GE Germicidal LampsgG4T5
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
• Uses mini Bi-pin end caps
• 6000 hours Useful Life
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
5.35(135.9)Base face to end of opposite base pin (B) in. (mm)
5.53(140.5) 5.63(143)End of base pin to end of opposite pin end (C)
in. (mm) -- 5.91(150.1)Bulb Outside Diameter (D) in. (mm)
0.53(13.5) 0.63(16.0)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
G4T515872
24Physical Characteristics
Applicable Standardsno
RP-27.4-96
T5Soft Glass
- Turn power off before inspection, installation or removal
Electrical Characteristics
Risk of electric shock
Applicable Regulations
8.30.8
6,000
- Avoid exposure of eyes and skin to unshielded lamp
WarningLamp emits UV radiation which may cause eye/skin injury.
RG-3
429
170
253.7UV Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG4T5
UV Maintenance
0%
20%
40%
60%
80%
100%
120%
0 2000 4000 6000 8000 10000
Time (hours)
Rela
tive
UV O
utpu
t
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG6T5
• Uses mini Bi-pin end caps
• 6000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
8.35(212.1)Base face to end of opposite base pin (B) in. (mm)
8.53(216.7) 8.63(219.2)End of base pin to end of opposite pin end
(C) in. (mm) -- 8.91(226.3)Bulb Outside Diameter (D) in. (mm)
0.53(13.5) 0.63(16.0)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
G6T515873
24Physical Characteristics
T5Soft Glass
Electrical Characteristics642
160UV Characteristics
253.717.71.7
6,000Warning
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG6T5
UV Maintenance
0%
20%
40%
60%
80%
100%
120%
0 2000 4000 6000 8000 10000
Time (hours)
Rela
tive
UV O
utpu
t
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG8T5
• Uses mini Bi-pin end caps
•7500 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
11.35(288.3)Base face to end of opposite base pin (B) in. (mm)
11.53(292.9) 11.63(295.4)End of base pin to end of opposite pin end
(C) in. (mm) -- 11.91(302.5)Bulb Outside Diameter (D) in. (mm)
0.53(13.5) 0.63(16.0)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
24*2.3*
7,500Warning
570.145
UV Characteristics253.7
T5Soft Glass
Electrical Characteristics8
G8T511077
24Physical Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG8T5
Relative UV MaintenanceG8T5
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rela
tive
UV O
utpu
t
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG11T5
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
• Uses mini Bi-pin end caps
• 8000 hours Useful Life
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
8.35(212.1)Base face to end of opposite base pin (B) in. (mm)
8.53(216.7) 8.63(219.2)End of base pin to end of opposite pin end
(C) in. (mm) 8.91(226.3)Bulb Outside Diameter (D) in. (mm)
0.58(14.7) 0.64(16.3)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
noApplicable Standards
RP-27.4-96
- Avoid exposure of eyes and skin to unshielded lampRisk of
electric shock - Turn power off before inspection, installation or
removal
Applicable Regulations
2.28,000
Special CharacteristicsLamp emits UV radiation which may cause
eye/skin injury. RG-3
0.330UV Characteristics
253.722.9
Soft Glass
Electrical Characteristics1137
2949524
Physical CharacteristicsT5
G11T5
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG11T5
Relative UV MaintenanceG11T5
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rel
ativ
e U
V O
utpu
t
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG11T5/4P/SE
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
• Uses a single 4pin end cap• 8000 hours Useful Life
33mm 8.3mm
7.9mm
L
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (L) in. (mm)Bulb
Outside Diameter (D) in. (mm) 0.63(16.0)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
G11T5/4P/SE29500
24Physical Characteristics
T5Soft Glass
Electrical Characteristics1137
Special CharacteristicsLamp emits UV radiation which may cause
eye/skin injury. RG-3
0.330UV Characteristics
253.722.9
noApplicable Standards
RP-27.4-96
8.66(220)
- Avoid exposure of eyes and skin to unshielded lampRisk of
electric shock - Turn power off before inspection, installation or
removal
Applicable Regulations
2.28,000
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG11T5/4P/SE
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Relative UV MaintenanceG11T5/4P/SE
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rel
ativ
e U
V O
utpu
t
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG36T5
• Uses single-pin end caps
• 9000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
33.37(847.5)Base face to end of opposite base pin (B) in. (mm)
32.89(835.5) 33.72(856.5)End of base pin to end of opposite pin end
(C) in. (mm) -- 34.07(865.5)Bulb Outside Diameter (D) in. (mm)
0.53(13.5) 0.63(16.0)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
G36T515874
24Physical Characteristics
T5Soft Glass
Electrical Characteristics39
107425
UV Characteristics253.7109.5
129,000
WarningLamp emits UV radiation which may cause eye/skin injury.
RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of
electric shock - Turn power off before inspection, installation or
removal
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG36T5
UV Maintenance
0%
20%
40%
60%
80%
100%
120%
0 2000 4000 6000 8000 10000
Time (hours)
Rela
tive
UV O
utpu
t
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG36T5/4P/SE
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
• Uses a single 4pin end cap• 8000 hours Useful Life
33mm 8.3mm
7.9mm
L
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (L) in. (mm)Bulb
Outside Diameter (D) in. (mm) 0.64(16.3)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
G36T5/4P/SE29503
24Physical Characteristics
T5Soft Glass
Electrical Characteristics39115
Special CharacteristicsLamp emits UV radiation which may cause
eye/skin injury. RG-3
0.425UV Characteristics
253.7109.5
noApplicable Standards
RP-27.4-96
33.28(845.4)
- Avoid exposure of eyes and skin to unshielded lampRisk of
electric shock - Turn power off before inspection, installation or
removal
Applicable Regulations
12.09,000
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG36T5/4P/SE
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Relative UV MaintenanceG36T5/4P/SE
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rel
ativ
e U
V O
utpu
t
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG64T5
• Uses single-pin end caps
• 7500 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
61.30(1557)Base face to end of opposite base pin (B) in. (mm)
61.42(1560.1) 61.65(1565.9)End of base pin to end of opposite pin
end (C) in. (mm) 61.74(1568.2) 62.00(1574.8)Bulb Outside Diameter
(D) in. (mm) 0.53(13.5) 0.63(16.0)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
18518
7,500Warning
1800.425
UV Characteristics253.7
T5Soft Glass
Electrical Characteristics65
G64T515864
24Physical Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal Lampsg
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
G64T5
Relative UV MaintenanceG64T5
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rela
tive
UV O
utpu
t
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG64T5/4P/SE
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
• Uses a single 4pin end cap• 8000 hours Useful Life
33mm 8.3mm
7.9mm
L
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (L) in. (mm)Bulb
Outside Diameter (D) in. (mm) 0.64(16.3)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
G64T5/4P/SE29504
24Physical Characteristics
T5Soft Glass
Electrical Characteristics65
250
Special CharacteristicsLamp emits UV radiation which may cause
eye/skin injury. RG-3
0.425UV Characteristics
253.7200
noApplicable Standards
RP-27.4-96
61.28(1556.6)
- Avoid exposure of eyes and skin to unshielded lampRisk of
electric shock - Turn power off before inspection, installation or
removal
Applicable Regulations
25.09,000
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG64T5/4P/SE
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Relative UV MaintenanceG64T5/4P/SE
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rel
ativ
e U
V O
utpu
t
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG10T8
• Uses standard Bi-pin end caps
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
13.05(331.5)Base face to end of opposite base pin (B) in. (mm)
13.24(336.2) 13.33(338.6)End of base pin to end of opposite pin end
(C) in. (mm) -- 13.61(345.7)Bulb Outside Diameter (D) in. (mm)
1.05(26.7)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
G10T829498
24Physical Characteristics
T5Soft Glass
Electrical Characteristics9.546
0.230UV Characteristics
253.728.12.7
6,000Special Characteristics
Lamp emits UV radiation which may cause eye/skin injury.
