-READY!

Atlantic is an expert in heating and water heating, with effi cient and eco-friendly solutions. It owns several exclusive patented technologies. It welcomes and actively supports the new ErP regulation. Therefore, all Atlantic water heaters, heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ !

Moreover, Atlantic is already preparing for the future ErP requirements on electric heating with the same dedication it showed for the previous ErP requirements on heat pumps and water heating solutions.

Water heater Ondeo 10 L

Heat pump water heater Explorer

Water heater Vertigo 65 L

Heat pump Alfea Extensa+ 35°C

Atlantic not only makes ErP compliant products, but also wants to make sure that its end-users and partners have a complete understanding of the Ecodesign directive challenging goals, the role they can play in its implementation and the positive consequences it will bring for them.

Benefits for the end-users:• Increased long-term energy efficiency allowing energy and money savings• Contribution to environmental protection due to reduced greenhouse gas emissions• Easier product choice due to energy information transparency• Inefficient and polluting products disappearance from the market

Partner’s benefits:• Professional expertise reinforced with high-quality and efficient environment-friendly products• Fruitful partnership with an innovative company constantly improving its products energy efficiency• Association with a renowned French brand, with a solid worldwide presence, continuously expanding• Full support and guidance in customer relation management regarding low energy products

A A B A++See p.66 See p.18 See p.48 See p.154

EXAMPLES OF ATLANTIC’S TOP PRODUCTS FOR ENERGY EFFICIENCY2

1 WHAT ARE THE BENEFITS?

Page 7: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

7

• ErP-dedicated section • Products technical sheets

Space & energy saving water heater with premium flat design

Vertigo

F R E N C HB R A N DSINCE 1968

COMFORT• Space-saving solution suitable for small apartments• Premium flat design (less than 30cm depth)• Multiposition installation: can be both installed

vertically and horizontally to fit in the living rooms, bathrooms and kitchens

• Boost function: 1 shower in less than 30 minutes

SAVINGS• Smart control: Smart system for energy savings,

learning consumer habits• Accurate electronic thermostat and finest temperature

control to guarantee safe operating and energy savings

• High-efficiency water inlet• CFC-free high-density insulation for increased

energy savings

QUALITY - DURABILITY• Extra life-time of the heating element thanks

to Double tank Steatite technology: double ceramic dry heating element, adapted to highly mineralized, hard or desalinated water

• Magnesium anode for increased protection of the tank

• New generation diamond-quality enameling• Pressure relief valve• Dielectric union• Specific lip gasket to avoid rust around flange• IP 24 - Full compliance with European standards

for electrical safety and user protection

USER-FRIENDLINESS• Intuitive user-friendly interface with quick modes

selection knob• Easy installation with wall mounting plates

and drilling template

Product

EASY TO INSTALL

Model available** Capacity Energy savingsSmart control function

Digital interface Heating element

* Depending on models - ** Model types : A : Vertical wall mounted / B : Horizontal wall mounted / C : Vertical Floor standing / D : Multiposition installation

A B C

ELECTRIC WATER HEATER

25 TO 80L (VERTICAL AND HORIZONTAL

WALL MOUNTED)

ErPBestB*

Tank protection

MAGNESIUM ANODE

D

15-9032 FT Vertigo_V5.indd 1 13/05/2016 12:29

Atlantic is your ErP advisorYou will fi nd the energy classifi cation of all our products concerned by the ErP regulation on each product page of this catalogue.

You can also fi nd detailed information about Atlantic products classifi cation and ErP regulations on our website www. atlantic-comfort.com

19

ErPReadyA

HEAT PUMP WATER HEATERFLOOR STANDING 200 TO 270L

INSTALLATION DIMENSIONS (in mm)

SPECIFICATIONSCAPACITY (L)

200 270Dimensions (mm) 1 609 x 620 x 665 1949 x 620 x 665

Net weight without coil (kg) 85 93

Net weight with coil (kg) 100 108

Tank capacity (L) 200 270

Electric backup volume (L) 110 130

Rated water pressure (bars) 8

Electrical connection (V/Hz) 230 V~/50 Hz

Maximal total power consumed by the device (W) 2 465

Maximum power consumed by the heat pump (W) 665

Power consumed by electric heating (W) 1 800

Water temperature range by heat pump (°C) 50 to 62°C

Heat pump temperature range of use (°C) 5 to 43°C

Refrigerant fluid R 134A (kg) 1.25 1.35

Vacuum air flow (ambient installation) (m3/h) 390

COP at 20°C* (ambient) 4.1 4.3

COP at 7°C* (ambient) 2.79 (L profil) 2.84 (XL profil)

Acoustic pressure at 2m (dB(A)) 37

Acoustic power (dB(A)) 57

Heating time from 15 to 51°C (ambient installation 15°C air) (H) 4h48 7h32

Coil power (kW) primary 60°C, 1000 / 1500 / 2000 L/H (kW) 15.5 / 16 / 16.4

Coil surface (m2) 1.2

Recirculation connection Available for models with coil

ERP Energy class A A

TECHNICAL CHARACTERISTICS

*In the conditions of EN 255-3 - **In the conditions of EN 16147

1 MENU button with access to general information, working

temperature range settings, choice of boiler or solar system support, and mode selection

2 Control knob for temperature adjustments3 Temperature validation button4 Return to previous screen view5 High visibility display showing active mode and energy

consumption statistics information in curves

12

3

4

5

For more information, see p.16-17

1

27

8

3

4

5

6

AJUSTABLE AIR INLET / OUTLET

Suitable for all installations (low ceiling, corner…)

