Version Number: SURE950000 REV.D Factory Address: No. 12 Outer Ring Industrial Park, Zhong Bei Industrial Park (Northern Area), Xiqing District, Tianjin, China Room 502, Gate1, Building B6, HaiTaiFaZhanWuDao, HaiTai Innovation Base, Xiqing District, Tianjin, China Telephone: +86-22-23732936/27984345. Ext: 8043/8401 Email:[email protected] Office Address: Tianjin Sure Instrument Science & Technology Co., Ltd Website: www.suremeter.com Subject to change without notice All Rights Reserved by Tianjin Sure Instrument www.suremeter.com Operation Manual Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter
23

Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

Jan 05, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

VersionNumber:SURE950000REV.D

FactoryAddress:No.12OuterRingIndustrialPark,ZhongBeiIndustrialPark

(NorthernArea),XiqingDistrict,Tianjin,China

Room502,Gate1,BuildingB6,HaiTaiFaZhanWuDao,HaiTai

InnovationBase,XiqingDistrict,Tianjin,China

Telephone:+86-22-23732936/27984345.Ext:8043/8401

Email:[email protected]

OfficeAddress:

TianjinSureInstrumentScience&TechnologyCo.,Ltd

Website:www.suremeter.comSubjecttochangewithoutnoticeAllRightsReservedbyTianjinSureInstrument

www.suremeter.com

OperationManual

Gas Turbine Flow Meter Model: LWQ

GasTurbineFlowMeter

Page 2: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

21

Table of Contents Table of Contents

1.GeneralInformation

1.1ProductDescription

2.TechnicalData

3.ModelandSelection

3.1ModelSelectionTable

3.2ConverterFunctionTable

4.CautionsforInstallation

4.1MountingPositons

4.2RequiredLengthsofRuns

4.3Connections

5.ElectricalWiring

3

4

5

11

11

12

13

13

13

15

18

...........................................................................................................

............................................................................................................

...................................................................................................................

............................................................................................................

.........................................................................................................

......................................................................................................

....................................................................................................

..............................................................................................................

.....................................................................................................

........................................................................................................................

...................................................................................................................

5.2LWQ-A:Twowiring4~20mAOutput,NoLocalDisplay 18............................................................

5.3LWQ-E;LWQ-H:LocalDisplay 19................................................................................................

5.1LWQ-N:PulseOutput,ExplosionProofModel 18........................................................................

23

25

25

25

26

33

38

41

42

33

23

246.ProgrammingandSetup

6.1LWQ-N:NoDisplay;PulseOutput

6.2LWQ-A:NoDisplay;4~20mAOutput

6.3LWQ-E;LWQ-H:LocalDisplay

6.4.1LWQ-D12wire4-20mA

6.4.2LWQ-D23wire4-20mA

7.Troubleshooting

8.LimitedWarrantyPolicy

....................................................................................................

.........................................................................................

..............................................................................................

....................................................................................

.............................................................................................

................................................................................................................

..............................................................................................

.......................................................................................................

5.4LWQ-D:LocalDisplay ........................................................................................................

6.4.1LWQ-DwithTemperatureandPressureCompensation ..........................................................

5.4.1LWQ-D1 .....................................................................................................................

5.4.2LWQ-D2 ....................................................................................................................

Page 3: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

3.Whenhandlinghazardousgases,alwaysfollowthe

4.Whenworkinginhazardousenvironments,always

exerciseappropriatesafetyprecautions.

43 43

1.GENERALINFORMATION

Thismanualwillassistyouininstalling,usingandmaintainingtheflowmeter.Itisyourresponsibilityto

procedure.

Warning

makesurethatalloperatorshaveaccesstoadequateinstructionsaboutsafeoperatingandmaintenance

1.1ProductDescription

Foryoursafety,reviewthemajorwarningsandcautionsbelowbeforeoperatingyourequipment.

only compatible1.Use fluidsthatare withthehousing

materialandwettedcomponentsofyourturbine.

2.Whenmeasuringflammablegases, observe

precautionsagainstfireorexplosion.

manufacturer'ssafetyprecautions.

8.Forbestresults,calibratethemeteratleast1time

peryear.

GasTurbineFlowMeterOperationManual OperationManual

5.Duringturbineremoval,gasmayspill.Followthegas

manufacturer'ssafetyprecautionsforcleanupof

minorspills.

