Top Banner
Furnace Improvements Services Improving Fired Heaters Reliability using Inclined Firing Technology Furnace Improvements 1
65

Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Mar 19, 2018

Download

Documents

vuonghuong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

Services

Improving Fired Heaters Reliability using Inclined

Firing Technology

Furnace Improvements

1

Page 2: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesOperating and Reliability Issues

High tube metal temperatures

Localized flame impingement

Fired heaters have burners that are

fired vertically upright, sideways or

downwards

FIS patented technology reorients

the burners at a slight angle away

from the tubes

Hottest part of the flames and flue

gases are moved away from the

tubes

www.heatflux.com 2

Page 3: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesBenefits of Inclined Firing System

Significant reduction in

tube metal temperatures

Low coking rates

Higher tube life and run

lengths

Increased capacity

possible in most heaters

Uniform firing achieved

across the tubes

www.heatflux.com 3

Page 5: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

INTERHEATER -2 INTERHEATER -1 CHARGE HEATER

35'-6" 35'-6"

5' 5'

6'

5' 5'

4'-6"

5' 5'

4'-6"

5-10deg.

Page 6: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesInclined Firing System

www.heatflux.com 6

Height in

Elevation

BCD

0’-0” 8’-0”

5’-0” 7’-1.5”

10’-0” 6’-3”

15’-0” 5’-4.5”

20’-0” 4’-6”

25’-0” 3’-7.5”

8 burner system

TCD of 20’-8”

2'-7"

Φ21'’-9 1/2"

I/S INS.

Φ20'-8"

TCD

Φ8'-0"

B.C.D.

7'-1 1/2"

B.C.D.

6'-3"

5'-4 1/2"

4'-6"

3'-7 1/2"

57'-

10" W

EL

D T

O W

EL

D L

EN

GT

H

61'-

4 1

/2"

45'-

8 5

/8"

5'-

0" 1

0'-

0" 15'-

0" 20'-

0" 25'-

0"

10'-5"

I/S INS.

Page 7: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesCase Studies

Case studies to be presented include:

Hot Oil Heater

Reformer Heater

Charge Heater, Vertical Cylindrical

Coker Heater

Crude Heater, Cabin Type

Crude Heater-Vertical Cylindrical

CFD Modeling carried out to

demonstrate the benefits of Inclined

Firing System

www.heatflux.com 7

Page 8: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesCFD Modeling

Start

CAD Geometry

CAD Geometry &

Meshing

Boundary

Conditions

Solver

Converged

Solution

Post Processor

Analysis

End

Diverge

Optimization

CFD

Computational Fluid

Dynamics

Uses numerical methods

and algorithms to study

fluid flow

Flow patterns in fired

heaters, burners, fireboxes

3D models of fired

equipment are created

www.heatflux.com 8

Page 9: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesGladieux Processing

Hot oil heater being built with 6 inclined burners

,commissioned in July 2014.

www.heatflux.com 9

Page 10: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFIS-392BClient-GLADIEUX PROCESSING

Location-HUNTINGTON, INDIANA

www.heatflux.com

Page 11: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlue Gas Velocity Contours

Y-Plane

[ft/s]

Page 12: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlue Gas Vector Plot

Long recirculation is observed.

Y-Plane

[ft/s]

Page 13: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlame Contours (CO >2000 ppm)Colored by Temperature (o F)

[°F]

Flame shapes are separate from each other.

[°F]

Page 14: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlame Contours (CO >2000 ppm)Colored by height (ft)

[ft]

[ft]

Page 15: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

Services

Tube Metal Temperature Contours Wall Tubes

Tube Metal Temperatures Flue Gas Temperatures near Tubes

[°F] [°F]

Page 16: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesWall Tubes’ Heat Flux Contours

Average Heat Flux on the Tubes:

10,482 Btu/hr∙ft2

[Btu/hr∙ft2]

Page 17: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

Services

20'-0 7/8" (SHELL WIDTH)

24.0000

8 0.7500

113.0000 113.0000

4.0000 4.0000

24.0000

8 0.7500

EXISTING

4'-0"

2'-8 1/2"2'-8 1/2"

7.0000

5'-5" 5'-5"

20'-0 7/8" (SHELL WIDTH)

24.0000

8 0.7500

113.0000 113.0000

4.0000 4.0000

24.0000

8 0.7500

PROPOSED

4'-0"2'-8 1/2"

2'-8 1/2"

7.0000

5'-5" 5'-5"

3.5o

3.5o

7.0000

C B

UR

NE

RL C B

UR

NE

RL C

BU

RN

ER

L

PROPOSED INCLINED BURNER

EXISTING PROPOSED20'-0 7/8" (SHELL WIDTH)