1 Evaporator

2 High efficiency heat pump: COP = 3.8**

3 Wireless remote control

4 Diamond-quality enamel

5 Enamelled sleeve and Steatite heating element

6 Coil 30 kW (1.2 m2): • Solar mode • Boiler mode

7 Adjustable air inlet /outlet (360°)

8 ACI Hybrid anti-corrosion protection

Adjustable feet

2SteatiteT E C H N O L O G Y

=

1 Magnesium anode: ultimate

protection against corrosion2 High-density

polyurethanefoam 0 % CFC3 Diamond-quality enamel4 Enamelled sleeve5 Optimised stainless

steeloutlet pipe6 Inlet diffuser7 Steatite dry heating element8 Temperature knob9 Dual power knob

(only for Steatite square)

ELECTRIC WATER HEATER75 TO 150 L VERTICAL WALL MOUNTED30 TO 50 L SLIM VERTICAL WALL MOUNTED

STEATITE SQUARE Vertical wall mounted

STEATITE SQUARE SLIM Vertical wall mountedHLMIP 25

IP 24

Control panel

1 Dual-power selection (only for Steatite model)

2 Pilot light3 Temperature control

1 Dual-power selection (only for Steatite model)

1 2 3

ErPBestB*

INSTALLATION DIMENSIONS (in mm)

A

I

G

B

E

C

D

B

F

J

A

I

G

B

E

C

D

B

F

J

A C

DJ

I

G

B

B

F

E

A C

D

G

B

B

F

E

Steatite square Steatite square slim

* Depending on models

SLIM VERTICAL WALL MOUNTED

For more information, see p.14

TECHNICAL DATACAPACITY

(L)OUTPUT

(W)VOLTAGE

(V)HEAT-UP TIME AT 60°C

(Δt=20°C)HEAT-UP TIME AT 60°C

(Δt=50°C)ENERGY CONSUMPTION

(KWh/24h AT 65°C)

752 000 230 (220/240) 1h23 3h27 0.912 000 230 (220/240) 0h42 1h44 0.91

1002 000 230 (220/240) 2h02 5h06 1.072 000 230 (220/240) 1h02 2h34 1.07

1502 000 230 (220/240) 3h08 7h50 1.572 000 230 (220/240) 1h30 3h44 1.57

TECHNICAL DATACAPACITY

(L)OUTPUT

(W)VOLTAGE

(V)HEAT-UP TIME AT 60°C

(Δt=20°C)HEAT-UP TIME AT 60°C

(Δt=50°C)ENERGY CONSUMPTION

(KWh/24h AT 65°C)30 1 500 230 (220/240) 0h30 1h18 0.5650 2 100 230 (220/240) 0h37 1h32 0.76

DIMENSIONS

CAPACITY(L)

DIMENSIONS (mm) FLANGE OPENING (Ø) mm

NET WEIGHT (kg)

ERP ENERGYCLASSA B C D E F G I

75 706 490 510 175 230 350/440 3/4” 350 72 15 B100 875 490 510 175 230 350/440 3/4” 500 72 21 B150 1 198 490 510 175 230 350/440 3/4” 800 72 24 C

DIMENSIONS

CAPACITY(L)

DIMENSIONS (mm) FLANGE OPENING (Ø) mm

NET WEIGHT (kg)

ERP ENERGYCLASSA B C D E F G

30 624 432 347 100 100 184 1/2” 72 15 B50 950 432 347 100 100 184 1/2” 72 21 B

VERTICAL WALL MOUNTED

B*

Steatite square Slim

1 2

3

4

5

6

79

8

Steatite square Steatite square Slim

1 2

3

4

5

6

7

89

6

SteatiteT E C H N O L O G Y

55

=

1 Magnesium anode: ultimate

protection against corrosion2 High-density

polyurethanefoam 0 % CFC3 Diamond-quality enamel4 Enamelled sleeve5 Optimised stainless

steeloutlet pipe6 Inlet diffuser7 Steatite dry heating element8 Temperature knob9 Dual power knob

(only for Steatite square)

ELECTRIC WATER HEATER75 TO 150 L VERTICAL WALL MOUNTED30 TO 50 L SLIM VERTICAL WALL MOUNTED

STEATITE SQUARE Vertical wall mounted

STEATITE SQUARE SLIM Vertical wall mountedHLMIP 25

IP 24

Control panel

1 Dual-power selection (only for Steatite model)

2 Pilot light3 Temperature control

1 2 3

ErPBestB*

INSTALLATION DIMENSIONS (in mm)

A

I

G

B

E

C

D

B

F

J

A

I

G

B

E

C

D

B

F

J

A C

DJ

I

G

B

B

F

E

A C

D

G

B

B

F

E

Steatite square Steatite square slim

* Depending on models

SLIM VERTICAL WALL MOUNTED

For more information, see p.14

TECHNICAL DATACAPACITY

(L)OUTPUT

(W)VOLTAGE

(V)HEAT-UP TIME AT 60°C

(Δt=20°C)HEAT-UP TIME AT 60°C

(Δt=50°C)ENERGY CONSUMPTION

(KWh/24h AT 65°C)

752 000 230 (220/240) 1h23 3h27 0.912 000 230 (220/240) 0h42 1h44 0.91

1002 000 230 (220/240) 2h02 5h06 1.072 000 230 (220/240) 1h02 2h34 1.07

1502 000 230 (220/240) 3h08 7h50 1.572 000 230 (220/240) 1h30 3h44 1.57

TECHNICAL DATACAPACITY

(L)OUTPUT

(W)VOLTAGE

(V)HEAT-UP TIME AT 60°C

(Δt=20°C)HEAT-UP TIME AT 60°C

(Δt=50°C)ENERGY CONSUMPTION

(KWh/24h AT 65°C)30 1 500 230 (220/240) 0h30 1h18 0.5650 2 100 230 (220/240) 0h37 1h32 0.76