6.Donotblowcompressedairthroughtheturbine.

7.Handletherotorcarefully.Evensmallscratchesor

nickscanaffectaccuracy.

Gasflowsthroughtheturbinehousingcausinganinternalrotortospin.Astherotorspins,anelectricalsignal

isgeneratedinthepickupcoil.Thissignalisconvertedintoengineeringunits(liters,cubicmeters,gallonsetc.)

onthelocaldisplaywhereisapplicable.Optionalaccessorymodulescanbeusedtoexportthesignaltoother

equipment.

Uponreceipt,examineyourmeterforvisibledamage.Theturbineisaprecisionmeasuringinstrumentand

shouldbehandledcarefully.Removetheprotectiveplugsandcapsforathoroughinspection.Ifanyitemsare

damagedormissing,contactus.

Makesuretheturbineflowmodelmeetsyourspecificneeds.Foryourfuturereference,itmightbeusefultorecord

thisinformationonnameplateinthemanualincaseitbecomesunreadableontheturbine.Refertothenameplate

foryourcustomizedproduct'sspecification.

GasTurbineFlowMeter

Page 4: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

2.TechnicalData

Measuringsystem&Measuringaccuracy

65

OperationManual OperationManual

Applicationrange

Gas:NaturalGas,LPG,Air

(1)Drygaswithoutwater

(2)Gaswithoutcorrosion

MeasuredValue

Primarymeasuredvalue FlowRate

Secondarymeasuredvalue Volumeflow

TertiarymeasuredvalueTemperature;Pressure

(ONLYavailableforcompensationmodel)

Features

ModularconstructionThemeasurementsystemconsistsofaflowsensorandasignalconverter.Itisavailableascompactandasseparateversion.

Compactversionconverter

NType:Pulseoutputwithoutdisplay

AType:4-20mAOutputwithoutlocaldisplay

E1Type:LocalDisplay;LithiumBatteryPower;NoOutput

E2Type:LocalDisplay;24VDC/BatteryPower;2wire4-20mAOutput;

E3Type:LocalDisplay;24VDC/BatteryPower;Pulseoutput

E4Type:LocalDisplay;24VDC/BatteryPower;3wire0-20mAoutput

E5Type:LocalDisplay;24VDC/BatteryPower;3wire4-20mAoutput

HType:LocalDisplay;24VDCPower;Hart

CompensationType

D1:LocalDisplay;24VDCPower;DualPower:Battery;

4-20mA(2-wire);T&PCompensation;RS485

D2:LocalDisplay:24VDCPower;DualPower:Battery;

4-20mA(3-wire);T&PCompensation;ModbusRS485

MeasurementRatio Standard:10:1Optional:20:1

Referenceconditions

FlowconditionssimilartoISO9951

Medium:Gas

Temperature:+10...+30°C/+50...+86°F

Inletsection:≥10DN

Operatingpressure:1bar/14.5psig

FlowMeterAccuracyStandard:1.5% Qminto0.2Qmax:3%;0.2QmaxtoQmax:1.5%

Optional:1.0% Qminto0.2Qmax:2%;0.2QmaxtoQmax:1.0%

GasTurbineFlowMeterOperationManual OperationManual

GasTurbineFlowMeter

Page 5: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

Installationconditions

Materials

87

OperationManual OperationManual

InstallationTakecarethatflowsensorisalwaysfullyfilled

Fordetailedinformationseechapter"CautionsforInstallation"

FlowdirectionForward

Arrowonflowsensorindicatesflowdirection.

Inletrun ≥ 10DN

Outletrun ≥ 5DN

Temperature

Processtemperature -20...+80°C

Ambienttemperature Standard(withaluminumconverterhousing):

(allversions) -10…+55°C

Storagetemperature -20...+70°

Pressure

EN1092-1DN25…DN300:PN16

Otherpressuresonrequest

ASMEB16.51”...12":150lbRF

Otherpressuresonrequest

JIS1”...12":10K

Otherpressuresonrequest

Operatingconditions

SensorhousingSS304

Othermaterialsonrequest

FlangesSS304

Othermaterialsonrequest

RotorABSPlastic(Acrylonitrile-Butadiene–Styrene)

AluminumAlloy

BearingsandShaft SS304

ConverterHousing Standard:polyurethanecoateddie-castaluminum

GasTurbineFlowMeterOperationManual OperationManual

GasTurbineFlowMeter

Page 6: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

Connections Measurableflowraterange:

Note:Theflowrangeasblowisforreferenceonly.Consultthefactoryifyouhavespecialrequirement.Refertothenameplateorcertificateforactualflowrange.

