FTM SeriesOptical Termination Rack (Central Office)
FeaturesProvide efficient termination, storage, splicing and management of
optical fibers from Central office to OSP.
Suitable for indoor application inside central office.
19 inch rack mounted concept with expandable modular FDU,
splitter module.
Storage shelf provided for excess patch cord.
Splitter module and Fiber Monitoring system available for option.
Compatible with Industry standard equipment. (ETSI,EIA)
Front View
FTM-1000F
Rear View
Optical Test Unit
Easy access to each port
Splitter ModuleSplitter Module Unit
Optical Fiber Selector
Splice tray for OSP cable
2D-barcode tag Cord bundled cable
Coupler integrated module
Specifications
Option
Item Content
Using of Area Indoor
Direction of access Front and Rear access
Number of OSP cable Max:21 cables
Number of Termination UnitMax.7units
(Max.port No. 1008F=144Fx7units)
19 rack mount (EIA standard)
4U size (177.8mm)
Connector Type SC
Dimension (mm) W800 x H2200 x D600
Wight (kg) Approx. 250
Main body Steel Thickness ; 2.0mm
Color Light Gray
Item FTM-1000F FTM-600F FTM-300F
Rack 1set 1set 1set
Splice/Patching Unit 7units 4units 2units
Storage Shelf 1set 1set 1set
Cable Clamp 1set 1set 1set
Accessories 1set 1set 1set
For Fiber Monitoring System
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
30
8/12/2019 Fujikura - Optical Components
2/42
Notes
Optical Termination Rack
Variety Type of Termination Rack
Only Front Access type
(Depth 300mm)
1,000-port Termination Rack
SC connector , Splice Tray
For all your connection needs
Full Customization for Full Flexibility
Super High Density type
4,000-port Termination Rack
MU connector, pre-connectorized cable (OSP cable)
(Fiber Monitoring system integrated)
Standard type
2,400-port Termination Rack
SC2 connector , Splice Tray
31
8/12/2019 Fujikura - Optical Components
3/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
Specifications of FDC
ApplicationsFTTH OSP network applications.
Fiber Distribution Cabinet FDC Series
Splitter
Splice Tray
Splice TrayConnector
Adapter
Fusion Splice Point
Features & BenefitsModular distribution units and splitter modules allow scalable high-value
assets, such as optical splitters, to match take rates.
Front door entry allows easy access.
R-guide and cord guide provided for simplified routing and neat fiber
management.
Expandable to larger capacity upon request.
The FDC fiber distribution cabinet is a local convergence hub in the outside plant envi-ronment for multiple subscribers. It provides easy testing and troubleshooting access
as all splitters are at the same point.
Parameter FDC-144FB(N)(1)
Installation Outdoor, Pad Mount
Degree of Protection (IP Code) IP55 (IEC 60529)
Access Front & Rear
Function
(1) Incoming / Outgoing Cable Termination
(2) Splitting (PON) / Bypass (Point-to-point)
(3) Cross-connect
Configuration
(1) Outdoor Cabinet with 19"" Rack Frame: 1
(2) Splice / Patching Shelf (Input, 34F, 2U): 1(3) Splice / Patching Shelf (Output, 128F, 4U): 1
(4) Splitter Module Rack (4U): 1
(5) Cable Management Guide: 1
Splitter Module Capacity 18 modules / rack
Connection Type Splice & Connector
Number of Connection Input: 34; Output: 128
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Splice Capacity Input: 48F (2 trays); Output: 144F (6 trays)
Appl icable Incoming / Outgoing Cable
Entry Bottom
Number 8
Diameter [mm] 11 to 16
Main Body Paint-coated Stainless Steel; Light Gray
Dimensions [mm] 660 W x 1,115 H x 140 D
Weight [kg] Approx. 100
(1) Please contact us for larger capacity, customized designs / configurations / modules.