DIMENSIONS

CAPACITY(L)

DIMENSIONS (mm) FLANGE OPENING (Ø) mm

NET WEIGHT (kg)

ERP ENERGYCLASSA B C D E F G I

75 706 490 510 175 230 350/440 3/4” 350 72 15 B100 875 490 510 175 230 350/440 3/4” 500 72 21 B150 1 198 490 510 175 230 350/440 3/4” 800 72 24 C

DIMENSIONS

CAPACITY(L)

DIMENSIONS (mm) FLANGE OPENING (Ø) mm

NET WEIGHT (kg)

ERP ENERGYCLASSA B C D E F G

30 624 432 347 100 100 184 1/2” 72 15 B50 950 432 347 100 100 184 1/2” 72 21 B

VERTICAL WALL MOUNTED

Steatite square Slim

1 2

3

4

5

6

79

8

Steatite square

1 2

3

4

5

6

7

89

6

SteatiteT E C H N O L O G Y

55

=

1 Magnesium anode: ultimate

protection against corrosion2 High-density

polyurethanefoam 0 % CFC3 Diamond-quality enamel4 Enamelled sleeve5 Optimised stainless

steeloutlet pipe6 Inlet diffuser7 Steatite dry heating element8 Temperature knob9 Dual power knob

(only for Steatite square)

ELECTRIC WATER HEATER75 TO 150 L VERTICAL WALL MOUNTED30 TO 50 L SLIM VERTICAL WALL MOUNTED

STEATITE SQUARE Vertical wall mounted

STEATITE SQUARE SLIM Vertical wall mountedHLMIP 25

IP 24

Control panel

1 Dual-power selection (only for Steatite model)

2 Pilot light3 Temperature control

1 2 3

ErPBestB*

INSTALLATION DIMENSIONS (in mm)

A

I

G

B

E

C

D

B

F

J

A

I

G

B

E

C

D

B

F

J

A C

DJ

I

G

B

B

F

E

A C

D

G

B

B

F

E

Steatite square Steatite square slim

* Depending on models

SLIM VERTICAL WALL MOUNTED

For more information, see p.14

TECHNICAL DATACAPACITY

(L)OUTPUT

(W)VOLTAGE

(V)HEAT-UP TIME AT 60°C

(Δt=20°C)HEAT-UP TIME AT 60°C

(Δt=50°C)ENERGY CONSUMPTION

(KWh/24h AT 65°C)

752 000 230 (220/240) 1h23 3h27 0.912 000 230 (220/240) 0h42 1h44 0.91

1002 000 230 (220/240) 2h02 5h06 1.072 000 230 (220/240) 1h02 2h34 1.07

1502 000 230 (220/240) 3h08 7h50 1.572 000 230 (220/240) 1h30 3h44 1.57

TECHNICAL DATACAPACITY

(L)OUTPUT

(W)VOLTAGE

(V)HEAT-UP TIME AT 60°C

(Δt=20°C)HEAT-UP TIME AT 60°C

(Δt=50°C)ENERGY CONSUMPTION

(KWh/24h AT 65°C)30 1 500 230 (220/240) 0h30 1h18 0.5650 2 100 230 (220/240) 0h37 1h32 0.76

DIMENSIONS

CAPACITY(L)

DIMENSIONS (mm) FLANGE OPENING (Ø) mm

NET WEIGHT (kg)

ERP ENERGYCLASSA B C D E F G I

75 706 490 510 175 230 350/440 3/4” 350 72 15 B100 875 490 510 175 230 350/440 3/4” 500 72 21 B150 1 198 490 510 175 230 350/440 3/4” 800 72 24 C

DIMENSIONS

CAPACITY(L)

DIMENSIONS (mm) FLANGE OPENING (Ø) mm

NET WEIGHT (kg)

ERP ENERGYCLASSA B C D E F G

30 624 432 347 100 100 184 1/2” 72 15 B50 950 432 347 100 100 184 1/2” 72 21 B

VERTICAL WALL MOUNTED

Steatite square Slim

1 2

3

4

5

6

79

8

Steatite square

1 2

3

4

5

6

7

89

6

SteatiteT E C H N O L O G Y

55

ErPReadyA

HEAT PUMP WATER HEATERFLOOR STANDING 200 TO 270L

INSTALLATION DIMENSIONS (in mm)

SPECIFICATIONSCAPACITY (L)

200 270Dimensions (mm) 1 609 x 620 x 665 1949 x 620 x 665

Net weight without coil (kg) 85 93

Net weight with coil (kg) 100 108

Tank capacity (L) 200 270

Electric backup volume (L) 110 130

Rated water pressure (bars) 8

Electrical connection (V/Hz) 230 V~/50 Hz

Maximal total power consumed by the device (W) 2 465

Maximum power consumed by the heat pump (W) 665

Power consumed by electric heating (W) 1 800

Water temperature range by heat pump (°C) 50 to 62°C

Heat pump temperature range of use (°C) 5 to 43°C

Refrigerant fluid R 134A (kg) 1.25 1.35

Vacuum air flow (ambient installation) (m3/h) 390

COP at 20°C* (ambient) 4.1 4.3

COP at 7°C* (ambient) 2.79 (L profil) 2.84 (XL profil)