9 10

OperationManual OperationManual

Flange

EN1092-1

DN25...80inPN16…40

DN100…150inPN16…25

DN200…300inPN16

ASME 1”…3"in150…300lbRF

4”…12”in150lbRF

JIS 1”…3”in10...20K

4”…12”in10K

Designofgasketsurface RF

Othersizesorpressureratingsonrequest

Thread DN25…DN50inPN16

NominalDiameter StandardFlowRange(SFR) ExtendedFlowRange(EFR)Standard

PressureRating

(mm) (in.) Code 3(m /h) Code 3(m /h) (Mpa)

25 1" S 2.5to25 W 4to40

1.6

40 1.5" S 5to50 W 6to60

50 2"S1 6to65 W1 5to70

S2 10to100 W2 8to100

65 2.5" S 15to200 W 10to200

80 3"S1 13to250

W 10to160S2 20to400

100 4"S1 20to400

W 13to250S2 32to650

125 5" S 25to700 W 20to800

150 6"S1 32to650

W 80to1600S2 50to1000

200 8"S1 80to1600

W 50to1000S2 130to2500

250 10"S1 130to2500

W 80to1600S2 200to4000

300 12" S 200to4000 W 320to6500

400 16" S 400to8000 W 260to8000

GasTurbineFlowMeterOperationManual OperationManual

GasTurbineFlowMeter

Page 7: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

11 12

OperationManual OperationManual

3.M

odela

ndSelectio

n

3.1ModelS

electio

nTable

GasTurbineFlowMeterOperationManual OperationManual

GasTurbineFlowMeter

3.2ConverterFunctionTable

Descriptionofthesymbols:DefaultFunction;Optional SUREProtocol

ConverterMode

PowerSupply

Display

OutputType

ModbusRs485

Hart24VDC Battery Pulse

Scaled Pulse

Current

2wire 3-wire 3-wire

4-20mA 4-20mA 0-20mA

N

A

E1

E2

E3

E4

E5

H

D1

D2

Page 8: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

13 14

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

Warning:Precautionfordirectsunshineandrainwhenthemeterisinstalledoutside.

4.2RequiredLengthsofStraightRuns

Flowalteringdevicesuchaselbows,valvesandreducerscanaffectaccuracy.Seediagrambelowfortypicalflowmeter

systeminstallation.

4.CAUTIONSFORINSTALLATION

4.1MountingPositions

Installthemeterwithenoughroomforfutureaccessformaintenancepurposes★

Avoidlocationsnearequipmentproducingelectricalinterferencesuchaselectricmotors,transformers,

variablefrequency,etc.★

Avoidallpipelocationswheretheflowispulsating,suchasintheoutletsideofpistonordiaphragmpumps.★

Diagram1.TypicalFlowMeterSystemInstallation

Therecommendedguidelinesaregiventoenhanceaccuracyandmaximizeperformance.Distancegivenhere

areminimumrequirements;doublethemfordesiredstraightpipelengths.

Upstream:allowaminimumstraightpipelengthatleast10timestheinternaldiameterofthepipe.For

example,withthe50mmpipe,thereshouldbe500mmofstraightpipeimmediatelyupstream.Desired

upstreamstraightpipelengthis1000mm.

★ Downstream:allowaminimumstraightpipelengthatleast5timestheinternaldiameterofthepipe.

Forexample,withthe50mmpipe,thereshouldbe250mmofstraightpipeimmediatelyupstream.

Desiredupstreamstraightpipelengthis500mm.

★ Foreignmaterialintheliquidbeingmeasuredcanclogthemeter'srotorandadverselyaffectaccuracy.

Ifthisproblemisanticipatedorexperienced,installscreenstofilterimpuritiesfromincomingliquids.

★ Toensureaccuratemeasurement,drainallairfromthesystembeforeuse.

Whenthemetercontainsremovablecoverplates.Leavethecoverplateinstalledunlessaccessorymodules

specifyremoval.Don'tremovethecoverplateswhenthemeterispowered,orelectricalshockandexplosion

hazardcanbecaused.

