WATER HEATER OR FURNACE FLUE, TYP. STAGGER GYP. BOARD. CORNERS, TYP. 2 LAYERS 5/8" TYP 'X' GYP BOARD. TYP. (BOTH SIDES) 2X FRAMING PER PLAN. TYP. CORRIDOR 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED). FIRE TAPE ALL GYP. BD. WALL JOINTS. WOOD SHEATHING PANEL. SEE STRUCTURAL SHEARWALL SCHEDULE. 2 x 6 WOOD STUDS. SEE STRUCTURAL FOR SPACING. ACOUSTIC BATT INSULATION BLANKETS. COORDINATE DEPTH WITH WALL THICKNESS. RESILIENT CHANNEL @ 16" O.C. RESILIENT CHANNELS 16" O.C. ATTACHED AT RIGHT ANGLES TO ONE SIDE OF 2 X 6 WOOD STUDS 24" O.C. WITH 1 1/4" TYPE S DRYWALL SCREW. ONE LAYER 5/8" TYPE "X" GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO CHANNELS WITH 1" TYPE S SCREWS 8" O.C. WITH VERTICAL JOINTS LOCATED MIDWAY BETWEEN STUDS. 3" MINERAL OR GLASS FIBER INSULATION IN STUD SPACE. OPPOSITE SIDE: ONE LAYER 5/8" TYPE "X" GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TO STUDS WITH 6d CEMENT COATED NAILS, 1 7/8" LONG, 0.0915 SHANK, 15/64" HEADS, 7" O.C. VERTICAL JOINTS STAGGERED 24" ON OPPOSITE SIDES. (LOAD-BEARING) UNIT (2) LAYERS 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED) EA. SIDE. FIRE TAPE ALL GYP. BD. WALL JOINTS. EXTERIOR GYP. BD. TO BE USED AT ALL EXTERIOR FACES OF BUILDING. 2 x 6 WOOD STUDS. SEE STRUCTURAL FOR SPACING. 5-1/2" SOUND BATT AT INTERIOR DEMISING WALLS. SHEATHING PER STRUCTURAL ASSEMBLY : GA WP 4136 FIRE TEST : SWRI 01-5920-614, 12-5-94 SOUND TEST : NGC 2363 4-1-70 STC : 40-44 RATING : 2HR BASE LAYER 5 8 " TYPE X GYPSUM WALLBOARD OR VENEER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 2x4 WOOD STUDS 16" O.C. WITH 1 1 4 " TYPE W DRYWALL SCREWS 12" O.C. FACE LAYER 5 8 " TYPE X GYPSUM WALLBOARD OR VENEER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE WITH 1 7 8 " TYPE W DRYWALL SCREWS 12" O.C. AND OFFSET 6" FROM SCREWS IN BASE LAYER. JOINTS STAGGERED 16" EACH LAYER AND SIDE. (LOAD BEARING) ASSEMBLY : GA WP 3242 FIRE TEST : UL R14196, 05NK05371, 2-15-05 UL DESIGN U309 RATING : 1HR SOUND TEST: NRCC TL-93-098 IRC-IR-761, 3/98 APPROVED UL LISTED 2 HOUR RATED SHAFT WALL ASSEMBLY TO CLOSE SHAFT AFTER FLUE INSTALLATION WITH C-T OR C-H STUDS PER ASSEMBLY. SEE DETAIL 10/F1.08 INTERIOR POSSIBLE WOOD SHEATHING PANEL. (SHEATHING MAY OCCUR ON BOTHSIDES) SEE STRUCTURAL SHEARWALL SCHEDULE. 2 x WOOD STUDS (DOUBLE WALL SPACED @ 1" APART). SEE STRUCTURAL FOR SPACING. R-11 BATTS EACH WALL. 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED) EA. SIDE. FIRE TAPE ALL GYP. BD. WALL JOINTS. 