GE Molded Case Circuit Breakers
Spectra RMS™ Circuit Breakers with MicroVersaTrip PM™ Trip Units1
MicroVersaTrip PM, Standard UL Rated (No Protective Relays)SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350SQL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
150
400
600
LITLSITLIGT®LSIGT®
LITLSITLIGT®LSIGT®
LITLSITLIGTfflLSIGT®
35kA
SGHB36CA0150SGHB36CB0150SGHB36CC0150SGHB36CD0150
SGHB36CA0400SGHB36CB0400SGHB36CC0400SGHB36CD0400
SGHB36CA0600• SGHB36CB0600
SGHB36CC0600SGHB36CD0600
$3797.005162.005007.006372.00
3797.005162.005007.006372.00
4751.006116.005961.007326.00
65kA
SGLB36CA0150SGLB36CB0150SGLB36CC0150SGLB36CD0150
SGLB36CA0400SGLB36CB0400SGLB36CC0400SGLB36CD0400
SGLB36CA0600SGLB36CB0600SGLB36CC0600SGLB36CD0600
$4952.006317.006162.007527.00
4952.006317.006162.007527.00
5705.007070.006915.008280.00
100kA
SGPB36CA0150SGPB36CB0150SGPB36CC0150SGPB36CD0150
SGPB36CA0400SGPB36CB0400SGPB36CC0400SGPB36CD0400
SGPB36CA0600SGPB36CB0600SGPB36CC0600SGPB36CD0600
$6132.007497.007342.008707.00
6132.007497.007342.008707.00
7080.008445.008290.009655.00
3- Polslug kitTCLK365
®$42.00
Aluminum:(2) %-500 kcmil
or(1) #6-600 kcmil
Copper:(2) %-400 kcmil
(1) #8-600 kcmil
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 403503-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2:1250A, 690 Vac Max. (SKL, SKP only)
4-30 1999 Issue Prices and data subject to change without notice
1I
GE Molded Case Circuit Breakers
K1200 Line• Thermal Magnetic Circuit Breakers• Magnetic Breakers• Molded-Case SwitchesThese breakers are available only with interchangeable trip units.Two frame sizes are available, the 800 ampere frame (300 to 800amperes) and the 1200 ampere frame (600 to 1200 amperes). Tripunits are not interchangeable between frames.
"Complete Circuit Breaker" price includes frame, trip, Cu/AI line,and load lugs. Units will be shipped unassembled unless specified"must be factory assembled." If line lugs are not required on thebreaker, eliminate "WL" from catalog number and subtract priceof line lugs.
To order the frame, trip, and lugs separately, select the requiredcomponents from table. Magnetic circuit breakers must beordered as components. A complete breaker consists of frame,trip and one line and one load lug per pole. Price of ordering"Complete Circuit Breaker" vs. frame, trip, and line and load lugsseparately is the same.
Molded-case switches can also be ordered as complete units(designated Type TKMA—Y) or as separate components. Theyare UL listed only as complete units. To indicate required lugs,see the table below.
x Unless otherwise noted, all circuit breakers are UL listed in FileE-11592. Molded-case switches are UL listed in File E-57546.R Frame—1000/1600/2000 Amp Molded-Case Circuit Breakers• Solid-state MicroVersaTrip Plus™ or MicroVersaTrip PM™
Trip Unit• Interchangeable trip unit via rating plugs• 65 and 100 kA ratings available• Standard and 100% rated versions• Uses standard Power Break* accessories• Stationary/manual onlyCurrent Limiting Circuit Breakers• 150, 225, 400 and 600 ampere frame sizes• UL listed interrupting ratings are 200 kA at 240 and 480 volts ac
maximum and 50 kA at 600 volts ac maximum• Thermal magnetic constructionCircuit Breakers with MicroVersaTrip' Trip Units• Solid-state construction with MicroVersaTrip RMS-9 digital rms
sensing microprocessor trip units.• Available in J and K frame construction with ampere ratings from
60-1200A.For ordering information see pages 4-36 through 4-41. UL listed,File E-11592. All breakers are UL listed in File E-11592.Tri-Break' Line• Integrally Fused Thermal Magnetic Circuit Breakers• Integrally Fused Magnetic Circuit Breakers• Integrally Fused Molded-Case Switches
Molded Case Circuit BreakersThese breakers are available in four types. Type TB1 (15-100amperes) catalog numbers include frame, trip, line and load lugs,and current limiters all factory assembled. Types TB4 (125 to 400amperes), TB6 (300 to 600 amperes) and TB8 (600 to 800 amperes)include frame, trip and limiters, factory assembled, but do notinclude line or load lugs. If line and load lugs are required, orderseparately. Unless otherwise noted, TB1, TB4, TB6, and TB8breaker components are UL listed in File E-42263. Fusedmolded-case switches are UL listed in File E-57546.Mag-Break9 Line• Magnetic only circuit breakers (motor circuit protectors)
These breakers are available only with noninterchangeableadjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break.All breakers are shipped factory assembled, complete with Cu/AIline and load lugs.