Page 9: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

1615

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

4.3Connections

4.3.1ThreadConnection

Note:DefaultThreadisMaleGThread,otherthreadareavailableonrequest.Forexample:FemaleNPTThread,

MaleNPTThread;Consultusformoreinformation

Diameter(mm) L(mm) ThreadCriteria

25 170 G2”

40 140 G2”

50 150 G2-1/2”

4.3.2FlangeConnection

ANSIFlangeMeterDimensions

SizeCode A ANSIFlangeRatingClass

FlangeDiameter(B) BoltHole BoltCircle BoltHoleQuantity

(inch) (mm) (mm) (mm) (mm) (mm)

1" 25 170 150 108 16 79 4

1-1/2" 40 200 150 127 16 99 4

2" 50 200 150 152 19 121 4

2-1/2" 65 240 150 180 19 140 4

3" 80 240 150 191 19 152 4

4" 100 300 150 229 19 191 8

5" 125 240 150 255 22 216 8

6" 150 450 150 279 22 241 8

8" 200 500 150 343 22 298 8

10" 250 500 150 460.4 25 362 12

12" 300 300 150 482.6 25.4 431.8 12

Page 10: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

5.2LWQ-A:Two-wire4-20mAOutput,NoLocalDisplay

TerminalSymbols Description

+A PowerSupply:“24V+”

-B CurrentOutput

TerminalConfiguration TerminalWiring

A -B

LWQ-A

1817

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

DINFlangeMeterDimensions

SizeCode ADINFlangePressureRating

FlangeDiameter(B)

BoltHoleDiameter

BoltCircleDiameter(PCD)

BoltHoleQuantity

(inch) (mm) (mm) MPa (mm) (mm) (mm)

1" 25 170 1.6 115 14 85 4

1-1/2" 40 200 1.6 150 18 110 4

2-1/2" 65 240 1.6 185 18 145 4

3" 80 240 1.6 200 18 160 8

4" 100 300 1.6 220 18 180 8

5" 125 240 1.6 250 18 210 8

6" 150 450 1.6 285 22 240 8

8" 200 500 1.6 340 22 295 12

10" 250 500 1.6 405 26 355 12

12" 300 300 1.6 460 26 410 12

5. ElectricalWiring

Warning:ElectricalHazard;Disconnectpowerbeforebeginningwiring.

TerminalConfiguration TerminalWiring

5.1LWQ-N:PulseOutput,ExplosionProofModel

TerminalSymbols Description

+ PowerSupply:“24V+”

- GND

PulseOutput-

LWQ-NExplosion Proof

Page 11: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

19 20

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

5.3LWQ-Eseries

TerminalboardofEtype

12

34

56

78

910

11

COM+24VloutFoutFout_C

ALAHC_KEY

485_A485_B

GND

COM

PE

GND

COM+PE

PE+GND

NPN

PNP OC

24VLithiu

m

Battery

Batterysocket

PNPoutput NPNoutput OCoutput

ThePNP,NPNandOCoutputcouldbechosenbyshortenthefollowingterminals.

Ifthesignalisinterferedatworkingsite,pleasetrytoshorttheterminalsasfollowingdrawing(a).After“a”step,ifthesituationisnotimproved,pleaseshorttheterminalsasdrawing(b)

a b

Wireterminals

5.5.1Currentoutput(E2,E4,E5,H)

TerminalConfiguration TerminalWiring

TerminalSymbols

Description

1 GND

2 24VDC+

3 Currentoutput

b. 3wireCurrentoutput(E4,E5)

TerminalSymbols

Description

2PowerSupply:

“24V+”

3 CurrentOutput

a. 2wireCurrentoutput(E2,H)

12

34

56

78

910

11

COM+24VloutFoutFout_C

ALAHC_KEY

485_A485_B

GND

COM

PE

GND

COM+PE

PE+GND

NPN

PNP OC

24VLithium

Battery

TerminalSymbols

Description

9 485_A

10 485_B

c. RS485Communication

Notice:(LWGY-E1ISPOWEREDSUPPLYBYBATTERYONLY,NOOUTPUT)

