GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The GAT NET.Controller M 7000 (master controller) and S 7000 (slave controller) control units are used to connect and control the GAT NET. Lock 7000 electronic locker locks from GANTNER. The control units operate in online mode and communicate with a host PC/server. The GAT NET.Controller M 7000 master controller serves as the communication bridge between the host PC/server and the GAT NET. Controller S 7000 slave controllers. For system flexibility, different slave controllers are available to suit the leading RFID technologies (see order information). Functional description The correct type of slave controller must be used to suit the RFID technology in operation. The slave controllers are connected to the master controllers via a serial RS 485 interface. Each master controller can control up to 8 slave controllers and 192 locks over a maximum cable length of 200 m. For smaller MIFARE ® /ISO systems, a light version of the slave and master controllers is available (see functionality table). In online operation, the slave controllers receive data carrier information via the connected locks. This information is sent via the master controller to the PC/server for authorization. The current status of the locker system is also forwarded to the PC/server, thereby allowing the status of each locker to be visualized using, for example, GANTNER PC software. An emergency mode function for online mode ensures operation continues if communication to the PC/server is temporarily interrupted. Highlights • Connection of locks via industry-standard MOLEX plugs • LED status display • Simple configuration with GANTNER software tools • Firmware update via host interface possible • Diagnostic system for detecting lock problems • Integration into alarm system (locker break-in alarm) Accessories Description Part No. GAT NET.Controller M 7000 Master controller for max. 8 GAT NET.Controller S 7000 slave controllers 253224 GAT NET.Controller M 7000 Light Master controller for max. 3 GAT NET.Controller S 7000 slave controllers, no relays and no optocouplers 978541 GAT NET.Controller M 7000 Light ext. GAT NET.Controller M 7000 Light extension license for max. 8 GAT NET.Controller S 7000 slave controllers 978440 GAT NET.Controller S 7000 F/ISO MIFARE ® /ISO 15693 slave control unit for max. 24 GAT NET.Lock 7000 electronic locks 253426 GAT NET.Controller S 7000 F/ISO Light MIFARE ® /ISO 15693 slave control unit for max. 12 GAT NET.Lock 7000 electronic locks 429730 GAT NET.Controller S 7000 B LEGIC ® slave controller for max. 24 GAT NET.Lock 7000 253325 GAT NET.Controller S 7000 ICLS iCLASS ® slave control unit for max. 24 GAT NET.Lock 7000 768538 1 www.gantner.com Description Part No. GAT NET.Lock 7000 Electronic locker lock 368534 GAT NET.Lock Cable 5m 5 m connection cable for the GAT NET.Lock 7000, 4-pin MOLEX plug on both ends 734430 GAT NET.Lock Cable Extension 3m 3 m extension cable for the GAT NET.Lock 7000 810021 GAT NET.Power Supply 230V Power supply unit 369434 GAT NET.Power Cord xxx Power cord for power supply unit. 494181 (EU), 494282 (UK), 511474 (AUS), 636835 (US), 636734 (IND) See description GAT NET.Power Plug Plug to forward the power supply 370426 GAT Patch Kabel 5805 5 m, shielded Ethernet patch cable with 8-pin RJ45 plugs 909321 Valid from September 15 th 2015 • Technical data subject to modification without notice! DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835 GAT NET.Controller M 7000 GAT NET.Controller S 7000 Order information Master Standard Master Light Slave Standard Slave Light Number of relays 4 0 - - Number of optocouplers 4 0 - - Max. no. of slave units 8 3* - - Max. no. of NET.Locks 192 (via slaves) 36 (via slaves) 24 12 Controller functionality table (F/ISO) *expandable to 8 with additional license (Part No. 978440)
5
Embed
GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 · GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The GAT NET.Controller M 7000 (master
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
GAT NET.Controller 7000Control unit for the GAT NET.Lock 7000
ApplicationThe GAT NET.Controller M 7000 (master controller) and S 7000 (slave
controller) control units are used to connect and control the GAT NET.