Splitter Module
Splice/patching shelffor Input cable
Splice/patching shelffor Output cable
Cord spool
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
32
8/12/2019 Fujikura - Optical Components
4/42
Notes
Fiber Distribution Cabinet FDC Series
Specifications of Splitter Modules (FSC-110 Series)(2 )
Ordering Information# Model Number Description
1 FDC-144FB(N)(APC)(3) Fiber Distribution Cabinet, Outdoor, 144F, SC/APC, No Splitters2 FDC-144FB(N)(UPC)
(3)Fiber Distribution Cabinet, Outdoor, 144F, SC/UPC, No Splitters
3 FSC110-1 x 4-SC/APC Spli tte r Module, 1 x 4, SC/APC, Receptacle
4 FSC110-1 x 8-SC/APC Spli tte r Module, 1 x 8, SC/APC, Receptacle
5 FSC110-1 x 16-SC/APC Spl it te r Module, 1 x 16, SC/APC, Receptac le
6 FSC110-2 x 4-SC/APC Spli tte r Module, 2 x 4, SC/APC, Receptacle
7 FSC110-2 x 8-SC/APC Spli tte r Module, 2 x 8, SC/APC, Receptacle
8 FSC110-2 x 16-SC/APC Spl it te r Module, 2 x 16, SC/APC, Receptac le
9 FSC110-1 x 4-SC/UPC Spli tte r Module, 1 x 4, SC/UPC, Receptacle
10 FSC110-1 x 8-SC/UPC Spli tte r Module, 1 x 8, SC/UPC, Receptacle
11 FSC110-1 x 16-SC/UPC Spl it te r Module, 1 x 16, SC/UPC, Receptac le
12 FSC110-2 x 4-SC/UPC Spli tte r Module, 2 x 4, SC/UPC, Receptacle
13 FSC110-2 x 8-SC/UPC Spli tte r Module, 2 x 8, SC/UPC, Receptacle
14 FSC110-2 x 16-SC/UPC Spl it te r Module, 2 x 16, SC/UPC, Receptac le
(3) No pigtails / fiber protection sleeves included.
FSC-110 series
Parameter 1 x 2 1 x 4 1 x 8 1 x 16 1 x 32
Installation Splitter Module Rack fo r FSC-110 (19", 3U)
Module Capacity 18 9 4
Fiber Singlemode
Operating Wavelength [nm] 1,290 - 1,330, 1480-1500, 1530-1570
Operating Temperature & Humidity -10 to +40 degC, 90 % RH
Storage Temperature & Humidity -20 to +70 degC, 95 % RH
Splitter ModuleInsertion Loss [dB] 4.3 8.0 11.6 14.9 18.4Uniformity [dB]* 0.9 2.0 1.0 1.5 2.0
Return Loss [dB] 50 (UPC,APC)
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Dimensions [mm] W x H x D 22 x 130 x 117 47 x 130 x 117 97 x 130 x 117
*Except connector loss uniformity
(2) Please contact us for customized designs / configurations / modules.
Splitter module rack (for FSC-110)
33
8/12/2019 Fujikura - Optical Components
5/42
Latest information also available on the internet URL :www.fujikura.co.jp For Enquiry Email : [email protected]
Features & BenefitsSuitable for interconnect, cross-connect, customer premise and
various environments.
Compatible with industry standard equipment frames.
Light weight for easy installation.
Slide-out drawer for easy access to connectors and splice trays.
Various connector interfaces available upon request.
Customized designs and integrated or extremely-dense cabling
systems available upon request.
Specifications (Simplex SC Type)
ApplicationsTelecommunication Central Offices.
Customer Premises.
Outdoor Cabinets.
Data Centers.
CCTV Security Systems.
SCADA Systems. etc.