Notice:1.E4is0-20mAoutputandE5is4-20mAoutput

2.TheRS485doesnotworkunder2-wireconnectionsituation

Page 12: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

21

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

22

Frequency&Pulseoutput(E2,E3,E4,E5,H,R)

TerminalConfiguration

OutputType MenuP7 MenuP8 MenuP9

Frequency 1 --- ---

ScaledPulse 2 Needtoset Needtoset

TerminalSymbols

Description

1 GND

2 24VDC+

5 Frequency/Pulseoutput

TerminalWiring

12

34

56

78

910

11COM+24VloutFoutFout_C

ALAHC_KEY

485_A485_B

GND

COM

PE

GND

COM+PE

PE+GND

NPN

PNP OC

24VLithium

Battery

5.5.2Frequency&Pulseoutput(E2,E3,E4,E5)

Note:Theparameterneedtosetasfollowingform.

5.5LWQ-H ElectricalWiringDiagram

Function List for converter with local displayModel PowerSupply Output OptionalDualOutput Communication

LWQ-H 24V DC 4-20mA(2wire) NotAvailable HART

TerminalSymbols

Description

2PowerSupply:

“24V+”

3 CurrentOutput

12

3

COM+24Vlout

TerminalWiring

Page 13: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

AH

5.4.2LWQ-D2:3wire4-20mA,Pulse&SureprotocolRS485

/N

OFF

ĒÆĔ

AH

AL

AL

485A

485A

485B

485B

FOUT

FOUT

AGND

AGND

IOUT

IOUT

24V+

24V+

PE

PE

RIGHT UP ESC

12

3

ON

DP

BAT1

3-wire4~20mA,pulse&RS485

AH

AL

485A

485B

FOUT

AGND

IOUT

24V+

PE

24V+

SureprotocolRS485

د -

mA

RL

Pulseoutput+ElectricalWiringDiagram

mAmeter0...20mAor4...20mAandotherR istheinternalresistanceoftheL

measuringpointincludingthecableresistanceد -

mA

RL

Note:

23 24

5.4LWQ-D:LocalDisplay(Temperature&PressureCompensation)

5.4.1LWQ-D1:2wire4-20mA,RS485

Battery

J1 J2 J3

J4

lo

GND

24V+

A

B

P

Power Supply

RS485

GND

A2A1

PIC

Pi

Vcc

GND

Po-

Po+

Pi+

Pi-

T11

T12

T21

T22

FlowSensor

PressureSensor

Temperature

Sensor

lo

GND

24V+

A

B

P

د -

mA

RL

GND

24V+

ModbusRS485

ElectricalWiringDiagram

2wire4-20mA,MODBUSRS485

mAmeter0...20mAor4...20mAandotherR istheinternalresistanceoftheL

measuringpointincludingthecableresistance

د -

mA

RL

Note:

Page 14: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

25

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

26

6.2.2FullScaleCalibration:It'sONLYavailableforfactory;Returntheflowmetertofactoryforfull

scalecalibrationwhereisapplicable.

6.1LWQ-N:Nodisplay;PulseOutput

CustomershouldsetthecorrectK-factorintoPLCorFlowtotalizerinordertogetthecorrectflowrate.

6.2LWQ-A:Nodisplay;4-20mAOutput

OnlyperformtheZeroPointCalibrationwhereit'snecessary.

Allflowmetersaretestedandcalibratedpriortoleavingthefactory,andtheuniqueK-factorisprovided

onthecalibrationcertificate.KeepthecalibrationcertificatewelltoavoidthelossofK-factor.

6. ProgrammingandSetup

6.2.1ZeroPointCalibration

(1)Shutoffthevaluewheretheflowmeterisinstalled,ensurethereisnoflowrateinpipe.

(2)Puthighaccuracyamperometerintothecircuitloopasseriesconnection.

(3)AdjustthepotentiometerW502tomakesurethedisplayonamperometeris4mA.

(1)Underanysettingstatus,press“ESC”meansnosavecurrentsettingandbacktomeasuringmode.

(2)Nopasswordinputtingorpressing“Enter”withincorrectpasswordcanONLYviewallparameters.

Thetotalmenusin“ParametersSet”are26,anduserscanaccessandmodifythesemenusdepending

ontheinputpasswordgrade.Seetablebelowformoreinformationonpasswordgrade.