Acoustic pressure at 2m (dB(A)) 37

Acoustic power (dB(A)) 57

Heating time from 15 to 51°C (ambient installation 15°C air) (H) 4h48 7h32

Coil power (kW) primary 60°C, 1000 / 1500 / 2000 L/H (kW) 15.5 / 16 / 16.4

Coil surface (m2) 1.2

Recirculation connection Available for models with coil

ERP Energy class A A

TECHNICAL CHARACTERISTICS

1 MENU button with access to general information, working temperature range settings, choice of boiler or solar system support, and mode selection

2 Control knob for temperature adjustments3 Temperature validation button4 Return to previous screen view5 High visibility display showing active mode and energy

consumption statistics information in curves

MENU button with access to general information,

12

3

4

5

For more information, see p.14-15 see p.20

1

27

8

3

4

5

6

AJUSTABLE AIR INLET / OUTLET

Suitable for all installations (low ceiling, corner…)

1 Evaporator

2 High efficiency heat pump: COP = 3.8**

3 Wireless remote control

4 Diamond-quality enamel

5 Enamelled sleeve and Steatite heating element

6 Coil 30 kW (1.2 m2): • Solar mode • Boiler mode

7 Adjustable air inlet /outlet (360°)

8 ACI Hybrid anti-corrosion protection

Adjustable feet

2SteatiteT E C H N O L O G Y

19

*In the conditions of EN 255-3 **In the conditions of EN 16147

ErPReadyA

HEAT PUMP WATER HEATERFLOOR STANDING 200 TO 270L

INSTALLATION DIMENSIONS (in mm)

SPECIFICATIONSCAPACITY (L)

200 270Dimensions (mm) 1 609 x 620 x 665 1949 x 620 x 665

Net weight without coil (kg) 85 93

Net weight with coil (kg) 100 108

Tank capacity (L) 200 270

Electric backup volume (L) 110 130

Rated water pressure (bars) 8

Electrical connection (V/Hz) 230 V~/50 Hz

Maximal total power consumed by the device (W) 2 465

Maximum power consumed by the heat pump (W) 665

Power consumed by electric heating (W) 1 800

Water temperature range by heat pump (°C) 50 to 62°C

Heat pump temperature range of use (°C) 5 to 43°C

Refrigerant fluid R 134A (kg) 1.25 1.35

Vacuum air flow (ambient installation) (m3/h) 390

COP at 20°C* (ambient) 4.1 4.3

COP at 7°C* (ambient) 2.79 (L profil) 2.84 (XL profil)

Acoustic pressure at 2m (dB(A)) 37

Acoustic power (dB(A)) 57

Heating time from 15 to 51°C (ambient installation 15°C air) (H) 4h48 7h32

Coil power (kW) primary 60°C, 1000 / 1500 / 2000 L/H (kW) 15.5 / 16 / 16.4

Coil surface (m2) 1.2

Recirculation connection Available for models with coil

ERP Energy class A A

TECHNICAL CHARACTERISTICS

1 MENU button with access to general information, working temperature range settings, choice of boiler or solar system support, and mode selection

2 Control knob for temperature adjustments3 Temperature validation button4 Return to previous screen view5 High visibility display showing active mode and energy

consumption statistics information in curves

12

3

4

5

For more information, see p.14-15 see p.20

1

27

8

3

4

5

6

AJUSTABLE AIR INLET / OUTLET

Suitable for all installations (low ceiling, corner…)

1 Evaporator

2 High efficiency heat pump: COP = 3.8**

3 Wireless remote control

4 Diamond-quality enamel

5 Enamelled sleeve and Steatite heating element

6 Coil 30 kW (1.2 m2): • Solar mode • Boiler mode

7 Adjustable air inlet /outlet (360°)

8 ACI Hybrid anti-corrosion protection

Adjustable feet

2SteatiteT E C H N O L O G Y

19

*In the conditions of EN 255-3 **In the conditions of EN 16147

• Product pages

Page 8: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

8

Easy to install and to use

• Connect the Cozytouch bridge to your Connect the Cozytouch bridge to your Connect Internet box using an Ethernet cable

• Ensure Cozytouch bridge electric connection (USB connection possible)

• Download the Cozytouch applicationon or

• Pair two (or more) appliances with each other using the appliance’s digital control panel compatible with Cozytouch

� Devices’ real-time monitoring

� Devices’ real-time monitoring

� � Absence management

� Daily energy consumption visualization & optimization

8

DISTANCE PILOTING• Comfort and savings management from a tablet

or a smartphone, the user being at home or outside• Appliances real-time monitoring (temperature setting,

electric consumption view, etc.)• Free distance piloting & free programming for each day

(30 min by 30 min)• Two ways communication with the connected appliances:

both sending and receiving signals; receiving a real-time command reception confi rmation, with a luminous signal or a feedback text on the user’s device

SYNCHRONIZATION• Optimisation of each room piloting• Devices communicate together via IO-Homecontrol® protocol• Temperatures synchronisation, operating modes and

presence/absence detection among all compatible appliances installed

• Appliances not equipped with a presence sensor can communicate with and benefi t from the data of other appliances equipped with a presence sensor

USER-FRIENDLINESS• Easy to install: Pairing using a button and a LED IO-Radio

Interface or directly using the control box of our native IO-Homecontrol® products

• Secure: Orders authentication through a secure key (128 bits encryption) specifi c to each unit

• Robust and compliant with CE regulation EN 300-220• Cozytouch can be installed up to 20m away from the

appliances it controls, in a 3-fl oor housing (868-870MHz)

Product

• Home automation: controlling heating, from afar through a smartphone ora tablet*

• Providing comfort, security and energy savings every day by making the automated or motor-operated equipment of the user’s home more effi cient

• Devices communicate together usingIO-Homecontrol® protocol

*Android and Apple compatible, incompatible with Windows store

ATLANTIC CONNECTS TO YOUR HOME THROUGH COZYTOUCH

Connecting the user’s home to intelligent & remote piloting

Page 9: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

9

When using Home automation, with Cozytouch and the IO-Homecontrol® technology, the user has full control of his daily level of comfort

and/or his energy savings requirements.