RG-3
noApplicable Standards
RP-27.4-96
- Avoid exposure of eyes and skin to unshielded lampRisk of
electric shock - Turn power off before inspection, installation or
removal
Applicable Regulations
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG10T8
Relative UV MaintenanceG10T8
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rel
ativ
e U
V O
utpu
t
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG15T8
• Uses standard Bi-pin end caps
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
17.22(437.4)Base face to end of opposite base pin (B) in. (mm)
17.40(442) 17.50(444.5)End of base pin to end of opposite pin end
(C) in. (mm) 17.67(448.8) 17.78(451.6)Bulb Outside Diameter (D) in.
(mm) 0.94(23.9) 1.10(27.9)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
49*4.8*
8000*Warning
550.305
UV Characteristics253.7
T8Soft Glass
Electrical Characteristics15
G15T811078
24Physical Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal Lampsg
Relative UV MaintenanceG15T8
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rela
tive
UV O
utpu
t
G15T8
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG25T8
• Uses standard Bi-pin end caps
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
17.22(437.4)Base face to end of opposite base pin (B) in. (mm)
17.40(442) 17.50(444.5)End of base pin to end of opposite pin end
(C) in. (mm) 17.67(448.8) 17.78(451.6)Bulb Outside Diameter (D) in.
(mm) 0.94(23.9) 1.10(27.9)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
70*6.9*
8000*Warning
460.580
UV Characteristics253.7
T8Soft Glass
Electrical Characteristics25
G25T811082
24Physical Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal Lampsg
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
G25T8
Relative UV MaintenanceG25T8
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rela
tive
UV O
utpu
t
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG30T8
• Uses standard Bi-pin end caps
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
35.22(894.6)Base face to end of opposite base pin (B) in. (mm)
35.40(899.2) 35.50(901.7)End of base pin to end of opposite pin end
(C) in. (mm) 35.67(906.0) 35.78(908.8)Bulb Outside Diameter (D) in.
(mm) 0.94(23.9) 1.10(27.9)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
G30T811080
24Physical Characteristics
T8Soft Glass
Electrical Characteristics3099
0.355UV Characteristics
253.7125*12.4*8000*
WarningLamp emits UV radiation which may cause eye/skin injury.
RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of
electric shock - Turn power off before inspection, installation or
removal
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal Lampsg
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
G30T8
Relative UV MaintenanceG30T8
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rela
tive
UV O
utpu
t
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG36T8
• Uses standard Bi-pin end caps
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
47.22(1199.4)Base face to end of opposite base pin (B) in. (mm)
47.41(1204.1) 47.50(1206.5)End of base pin to end of opposite pin
end (C) in. (mm) -- 47.78(1213.6)Bulb Outside Diameter (D) in. (mm)
0.96(24.3) 1.05(26.7)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
G36T829499
24Physical Characteristics
T5Soft Glass
Electrical Characteristics36
1030.430
UV Characteristics253.714514.68,000
Special CharacteristicsLamp emits UV radiation which may cause
eye/skin injury. RG-3
noApplicable Standards
RP-27.4-96
- Avoid exposure of eyes and skin to unshielded lampRisk of
electric shock - Turn power off before inspection, installation or
removal
Applicable Regulations
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG36T8
Relative UV MaintenanceG36T8
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rel
ativ
e U
V O
utpu
t
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG55T8/HO
• Uses medium bi-pin end caps
• High-Output UV emitter
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
35.22(894.6)Base face to end of opposite base pin (B) in. (mm)
35.40(899.2) 35.50(901.7)End of base pin to end of opposite pin end
(C) in. (mm) 35.40(899.2) 35.78(908.8)Bulb Outside Diameter (D) in.