Table.DescriptionofPasswordGrade

Password LoginPrivileges

NoPassword ReadOnly

1234 ModifyParameterP1-P14

1010 ModifyParameterP16-P26

5555 SettingTotalratereset

1111 Savealldataasfactorydefaults

5678 ReloadFactoryDefaults

9999 TotalFlow

6.3LWQ-E

6.3.1Description

Page 15: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

28

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

27

6.3.2DisplayAndKey

Refertopage28

TotalFlow

Batterysituation

ExternalpowerSign

RS485Sign

HARTSign

Flowrate

High/lowlimitalarm

Flowratepercentage

Key MeasuringMode MenuModeSub-menuor

FunctionModeParameterandData

Mode

Enter

SelectmenuSavethevalueandadvancetonextmenu

EscReturntomeasuringmodebutpromptwhetherthedatashouldbesaved

Returntomeasuringmodebutpromptwhetherthedatashouldbesaved

Note:Dataarenotsavedwhenpress“Esc”toreturntomeasuringmode.Ifthevalueneedtobechanged,press“Enter”tosavevaluefirst

6.3.3Operation

Page 16: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

3029

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

Menu Parametername SettingMethod Grades Range

P--1 Unit SelectParameter User

Value FlowRateUnit TotalRateUnit

0 3m /h 3m

1 L/h L

2 L/min 3m

3 USGal/min USGal

4 UKGal/min UKGal

5 USGal/h USGal

6 UKGal/h UKGal

7 Kg/h Kg

8 t/h t

9 3ft /h 3ft

P--2DampingTime

InputValue UserUnit:SecondValue:0-9

P--3 MaximumFlowRate InputValue User Unit:ThesameasFlowRate

P--4 MinimumFlowRate InputValue UserMinimumflowrate(whentheflowrateislowerthanit,theflowratewillshow0);Unit:ThesameasFlowRate

Menu Parametername SettingMethod Grades Range

P--5 MaximumFrequencyoutput InputValue User Accuracy:0.1Hz

P--6 Relativedensity InputValue User Relativedensity:1(waterdensityat4℃)

P--7 FrequencyOutputMode SelectParameter User

0:NoFrequencyoutput

1:CorrectedPulseoutputafter

2:ScaledPulseoutput

P--8 Scaled-pulseoutput SelectParameter User

0.01 0.01L/Pulse

0.1 0.1L/Pulse

1 1L/Pulse

10 10L/Pulse

100 100L/Pulse

P--9Pulsewidth

InputValue UserThevalueshouldbemultipleof10;Theunitsisms

P--10 Communication SelectParameter User0:RS485

1:Hart

Page 17: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

3231

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

Menu ParameterName SettingMethod Grades Range

P--11RS485

Address: Input User Maxis255

BaudRate: SelectParameter User 1200,2400,4800,9600,19200

Verification: SelectParameter User

N(Noverify)

O(Oddverify)

E(EvenVerify)

DataLength SelectParameter User 7,8

Stopbitslength SelectParameter User 1,2

Hart DeviceAddress SelectParameter User

P--12HighLimitAlarm SelectParameter User

Yes:On

1%-100%:Percentageofupperlimitflowrate

P--13 LowLimitAlarm SelectParameter User 1%-100%:Percentageofupperlimitflowrate

P--14 Backlight SelectParameter User

0:OffBacklight

1:Automaticmode

2:ONmode

P--15 TotalRate Inputvalue User Itcouldbemodifiedwithrightcode

Menu ParameterName SettingMethod Grades Range

P--16F--1

LinearizationoftheFlowcurve:point1

Inputvalue FactoryONLYFirstRow:Frequency(P1)

SecondRow:K-Factor(P1)

P--17F--2

LinearizationoftheFlowcurve:point2

Inputvalue FactoryONLYFirstRow:Frequency(P2)

SecondRow:K-Factor(P2)

P--18F--3

LinearizationoftheFlowcurve:point3

Inputvalue FactoryONLYFirstRow:Frequency(P3)

SecondRow:K-Factor(P3)

P--19F--4

LinearizationoftheFlowcurve:point4

Inputvalue FactoryONLYFirstRow:Frequency(P4)

SecondRow:K-Factor(P4)

P--20F--5

LinearizationoftheFlowcurve:point5

Inputvalue FactoryONLYFirstRow:Frequency(P5)