Innovative technology to simply connect your homeIO-Homecontrol® provides comfort, security and energy savings every day by making the automated or motor-operated equipment of your home more efficient: roof windows, roller shutters, interior and exterior solar screens, gates, garage doors, entrance doors, alarms, lighting, heating and cooling systems, etc.

Greater energy savings

The combination of IO-Homecontrol® compatible products (opening/closing, heating/ventilation) significantly improves the energy efficiency of your home.

Greater comfort

IO-Homecontrol® home automation helps you manage your daily well-being, programming your equipments according to your needs.. It lets you avoid troublesome and repetitive tasks (switching off all the lights, lowering the blinds and shutters, locking the gate, etc.) by doing them all for you!

Greater security

IO-Homecontrol® combines dynamic protection (door, shutter and window closing/locking sequences) and static alert resources, all coordinated and automatically controlled on-site or remotely.

IO-Homecontrol

Irisium(see page 86)

Maradja smart pilot IO(see page 88)

Tatou smart pilot IO(see page 132)

ELECTRIC PANEL HEATERS

BATHROOM HEATING

Sensium(see page 122)

Explorer(see page 18)

Explorer

HEAT PUMP WATER HEATER

VENTILATION SYSTEM

Optimocosy HR(see page 146)

IO-Homecontrol®

For more information, see p.22

Page 10: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

Contents

p. 6 DOMESTIC HOT WATER p. 76 ELECTRIC ROOM

HEATING

1 DOMESTIC HOT WATER: 2 Renewable energies water heaters . . . . . . . . . . . 17

3 Indirect & combi water heaters . . . . . . . . . . . . . . . 34

4 Electric water heaters: . . . . . . . . . . . . . . . . . . . . . . . .425 Central domestic water heaters . . . . . . . . . . .446 Medium capacity water heaters . . . . . . . . . .527 Point of use water heaters . . . . . . . . . . . . . . . .70

8 ELECTRIC ROOM HEATING: 9 Gentle heat radiators . . . . . . . . . . . . . . . . . . . . . . . 84

10 Extensive heat panels . . . . . . . . . . . . . . . . . . . . . . . 94

11 Active heat convectors . . . . . . . . . . . . . . . . . . . . 102

Page 11: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

8 ELECTRIC ROOM HEATING: 9 Gentle heat radiators . . . . . . . . . . . . . . . . . . . . . . . 84

10 Extensive heat panels . . . . . . . . . . . . . . . . . . . . . . . 94

11 Active heat convectors . . . . . . . . . . . . . . . . . . . . 102

HEAT PUMP

12 BATHROOM HEATING:13 Bathroom radiators

and towel dryers . . . . . . . . . . . . . . . .120

14 Extensive heat bath & kitchen

panel heaters & Fan heaters. . . .134

15 VENTILATION: 16 Dual fl ow ventilation . . . . . . .146

17 Heat pump water heater

fed on indoor dumped air . .150

18 HEAT PUMP: 19 Heating and water heating

solutions . . . . . . . . . . . . .154

p.142p.114 VENTILATIONBATHROOMHEATING

p.152

Page 12: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

TITRE

12

Page 13: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

1

13

DUOTHERMp. 42-43

INDIRECT & COMBISTEATITEp. 38-39

INDIRECT & COMBI

O'PROp. 40-41

VIZENGOp. 46-47

STEATITECENTRAL DOMESTIC

WATER HEATERp. 48-49

O'PRO SMALL & O'PRO SLIM

p. 74-75

ONDEOp. 72-73

O'PROCENTRAL DOMESTIC

WATER HEATERp. 50-51

STEATITE SQUARE & SLIM

p. 56-57

STEATITETURBO

p. 58-59

STEATITEp. 62-63

ATLANTICEGO

p. 70-71

EXPERTp. 66-67

O'PRO+p. 68-69

O'PROTURBO

p. 64-65

INGENIOp. 54-55

STEATITESLIM

p. 60-61

SOLERIOOPTIMUM 2

p. 26-27

SOLARCOLLECTORS

p. 32-33

SOLERIO SELECT p. 28-29

EXPLORERp. 20-21

EGEOp. 24-25

VERTIGOP. 52-53

DOMESTIC HOT WATER

1

RENEWABLE ENERGIES WATER HEATERS2

ELECTRIC WATER HEATERS4

INDIRECT & COMBIWATER HEATERS

3

CENTRAL DOMESTIC WATER HEATERS

5 POINT OF USEWATER HEATERS

7MEDIUM CAPACITY WATER HEATERS6

13

Page 14: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

DOMESTIC HOT WATER APPLIANCE RIGHT CHOICE

WATER QUALITY IMPORTANCEWater is a chemical agent charged with positive and negative ions. When the number of ions is balanced, the water charge is neutral. However, depending on region, supplied water isn't always balanced. Aggressive, highly mineralised and hard water can reduce the performance and lifetime of the water heater. Atlantic offers the largest choice of appliances enabling the client to make the right choice.