(mm) 0.94(23.9) 1.10(27.9)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
19418
8,000Warning
830.770
UV Characteristics253.7
T8Soft Glass
Electrical Characteristics55
G55T8/HO15875
24Physical Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal Lampsg
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
G55T8/HO
Relative UV MaintenanceG55T8/HO
00.20.40.60.8
11.2
0 2000 4000 6000 8000 10000Time (hours)
Rela
tive
UV O
utpu
t
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG20T10
• Uses standard Bi-pin end caps
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
23.22(589.8)Base face to end of opposite base pin (B) in. (mm)
23.40(594.4) 23.50(596.9)End of base pin to end of opposite pin end
(C) in. (mm) -- 23.78(604)Bulb Outside Diameter (D) in. (mm)
1.22(31.0) 1.34(34.0)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA RP-27.4-96
- Turn power off before inspection, installation or
removalApplicable Regulations
noApplicable Standards
Special CharacteristicsLamp emits UV radiation which may cause
eye/skin injury. RG-3 - Avoid exposure of eyes and skin to
unshielded lampRisk of electric shock
8,000
G20T1015876
24Physical Characteristics
1958
0.360
253.7
7.575.8
Electrical Characteristics
T5Soft Glass
UV Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG20T10
Relative UV MaintenanceG20T10
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rel
ativ
e U
V O
utpu
t
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG40T10
• Uses standard Bi-pin end caps
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb Material
Dimensions Min MaxBase face to base face (A) in. (mm)
47.22(1199.4)Base face to end of opposite base pin (B) in. (mm)
47.40(1204) 47.50(1206.5)End of base pin to end of opposite pin end
(C) in. (mm) -- 47.78(1213.6)Bulb Outside Diameter (D) in. (mm)
1.34(34.0)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
G40T1029532
24Physical Characteristics
T5Soft Glass
Electrical Characteristics40106
0.420UV Characteristics
253.720019.8
8,000Special Characteristics
Lamp emits UV radiation which may cause eye/skin injury.
RG-3
noApplicable Standards
RP-27.4-96
- Avoid exposure of eyes and skin to unshielded lampRisk of
electric shock - Turn power off before inspection, installation or
removal
Applicable Regulations
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgG40T10
Relative UV MaintenanceG40T10
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rel
ativ
e U
V O
utpu
t
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal Lampsg
• Uses single-end 4-pin cap
• 9000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
33mm
8.3mm7.9m
mL
GPH793/T5/4
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb MaterialBase -- non-integral single ended 4
pin ceramic base
Dimensions Min MaxBase face to base face (A) in. (mm)
31.34(796)Base face to end of opposite base pin (B) in. (mm) --
--End of base pin to end of opposite pin end (C) in. (mm) -- --Bulb
Outside Diameter (D) in. (mm) 0.53(13.5) 0.63(16.0)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
13112.8
9,000Warning
1050.425
UV Characteristics253.7
T5Quartz
Electrical Characteristics37
GPH793T5L/4P46630
12Physical Characteristics
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgGPH793/T5/4
UV Maintenance
0%
20%
40%
60%
80%
100%
120%
0 2000 4000 6000 8000 10000
Time (hours)
Rela
tive
UV O
utpu
t
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgGBX5/UVC
• Uses single-end G23
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
H
C
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb MaterialBase -- non-integral single ended 4
pin ceramic base
Dimensions Min MaxBase DimensionsBase face to top of lamp
diemsnion--H in. (mm) -- 3.35(85.0)width of lamp dimension C in.
(mm) -- 1.28(32.5)depth of lamp dimension G in. (mm) --
0.71(18.1)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
18,000
Warning
350.180
UV Characteristics253.7
T4Soft Glass
Electrical Characteristics5
G23
GBX5/UVC16479100
Physical Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgGBX9/UVC
• Uses single-end G23
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
H
C
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb MaterialBase -- non-integral single ended 4
pin ceramic base
Dimensions Min MaxBase DimensionsBase face to top of lamp
diemsnion--H in. (mm) -- 5.71(145)width of lamp dimension C in.
(mm) -- 1.28(32.5)depth of lamp dimension G in. (mm) --
0.71(18.1)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
2.48,000
Warning
590.180
UV Characteristics253.7
T4Soft Glass
Electrical Characteristics9
G23
GBX9/UVC15877100
Physical Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgGBX11/UVC
• Uses single-end G23
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
H
C
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb MaterialBase -- non-integral single ended 4
pin ceramic base
Dimensions Min MaxBase DimensionsBase face to top of lamp
diemsnion--H in. (mm) -- 8.46(215)width of lamp dimension C in.