24.0000

8 0.7500

113.0000 113.0000

4.0000 4.0000

24.0000

8 0.7500

EXISTING

4'-0"

2'-8 1/2"2'-8 1/2"

7.0000

5'-5" 5'-5"

20'-0 7/8" (SHELL WIDTH)

24.0000

8 0.7500

113.0000 113.0000

4.0000 4.0000

24.0000

8 0.7500

PROPOSED

4'-0"2'-8 1/2"

2'-8 1/2"

7.0000

5'-5" 5'-5"

3.5o

3.5o

7.0000

C B

UR

NE

RL C B

UR

NE

RL C

BU

RN

ER

L

PROPOSED INCLINED BURNER

Phillips 66 Billings, MT – DownFired Steam Reformer

Page 18: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesVelocity Vectors on Center Plane

In the proposed case, velocity vectors clearly show improvement in the flue gas flow

pattern with no direct contact of high velocity vectors on radiant tubes.

Base Case Proposed Case

[ft/s]

Page 19: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesTemperature Contours on Center Plane

High flue gas temperature

going towards the tubes.

High flue gas temperature

going away from the tubes.

Base Case Proposed Case

In the proposed case, temperature contours clearly show the reduction in the flue gas

temperature around the radiant tubes.

[°F]

Page 20: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesHusky Lima, OhioCharge Heater with 6 Burners

Page 21: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlue Gas Temperature Contours

Central Plane

[°F]

Temperature

near the

tube is high.

Flame angled

towards the center of

the furnace / away

from tubes.

Existing Case Proposed Modification

Page 22: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlue Gas Temperature Contours

Plane

Location

Existing Case Proposed Modification

Temperature

near the tube

is high.

[°F]

Page 23: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFluid Path Lines: from Fuel Inlet

Existing Case Proposed Modification

Outer

recirculation

pattern

[ft/s]

Page 24: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlame Contours (CO >2000ppm)

[F]

Existing Case Proposed Modification

Colored by Temperature

[°F]

Page 25: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlame Contours (CO >2000ppm)

[ft]

Flame height is14 ft. Flame height is reduce to 9 ft.

Existing Case Proposed Modification

Colored by Height

[ft]

Page 26: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlame Contours (5% O2)

[ft] Existing Case Proposed Modification

Flame

height

is16 ft.

Flame height is

reduce to 9.8 ft.

Colored by Height

[ft]

Page 27: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlame Contours (3% O2)

[ft]

Flame height is 15.2 ft

at 3% O2.

Colored by Height

[ft]

Page 28: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesTube Metal Temperatures

[°F]

Existing Case Proposed Modification

Hot spots due

to flame

impingement.

TMTs more

uniform.

Page 29: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesTube Heat Flux

High heat flux

distribution at

bottom of the

tubes

Existing Case Proposed Modification

[Btu/hr∙ft2]

[Btu/hr∙ft2]

Page 30: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesPhillips 66 Sweeny - Coker Heater

High tube metal temperature

issues

Fuel gas fired low NOx

burners

www.heatflux.com 30

Page 31: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesCoker Heater Geometry

www.heatflux.com 31

ProposedExisting

Burners are

inclined by

7.5° towards

the walls.

Page 32: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesVelocity Vectors

www.heatflux.com 32

Expanded View[ft/s]

Plane at primary tip

Page 33: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesVelocity Vectors by Temperature

www.heatflux.com 33

[°F]

Plane at primary tip

Page 34: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesTube Metal Temperature Contours

www.heatflux.com 34

[°F]

Page 35: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesRefractory Temperature Contours

www.heatflux.com 35[°F]

Page 36: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlame Shapes (Iso-Surface of

CO 2000 ppm)

36Colored by Temperature [°F]

B-4B-1 B-2 B-3

Page 37: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlow Profiles - Vertical Up Firingvs Inclined Firing

www.heatflux.com 37

Inclined Firing Vertical Up Firing

[ft/s]

Page 38: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

Services

Flue Gas Temperature Profiles Vertical Up Firing vs Inclined Firing

www.heatflux.com 38

Inclined Firing Vertical Up Firing[°F]

Page 39: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlame Profiles - Vertical Up Firing

vs Inclined Firing

www.heatflux.com 39

Inclined Firing Vertical Up Firing

Page 40: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesPhillips 66 Sweeny - Crude Heater

Cabin heater – suffering

from high tube metal

temperatures at arch

Originally 6 large

burners-30 MMBtu/hr

each

Proposed 36 burners-5

MMBtu/hr each with

inclined firing mode

Page 41: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFlames Colored by Height

CO 2000 PPM

Base Case Proposed Design[ft]

Page 42: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesVelocity Vectors - Z-1 Section