To each type of water Atlantic recommends an optimal choice of protection:

HOT WATER NEEDS' ESTIMATION

Magnesium anode

O’ProTechnology

Steatitetechnology

SteatiteT E C H N O L O G Y

++ +++ ++++

++++ ++++ ++++

++ +++ ++++

Aggressive water generating corrosion

Balanced water creating a natural protection for the appliance

Hard water generating high levels of scale

The required water heater capacity takes into account the number of drain points and number of people in household.

Water heater capacity: 10-30 LNum. of simultaneous users:

Water heater capacity: 50 LNum. of simultaneous users:

Water heater capacity: 80-120 LNum. of simultaneous users:

Water heater capacity: 150-500 LNum. of simultaneous users:

14

Page 15: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

1

15

RECOMMENDED COMFORT CRITERIA

EfficiencyContinuous access to hot water at the required temperature thanks to fast heating functions and accurate regulation

Energy savingsEnergy savings achieved through Smart functions, optimized water heating control and efficient insulation

DurabilityHigh quality of the water heater and its components; long-lasting protection of the tank to prevent scale deposits and rust thanks to quality enamelling

User-friendlinessAppliances easy to install, use and maintain

DOMESTIC HOT WATER PRODUCTION

LESS CO2 WITH ATLANTIC SOLUTIONS... ...AND MORE ENERGY SAVINGSAtlantic develops environmentally friendy solutions for DHW (Domestic Hot Water). These solutions divide CO² emission rate by up to 15 compared to fossil energies.

CO² yearly emissions over a year for DHW use per household (4 people).

Up to 70% energy savings, while ensuring optimal comfort.

CO² yearly emissions during one year for DHW use per household (4 people).

IP INDEX: PROTECTION AGAINST WATER PROJECTIONS

The water heater’s protection level against water projections is defined by its IP index which defines the safe installation areas for electric appliances when close to water draining points. Atlantic water heaters have a high IP index up to IP 25 and can be installed in areas 1, 2 and/or 3 of the bathroom depending on country regulation. Atlantic products IP index guarantees safe operation.

Source: RT 2005 calculations

NOWADAYS, ELECTRICITY IS INCREASINGLY ROOTED IN NATURE,

THIS IS WHAT MAKES ITS STRENGTH

3 421

100

200

300

3518

231

296

Solar water heater with electric

back-up kit

Heat-pump water heater

Gas boiler coupled with solar installation

Fuel boiler coupled with solar installation

Electricity Gas FuelOil

100

200

300

3518

231

296

Solar water heater with electric

back-up kit

Heat-pump water heater

Gas boiler coupled with solar installation

Fuel boiler coupled with solar installation

Electricity Gas Fuel

Oil

Page 16: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

1716

ATLANTIC TECHNOLOGIES

Atlantic develops exclusive patented technologies achieving long-lasting service time in the day to day use, as well as optimum effi ciency & savings.

• Electronic/ digital controls - ultimate accuracy- High precision electronic sensors driven by PCB

- Large diagnostic & function options

- Safety through independent security device

• Bulb thermostat- Accurate control by highly sensitive device

- Safety through independent security device

• Rod thermostat- Classical thermostat, simple and reliable- Safety through independent security device- Only compatible with direct heating element

2

• Ceramic dry heating element: outstanding unique patented Steatite technology, adapted to highly mineralised, desalinated or hard water

The Steatite heating element is protected by an enamelled steel sleeve. This grants a large heat exchange surface, which reduces scale deposits and heating noise. In addition to being extremely efficient, the ceramic heating element is particularly well adapted to hard, aggressive, highly mineralised and desalinated water. Its replacement does not require the water heater to be drained down for maintenance, a genuine bonus for professionals and private individuals.- Low charge per m² on the exchange surface = reduced scale formation- Large exchange surface = less noise- Heating element protected by enamelled steel sleeve- No direct contact with water- Easy maintenance: no need to drain the tank- Power from 1200 W to 3000 W

• Direct immersion heating element: an approved solution The sheathed heating element is a copper or stainless steel heating element.

It offers high-level performance thanks to its duly balanced charge, providing extended lifetime. Power from 1200 W to 2500 W

1 HEATING ELEMENTS

CONTROLS ACCURACY

SteatiteT E C H N O L O G Y

Page 17: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

1716

1

standard gasket

lip gasket

steel flange

flange

standard gasket

lip gasket

steel flange

flange

• Patented ACI Hybrid system: state-of-the-art titanium anode The Anti-Corrosion Integrated (ACI Hybrid) system provides maximum protection

to the tank. The titanium anode located at the center of the appliance is driven by an electronic PCB board that produces a milivoltage electric current providing the tank with a lifetime protection, replacing magnesium anode. A control light indicates to the user that the ACI Hybrid system is operational.

• Exclusive O’Pro technology: passive electronic anti-corrosion system (Ohmic resistor)

The ohmic resistor is a passive electronic anti-corrosion device. It balances out the electric potentials of the tank and immersion heating element. The magnesium anode life is considerably increased and protection against corrosion is reinforced.

• Classic magnesium anode The sacrificial magnesium anode is located in the center of the enamelled tank and

provides excellent protection against corrosion.

• Tank enamel & welding: the key for long-life and reliability Perfect enamelling & welding are the key to a reliable water heater. Atlantic uses metal-free welding only (aeronautical industry know-how) and exclusive Diamond-quality enamel.

• High density and environmentally friendly insulationThe polyurethane foam insulation prevents thermal bridges and helps maintain water at the set temperature for a longer period of time. Atlantic foam contains 0% CFC and its high density reduces heat losses.

• Reinforced protection against corrosion Unprotected steel parts in contact with water are the weakest parts of all water heaters, most leakages originate from there. Atlantic uses a unique lip gasket, granting no contact with steel tank edge and water.