(mm) -- 1.28(32.5)depth of lamp dimension G in. (mm) --
0.71(18.1)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
3.68,000
Warning
890.160
UV Characteristics253.7
T4Soft Glass
Electrical Characteristics11
G23
GBX11/UVC15879100
Physical Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgGBX13/UVC
• Uses single-end G23
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
H
C
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb MaterialBase -- non-integral single ended 4
pin ceramic base
Dimensions Min MaxBase DimensionsBase face to top of lamp
diemsnion--H in. (mm) -- 6.69(170)width of lamp dimension C in.
(mm) -- 1.28(32.5)depth of lamp dimension G in. (mm) --
0.71(18.1)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
GBX13/UVC15879100
Physical CharacteristicsT4
Soft Glass
Electrical Characteristics13
G23
590.285
UV Characteristics253.7
3.68,000
WarningLamp emits UV radiation which may cause eye/skin injury.
RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of
electric shock - Turn power off before inspection, installation or
removal
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgC
H
GBX18/UVC/2G11
• Uses single-end G2-11
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb MaterialBase -- non-integral single ended 4
pin ceramic base
Dimensions Min MaxBase DimensionsBase face to top of lamp
diemsnion--H in. (mm) -- 8.8(225)width of lamp dimension C in. (mm)
-- 1.73(44)depth of lamp dimension G in. (mm) -- 0.9(24)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance† @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
GBX18/UVC/2G1115882
40Physical Characteristics
T6Soft Glass
Electrical Characteristics18
2G11
590.380
UV Characteristics253.7
695.3
8,000Warning
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
† measured perpendicular to the biax plane
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgC
H
GBX36/UVC/2G11
• Uses single-end G2-11
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb MaterialBase -- non-integral single ended 4
pin ceramic base
Dimensions Min MaxBase DimensionsBase face to top of lamp
diemsnion--H in. (mm) -- 16.33(415)width of lamp dimension C in.
(mm) -- 1.73(44)depth of lamp dimension G in. (mm) -- 0.9(24)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance† @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
15512
8,000Warning
1070.440
UV Characteristics253.7
T6Soft Glass
Electrical Characteristics36
2G11
GBX36/UVC/2G1115882
40Physical Characteristics
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
† measured perpendicular to the biax plane
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgC
H
GBX55/UVC/2G11
• Uses single-end G2-11
• 8000 hours Useful Life
Benefits• UV output at 254 nm; emits no ozone
• Effective in killing most microorganisms
Product DescriptionProduct CodeCase Quantity
Bulb DesignationBulb MaterialBase -- non-integral single ended 4
pin ceramic base
Dimensions Min MaxBase DimensionsBase face to top of lamp
diemsnion--H in. (mm) -- 21.1(535)width of lamp dimension C in.
(mm) -- 1.73(44)depth of lamp dimension G in. (mm) -- 0.9(24)
Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at
25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A
rms
Peak Emission Wavelength nmIrradiance† @ 1m, 254 nm, 100 hrs
µW/cm2
UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial
output) Hours
DoE regulated (yes/no)
ANSI/IESNA
GBX55/UVC/2G1115885
25Physical Characteristics
T6Soft Glass
Electrical Characteristics55
2G11
1010.550
UV Characteristics253.724016.5
8,000Warning
Lamp emits UV radiation which may cause eye/skin injury. RG-3 -
Avoid exposure of eyes and skin to unshielded lampRisk of electric
shock - Turn power off before inspection, installation or
removal
Applicable Regulationsno
Applicable StandardsRP-27.4-96
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
† measured perpendicular to the biax plane
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
GE Germicidal LampsgGermicidal Biax Lamps
Percent IrradianceGermicidal Lamps
0%
20%
40%
60%
80%
100%
100 200 300 400 500 600
Wavelength (nm)
Germicidal Effectiveness
0%
20%
40%
60%
80%
100%
200 225 250 275 300 325
Wavelength (nm)
Rela
tive
Effe
ctiv
enes
s
254 nm
Relative UV Maintenance
0
0.2
0.4
0.6
0.8
1
1.2
0 2000 4000 6000 8000 10000
Time (hours)
Rel
ativ
e U
V O
utpu
t
Turn power off and let lamp cool before removal to avoid
potential burn and electrical shock hazard during lamp
replacement.
