Top Banner
PSYC 4380 Rhythms of the Brain Cycle 4: Methods Functional Magnetic Resonance Imaging
15

Functional Magnetic Resonance Imaging. All subatomic particles possess a property called ‘spin’ i.e. like a planet rotating on it’s axis Magnetic.

Dec 24, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

PSYC 4380 Rhythms of the BrainCycle 4: Methods

Functional Magnetic Resonance Imaging

Page 2: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

Physics behind MRI

All subatomic particles possess a property called ‘spin’ i.e. like a planet rotating on it’s axis

Magnetic fields can perturb and align these axes of rotation

Page 3: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

Physics behind MRI

The central component of an MRI scanner is a very powerful magnet

The earth’s magnetic field is 1/20,000 T

Scanner magnets are typically ~3T (60,000x stronger than earth’s field)

Page 4: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

MRI – Basic Principles

Use powerful magnet to align hydrogen atoms in biological tissue

Transmit radio-frequency (RF) pulses to perturb the rotational axes of protons

Record RFs emitted by protons as they return the orientation imposed by large magnet, and use this to calculate H+ density

Page 5: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

MRI – Basic Principles

H+ density varies in different types of biological tissue, and MRI has sufficient sensitivity to distinguish different tissue types

Page 6: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

MRI – Basic Principles

The proton-emitted RF pulse can be measured in a number of ways:

1. Measure the rate at which protons are realigned with the magnetic field (‘T1’)

2. Measure the drop-off in emitted RF pulses from protons as they realign (‘T2’)

T1 and T2 values at 1.5 T

Tissue T1 (ms)

T2 (ms)

Grey Matte

r920 100

White Matte

r790 92

Page 7: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

Magnetic Properties of HB Hemoglobin’s magnetic properties

depend on whether it is oxygenated (HbO2) or deoxygenated (Hb)

HbO2 is ‘dimagnetic’ and has no net effect on the magnetic field

Hb is ‘paramagnetic’ and thus increases the strength of the local magnetic field when aligned by the scanner magnet

Page 8: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

BOLD Signals

BOLD = Blood Oxygen Level Dependent

The change in Hb’s magnetic properties as a function of it’s oxygenation allow us to measure changes in blood oxygenation

Always a relative measure (A-B)

Page 9: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

BOLD Signals

What is the relationship of the BOLD signal to electrophysiological signals?

from Logothetis, J Neurosci 2003

Page 10: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

BOLD Signals

The selectivity of spiking & BOLD signals are not identical

So what is thebest electricalcorrelate of BOLD?

Page 11: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

BOLD Signals

from Logothetis et al., Nature 2001

Simultaneous recording of action potentials (MUA), local field potentials (LFPs), and BOLD suggest BOLD is more like LFPs than MUA

Page 12: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

BOLD Signals

Simultaneous fMRI and electrical recordings reveal widespread BOLD activation for local excitatory stimulation

from Lee et al., Nature 2010

Page 13: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

BOLD Signals

negative BOLD & neural inhibition

from Lee et al., Nature 2010

Page 14: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

BOLD Signals

What can you infer from the absence of a BOLD response?

Positive BOLD response?

Negative BOLD response?

Page 15: Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.

Common Pitfalls in fMRI Analysis & Interpretation

Group averaged data- smoothing -> blurring of distinct loci of activation- heterogeneity of activation location across subjects can obscure consistent within-subject results

Common coordinates- reported centroid of an activated cluster can be misleading about it’s extent

[A > C, B !>C ] -> [A > B]- A and B could have same means, different variances

“Activation relative to A or deactivation relative to B”- Can never really tell

Multiple Hypothesis Testing - lack of / under-correcting can lead to spurious type I errors - parametric over-correction can lead to many type II errors