3

4

ANTI-CORROSION PROTECTION

TANK PROTECTION

Page 18: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

NP18

TITRERENEWABLE ENERGIESWATER HEATERS

Heat pump water heater technology - The best all-weather solution everRenewable, clean and free calories contained in ambient air are an ideal energy source to heat water. It is performing even in conditions of night, hale or rain. Atlantic offers performing and cost-effective solutions to produce DHW.Clean and simple operation:The heat pump water heater consists of a heat pump which captures the energy in the air in order to produce DHW.

Solar water heater technology - A simple and robust solution

Closed circuit for solar panel=

No scaling +

Sanitary conformity

Solar collector

Accumulator

No-return

Cold water

Hot water

How does it work?� A thermosiphon solar water heater is composed

of a tank (accumulator) and a solar collector which is connected to the tank.

� The transfer between tank and collector is governed by gravity (hot water density is lower than cold water density). Instead of a pump, the pressure differential between hot and cold is used as propulsion energy. This is the “thermosiphon principle”. In order to operate, the collector (heat generator) must be located below the tank (heat consumer).

� The heat transfer medium is heated inside the solar collector. The hot liquid in the collector below is lighter than the cold liquid in the tank above the collector. As soon as the lighter hot liquid rises, gravity circulation starts.

� Inside the cylinder, the heated medium transfers its heat to the stored DHW and then, once cooled, falls back to the lowest point in the collector circuit.

Offering similar level of heating comfort as an electric water heater, solar water heaters are an environmentally friendy and simple solution to heat water.

How does it work?The heat pump water heater uses the operational principle of a heat pump, by absorbing calories in outdoor air and using this energy to ensure water heating.

The fan � inhales ambient air transferring its energy to the refrigerant agent in the evaporator � thus changing from liquid to gas. The gas is further heated by compression �. In the condenser � the gas transfers its accumulated heat to the water tank. As it gets colder it transforms back to fl uid. The pressure of the fl uid is further reduced by the expansion valve �. The electric back-up heating � starts only when required during insuffi cient heat pump working conditions.

18

��

Evaporator

Expansion valveFan

Cooled airAmbient air

Compressor

Electric back-up heating

Steatite dry heating element ACI hybrid

anti-corrosionprotection

Condenser

Page 19: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

22

SELECT THE APPLIANCES MATCHING YOUR NEEDSCHOICE

GUIDE

Explorer Egeo Solerio Optimum 2 Solerio Select

Heat pump water heater Forced system solar solutionThermosiphonsolar system

All weather plug-and-play heat pump water heater with or without connection

to solar panel

Performing and cost effective Class A heat pump water heater

Indoor solar tank with outdoor solar panel /and third energy source

All-in-one outdoor installation solar

solution

CAPACITY (L) 200 / 270 200 / 270 200 / 270 200 / 300 / 400 200 / 300 / 400 150 / 200 / 300

Models Floor standing Floor standing with coil Floor standing Floor standing

1 CoilFloor standing

2 CoilsHorizontal roof or terrace installation

Electric back-up output (W) 1800 1800 1800 to 2400 1800 to 2400 1800 to 2400 2000

Electric back-up heating element

SteatiteT E C H N O L O G Y

Ceramic dry

heating element

SteatiteT E C H N O L O G Y

Ceramic dry

heating element

SteatiteT E C H N O L O G Y

Ceramic dry

heating element

SteatiteT E C H N O L O G Y

Ceramic dry

heating element

SteatiteT E C H N O L O G Y

Ceramic dry

heating element

Copper heating element

Tank protection ACI hybrid

ACI hybrid

ACI hybrid

Magnesium anode Magnesium anode Magnesium anode

Interface Digital control + Cosytouch

Digital control + Cosytouch Frontal knob Digital display Digital display –

ERP Energy class

PAGES P.20 P.24 P. 26 P.28

A A AA A+* A

*Depending on models.**Explorer 200L version compared with an electric water heater.***Compared to a first generation water heater.

19

NEW

16-4069 19-35 General catalogue UK ENR_V11.indd 19 18/08/2016 10:15

Page 20: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

USER-FRIENDLINESS• Easy to install with adjustable air inlet/outlet and adjustable feet• Digital control panel with built-in day-to-day programming, different

modes selection, high visibility display showing everyday energy consumption in curves

QUALITY - DURABILITY• ACI hybrid anti-corrosion technology

and Steatite heating element• New generation diamond-quality enamelling• Pressure relief valve• Dielectric union• Specifi c lip gasket to prevent corrosion around fl ange

SAVINGS• Large optimised coil for fast heating and size adapted for low

temperature devices• CFC-free high-density insulation for increased energy savings• High-effi ciency water inlet

COMFORT• Intuitive control panel• Household-friendly noise level• Electric back-up with Steatite 1800 W element• Re-circulation connection to provide comfort on all point-of-use**• Transport: Possibility to lay down on one side for easy transport

• 75% energy savings*

• Wide heat pump temperature rangeof use (–5 to +43°C)

• Anti-corrosion ACI hybrid technology

• Remote piloting with Cozytouch control

• Smart energy consumption control

• Compatible with solar (photovoltaic panel or solar collector) and boiler systems (built-in coil)

All weather plug-and-play heat pump water heater with or without connection to solar panel

Explorer

*Explorer 200L version compared with an electric water heater.**Version with coil only

20

Product

Page 21: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

2

HEAT PUMP WATER HEATERFLOOR STANDING 200 TO 270 L

INSTALLATION DIMENSIONS (in mm)

SPECIFICATIONSCAPACITY (L)