Base Case Proposed Design

Z-1Z-1

Z-2 Z-2

[ft/s]

Page 43: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesTemperature Contours at Z Sections

Base Case Proposed Design[°F]

Page 44: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesRadiant Tube Temperature

Contours

Base Case Proposed Design

[°F]

Page 45: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesCitgo Corpus Christi - Crude Heater

Client facing flame

impingement and high tube

metal temperatures in radiant

section

FIS recommended inclined

burner firing system to eliminate

flame impingement

Carried out CFD modeling of

the burners and radiant section

to demonstrate the benefit of the

inclined burner firing system

www.heatflux.com 45

Page 46: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesExisting Burner Arrangement

EXISTING FLOOR & PLENUM ARRANGEMENT

www.heatflux.com 46

Page 47: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesInclined Firing System Burner Arrangement

www.heatflux.com 47

Page 48: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFIS-356DClient-CITGO

Location-CORPUS CHRISTI, TEXAS

www.heatflux.com

Page 49: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFIS-356DClient-CITGO

Location-CORPUS CHRISTI, TEXAS

www.heatflux.com

Page 50: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesVelocity Vectors

Base Case vs Inclined Firing System

www.heatflux.com 50

0 ft

Height in

Feet

19 ft

36 ft

50 ft

[ft/sec]

Existing Case

with Vertically Fired

Burners

Proposed Case

with Inclined Firing

System

Page 51: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesTemperature ContoursBase vs Inclined Firing System

Base Case Inclined Firing System

www.heatflux.com 51

[°F]

Page 52: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesTemperature Contours at 10ftBase Case vs Inclined Firing System

Base Case Inclined Firing System

At 10 ft At 10 ft

www.heatflux.com 52

[°F]

Page 53: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesTemperature Contours at 15 ft -

Base Case vs Inclined Firing System

Base Case Inclined Firing System

1

At 15 ft At 15 ft

www.heatflux.com 53

[°F]

Page 54: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesCO Mass Fraction Contours at 10 ftBase Case vs Inclined Firing System

At 10 ft

Inclined Firing System

1

Base Case

At 10 ft

www.heatflux.com 54

[ppm]

Page 55: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesCO Mass Fraction Contours at 15 ft

Base Case vs Inclined Firing System

At 15 Ft

Inclined Firing System

1

Base Case

At 15 Ft.

www.heatflux.com 55

[ppm]

Page 56: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

Services

Iso Surface of CO MF 2000 PPM Colored by Temperatures

Base Case vs Inclined Firing System

Base Case Inclined Firing System

Top Viewwww.heatflux.com 56

[°F] [°F]

Page 57: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

Services

Iso Surface of CO Mass Fraction 2000 ppm Colored by Flame Height

Base Case Inclined Firing

System

www.heatflux.com 57

[ft]

Page 58: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesRadiant Wall Temperatures

Base Design Proposed Design

For h =100 Btu/ft2∙h

and T= 800 °F

www.heatflux.com 58

[°F]

Page 59: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesSummary

Citgo reported almost 250 °F reduction

in tube metal temperatures after the

revamp.

Inclined Firing is proven in solving high

tube metal temperatures problems

CFD modeling demonstrated the ability

of IFS to improve performance

FIS is ready to evaluate your heater to

determine whether it is a suitable

candidate for Inclined Firing at no cost. www.heatflux.com 59

Page 60: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesCountryMark Refining

Installation of 4 burners in inclined firing pattern

www.heatflux.com 60

Page 61: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesFIS-367CClient-COUNTRYMARK

Location-MT. VERNON, IN

www.heatflux.com

Page 62: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesHPCL Mumbai SEU Units

www.heatflux.com 62

F-4202 F-4201

⌽1650 ⌽2350

(TYP.)3°

(TYP.)5.5°

C B

UR

NE

R

C B

UR

NE

R

3200 (P.C.D.) 3962 (P.C.D.)

762 1372

B.C.D. B.C.D.

FLOOR PLT. FLOOR PLT.

L

L

C B

UR

NE

R

C B

UR

NE

RL

L

Page 63: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

ServicesAlon Refining - Big Spring, TX

Two vertical cylindrical heaters working for almost 3

years with Inclined Firing System

Reduced fouling and hot spots

Provided 10% extra capacity

with Inclined Firing Technology

Page 64: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

Services

ALON USA LPBIG SPRING, TEXAS

www.heatflux.com

Page 65: Furnace Services Improving Fired Heaters Reliability using Inclined Firing Technology Fired Heaters... ·  · 2015-07-28Services Improving Fired Heaters Reliability using Inclined

Furnace

Improvements

Services

We hope you found our presentation helpful and informative.

www.heatflux.com 65