10 1/2" 1" INTERIOR ASSEMBLY : GA WP 5508 FIRE TEST : UL R14196, 3-13-06 UL 341 SOUND TEST : RAL TL11-160, 7-11-11 STC : 55-59 RATING : 1HR FLOOR JOISTS PER STRUCTURAL DRAWINGS 1" GYP CRETE OVER ACOUSTI-MAT 2 FLOOR SHEATHING PER STRUCTURAL DRAWINGS CONTINUOUS 6" ACOUSTIC BATTING SECURED TO UNDERSIDE OF SUBFLOOR BASE LAYER: 1 2 " PROPRIETARY TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO RESILIENT FURRING CHANNELS 24" O.C. (16" O.C. WHEN INSULATION IS USED) WITH 1 " TYPE S DRYWALL SCREWS 16" O.C. GYPSUM BOARD END JOINTS LOCATED MIDWAY BETWEEN CONTINUOUS CHANNELS AND ATTACHED WITH SCREWS 8" TO ADDITIONAL PIECES OF CHANNEL 60" LONG LOCATED 3" BACK ON EITHER SIDE OF END JOINT. RESILIENT CHANNELS APPLIED AT RIGHT ANGLES TO MINIMUM 10" DEEP WOOD I-JOISTS SPACED A MAXIMUM OF 19" O.C. WITH 1 1 4 " TYPE S DRYWALL SCREWS. FACE LAYER: 1 2 " PROPRIETARY TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGELS TO RESILIENT FURRING CHANNELS WITH 1 5 8 " TYPE S DRYWALL SCREWS 8" O.C. AND 1 1 2 " TYPE G SCREWS 8" O.C. AT THE BUTT JOINTS LOCATED MID-SPAN BETWEEN THE RESILIENT CHANNELS. GLASS FIBER INSULATION SECURED TO SUBFLOOR OR LOOSE FILL INSULATION APPLIED DIRECTLY OVER GYPSUM BOARD. WOOD I JOISTS SUPPORTING 19 32 " WOOD STRUCTURAL PANEL SUBFLOOR APPLIED AT RIGHT ANGLES TO JOISTS WITH CONSTRUCTION ADHESIVE AND 6d RING SHANK NAILS 12" O.C. MINIMUM 1 2 " PROPRIETARY GYPSUM FLOOR TOPPING APPLIED OVER SUBFLOOR. STC RATED WITH I JOISTS SPACED 24" O.C., 3 1 2 " GLASS FIBER INSULATION IN JOIST SPACES, 3 4 " PROPRIETARY GYPSUM FLOOR TOPPING POURED OVER 1 4 " PROPRIETARY SOUND REDUCTION MAT, AND WITH FINISH FLOORING OF SHEET VINYL, ENGINEERED WOOD LAMINATE, AND CERAMIC TILE. (STC 63 WHEN SHEET VINYL OR ENGINEERED WOOD LAMINATE IS APPLIED TO FLOOR; STC 66 WHEN TESTED WITH CERAMIC TILE APPLIED TO FLOOR.) ASSEMBLY: GA FC 5011 FIRE TEST: UL R1319, 05NK04589, 2-4-05; UL R1319, 05NK09496, 3-31-05; UL DESIGN L570 SOUND TEST: RAL OT03-05, 4-22-03; RAL OT03-07, 4-29-03; RAL OT03-09, 6-18-03 IIC & TEST: (58 SHEET VINYL), RAL OT03-06, 4-22-03 (62 ENGINEERED WOOD LAMINATE) RAL OT03-08, 4-29-03; (54 CERAMIC TILE) RAL OT03-10, 6-18-03 RATING : 1HR PROPRIETARY GYPSUM COMPONENTS UNITED STATES GYPSUM COMPANY - 1 2 " SHEETROCK BRAND FIRECODE C CORE GYPSUM PANELS - LEVELROCK BRAND FLOOR UNDERLAYMENT (2) LAYERS OF 1/2" TYPE "X" GYP. BOARD (TAPED, SANDED & PAINTED) EACH SIDE. FIRE TAPE ALL GYP. BOARD WALL JOINTS. 