All values are design values or typical values when measured
under laboratory conditions. Information provided is subject to
change without notice. Germicidal efficacy is dependant upon use of
proper engineering design guidelines & UV dosage.
Where applicable, values are based on guidelines published in
ANSI.
* Values shown are based on preliminary engineering
estimates
AaronINT Stamp
http://www.interlight.biz
-
UV lamps forgermicidal applications.Water, air and surface
sterilization.
GE Consumer & IndustrialSpecialty Lighting
imagination at work
AaronINT Stamp
http://www.interlight.biz
-
Germicidal LampsLinear fluorescent and compact fluorescent
types
GE Germicidal lamps use a special glass thattransmits
ultra-violet light in a spectral bandthat can be effective for
sterilization. A proventechnology for the destruction of
air-bornebacteria, viruses and mold spores.Improved system
efficiency when installed inHVAir Conditioning (HVAC) units by
reducingbacterial and mold growth. The UVCwavelength of 254 nm will
inactivate bacteria,viruses, mold, and cysts by preventing
DNAreplication.
AaronINT Stamp
http://www.interlight.biz
-
Germicidal ApplicationsUV lamps for germicidal applications.
Water, air and surfacesterilization.HealthcareUVC is used to reduce
the spread of disease, protecting both patients and staff. UV
fixtures are often found in areaswhere the risk of infection is
greatest; such as immuno-compromised patient areas or where the
probability oftransmission is high.
Processing IndustryFood may be irradiated to prevent growth of
mold and other dangerous organisms before it is packaged. This
helpsensure food safety and extends shelf life. UVC lamps are also
used within the facility to limit the exposure of foodproducts to
airborne micro-organisms.
Scientific LabsIn industries that demand a clean, sterile
environment, UVC is used to limit the amount of ‘live’ organisms in
the air,and to sterilize equipment and surfaces when employees are
not in the room.
Industrial, Municipal, Residential Water and Pond
TreatmentSpecial UVC lamps are used in some treatment applications
as a means of disinfection. This technology serves as areplacement
for chlorination in waste water treatment and as an additional
protective barrier in drinking andprocess water applications.Lamps
are now widely used in Pond cleansing for both domestic and
commercial uses.
Commercial buildingsUVC lamps are used as a means of improving
HVAC system efficiencies by irradiating coils and keeping them
frombuilding up with mold and other bacteria, which reduces the
flow rate and costs more to operate. These lamps canalso be
installed in-duct as a means of improving indoor air quality.
Food processing industry• Food processing• Food handling•
Warehousing• Produce department• Meat cases• Salad bars• Dessert
cases• Bakeries• Buffets• Restaurants
Biotech industry• Bioengineering• Genetics• Medical testing•
Pharmaceutical processes• Research labs• Biotech labs• Equipment
sterilization
AaronINT Stamp
http://www.interlight.biz
-
Germicidal lamps range
GE Consumer & Industrial is constantly developing and
improving its products. For this reason, allproduct descriptions in
this brochure are intended as a general guide, and we may
changespecifications time to time in the interest of product
development, without prior notification or publicannouncement. All
descriptions in this publication present only general particulars
of the goods towhich they refer and shall not form part of any
contract. Data in this guide has been obtained incontrolled
experimental conditions. However, GE Consumer & Industrial
cannot accept any liabilityarising from the reliance on such data
