GET MORE RELIABLE PERFORMANCE THAN YOU’RE GETTING FROM YOUR OEM IGNITERS. Whatever type of gas turbine you have—from microturbines to large-frame utility turbines—upgrading the performance and reliability of your ignition system is easy. Simply replace the OEM ignition system with a High Energy Ignition (HEI) System from Chentronics. Our High Energy Ignition System delivers unparalleled reliability and repeatability for all gas turbine applications including dual- fuel and on-demand (peaking) plants. In addition, it features fully integrated predictive diagnostics that alert you prior to an ignition fault occurring so you can replace the igniter tip before that happens. With a Chentronics HEI System, you can avoid missed starts and costly downtime. AT A GLANCE. Our High Energy Ignition System is packed with features for unbeatable performance in gas turbines. • Built-in predictive life diagnostics • Unsurpassed fuel-type diversity • Sparks-per-second (SPS) optimized for different fuels • Pressure seal of igniter tips and cables • Hazardous area rating • AC and DC input power options • ETL listed, complies with CE, UL, CSA, options for ATEX • Solid-state technology Gas Turbine Ignition Systems DUAL-FUEL RELIABILITY Chentronics HEI Systems have been proven in thousands of gas turbines worldwide—many of them dual-fuel. This extensive field experience, coupled with years of ignition research and development, offers us a unique insight into the challenges of lighting multiple fuel types. As a result, our HEI Systems are calibrated to the exact number of sparks-per-second required for dual-fuel lighting, so you get reliable ignition without having to change a single setting. When it comes to ignition on your gas turbines, a Chentronics HEI System lights better and costs less. Call us today. I G N I T I N G I N N O V A T I O N Chentronics HEI System
2

Gas Turbine Ignition Systems - Chentronics · 2019. 10. 4. · the OEM ignition system with a High Energy Ignition (HEI) System from Chentronics. Our High Energy Ignition System delivers

Aug 23, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Gas Turbine Ignition Systems - Chentronics · 2019. 10. 4. · the OEM ignition system with a High Energy Ignition (HEI) System from Chentronics. Our High Energy Ignition System delivers

GET MORE RELIABLE PERFORMANCE THAN YOU’RE GETTING FROM YOUR OEM IGNITERS.Whatever type of gas turbine you have—from microturbines

to large-frame utility turbines—upgrading the performance

and reliability of your ignition system is easy. Simply replace

the OEM ignition system with a High Energy Ignition (HEI)

System from Chentronics.

Our High Energy Ignition System delivers unparalleled reliability

and repeatability for all gas turbine applications including dual-

fuel and on-demand (peaking) plants. In addition, it features

fully integrated predictive diagnostics that alert you prior

to an ignition fault occurring so you can replace the igniter tip

before that happens. With a Chentronics HEI System, you can

avoid missed starts and costly downtime.

AT A GLANCE.Our High Energy Ignition System is packed with features for

unbeatable performance in gas turbines.

• Built-in predictive life diagnostics

• Unsurpassed fuel-type diversity

• Sparks-per-second (SPS) optimized for different fuels

• Pressure seal of igniter tips and cables

• Hazardous area rating

• AC and DC input power options

• ETL listed, complies with CE, UL, CSA, options for ATEX

• Solid-state technology

Gas Turbine Ignition Systems

DUAL-FUEL RELIABILITY

Chentronics HEI Systems have been proven in

thousands of gas turbines worldwide—many of

them dual-fuel. This extensive field experience,

coupled with years of ignition research and

development, offers us a unique insight into the

challenges of lighting multiple fuel types. As a

result, our HEI Systems are calibrated to the

exact number of sparks-per-second required

for dual-fuel lighting, so you get reliable ignition

without having to change a single setting.When it comes to ignition on your gas turbines, a Chentronics HEI System lights better and costs less. Call us today.

I G N I T I N G I N N O V A T I O N

Chentronics HEI System

Page 2: Gas Turbine Ignition Systems - Chentronics · 2019. 10. 4. · the OEM ignition system with a High Energy Ignition (HEI) System from Chentronics. Our High Energy Ignition System delivers

U T I L I T I E S | I N D U S T R I A L | P E T R O C H E M I C A L | M A R I N E | G A S T U R B I N E S | B U R N E R S | P I L O T S | F L A R E S

© 2018 Chentronics, LLC. chentronics.com/legal-notices CHEN-18-72192

The best way to maintain ignition reliability for your gas turbines is to

know when ignition faults are going to occur so you can replace the

igniter tip before that happens. Chentronics ignition solutions include

fully integrated predictive diagnostics so you can do just that.

CHENTRONICS.COM 607-334-5531 / [email protected]

50O'Hara DriveNorwich, NY 13815 USA

Chenango County, NY

HARDWARE SPECIFICATIONS.*

Igniter tips

System Model: LO-4

Suitable Fuels: Gas, light oils, bio diesel

Diagnostics: Built-in predictive life diagnostics

Moisture Protection: Moisture seal available

Solid State Electronics: Internal electronics are rated Class 1, Division 2

System Input Power: 100-240 VAC 50/60 Hz

Stored Energy (Joules): 12

Spark Rate (nominal SPS): 4

Typical Exciter Size: 11 x 7 x 7 in. (279.4 x 177.8 x 177.8 mm)

Igniter Temperature Rating: Up to 1,832°F (1,000°C)

Exciter Temperature Range: -13 to 167°F (-25 to 75°C)

Available with a single- or dual-output exciter and a variety of igniter tips.* Specifications subject to change at any time.

Dual-output exciter

Single-output exciter