1/2" RESILIENT CHANNELS @ 16" O.C. INTERIOR EXTERIOR 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED). FIRE TAPE ALL GYP. BD. WALL JOINTS. WOOD SHEATHING PANEL. SEE STRUCTURAL SHEARWALL SCHEDULE. FIRE RATED CDX @ BREEZEWAYS. 2 x 6 WOOD STUDS. SEE STRUCTURAL FOR SPACING. CONTINUOUS BATT INSULATION BLANKETS (R-23) EXTERIOR FINISH INSTALLED AS PER MANUFACTURERS SPECIFICATIONS. SEE EXTERIOR ELEVATIONS. APPROVED EXTERIOR BUILDING WRAP. VAPOR BARRIER ON INTERIOR SIDE. CALCULATED FIRE RATING: WOOD STUDS AT 16" O.C.- 20MIN. IBC 722.6.2(2) 5 8 " TYPE X GYP. BOARD- 40MIN. IBC 722.2.1.4(2) TOTAL- 60MIN. WALLS AS OCCURS SHALL BE CONSTRUCTED OF 5/8" FIREBLOCK TYPE X GYPSUM BOARD. GENERAL NOTES: · ALL FIRE FATED WALLS SHOULD BE LABELED AND IDENTIFIED AS REQUIRED BY IBC 703.7 (ONLY IN ACCESSIBLE LOCATIONS AS DESCRIBED IN IBC 703.7) · FIRE BARRIERS, AS REQUIRED BY IBC 707.3, SHALL EXTEND FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB, OR DECK ABOVE AND SHALL BE SECURELY ATTACHED PER IBC 707.5 · FIRE BARRIERS SHALL BE CONTINUOUS THROUGH CONCEALED SPACES. · FIRE PARTITIONS, AS REQUIRED BY IBC 708.1, SHALL EXTEND FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB, OR DECK ABOVE OR TO THE FIRE-RESISTANCE RATED FLOOR/CEILING OR ROOF/CEILING ASSEMBLY ABOVE, AND SHALL BE SECURELY ATTACHED. · FLOOR AND ROOF ASSEMBLIES SHALL BE CONTINUOUS WITHOUT VERTICAL OPENINGS, EXCEPT AS PERMITTED BY 711 AND 712, PER IBC 711.2 ONE LAYER 5/8" PROPRIETARY TYPE X GYPSUM BOARD WALLBOARD APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF DOUBLE ROW OF 2 X 4 WOOD STUDS 24" O.C. ON SEPARATE PLATES WITH 1 1/4" DRYWALL SCREWS 8" O.C. NO MINIMUM AIRSPACE BETWEEN ROWS OF STUDS. JOINTS STAGGERED 16" ON OPPOSITE SIDES. SOUND TESTED WITH 1" AIR SPACE BETWEEN ROWS OF STUDS AND 3 1/2" GLASS FIBER INSULATION IN STUD CAVITY ON BOTH SIDES (LOAD-BEARING) 2 HR INTERIOR WALL. SEE DETAIL 1/F1.05 1/2" or 5/8" thick, 4'-0" wide, applied in two layers. Base layer attached horizontally to studs and side "J" runners with 1" long Type S self-tapping steel screws starting at 2" from the floor and ceiling runners and spaced a maximum 24" O.C along the vertical edges and in the field of the boards. Face layer applied vertically to studs and side "J" runners and attached with 1-5/8" long Type S self-tapping steel screws, starting at 3" from the floor and ceiling runners and spaced a maximum 12" O.C along the vertical edges and in the field of the boards. Face layer joints covered with paper tape and two coats of joint compound. Exposed screw heads covered with two coats of joint compound. AMERICAN