Rack-mount Patch Panel FDU Series
FDU-24F (LC)-CA
Parameter4F
SC
24F
SC
36F
SC
48F
SC
72F
SC
96F
SC
144F
SC
288F(1)
SC
Installation Indoor, 19" Rack Mount (EIA)
Main Body Material Aluminum
Color Black
AdapterType Simplex SC; Compliant with IEC 61754-4 (Green for Singlemode APC or Blue for Singlemode UPC)
Number 4 24 36 48 72 96 144 288
Splice Capacity(2)
24 (1 tray) 48 (2 trays) 72 (3 trays) 96 (4 trays) 144 (6 trays) 288 (12 trays)
Number of Cables 22
(-CA)
4
(-CA4)4
Dimensions [mm] 483 W x 44 H x 310 D (1U) 483 W x 88 H x 310 D (2U) 483 W x 133 H x 310 D (3U)483 W x 177 H
x 310 D (4U)
483 W x 400 H
x 310 D (9U)
Weight [kg] Approx. 2 Approx. 2.5 Approx. 3 Approx. 3.5 Approx. 8
(1) 2 ea of 144F FDU-CAs stacked.
(2) No pigtails or fiber protection sleeves included.
Adapter
Optical
Cable
Connector
Fusion Splice Point
Adapter
Central office applicat ion. Data center applicat ion.
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
34
8/12/2019 Fujikura - Optical Components
6/42
Notes
Rack-mount Patch Panel FDU Series
Specifications (Duplex LC Type)
Parameter4F
LC
24F
LC
36F
LC
48F
LC
72F
LC
96F
LC
144F
LC
288F(1)
LC
Installation Indoor, 19" Rack Mount (EIA)
Main Body Material Aluminum
Color Black
AdapterType Duplex LC; Compliant with IEC 61754-20 (Blue for Singlemode UPC or Beige for Multimode PC)
Number 2 12 18 24 36 48 72 144
Splice Capacity(2)
24 (1 tray) 48 (2 trays) 72 (3 trays) 96 (4 trays) 144 (6 trays) 288 (12 trays)
Number of Cables 22
(-CA)
4
(-CA4)4
Dimensions [mm] 483 W x 44 H x 310 D (1U) 483 W x 88 H x 310 D (2U) 483 W x 133 H x 310 D (3U)483 W x 177 H
x 310 D (4U)
483 W x 400 H
x 310 D (9U)
Weight [kg] Approx. 2 Approx. 2.5 Approx. 3 Approx. 3.5 Approx. 8
(1) 2 ea of 144F FDU-CAs stacked.
(2) No pigtails or fiber protection sleeves included.
Specifications (Cable Organizer)Parameter FTB-R-WMPT (1U)
installation Indoor,19" Rack Mount (EIA)
Colo Black
Dimensions [mm] 482 W x 43 H x 267 D (1U)
Weight [kg] Approx. 2.6
Ordering Information# Model Number Description
1 FDU-4F (SC/APC)-CA FDU, 4F, 4 Simplex SC/APC, Green, 2 Cable Clamps
2 FDU-24F (SC/APC)-CA FDU, 24F, 24 Simplex SC/APC, Green, 2 Cable Clamps
3 FDU-36F (SC/APC)-CA FDU, 36F, 36 Simplex SC/APC, Green, 2 Cable Clamps
4 FDU-48F (SC/APC)-CA FDU, 48F, 48 Simplex SC/APC, Green, 2 Cable Clamps
5 FDU-72F (SC/APC)-CA FDU, 72F, 72 Simplex SC/APC, Green, 2 Cable Clamps
6 FDU-96F (SC/APC)-CA FDU, 96F, 96 Simplex SC/APC, Green, 2 Cable Clamps
7 FDU-144F (SC/APC)-CA FDU, 144F, 144 Simplex SC/APC, Green, 2 Cable Clamps