SecondRow:K-Factor(P5)

P--21F--6

LinearizationoftheFlowcurve:point6

Inputvalue FactoryONLYFirstRow:Frequency(P6)

SecondRow:K-Factor(P6)

P--22F--7

LinearizationoftheFlowcurve:point7

Inputvalue FactoryONLYFirstRow:Frequency(P7)

SecondRow:K-Factor(P7)

P--23F--8

LinearizationoftheFlowcurve:point8

Inputvalue FactoryONLYFirstRow:Frequency(P8)

SecondRow:K-Factor(P8)

P--24F--9

AverageK-Factor Inputvalue FactoryONLYFirstRow:Frequency(P)

SecondRow:K-Factor(P)

Page 18: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

3 3433

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

6.4LWQ-DwithTemperatureandPressureCompensation

Warning:ElectricalHazardDisconnectpowerbeforebeginningwiring.

6.4.1LWQ-D1Display(2-wire4-20mA)

6.4.1.1Display

Representation

总量

Total3

TotalFlow;Unit:Nm

日量

Summ.3

TotalFlowinoneday;Unit:Nm

流量

Flow3

Flowrate;Unit:Nm /h温度

Temp. Temperature;Unit:CelsiusDegree

压力

Pres.Pressure;Unit:Kpa

Note:It'sgaugepressureunlesswherethereisparticulardeclare

6.4.1.2Hand-heldoperator

Warning:Push“Set”Buttontosaveyoursetting

HAND-HELD DEVICEFOR LWQ-D

SET

EXIT

SetButton

CursorChange

ChangeValue

Quit

Page 19: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

335

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

36

6.4.1.3ParametersIllustration(LWQ-D1)

Page 20: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

337

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

38

6.4.2LWQ-D2

6.4.2.1Display

Page 21: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

339

OperationManual OperationManualGasTurbineFlowMeter

OperationManual OperationManualGasTurbineFlowMeter

40

6.4.2.2Keys(Seetablebelowforfunctionandrepresentationintext)

ESC

SET

RIGHT

UP

KeyMeasuringMode

Sub-menuorFunctionMode ParameterandDataMode

1.Displaythefrequencycorrespondingtoflowrate2.Entertheparametersettingmode

Press1time,returntomenumode,datasaved

Savethevalueandadvancetonextmenu

Fornumericalvalues,movecursoronepositiontotherightorleft

Usecursorhighlightedtochangenumber,unit,setting

Returntomeasuringmodebutpromptwhetherthedatashouldbesaved

Returntomeasuringmodebutpromptwhetherthedatashouldbesaved

Note:Dataarenotsavedwhenpress“Esc”toreturntomeasuringmode.Ifthevalueneedtobechanged,press“Set”tosavevaluefirst

6.4.2.3ParametersSet

ParameterNumber Description

01 TheMaxFlowRate(StandardStatus)correspondingto20mA)

02 k1(FirstK-Factor) linearizationofthe

Flowcurvepoint103 f1(Thefrequencycorrespondingtok1)

04 k2(SecondK-Factor)linearizationoftheFlowcurvepoint205 f2(Thefrequencycorrespondingtok2)

06 k3(ThirdK-Factor)linearizationoftheFlowcurvepoint3

07 f3(Thefrequencycorrespondingtok3)

08 k4(FourthK-Factor)linearizationoftheFlowcurvepoint4

09 f4(Thefrequencycorrespodingtok4)

10 k5(Fifthk-Factor)linearizationoftheFlowcurvepoint511 f5(Thefrequencycorrespodingtok5)

12 k6(SixthK-Factor)

13 PressureUpperLimit

14 LocalAtmosphericPressure

15 DeviceAddress:RS485

16 TotalizerReset(2:ClearTotalizerwithoutcompensated;3:Cleartotalizerwhichhasbeencompensated;9:Clearall)

17 ReservedParameter

Page 22: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

OperationManual OperationManual

4241

GasTurbineFlowMeterOperationManual OperationManual

GasTurbineFlowMeter

Symptom ProbableCause Solution

MoreVolume/Outputthandisplayedor

registered

1.Rotormaydragduetoforeignmatterobstruction.

Checkfordebrisinsidethemeter.

Cleanandreassemble.