GYPSUM CO — 1/2" OR 5/8" TYPE AG-C, 5/8" TYPE AGX-1 OR M-GLASS ASSEMBLY : UL V455 FIRE TEST : ANSI/UL 263 RATING : 2HR GYPSUM BOARD - GYPSUM LINER PANELS, NOM 1 IN. THICK, 24" WIDE. PANELS CUT MAX 1" LESS IN LENGTH THAN FLOOR TO CEILING HEIGHT. VERTICAL EDGES INSERTED IN "H" -SHAPED SECTION OF "C-H" STUDS. FREE EDGE OF END PANELS ATTACHED TO LONG LEG OF "J" -RUNNERS WITH 1-5/8" LONG TYPE S BUGLE HEAD STEEL SCREWS SPACED NOT GREATER THAN 12" O.C. (2) LAYERS 1/2" OR 5/8" GYPSUM BOARD STEEL STUDS - "C-H" -SHAPED STUDS, MIN 2-1/2" DEEP, 1-1/2" WIDE, FABRICATED FROM MIN 25 MSG GALV STEEL. CUT TO LENGTHS 5/8" LESS THAN FLOOR-TO-CEILING HEIGHT AND SPACED 24" 24" O.C. FLOOR, CEILING AND SIDE RUNNERS - FREE EDGE OF END PANELS ATTACHED TO LONG LEG OF "J" -RUNNERS WITH 1-5/8" LONG TYPE S BUGLE HEAD STEEL SCREWS SPACED NOT GREATER THAN 12" O.C. © 2016 UL LLC PLUMBING VENTS AND WASHER BOXES ARE NOT PERMITTED TO PENETRATE SHAFT WALLS SCALE: 1 F1.08 STAIRWELL/ELEVATOR INTERIOR WALL - 2HR 1 1/2" = 1'-0" SCALE: 2 F1.08 EXT. WALL - 1HR 1 1/2" = 1'-0" SCALE: 3 F1.08 CORRIDOR WALL - 1HR (STC 50-54) 1 1/2" = 1'-0" SCALE: 4 F1.08 FIRE RATED MECHANICAL SHAFT DETAIL 1 1/2" = 1'-0" SCALE: 5 F1.08 UNIT DEMISING WALL - 1HR 1 1/2" = 1'-0" SCALE: 7 F1.08 FLOOR/CEILING ASSEMBLY - 1HR (STC 60-64) 1 1/2" = 1'-0" SCALE: 13 F1.08 CORRIDOR SOFFIT DETAIL @ 2 HR 1 1/2" = 1'-0" SCALE: 10 F1.08 SHAFT WALL ASEMBLY - 2HR 1 1/2" = 1'-0" SCALE: 14 F1.08 2 HR WALL @ ROOF 1 1/2" = 1'-0" SCALE: 15 F1.08 TRASH CHUTE SHAFT 1/2" = 1'-0" SCALE: 16 F1.08 2 HR WALL @ FLOOR 1 1/2" = 1'-0" SCALE: 18 F1.08 NOT USED 1 1/2" = 1'-0" NOTE: GYPSUM WALLBOARD NOM 5/8 IN. THICK, 4 FT. WIDE, TWO LAYERS APPLIED VERTICALLY. BASE LAYER NAILED TO WOOD STUDS AND BEARING PLATES 6 IN. OC. WITH 6D CEMENT COATED NAILS, 1-7/8 IN. LONG, 0.0915 IN. SHANK DIAM. AND 1/4 IN. DIAM. HEAD. THE FACE LAYER, WITH JOINTS STAGGERED FROM BASE LAYER, NAILED TO THE STUDS AND BEARING PLATES OVER THE BASE LAYER, 8 IN. OC WITH 8D CEMENT COATED NAILS, 2-3/8 IN. LONG, 0.113 IN. SHANK DIAM. 9/32 IN. DIAM. HEAD OR INNER LAYER ATTACHED TO STUDS WITH 1-1/4 IN. LONG TYPE S STEEL SCREWS SPACED 12 IN. OC. OUTER LAYER ATTACHED TO STUDS OVER INNER LAYER WITH 2 IN. LONG TYPE S STEEL SCREWS SPACED 12 IN. OC OFFSET 6 IN. FROM BASE LAYER. JOINTS COVERED WITH TAPE AND JOINT COMPOUND. NAIL HEADS COVERED WITH JOINT COMPOUND. 