Gas Furnace Planned Maintenance
30

Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Dec 24, 2015

Download

Documents

Osborne Anthony
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Gas Furnace Planned Maintenance

Page 2: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Annual Fuel Utilization Efficiency (AFUE)

• Percentage of the annual average efficiency of a furnace

• All furnaces manufactured after 1992 must have a AFUE of at least 78%

Page 3: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Types of Gas-Fired Furnaces

Natural Draft

Induced-Draft

Condensing

Page 4: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Natural Draft Furnaces

• Rely on the buoyancy of the hot combustion products to create the draft needed to draw combustion products through the heat exchanger and out the vent

• Difficult to obtain a 78% AFUE rating

• Not being produced by most manufacturers

Page 5: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Induced-Draft Furnaces

• Have an AFUE of at least 78%

• Use an inducer fan to draw the products of combustion through the heat exchanger

• Inducer fan restricts the flow of warm air out the vent during the off cycle

Page 6: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Condensing Furnaces

• Have an AFUE rating of at least 90%

• Have an additional heat exchanger which removes the latent heat from the flue gas by condensing the water vapor

• Side wall venting

• Draws in 100% combustion air from outside

Page 7: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Furnace Configurations

Upflow

Downflow

Horizontal

Multipoise

Page 8: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Gas Furnace Components

Gas Valve

Gas Manifold and Orifices

Gas Burners

Heat Exchangers

Burner Ignition Devices

Page 9: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Gas Valves

• Most furnaces will use a combination gas valve

• The basic function of a combination gas valve is:– Automatic and manual shut-off of gas flow to

the main burners & pilot– Pressure adjustment and regulation of the gas

supplied to the gas manifold & pilot

Page 10: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Gas Valves continued….

• Natural gas furnaces use a combination gas valve--it should be adjusted to regulate the outlet gas pressure to 3.2” w.c. to 3.8” w.c.

• LP furnaces may not have a pressure regulator adjustment; if it does, it should be adjusted to regulate the outlet pressure to 10.5” w.c. to 11” w.c.

Page 11: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Gas Manifold & Orifices

• Spuds can be changed in the field to obtain the correct burner input rate

• The spud controls the flow of gas to each of the burners

• The exact orifice size of the spud is determined by the manufacturer

Page 12: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Gas Burners

• Properly mix the gas with the combustion air to the combustion chamber

• Two types:– Multi-port– Mono-port

• The amount of primary air supplied to some multi-port burners can be changed by adjusting the primary air shutter

Page 13: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Burner Ignition Devices

Three basic types

Standing Pilot

Pilot Re-ignition

Direct Ignition

Page 14: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Standing Pilot

• Two types of safety devices:– Thermocouple– Thermally-actuated switch

• Clean orifice carefully

• A properly adjusted pilot flame will have a soft blue color with some yellow at the tip

• Should have a height of 3/8” to 1/2” to impinge on the thermocouple

Page 15: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Standing Pilots continued...

• Normal output voltage of thermocouple is 26 to 32 millivolts DC

• The minimum acceptable output voltage is 12 millivolts DC

• If pilot flame goes out the gas flow to the pilot assembly should drop out within 2-1/2 minutes.

Page 16: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Spark Re-ignition

• Used on mid-efficiency & high-efficiency furnaces

• Output spark typically 15,000 volts

• Pilot flame is proved by either a set of thermally-actuated switches or a flame rectification circuit (more common)

• Never attempt to manually light

Page 17: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Spark Re-ignition continued...

• Clean the components of any dirt, scale, soot or carbon using a soft-bristle brush

• Check high voltage cable for any cracks or poor connections

• Check safety lockout operation– With gas valve off set thermostat to call for

heat, see if gas valve shuts down if no flame is proved

Page 18: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Direct Ignition(Hot Surface Ignitor)

• Used on high efficiency furnaces

• Hot Surface Ignitor directly lights burners

• Uses flame rectification circuit to prove flame

• Made of ceramic - fragile

• Visually inspect for cracks or breaks

• At room temperature the resistance should equal 45 to 90 ohms (if over 110 ohms replace)

Page 19: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Vent Checks

• Visually check for any obstructions

• Visually check for any worn or damaged pipes

• If any problems observed, immediately notice the proper personnel

• Inspect vent pipe to other appliances that may be tied into the furnace(s)

Page 20: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Combustion Testing

Page 21: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.
Page 22: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Category I Appliance

Page 23: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Category I - Appliance Test Point

Page 24: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Category I Appliances

Page 25: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Fan Assisted Furnaces

Page 26: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Category IV Furnaces

Page 27: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Temperature Rise Checks

• Determine temperature rise for data plate

• Generally low-efficiency furnaces will have a temperature rise of 75 to 100 degrees

• Generally high-efficiency furnaces will have a temperature rise of 40 to 70 degrees

• Always check supply temperature out of the line of sight of the heat exchanger

Page 28: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Temperature Rise Checks continued...

• Before checking the temperature rise of a furnace make sure the filter is clean and the airflow is not being blocked

• Use the same type of thermometers for measuring the return and supply temperatures

• Before checking the temperature rise, compare the accuracy of each thermometer against each other

Page 29: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

Safety Controls Checks

• Verify the operation of the high temperature switch.

• Block return airflow completely and observe the gas valve shutting down and at which temperature

• On induced draft furnaces remove one end of the rubber hose from the air pressure switch and observe the gas valve shutting down

Page 30: Gas Furnace Planned Maintenance. Annual Fuel Utilization Efficiency (AFUE) Percentage of the annual average efficiency of a furnace All furnaces manufactured.

THE

END