(with or without coil)200 270

Dimensions (mm) 1609 x 620 x 665 1949 x 620 x 665

Net weight without coil (kg) 85 93

Net weight with coil (kg) 100 108

Tank capacity (L) 200 270

Electric backup volume (L) 110 130

Rated water pressure (bars) 8

Electrical connection (V/Hz) 230 V~/50 Hz

Maximal total power consumed by the device (W) 2465

Maximum power consumed by the heat pump (W) 665

Power consumed by electric heating (W) 1800

Water temperature range by heat pump (°C) 50 to 62°C

Heat pump temperature range of use (°C) -5 to 43°C

Refrigerant fluid R 134A (kg) 1.25 1.35

Vacuum air flow (ambient installation) (m3/h) 390

COP at 20°C* (ambient) 4.1 4.3

COP at 7°C* (ambient) 2.79 (L profil) 2.84 (XL profil)

Acoustic pressure at 2m (dB(A)) 37

Acoustic power (dB(A)) 57

Heating time from 15 to 51°C (ambient installation 15°C air) (H) 4h48 7h32

Coil power (kW) primary 60°C, 1000 / 1500 / 2000 L / H (kW) 15.5 / 16 / 16.4

Coil surface (m2) 1.2

Recirculation connection Available for models with coil

ERP Energy class A

TECHNICAL CHARACTERISTICS

� MENU button with access to general information, working temperature range settings, choice of boiler or solar system support, and mode selection

� Control knob for temperature adjustments� Temperature validation button� Return to previous screen view� High visibility display showing active mode and energy

consumption statistics information in curves

MENU button with access to general information,

��

For more information, see p.16-17 and p.22

� Evaporator

� High effi ciency heat pump with wide temperature range

� Intuitive control panel

� Diamond-quality enamel

� Enamelled sleeve and Steatite heating element

� Coil (1.2 m2):• Solar mode• Boiler mode

� Adjustable air inlet /outlet (360°)

� ACI Hybrid anti-corrosion protection

� Adjustable feet

SteatiteT E C H N O L O G Y

21

ErPBestA

*Compliant with EN 16147 conditions.

Ajustable air inlet / outlet

Suitable for all installations (low ceiling, corner…)

Enamelled sleeve and Steatite heating element

��

Page 22: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

EXPLORER INNOVATIVE SMART FUNCTIONS & FEATURES

40 °C

62 °C

50 °C

Water temperature (°C)

Heatingwith boiler

Heating with heat pump

Warm-up time (H)

Ambient air at 5°C Ambient air at 25°C

40 °C

62 °C60 °C

Water temperature (°C)

Heating with boiler

Heating with heat pump

Warm-up time (H)

Heating cycle at 2 different air temperature conditions with preselected HEAT PUMP OPTIMIZED priority mode

Due to Smart Control, Explorer perfectly integrates into your life, learning your habits from one week to another and memorizing them, to provide you with everyday comfort anticipating your needs, along with energy savings optimization.

Smart Control

When connected to a boiler system, Explorer activates its Smart Energy function, which helps to choose the right energy source (boiler or heat pump) at the right moment, considering the air and water temperature, by calculating its energy consumption. Therefore, Smart Energy grants the most effi cient and economical performance of Explorer connected to a boiler system.

Boiler

Heat pump

Air temperature (°C)

Heat pump priority

Water temperature

(°C)Heat pump optimized

Boileroptimized

BoilerprioritySmart energy

Explorer is compatible with new Cozytouch technology, allowing distance piloting through a smartphone or a tablet. With Cozytouch, you monitor Explorer in real-time (temperature setting, electric consumption view, etc.), tailoring your everyday comfort, security and energy consumption to your standards. Therefore, with Explorer, you have full control of your daily comfort and your energy savings requirements, even if you are not at home!

Cozytouch technology

distance piloting through With Cozytouch, you monitor Explorer in real-time (temperature

setting, electric consumption view, etc.), tailoring your everyday comfort, security and energy have full control of your daily

22

Page 23: GENERAL CATALOGUE - Bin Moosa & Daly · heat pumps and solar water heaters are ErP-ready, with products that are rated up to A+ and A++ ! Moreover, Atlantic is already preparing for

22EXPLORER INNOVATIVE SMART FUNCTIONS & FEATURES

Solar energy is collected by the photovoltaic panels and sent to the inverter to adapt to the housing global appliances installation �.Electricity is then sent to the working domestic appliances or to the power grid �.Explorer is working on power grid supply (normal electricity supply) �.

MORE ENERGY SAVINGS IN YOUR PHOTOVOLTAIC INSTALLATIONCombining 2 free energies for optimum energy savings on the water heating as well as on the restof the electric equipment

Explorer photovoltaic compatibilityBy connecting Explorer with a photovoltaic installation, you combine two green energies to achieve optimum energy savings in water heating and in the rest of the electric equipment in your home. Combined with a photovoltaic installation, Explorer gives you a free energy storage, as photovoltaic panels collect free solar energy and send it to Explorer for storage and use.Therefore, solar and heat pump energies allowyou to heat water at no cost, as well as to suply free energy to domestic appliances, no matter the weather.

Smartheat pump

SMART GRIDREADY

Thanks to photovoltaic compatibilityExplorer is open to Smart Grid technology.

• More energy savings on your global appliances installation

• Free energy storage• Low consumption water heater that offers

continuous energy savings, no matter the weather• Use solar and heat pump energy to heat

water at no cost, and to supply free energy to domestic appliances

• A dedicated connection allows automatic switch to photovoltaic energy when available

23

Solar installation usual operation