All magnetic only circuit breakers and limiters are UL ComponentRecognized in Files E-11592 and E-66390, respectively, unlessotherwise noted.
AccessoriesOrder accessories from the appropriate table:
Thermal Magnetic Circuit Breakers, Magnetic Circuit Breakers, andMolded-Case Switches®—pages 4-48 to 4-65.MicroVersaTrip RMS-9 or 4-function Solid-State Circuit Breakers— .pages 4-48 to 4-65.
Spectra RMS™ Breakers—pages 4-47 to 4-65.Spectra RMS™ Breakers with MicroVersaTrip Plus™ Trip Units orMicroVersaTrip PM™ Trip Units—pages 4-32 to 4-35 and 4-47 to 4-65.
Molded-Case Circuit Breaker and SwitchTerminal Configuration CodeOrder standard Cu/AI lugs by using suffix codes presented. Order lugsseparately if special lugs are required. For optional lugs, see page 4-62.
Spectra RMS™ Circuit Breakers UL/CSA RatingsSolid-State with Interchangeable Trip Unit
CircuitBreaker
TypeAmpereRating
No. Maximumac Voltage
Rating
UL Listed Interrupting Rating —rms Symmetrical Amperes (in Thousands)
240 Vac 480 Vac 1 600 Vac
FederalSpec.
C/B ClassW-C375B
DimensionsInches (mm)
H W D A B C E
Approx.Ship Wt./Std. Pack
SE150 Current Limiting (UL File No. E-11592; CSA LR 40350)®SED®
SEH@
SEL
SEP
15-150
15-150
232
'3
2323
480600480600
480600480600
1 8
65
100
200
1 8
25
65
100
—
14—
1 8
—25—25
13tp
18a13b,15b
22a13b,15b
21a,22a,23a16a
16a,23a
6.31(160)
4.12(105)
to3.38(86)
2 4 1(61)
2.47(63)
.69(18)
,72(18)
5.65 Ib/1
SF250 Current Limiting (UL File No. E-11592; CSA LR 40350)®SFH®
SFL
.SFP
70-250
70-250
232323
480600480600480600
' 6 5
100
200
35
65
100
—22—25—25
13b20a,22a13b
21a,23a16a
16a,23a
10.12(257)
4.12(105)
3.81(97)
3.87(98)
3.87(98)
.69(18)
1.19(30)
9.15IW1
G600 Current Limiting (UL File No. E-11592; CSA LR 40350)®SGH1®®
SGD®
SGH4®
SGH6®
SGLKJ
SGP1®
SGL4
SGP4
SGL6
SGP6
60-150
125-400
250-600
60-150
125-400
250-600
3
232323
3
3
23232323
600
240
600600600600
600
600
600600600600600600600600
65
65
65
65
100
200
100
200
100
200
35
-
35
35
65 •
100
65
100
65
100
25
25
25
65
65
65
65
65
65
21a,23a
14b
21a,23a
23a
23a
23a
23a
23a
24a
25a
10.09(256)
®
5.50(140)
3.81(97)
445(11.3)
3.30(84)
.91(23)
1 . 1 8(30)
®
15.85lb/1
SK1200 (UL File No. E-11592; CSA LR 40350)®SKH8
SKL8
SKP8
SKH12
SKL12
SKP12
300-800
600-1200
232323232323
600
600
600
600
600
600
65
100
200
65
100
200
50
65
100
50
65
100
25
42
65
25
42
65
21a,23a
24a
25a
21a,23a
24a
25a
15.50(394)
8.25(210)
550(140)
856(217)
5.69(145)
1.38(35)
62(16)
47.6 Ib/1
UL listed as HACR type.Not current-limiting circuit breaker.MicroVersaTrip Plus™ Trip Units and MicroVersaTrip PM™ Trip Units only.