Lock 7000 electronic locker locks from GANTNER.
The control units operate in online mode and communicate with a host
PC/server. The GAT NET.Controller M 7000 master controller serves as
the communication bridge between the host PC/server and the GAT NET.
Controller S 7000 slave controllers.
For system flexibility, different slave controllers are available to suit the
leading RFID technologies (see order information).
Functional descriptionThe correct type of slave controller must be used to suit the RFID technology
in operation. The slave controllers are connected to the master controllers
via a serial RS 485 interface. Each master controller can control up to 8
slave controllers and 192 locks over a maximum cable length of 200 m.
For smaller MIFARE®/ISO systems, a light version of the slave and master
controllers is available (see functionality table).
In online operation, the slave controllers receive data carrier information
via the connected locks. This information is sent via the master controller
to the PC/server for authorization. The current status of the locker system
is also forwarded to the PC/server, thereby allowing the status of each
locker to be visualized using, for example, GANTNER PC software. An
emergency mode function for online mode ensures operation continues if
communication to the PC/server is temporarily interrupted.
Highlights• Connection of locks via industry-standard MOLEX plugs
• LED status display
• Simple configuration with GANTNER software tools
• Firmware update via host interface possible
• Diagnostic system for detecting lock problems
• Integration into alarm system (locker break-in alarm)
Accessories
Description Part No.
GAT NET.Controller M 7000Master controller for max. 8 GAT NET.Controller S 7000 slave controllers
253224
GAT NET.Controller M 7000 LightMaster controller for max. 3 GAT NET.Controller S 7000 slave controllers, no relays and no optocouplers
978541
GAT NET.Controller M 7000 Light ext.GAT NET.Controller M 7000 Light extension license for max. 8 GAT NET.Controller S 7000 slave controllers
978440
GAT NET.Controller S 7000 F/ISOMIFARE®/ISO 15693 slave control unit for max. 24 GAT NET.Lock 7000 electronic locks
253426
GAT NET.Controller S 7000 F/ISO LightMIFARE®/ISO 15693 slave control unit for max. 12 GAT NET.Lock 7000 electronic locks
429730
GAT NET.Controller S 7000 BLEGIC® slave controller for max. 24 GAT NET.Lock 7000
253325
GAT NET.Controller S 7000 ICLSiCLASS® slave control unit for max. 24 GAT NET.Lock 7000
768538
1www.gantner.com
Description Part No.
GAT NET.Lock 7000Electronic locker lock
368534
GAT NET.Lock Cable 5m
5 m connection cable for the GAT NET.Lock 7000, 4-pin
MOLEX plug on both ends
734430
GAT NET.Lock Cable Extension 3m
3 m extension cable for the GAT NET.Lock 7000
810021
GAT NET.Power Supply 230VPower supply unit
369434
GAT NET.Power Cord xxx
Power cord for power supply unit. 494181 (EU), 494282
(UK), 511474 (AUS), 636835 (US), 636734 (IND)
See
description
GAT NET.Power PlugPlug to forward the power supply
370426
GAT Patch Kabel 58055 m, shielded Ethernet patch cable with 8-pin RJ45 plugs
909321
Valid from September 15th 2015 • Technical data subject to modification without notice! DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835
GAT NET.Controller M 7000
GAT NET.Controller S 7000
Order information
Master Standard
Master Light
SlaveStandard
SlaveLight
Number of relays
4 0 - -
Number of optocouplers
4 0 - -
Max. no. of slave units
8 3* - -
Max. no. of NET.Locks
192(via slaves)
36(via slaves)
24 12
Controller functionality table (F/ISO)
*expandable to 8 with additional license (Part No. 978440)
Nominal voltage UDC: 24 V
Power supply unit: External power supply units available (see order information)