to the extent permitted by law.Germicidal Lamps - English - January
2006
and General Electric are both registered trademarks of the
General Electric Company, USA
© General Electric Company (USA) 2006
Length Length Product UV Output Irradiance Rated Pack
ProductWatt inch mm Description (Watts) (µW/cm2) Life Hours Qty
CodeGermicidalSoft Glass UV Output (Watts) Efficacy
T5 Germicidal4 5.91 150.1 G4T5 0.9 8.3 6000 24 158726 8.91 226.3
G6T5 1.7 17.7 6000 24 158738 11.91 302.5 G8T5 2.3 24.0 7500 24
11077
11 226.3 8.91 G11T5 2.2 22.9 8000 24 2949516 11.91 302.5 G16T5
3.2 33.0 8000 24 1649436 34.07 865.5 G36T5 12 109.5 9000 24 1587464
62.00 1574.8 G64T5 18 185.0 7500 24 15864
T5 Germicidal Single 4pin cap11 8.66 220 G11T5/4P/SE 2.2 22.9
8000 24 2950016 12.61 320.3 G16T5/4P/SE 3.4 33.0 8000 24 2950236
33.28 845.4 G36T5/4P/SE 12 109.5 9000 24 2950364 61.28 1556.6
G64T5/4P/SE 25 200.0 9000 24 29504
T5 Germicidal Single 4pin cap37 31.34 796 GPH793T5L/4P 12.8
131.0 9000 12 46630
T8 Germicidal10 13.61 345.7 G10T8 2.7 27.6 6000 24 2949815 17.78
451.6 G15T8 4.8 49.0 8000 24 1107825 17.78 451.6 G25T8 6.9 70.0
8000 24 1108230 35.78 908.8 G30T8 12.4 125.0 8000 24 1108036 47.78
1213.6 G36T8 14.6 145.0 8000 24 2949955 35.78 908.8 G55T8HO 18
194.0 8000 24 15875
T10 Germicidal20 23.78 604 G20T10 7.5 75.8 8000 24 1587640 47.78
1213.6 G40T10 19.8 200.0 8000 24 29532
Biax™ Germicidal5 3.35 85.0 GBX5/UVC G23 1.0 9.0 8000 100 406959
5.71 145.0 GBX9/UVC G23 2.4 22.0 8000 100 40696
11 8.46 215.0 GBX11/UVC G23 3.6 33.0 8000 100 4070013 6.69 170.0
GBX13/UVC GX23 3.6 31.0 8000 100 4070318 8.8 225.0 GBX18/UVC/2G11
5.3 51.0 8000 40 15882/4070436 16.33 415 GBX36/UVC/2G11 12 110.0
8000 40 15883/4070555 21.1 535 GBX55/UVC/2G11 16.5 156.0 8000 25
15885/40706
AaronINT Stamp
http://www.interlight.biz
-
SPECIALTYLIGHTINGLIGHTING
GE Lighting
UV lamps for germicidal applications...water, air and surface
sterilization.
GE Germicidal lamps use a special UV transmitting glass that
canbreak down ultraviolet light in a spectral band for
sterilization.
The UVC wavelength of 254 nm will inactivate bacteria,
viruses,mold, and cysts by preventing DNA replication.
Typical Applications Areas
Healthcare: UVC is used to reducethe spread of disease,
protectingboth patients and staff. UV fixturesare often found in
areas where therisk of infection is greatest; such asimmuno
compromised patientareas or where the probability oftransmission is
high.
Food Processing Industry: Foodmay be irradiated to preventgrowth
of mold and other dangerous organisms before it is packaged. This
helps ensurefood safety and extends shelf life.UVC lamps are also
used withinthe facility to limit the exposureof food products to
airbornemicro-organisms.Scientific Labs: In industries thatdemand a
clean, sterile environment, UVC is used to limit the amount
of ‘live’ organisms in the air, and to sterilize equipment and
surfaces whenemployees are not in the room.Industrial, Municipal
and ResidentialWater Treatment: Special UVC lamps areused in some
treatment applications as ameans of disinfection. This
technologyserves as a replacement for chlorinationin waste water
treatment and as an additional protective barrier in drinkingand
process water applications.
GE SPECIALTY LIGHTING / GERMICIDAL LAMPS
germicidal product sheet-revise 2/5/04 9:48 PM Page 1
AaronStamp for PDF
www.interlight.biz
-
GE SPECIALTY LIGHTING / GERMICIDAL LAMPS
imagination at work
26153 (2/04)Printed in USA
For complete Germicidal Lighting product information, visit the
GE Website at www.gelighting.com
germicidal product sheet-revise 2/5/04 9:51 PM Page 2
AaronStamp for PDF
www.interlight.biz