® Includes MicroVersaTrip Plus Trip Units and MicroVersaTrip PMTrip Units.
® Add 1.76 inches (45mm) to each end with lugs and lug cover installed.® Add 4.00 inches (101mm) to upper end for SKP (100 kAIC-480V)
lug cover.
Data subject to change without notice 1999 Issue 4-5
GE Molded Case Circuit Breakers
Spectra RMS™ Circuit Breakers withMicroVersaTrip Plus™ Trip Units
How To Order:• Determine the required breaker frame (i.e., 150, 400, 600, 800,
or 1200 amperes), 1C rating, and load requirements (ULStandard or 100%). Determine overcurrent protective functions(LI, LSI, LIG, LSIG). Select frame catalog number and list pricefrom table on page 4-27.
• Select and price the required rating plug from table below. Thesensor rating of frame must match the sensor rating of the ratingplug in table.
• Select and price lugs and lug covers as required from page4-63.
• Select and price appropriate combination of Distribution CableSystem accessories from pages 4-32 to 4-34.
• Select and price any other accessories from page 4-35 and 4-47to 4-65.
• When ordering, specify separate catalog numbers as follows:—Frame—Rating Plug—Lugs—Distribution Cable Accessories—Other Accessories
Trip Function DefinitionsLong-Time (L)
Short-Time (S)
Instantaneous (I)
Ground Fault (G)
Trip Indication Targets
Control Power (CP)
Adjustable current settingAdjustable long-time delay
Adjustable short-time pick-upAdjustable short-time delay with ItAdjustable short-time delay without I't
Adjustable pick-up
Adjustable ground fault pick-upAdjustable ground fault delay with I'tAdjustable ground fault delay without I2t
Standard
+24 Vdc control power connection
Pricing ExampleSG600 frame, 400 ampere sensor, 400 ampere rating plug,100 kAIC, 100% rated. Trip functions to include long-time (L),short-time (S), instantaneous (I), and ground fault. 3-phase/4-wiresystem with 400 ampere neutral sensor. Load lugs only. 120 Vacshunt trip and two stage auxiliary switch (2AB) with signal levelcontacts.
4-26 1999 Issue Prices and data subject to change without notice
MicroVersaTrip PlusMolded-Case
Circuit Breaker _//Terminal Block L
Frame ' '
• _ Shunt Aux. n \• ~Tn'p Switch n 3 _____• ——— j 400 Amp•3 ———————~—I j c Neutralll| ______~~™L \m ———C Current
E*3 i c i r 8 SensorIJQ L.S.I.G_______ || —————
H |_[ lug* ~ I
1̂ NOTE: All Spectra RMS™ breakers with ground fault option will have a^H breaker cable If the breaker is connected to a 3<t>4w or 1 <£>3w^H service, a terminal.block or junction box is required for connection^H to the neutral current sensor.
GE Molded Case Circuit Breakers
Spectra RMS™ Circuit Breakers with MicroVersaTrip PMTrip UnitsMicroVersaTrip PM Trip UnitThe MicroVersaTrip PM trip unit adds power management systemcapability, advanced metering, and protective relays to the basic functionsof MicroVersaTrip Plus™. MicroVersaTrip PM trip units communicatedirectly on the GE POWER LEADER™ communications bus. Suitable foruse in applications from 45 Hz to 66 Hz. Not suitable for 400 Hz.
