General Building Requirements – Residential Dwellings APPLICANT TO COMPLETE ☐Not Applicable To Project COUNCIL TO COMPLETE ☐Vetting (has there been information provided) Mark if applicable and compliant, Highlight if RFI required. Document ref or page # where information can be located ID Not Applicable Compliance Method Processing Inspection Code Clause Processing/inspection notes if required RFI questions and responses ☐Inspection not per consent out FM40 issued General Requirements R1500 ☐ Internal wall linings, Types, locations, fixings, and surface finishes. (ref E3/AS1, G1/AS1, G3/AS1, G7/AS1) ☐ ☐ E3 G1 G7 R1501 ☐ Internal floor linings, Types, locations, fixings, and surface finishes. (ref E3/AS1, G1/AS1, G3/AS1, G7/AS1) ☐ ☐ E3 G1 G7 R1502 ☐ Framing Moisture requirements (ref NZS3602 Table 4 or Manufactures requirements whichever is the more onerous) ☐ ☐ B2 E2 R1503 ☐ Wall insulation, thermal envelope location (ref E3/AS1 1.1 And H1, NZS4218) ☐ ☐ E3 H1
22
Embed
General Building Requirements Residential Dwellings Not ... › assets › Building › ... · General Building Requirements – Residential Dwellings APPLICANT TO COMPLETE ☐Not
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
General Building Requirements – Residential Dwellings
APPLICANT TO COMPLETE ☐Not Applicable To Project COUNCIL TO COMPLETE ☐Vetting
(has there been information provided)
Mark if applicable and compliant, Highlight if RFI required.
Document ref or page # where information can be located
R1506 ☐ Water proof Membrane/ linings, type, location and extent, installation information, supporting manufactures information (ref NZBC E3/AS1 Sec 3.3.1 meaning they are impervious to moisture? If not it is outside the scope of NZBC E3/AS1 & will need to be assessed as an alternative solution)
☐ ☐ E3
R1507 ☐ Wall junction to fixtures: Bath, basin, sink , tub, urinal, kitchens (ref E3/AS1 Para 3.0)
R1511 ☐ Asbestos products especially in adds / alts pre 1990 on PIM/PIC (ref F2/AS1 Para 2.0)
☐ ☐ F2
ADVICE NOTE:
Asbestos was a component in many building products in New Zealand between 1940 and 1990. If you are carrying out alterations or repairs in an area that affects the integrity of asbestos, the work will need to be carried out in accordance with the guidance of Worksafe.
General Building Requirements – Residential Dwellings
APPLICANT TO COMPLETE ☐Not Applicable To Project COUNCIL TO COMPLETE ☐Vetting
(has there been information provided)
Mark if applicable and compliant, Highlight if RFI required.
Document ref or page # where information can be located
ID N
ot
Ap
plic
able
Compliance Method
Pro
cess
ing
Insp
ecti
on
Co
de
Cla
use
Processing/inspection notes if required
RFI questions and responses
☐Inspection not per consent out FM40
issued
F3 Hazardous Substances and Processes ☐Not Applicable to Project
R1512 ☐ Commercial storage of hazardous substances chemical types and volumes, (refer HSNO officer for approval )
☐ ☐ F5
R1513 ☐ Domestic Oil burners AS 1690 or work safe approved burners list. Domestic fuel storage max 2500 litres with more than 1200 req secondary containment. (ref E3/AS1 2.0 (erma’s Summary of approvals of substances transferred under the hazardous substances transfer notice)
☐ ☐ F5
R1514 ☐ Location test certificate or exempt laboratory ☐ ☐ F5
R1531 ☐ WC and basin locations and space dimensions (ref G1/AS1 sec 3.0-3.4)
☐ ☐
R1532 ☐ People with disabilities in Building Act schedule 2 buildings (ref G1/AS1 sec 4.0)
☐ ☐
R1533 ☐ Non-flushing WC (using chemicals or biological treatment) is it located so it will not cause a nuisance? Some may have special ventilation requirements) ref G1/AS1 sec 5)
General Building Requirements – Residential Dwellings
APPLICANT TO COMPLETE ☐Not Applicable To Project COUNCIL TO COMPLETE ☐Vetting
(has there been information provided)
Mark if applicable and compliant, Highlight if RFI required.
Document ref or page # where information can be located
ID N
ot
Ap
plic
able
Compliance Method
Pro
cess
ing
Insp
ecti
on
Co
de
Cla
use
Processing/inspection notes if required
RFI questions and responses
☐Inspection not per consent out FM40
issued
G5 Interior Environment ☐Not Applicable to Project
R1550 ☐ This does not apply to detached dwellings; household units within multi-unit dwellings; outbuildings or ancillary buildings
☐ ☐ G5
G6 Airborne and Impact Sound ☐Not Applicable to Project
R1551 ☐ Common wall (party wall) floor/ceiling, sound proofing between household units Type, system, construction details (ref G6/AS1)
☐ ☐ G6
R1552 ☐ Dwellings with in 80m of state highway construction to achieve 35dB in bedroom or 40dB in other habitable space (refer SDC district plan Rule Rural.1 (g))
General Building Requirements – Residential Dwellings
APPLICANT TO COMPLETE ☐Not Applicable To Project COUNCIL TO COMPLETE ☐Vetting
(has there been information provided)
Mark if applicable and compliant, Highlight if RFI required.
Document ref or page # where information can be located
ID N
ot
Ap
plic
able
Compliance Method
Pro
cess
ing
Insp
ecti
on
Co
de
Cla
use
Processing/inspection notes if required
RFI questions and responses
☐Inspection not per consent out FM40
issued
R1562 ☐ Specifications (pipe materials and appliance installation details) for hazardous liquids (boiler and freezer pipes, flammable, toxic and corrosive liquid pipes) and gas pipes appliances