1 BUILDING REVIEW COMMENTS ITEM #A6-A 9-20-16 SCALE: 11 F1.08 FLOOR/NON-BEARING WALL INTERSECTION 1 1/2" = 1'-0" FLOOR JOISTS PER STRUCTURAL RESILIENT CHANNEL (2) LAYERS 1/2" TYPE "X" DRYWALL CEILING TYP. SEE DETAILS 6-7/F1.08 CONTINUOUS 6" ACOUSTIC BATTING 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED). FIRE TAPE ALL GYP. BD. WALL JOINTS. 1 BUILDING REVIEW COMMENTS ITEM #A6-C 9-20-16 PENETRATIONS THROUGH DOUBLE TOP PLATE PROTECTED PER LISTED AND APPROVED THROUGH-PENETRATION FIRE ASSEMBLY. SEE FIRE PENETRATION DETAILS F1.09 DOUBLE TOP PLATE FIRE BLOCKING IS REQUIRED TO BE PROVIDED HORIZONTALLY EVERY 10' ALONG THE LENGTH OF THE WALL AND VERTICALLY AT THE FLOOR LEVEL 1 BUILDING REVIEW COMMENTS ITEM #A6-D 9-20-16 SCALE: 12 F1.08 FIRE BARRIER INTERIOR WALL - 1HR. 1 1/2" = 1'-0" FLOOR JOISTS PER STRUCTURAL RESILIENT CHANNEL (2) LAYERS 1/2" TYPE "X" DRYWALL CEILING TYP. SEE DETAILS 1-2/D1.03 CONTINUOUS 6" ACOUSTIC BATTING 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED). FIRE TAPE ALL GYP. BD. WALL JOINTS. 1 BUILDING REVIEW COMMENTS ITEMS #A6-B-I, #A6-B-II 9-20-16 FIRE BARRIER TO CONTINUE TO UNDERSIDE OF FLOOR SHEATHING ABOVE DOUBLE TOP PLATE FLOOR & ROOF ASSEMBLIES SHALL BE CONTINUOUS WITHOUT VERTICAL OPENINGS, EXCEPT AS PERMITTED BY 711 & 712, PER IBC 711.2 1 BUILDING REVIEW COMMENTS ITEM #A6-B-III 9-20-16 1 BUILDING REVIEW COMMENTS ITEMS #A20-B, #A25-B 9-22-16 1 BUILDING REVIEW COMMENTS ITEM #A6-B 9-23-16 SCALE: 17 F1.08 2 HR WALL @ FOUNDATION 1 1/2" = 1'-0" SCALE: 8 F1.08 FLOOR /CEILING ASSEMBLY - 2HR 1 1/2" = 1'-0" BASE LAYER: 5/8" TYPE X GYPSUM WALL BOARD APPLIED AT RIGHT ANGLES TO 9 1/2" DEEP WOOD I-JOISTS 24" O.C. WITH 1 1/4" TYPE W DRYWALL SCREWS 12" O.C. SECOND LAYER: 5/8" TYPE X GYPSUM WALL BOARD APPLIED AT RIGHT ANGLES TO I-JOISTS WITH 2'" TYPE W DRYWALL SCREWS 12" O.C. SECOND LAYER JOINTS OFFSET 24" FROM BASE LAYER JOINTS. THIRD LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO I-JOISTS WITH 2 1/2" TYPE W DRYWALL SCREWS 12" O.C. THIRD LAYER JOINTS OFFSET 12" FROM SECOND LAYER JOINTS. HAT-SHAPED 7/8" RIGID FURRING CHANNELS 24" O.C. APPLIED AT RIGHT ANGLES TO I-JOISTS OVER THIRD LAYER WITH TWO 2 1/2" LONG TYPE W DRYWALL SCREWS AT EACH I-JOIST. FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIES AT RIGHT ANGLES TO FURRING CHANNELS WITH 1 1/8" TYPE S DRYWALL SCREWS 12" O.C. WOOD I-JOISTS SUPPORTING 3/4" T & G EDGE PLYWOOD FLOOR APPLIED AT RIGHT ANGLES TO I-JOISTS WITH 8D NAILS 6" O.C. AT JOINTS AND 12" AT INTERMEDIATE I-JOISTS. CEILING PROVIDES TWO-HOUR FIRE-RESISTANCE PROTECTION FOR WOOD FRAMING. ASSEMBLY: GA FC 57501 FIRE TEST: UL R4024, 00NK26545, 4-27-01 UL DESIGN L556, ULC DESIGN M514 SOUND TEST: N/A RATING : 2HR FLOOR JOISTS PER STRUCTURAL DRAWINGS FLOOR SHEATHING PER STRUCTURAL DRAWINGS (3) LAYERS OF 5/8" TYPE "X" GYP. BOARD (TAPED, SANDED & PAINTED) EACH SIDE. FIRE TAPE ALL GYP. BOARD WALL JOINTS. 