Standard Features• Adjustable Long-Time (L) pickup, 0.5-1.OX, and delay (3-4 bands),• Adjustable Instantaneous (I) pickup, 1.5-10X.• Local Overload and Short-Circuit Trip Indicators (T) with overload pickup
warning.• Interchangeable trip rating plugs with test set jack for TVRMS test set.• Digital LCD display with four-button keypad for function selection and set
point adjustment and scalable, clear Lexan® cover for tamper-resistantsettings.
• True rms sensing for accurate response to high harmonic contentwaveforms.EMI immunity per ANSI C37.90.POWER LEADER Communications System Link with user-selectableaddress assignment for COMNET communication.Metering3-Phase Ammeter with ±4% accuracy.3-Phase Voltmeter, ±2% @ 1X, configurable for Wye and Delta systems.Frequency Meter, ±1 HzkW Meter, ±7% (real power) ;
kVA Meter, ±6% (apparent power)kWh Meter, ±6% (energy)Control Power 24 Vdc provides connection capability for +24 Vdccontrol power into the breaker via the distribution cable system.
Optional Features• Adjustable Short-Time (S) pickup, 1.0-9.0C, and delay (4 bands) with I2t
IN/OUT selection.• Adjustable Ground fault (G) pickup, 0.2-1.OS, and delay (4 bands) with I2t
IN/OUT selection and trip indicator. The 4 short-time and ground faultdelay bands provide broader system selectivity.
TM
MicroVersaTrip PM Trip Unit Characteristics
• Protective Relays—User selectable in any combination from 1 to 5 relays—Current Unbalance Relay—Undervoltage Relay •—Overvoltage Relay—Voltage Unbalance Relay—Power Reversal Relay
Note: MicroVersaTrip PM functions require 24 Vdc control power andvoltage sensing signals.• Universal Internal Accessories—Uses the same front-mounted,
field-installable shunt trips, undervoltage releases, bell alarms, andauxiliary switches as standard Spectra RMS™ breakers.
• Accessory Lead Routing Left or Right—Side channels mean no extraspace required for accessory leads.
• Current Limiting—SG600 frames rated 65kA and 100kA @ 480 Vacare UL listed as current limiting.
• Reverse Feed—Front-mounted interchangeable rating plugs mean allframes are UL listed for reverse feed.
• Wide Current Setting Range—Interchangeable rating plugscombined with 5 current sensors and 0.5-1 .OX long time pickup yieldampere ratings from 30 to 1200A.
• 100% Continuous Current Rated—Optionally available for 100% ULcontinuous current rating applications.
available on SG frames.® Time delay at 600% of current
setting at lower limit of eachband.
® Time delay at 200% of pickupsetting at the lower limit ofeach band.
Time delay shown at lower limitof each band. Pickuptolerances ± 10%. GroundFault Pick-up not to exceed1200 amps.
11V§0
*fr
.
Functions
Amperes (A)Voltage (V)Energy (kWh/MWh)Real Power (kW/MW)Apparent Power (kVA/MVA)Frequency (45-66 Hz)
Voltage Unbalance Relay
Current Unbalance Relay
Undervoltage Relay
Overvoltage Relay
Power Reversal Relay
Communications
Accuracy and Description
Current ±4% Selectable PhaseVolts ±2% Selectable Phase in L-L or L-N <8Watt hours ± 7% Total energy flow, through breakerWans ±6% L-L or L-N Power®Volt amps ± 6% L-L or L-N Power OHertz ±6%
Adjustable pickup, 10 to 50%Adjustable delay. 1 to 15 seconds or OFFAdjustable pickup. 10 to 50%Adjustable delay. 1 to 15 seconds or OFFAdjustable pickup, 50 to 90%Adjustable delay, 1 to 15 seconds or OFFAdjustable pickup, 1 1 0 to 1 50%Adjustable delay, 1 to 15 seconds or OFFAdjustable pickup, 0.01 MW to .90 MWAdjustable delay, 1 to 15 seconds or OFF
POWER LEADER"1 Communications System Link (commnet)
PM Trip Unit
Metering (M)
XXXXXX
X
Metering and Relaying (PM)
XXX
5X
X
X
X
X
X
X
<4-28 1999 Issue Prices and data subject to change without notice