UL Listed and CSA Certified—for heat rise, short-circuit, andground fault.Interlocks and Safety Features—door interlock, pluginterlock, ground contact before stab contact, and plug assistfor mechanical installation.
® Not for Spectra breakers. E and F frame enclosures for standardmolded case circuit breakers only.
16-36 1999 Issue Prices and data subject to change without notice
GE Busway
Busway—Plug Short-Circuit RatingsFusible Switch Busway PlugsFusible switches in all busway fittings (plugs, power takeoffs, andreducers) have the following short-circuit ratings when used withthe fuses shown. To qualify for R fuse rating, switches must haveR fuse clips which reject other type fuses. The interrupting ratingof the fuse must equal or exceed the short-circuit rating of theswitch. If it is lower than the short-circuit rating of the switch, thenthe combination has the rating of the fuse.
16-4 1999 Issue Data subject to change without notice
GE Busway
Features/BenefitsEasy Install:• New Joint-Guard™ Protection System—dynamically
indicates proper torque through color! Easy install andmaintenance!
• Lighter Weight—means it installs faster than other buswaysand beats wire and conduit for total installed cost.
• Single Drop-Rod Hanger—is furnished with straight lengthsfor easy, fast installation.
• Field-Adjustable Isolation Joint—(± W per joint) provideson-site flexibility.
• Adjustable Straight Length—can eliminate the need for fieldcheck pieces! (±6" from nominal 54").
Performance/Protection/Maintenance:• Exclusive BlueCoat™ Epoxy Insulation—(Class B, UL
130°C) provides the industry's best protection (50 years).• Earth-Bond™ Integrated Grounding System—provides a
lower resistance ground path than internal ground bars.• IP4X Plug Outlet—GE's exclusive plug outlet provides the
industry's highest protection. It's "dead front" is fingerproof andscrewdriver-proof (Also meets IP2X and IP3X.)
• Belleville Spring Washer—the industry's best, retains over90% of original contact pressure, offering a maintenance-freejoint if torqued properly.
Spectra Series LowArnp Busway Catalog Numbering System
Spectra Series™ LowAmp BuswayApplication and Pricing
Available RatingsAmperes: 225 to 800 amperesVoltage: 600 Volts or lessBusing: Aluminum or CopperSystems: 3-phase, 3-wire and 3-phase, 4-wire (full neutral)Enclosures: Indoor, drip-proof, (totally enclosed)
Spectra Series LowAmp Busway Pricing• Catalog number pricingUse the catalog numbers from tables, or parametric catalognumber generation, on pages 16-28 through 16-33 to pricebusway components individually. One standard flatwise clevis-type hanger is provided with every straight length. Optionalhangers are available and ordered separately.
Product
Type
Service
Ground
Conductor
Description
Spectra Series LowAmp
FeederPlug-In >
3PH, 3W3PH.4W 100% Neutral
Integrated HousingInternal Bus '
CopperAluminum
Configurations
Straight LengthElbow-LettElbow-RightElbow-UpElbow-DownCenter Cable Tap Box-UpCenter Cable Tap Box-DownEnd Cable Tap Box-UpEnd Cable Tap Box-DownEnd BoxFlanged EndFlanged End w/LugsAdjustable Straight-LengthExpansion Length-UpExpansion Length-DownTotal Phase TranspositionTee-RightTee-LeftTee-UpTee-DownOff Set-UpOff Set-DownOff Set-RightOff Set-Left
Prices and data subject to change without notice 1999 Issue 16-29
GE Busway
Spectra Series™ LowAmp BuswayDimensions
TOP EDGEOFBUSWAY
Figure ADoor hinges at left end. All dimensionsare shown over largest part of plug.
Figure BDoor hinges at top. All dimensionsare shown over largest part of plug.
Fittings—Elbows, Tees, and OffsetsSpectra Series™ LowAmp busway has acomplete family of standard catalog fittingsto meet virtually all layout requirementsusing the compact minimum sizes shown.Nomenclature for completely defining theturn is accomplished by looking into thejoint end with phase 0 side facing down onthe busway. Using this guideline, a rightelbow turns right, an up elbow turns up, etc.Every piece of busway is labeled to maintainproper phasing. Unless otherwise noted, allturn dimensions are defined from thecenterline of the joint end to the centerlineof the busway. Figures show dimensionsfor elbow, tee, and offset fittings.
Molded-Case Circuit Breakers(Outer Dimensions)
Type
Standardand
Hi-Break*
Low- andMid-Tier
Frame
TEBTED, THEDTED, THED
SED, SEH, SELSFH, SFL
TripRange
15-10015-100
110-150
15-15070-225
VoltageRating
240600600
480600
Dimension(Inches)
W
11
1111
L
13
1321'/4
D
8
89
Fig.No.
A
A
Fusible Switches(Outer Dimensions)
Type
QMR
VoltageRating
240and600
Amps
30
60
100
200
400
Weight(Ibs.)
24
25
28
46
135
Dimensions (Inches)
W
11.25
16.00
20.50
Length
StandardGutter
13.00
18.75
ExtendedGutter
18.63
NA
24.50
NA
D
8.75
18.75
Fig.
A
B
0SIDC UJ.JTDOWN