7/8" HAT-SHAPED RIGID FURRING CHANNELS 24" O.C. APPLIED AT RIGHT ANGLES TO I-JOISTS (1) LAYER OF 5/8" TYPE "X" GYP. BOARD (TAPED, SANDED & PAINTED) EACH SIDE. FIRE TAPE ALL GYP. BOARD WALL JOINTS. 1 BUILDING REVIEW COMMENTS ITEMS #A19-E, #A24-C 9-23-16 SCHEDULED WOOD SHEATHING PANEL. SEE STRUCTURAL DRAWINGS. STRUCTURAL ROOF JOISTS. SEE STRUCTURAL DRAWINGS. R-20 MIN. SPRAY FOAM INSULATION APPLIED TO UNDERSIDE OF ROOF SHEATHING. SPRAY FOAM TO BE A CLASS II VAPOR RETARDER. REMAINING CAVITY FILLED WITH BLOWN IN INSULATION (R-49 MIN. TOTAL ASSEMBLY) 1/2" RESILIENT CHANNELS @ 16" O.C. PROVIDE 1-1/2" (MIN.) WIDE HOT AIR WELD @ ALL LAP JOINTS (TYP.) (2) LAYERS OF 1/2" TYPE "X" GYP. BOARD (TAPED, SANDED & PAINTED) EACH SIDE. FIRE TAPE ALL GYP. BOARD WALL JOINTS. SCHEDULED 2X SLEEPERS. SEE STRUCTURAL DRAWINGS. RATED ASSEMBLY ASSEMBLY: GA FC 5111 FIRE TEST: NRCC A-4440.1 6-24-97 SOUND TEST: NRCC B-3150.2 6-30-00 RATING: 1HR BASE LAYER: 1 2 " TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO RESILIENT CHANNELS 16" O.C. WITH 1 1 4 " TYPE S DRYWALL SCREWS 12" O.C. RESILIENT CHANNELS APPLIED AT RIGHT ANGLES TO MINIMUM 9 1 2 " DEEP WOOD I-JOISTS, WITH MINIMUM 1 1 4 " DEEP X 1 1 2 " WIDE FLANGES AND MINIMUM 3 8 " WEBS, 24" O.C. WITH 1 1 4 " TYPE W DRYWALL SCREWS. FACE LAYER: 1 2 " TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGELS TO CHANNELS WITH 1 5 8 " TYPE S DRYWALL SCREWS 12" O.C. FACE LAYER END JOINTS LOCATED MIDWAY BETWEEN CHANNELS AND ATTACHED TO BASE LAYER WITH 1 1 2 " TYPE G SCREWS 12" O.C. EDGE JOINTS OFFSET 24" FROM BASE LAYER EDGE JOINTS. WOOD I-JOISTS SUPPORTING 5 8 " ORIENTED STRAND BOARD APPLIED A RIGHT ANGELS TO I-JOISTS WITH 8D COMMON NAILS 12" O.C. CLASS B SINGLE PLY ENERGY STAR CERTIFIED ROOF MEMBRANE. PROVIDE SUBSTRATE AS REQUIRED PER ROOFING MANUFACTURER FOR FULL WARRANTY, MIN. SLOPE 1/4" PER FOOT. 6 MIL BREATHABLE SMART MEMBRANE VAPOR BARRIER (CLASS II) FLOOR & ROOF ASSEMBLIES SHALL BE CONTINUOUS WITHOUT VERTICAL OPENINGS, EXCEPT AS PERMITTED BY 711 & 712, PER IBC 711.2 1 BUILDING REVIEW COMMENTS ITEM #A6-B-III 9-20-16 SCALE: 6 F1.08 ROOF CEILING ASSEMBLY - 1HR 1 1/2" = 1'-0" 1 BUILDING REVIEW COMMENTS ITEM #A7 9-28-16 1 BUILDING REVIEW COMMENTS #2 ITEM #A6-C 10-5-16 MECHANICAL AND PLUMBING CONDUIT. FIRE CAULK ALL PENETRATIONS. (2) LAYERS 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED). FIRE TAPE ALL GYP. BD. WALL JOINTS. 