Reader types of slave control lers - GAT NET.Controller S 7000 F/ISO: - GAT NET.Controller S 7000 B: - GAT NET.Controller S 7000 ICLS:
MIFARE® + ISO 15693LEGIC® (Advant)HID iCLASS®
Maximum locks per slave controller:
- Slave standard: 24- Slave light: 12
Maximum slave controllers per master controller:
- Master standard: 8- Master light: 3*
Memory (Master): Internal memory for 10,000 bookingsSD card slot for memory expansion, log files, firmware update or user lists
Note: The GAT NET.Controller S 7000 F/ISO Light has 12 lock connection ports
RS 485IN
RESE
T
MO
DE
LED
1
LED
2
RS 485OUT
Power
To the next GAT NET.Controller S 7000
Power supply GAT NET.Power Supply(or power plug - see description below)
From master controller or fromprevious GAT NET.Controller S 7000
GAT NET.Controller S 7000
RS 485IN
RESE
T
MO
DE
LED
1
LED
2
RS 485OUT
Power
RS 485IN
yellow green
RESE
T
MO
DE
LED
1
LED
2
RS 485OUT
Power
OUT
IN
OUT
IN
RS 485
RS 485
From master controller
Supply
Supply
OUT
INGAT NET.Controller S 7000
PowerPlug
4 www.gantner.comValid from September 15th 2015 • Technical data subject to modification without notice! DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835
Electrical connections - GAT NET.Controller M 7000
Ethernet connection (to host)
Network connections
- Ethernet to host via RJ 45 jacks.
- RS 485 bus connection to slave controllers via RJ 45 jacks.
- 200 m max. cable length per RS 485 line.
The GAT NET.Controller S 7000 must be connected to the
“RS 485 SLAVES“ socket!
Recommended cabling
Ethernet: min. CAT 5 (STP)
RS 485: min. CAT 5 (STP), 200 m max. cable length per RS 485 line.
LED signaling
- RS 485 IN (yellow): Connection to the slave controller
- RS 485 IN (green): RS 485 communication active
- LED 1 (blue): For future use
- LED 2 (green/red): Status information (see manual)
Reset and mode buttons
- RESET: 1. Reset of controller (see manual)
2. Delete configuration = reset to default (see manual)
- MODE: Reserved for future use
Power supply
Power is connected to the MOLEX
socket labeled “Power“. Use the supplied
power supply unit (see technical data).
Note: For a tidy installation, the power supply can be stored in the
designated slot in the bottom of the controller housing.
GAT NET.Controller M 7000
Ethernet to host
Note: The GAT.NET Controller M 7000 F/ISO Light does not have any relays or optocouplers
RS 485SLAVES
RESE
T
MO
DE
LED
1
LED
2
RS 485ADD-ON
Power
To the first GAT NET.Controller S 7000
Power supply GAT NET.Power Supply(or power plug - see description below)
GAT NET.Controller M 7000
Power and slave controller connections
RS 485SLAVES
yellow green
RESE
T
MO
DE
LED
1
LED
2
RS 485ADD-ON
Power
RS 485IN
RESE
T
MO
DE
LED
1
LED
2
RS 485OUT
Power
Safety instructions
- This device must be installed by qualified personnel only.
- The applicable safety and accident prevention regulations
must be observed.
- Safety devices must not be removed.
- Please observe the technical data of the device specified
on the data sheet.
- The device must be disconnected from the power supply
prior to installation, assembly or dismantling.
The WEEE symbol on GANTNER products and their packaging
indicates that the corresponding material must not be disposed
of with normal household waste. Instead such marked waste
equipment must be disposed of by handing it over to a designated
electronic waste recycling facility. Separating and recycling this
waste equipment at the time of disposal will help to conserve
natural resources and ensure that it is recycled in a manner that
protects human health and the environment. Please contact your
local authority for further details of your nearest electronic waste
recycling facility.
5www.gantner.comValid from September 15th 2015 • Technical data subject to modification without notice!
DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835