2.Magneticpickupnotscreweddownallthewayintotheturbineflowmeterbody.Thiscausesitnottodetectalltherotorbladesastheypass

Screwthemagneticpickupallthewaydownintotheturbineflow-meterbody.Hand-tightenonly.

3.K-factoristoohighinelectronic/readoutdevice

VerifyK-factorused.K-factorshouldbedecreased.

LessVolume/Outputthandisplayedor

registered

K-factoristoolowinelectronic/readoutdevice

VerifyK-factorused.K-factorshouldbeincreased.

Flowrateindicationisunstable

1.GasflowrateisnotstableKeepthevalvepositionandmakesurethegasinpipeisstable

2.BatteryPowerType:BadcontactontheconnectorbetweenbatteryandPCB

Openbackcoverandrepowertheflowmeter

3.DCPowerType:supplyvoltageisabnormal

Checkandensurepowersupplyis24VDC

7. TroubleshootingLimitedWarrantyPolicy

TianjinSUREInstrumentherebyprovidesalimitedwarrantyagainstdefectsinmaterialsandworkmanship.

Thisproductincludesa1-yearwarranty.Thewarrantyperiodshallbeginonthedateoftheoriginalnew

equipmentpurchase.Warrantor’sobligationhereundershallbelimitedtorepairingdefectiveworkmanship

orreplacingorrepairinganydefectiveparts.

IntheeventPurchaserbelievestheSUREproductisdefective,theproductmustbereturnedtoSURE,transportation

prepaidbyPurchaser,withintheappropriatewarrantyperiodrelativetotheproduct.IfSURE’sinspection

determinestheworkmanshipormaterialsaredefectiveandtherequiredmaintenancehasbeenperformedand,

hasbeenproperlyinstalledandoperated,theproductwillbeeitherrepairedorreplaced,atSURE’ssole

determination,freeofadditionalcharge,andthegoodswillbereturned,transportationpaidbySURE,using

atransportationmethodselectedbySURE.

PriortoreturningtheproducttoSURE,PurchasermustobtainaReturnedMaterialAuthorization(RMA)

NumberfromSURE’sCustomerServiceDepartmentwithin30daysafterdiscoveryofapurportedbreachof

warranty,butnotlaterthanthewarrantyperiod;otherwise,suchclaimsshallbedeemedwaived.

IfSURE’sinspectionrevealstheSUREproducttobefreeofdefectsinmaterialandworkmanshiporsuch

inspectionrevealsthegoodswereimproperlyused,improperlyinstalled,and/orimproperlyselectedfor

Page 23: Gas Turbine Flow Meter Model: LWQ - Flutrol Manual... · Gas Turbine Flow Meter Model: LWQ Gas Turbine Flow Meter. 1 2 Table of Contents Table of Contents 1. General Information 1.1

OperationManual OperationManual

4443

GasTurbineFlowMeterOperationManual OperationManual

GasTurbineFlowMeter

serviceintended,SUREwillnotifythepurchaserinwritingandwilldeliverthegoodsbacktoPurchaserupon

ReceiptofPurchaser'swritteninstructionsandagreementtopaythecostoftransportation.IfPurchaserdoes

Notrespondwithinthirty(30)daysafternoticefromSURE,thegoodswillbedisposedofinSURE’sdiscretion.

SUREdoesnotwarranttheproducttomeettherequirementsofanysafetycodeorotherjurisdiction,and

Purchaserassumesallriskandliabilitywhatsoeverresultingfromtheusethereof,whetherusedsinglelyorin

combinationwithothermachinesorapparatus.

ThiswarrantyshallnotapplytoanySUREproductorpartsthereof,whichhavebeenrepairedoutsideSURE’s

factoryoralteredinanyway,orhavebeensubjecttomisuse,negligence,oraccident,orhavenotbeenoperated

inaccordancewithSURE’sprintedinstructionsorhavebeenoperatedunderconditionsmoreseverethan,or

otherwiseexceeding,thosesetinthespecifications.

FORNON-WARRANTYREPAIRSORCALIBRATIONS,consultusforcurrentrepair/calibrationcharges.Have

thefollowinginformationavailableBEFOREcontactingus:

1. P.O.numbertocovertheCOSToftherepair/calibration,

2. Modelandserialnumberoftheproduct

3. Repairinstructionsand/orspecificproblemsrelativetotheproduct.

Thispageisblank

RESERVED