1" GYPCRETE OVER ACOUSTI-MAT 2 DOUBLE SILL PLATE 2x FLOOR JOIST, SEE STRUCTURAL 1 BUILDING REVIEW CMNTS RD 2 ITEMS #A3/C, A3/E 10/7/16 (2) LAYERS CONTINUOUS 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED) TERMINATING AT UNDERSIDE OF ROOF SHEATHING. FIRE TAPE ALL GYP. BD. WALL JOINTS. FIRE RATED SHEATHING MIN. 48" EITHER SIDE OF RATED WALL 48" MIN. 48" MIN. 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED). FIRE TAPE ALL GYP. BD. WALL JOINTS. DOUBLE TOP PLATE SCHEDULED WOOD SHEATHING PANEL, SEE STRUCTURAL DRAWINGS R-20 MIN. SPRAY FOAM INSULATION APPLIED TO UNDERSIDE OF ROOF SHEATHING. SPRAY FOAM TO BE A CLASS II VAPOR RETARDER. REMAINING CAVITY FILLED WITH BLOWN IN INSULATION (R-49 MIN. TOTAL ASSEMBLY) (2) LAYERS CONTINUOUS 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED) TERMINATING AT UNDERSIDE OF FLOOR SHEATHING. FIRE TAPE ALL GYP. BD. WALL JOINTS. 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED). FIRE TAPE ALL GYP. BD. WALL JOINTS. FLOOR JOISTS PER STRUCTURAL CONTINUOUS 6" ACOUSTIC BATTING (2) LAYERS 1/2" TYPE "X" DRYWALL CEILING TYP. SEE DETAILS 6-7/F1.08 1" GYPCRETE OVER ACOUSTI-MAT 2 2X12 BLOCKING RESILIENT CHANNEL (2) LAYERS CONTINUOUS 5/8" TYPE "X" GYP. BD. (TAPED, SANDED & PAINTED) TERMINATING AT UNDERSIDE OF FLOOR SHEATHING. FIRE TAPE ALL GYP. BD. WALL JOINTS. CONC. SLAB SEE STRUCTURAL DRAWINGS 1 BUILDING REVIEW CMNTS RD 2 ITEMS #A3/C, A3/E 10/7/16 1 BUILDING REVIEW CMNTS RD 2 ITEMS #A3/C, A3/E 10/7/16 1 BUILDING REVIEW CMNTS RD 2 ITEMS #A3/C, A3/E 10/7/16 1 BUILDING REVIEW CMNTS RD 2 ITEMS #A3/C, A3/E 10/7/16 CALCULATED FIRE RATING: WOOD STUDS AT 16" O.C.- 20MIN. IBC 722.6.2(2) 5 8 " TYPE X GYP. BOARD- 40MIN. IBC 722.2.1.4(2) TOTAL- 60MIN. SCALE: 9 F1.08 TYPICAL 1HR WRAPPED STRUCTURAL COLUMN 3" = 1'-0" (1) LAYER GYP. BOARD SEE DETAIL 2/F1.08 FOR TYPE. H.S.S. STEEL COLUMN. SEE STRUCTURAL FOR SIZE AND TYPE. (1) LAYER GYP. BOARD PLACED BETWEEN COLUMN AND FRAMING TO ENCASE COLUMN. SEE DETAIL 2/F1.08 FOR TYPE. 2X STUD FRAMING STRUCTURAL WOOD COLUMN. SEE STRUCTURAL DRAWINGS FOR SIZE AND TYPE. 2X STUD FRAMING (1) LAYER GYP. BOARD SEE DETAIL 2/F1.08 FOR TYPE. STEEL COLUMN WOOD COLUMN & BEARING WALL 2X6 WALL PER PLANS. PROVIDE HORIZONTAL BLOCKING TO ATTACH C/H CLIPS PER MANUFACTURER SPECS. (1) LAYER 1"X24" TYPE "X" GYP. PANEL AROUND INSIDE OF SHAFT PER GA WP 7051 (2) LAYERS 1/2" TYPE "X" GYP. BOARD AROUND SHAFT PER GA WP 7051 ASSEMBLY: GA WP 7051 FIRE TEST: UL R7094, 93NK8151, 9-14-93; UL R3660, 07NK22992, 2-18-08; UL DESIGN U428 RATING: 2HR ONE LAYER 1"X24" PROPRIETARY TYPE X GYPSUM PANELS INSERTED BETWEEN 2-1/2" FLOOR AND CEILING J RUNNERS WITH T SECTION OF 2-1/2" STEEL C-H OR C-T STUDS BETWEEN PANELS. OPPOSITE SIDE: BASE LAYER 1 2 " PROPRIETARY TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO STUDS WITH 1" TYPE S DRYWALL SCREWS 24" O.C. FACE LAYER 1 2 " PROPRIETARY TYPE X GYPSUM WALLBOARD APPLIED PARALLEL TO STUDS WITH 1-5/8" TYPE S DRYWALL SCREWS 12" O.C. PROPRIETARY GYPSUM COMPONENTS CERTAINTEED GYPSUM INC. - 1 2 " CERTAINTEED TYPE C GYPSUM BOARD 1" GLASROC SHAFTLINER PANELS CONTINENTAL BUILDING PRODUCTS - 1 2 " FIRECHECK TYPE C - 1" MOLD DEFENSE SHAFTLINER GEORGIA-PACIFIC GYPSUM LLC - 1 2 " TOUGHROCK FIREGUARD C GYPSUM BOARD - 1" TOUGHROCK SHAFTLINER NATIONAL GYPSUM COMPANY - 1 2 " GOLD BOND BRAND FIRE-SHIELD C GYPSUM BOARD - 1" GOLD BOND BRAND FIRE-SHIELD SHAFTLINER PABCO GYPSUM - 1 2 " FLAME CURB SUPER 'C' TYPE PG-C - 1" PABCORE GYPSUM LINER BOARD Sheet Number Sheet Title CIVIL ENGINEER STRUCTURAL ENGINEER MECHANICAL ENGINEER ELECTRICAL ENGINEER Architecture Belgique, Inc. Phone: 801.561.1333 residential commercial Contact: Guillaume Belgique Email: [email protected] T H E S E P L A N S A R E I N S T R U M E NT S O F P R O F ES S IO N A L S E R V IC E , A R E T H E I N T EL L E C T U A L P R O P E R T Y O F A R C HI T E C T U R E B E L G I Q U E , I N C ., A ND A R E P R O T E C T E D B Y C O M M O N L A W , S T A T U T O R Y A N D O T H E R R E S E R V E D R I G H T S I N C L U D IN G , B UT N O T L I M I T E D T O , C O P Y R I G H T . T H E Y M A Y N O T B E R E P R O D U C E D O R U S E D F O R A N Y P U R P O S E W I T H O U T T H E W R I T T E N C O NS E N T O F A R C HI T E C T U R E B E L G IQ U E , I N C . NORTH TEMPLE & ORANGE Contact: Dany Tremblay PHONE: (801) 486-6848 Canyons Structural Consulting Contact: Jason Barker PHONE: (801) 352-0075 Focus Engineering & Surveying PVE Contact: Justin Gibbs PHONE: (801) 359-3158 Contact: Severin Mcjunkin PVE PHONE: (801) 359-3158 EMAIL: [email protected] INTERIOR DESIGNER Contact: Rachel Sowieja Vida-Design PHONE: (503) 208-2530 LANDSCAPE ARCHITECT Contact: Scott Blake STB Design PHONE: (801) 554-6146 07/27/2015 Date REVISIONS July 27, 2016 DATE 30 NORTH ORANGE STREET Salt Lake City, Utah # 1 2 3 4 5 6 7 8 9 10 11 12 9/28/16 CITY REVIEW COMMENTS FIRE DETAILS F1.08 11/01/16