8 FDU-144F (SC/APC)-CA4 FDU, 144F, 144 Simplex SC/APC, Green, 4 Cable Clamps
9 FDU-288F (SC/APC)-CA FDU, 288F, 288 Simplex SC/APC, Green, 4 Cable Clamps
10 FDU-4F (SC)-CA FDU, 4F, 4 S implex SC/UPC, Blue, 2 Cable Clamps
11 FDU-24F (SC)-CA FDU, 24F, 24 Simplex SC/UPC, Blue, 2 Cable Clamps
12 FDU-36F (SC)-CA FDU, 36F, 36 Simplex SC/UPC, Blue, 2 Cable Clamps
13 FDU-48F (SC)-CA FDU, 48F, 48 Simplex SC/UPC, Blue, 2 Cable Clamps14 FDU-72F (SC)-CA FDU, 72F, 72 Simplex SC/UPC, Blue, 2 Cable Clamps
15 FDU-96F (SC)-CA FDU, 96F, 96 Simplex SC/UPC, Blue, 2 Cable Clamps
16 FDU-144F (SC)-CA FDU, 144F, 144 Simplex SC/UPC, Blue, 2 Cable Clamps
17 FDU-144F (SC)-CA4 FDU, 144F, 144 Simplex SC/UPC, Blue, 4 Cable Clamps
18 FDU-288F (SC)-CA FDU, 288F, 288 Simplex SC/UPC, Blue, 4 Cable Clamps
19 FDU-4F (LC)-CA FDU, 4F, 2 Duplex LC/UPC, Blue, 2 Cable Clamps
# Model Number Description
20 FDU-24F (LC)-CA FDU, 24F, 12 Duplex LC/UPC, Blue, 2 Cable Clamps
21 FDU-36F (LC)-CA FDU, 36F, 18 Duplex LC/UPC, Blue, 2 Cable Clamps
22 FDU-48F (LC)-CA FDU, 48F, 24 Duplex LC/UPC, Blue, 2 Cable Clamps
23 FDU-72F (LC)-CA FDU, 72F, 36 Duplex LC/UPC, Blue, 2 Cable Clamps
24 FDU-96F (LC)-CA FDU, 96F, 48 Duplex LC/UPC, Blue, 2 Cable Clamps
25 FDU-144F (LC)-CA FDU, 144F, 72 Duplex LC/UPC, Blue, 2 Cable Clamps
26 FDU-144F (LC)-CA4 FDU, 144F, 72 Duplex LC/UPC, Blue, 4 Cable Clamps
27 FDU-288F (LC)-CA FDU, 288F, 144 Duplex LC/UPC, Blue, 4 Cable Clamps
28 FDU-4F (LC/PC)-CA FDU, 4F, 2 Duplex LC/PC, Blue, 2 Cable Clamps
29 FDU-24F (LC/PC)-CA FDU, 24F, 12 Duplex LC/PC, Beige, 2 Cable Clamps
30 FDU-36F (LC/PC)-CA FDU, 36F, 18 Duplex LC/PC, Beige, 2 Cable Clamps
31 FDU-48F (LC/PC)-CA FDU, 48F, 24 Duplex LC/PC, Beige, 2 Cable Clamps
32 FDU-72F (LC/PC)-CA FDU, 72F, 36 Duplex LC/PC, Beige, 2 Cable Clamps
33 FDU-96F (LC/PC)-CA FDU, 96F, 48 Duplex LC/PC, Beige, 2 Cable Clamps
34 FDU-144F (LC/PC)-CA FDU, 144F, 72 Duplex LC/PC, Beige, 2 Cable Clamps
35 FDU-144F (LC/PC)-CA4 FDU, 144F, 72 Duplex LC/PC, Beige, 4 Cable Clamps
36 FDU-288F (LC/PC)-CA FDU, 288F, 144 Duplex LC/PC, Beige, 4 Cable Clamps
37 FTB-R-WMPT (1U) Cable Organizer, 1U, Tray Type
Patchcords compliant with ISO/IEC 11801 and TIA/EIA-568-C.3 available for customer premises and
commercial building telecommunications cabling.
Simplex and zipcord cables meet TIA/EIA 568-C.3, Telcordia GR-409-CORE and Directive 2002/95/EC
(RoHS) and Plenum, Riser and OFNR-listed LSZH grade jackets available.
LSZH meets the requirement of IEC 61034-1, 61034-2, 60332-1-1,60332-1-2, 60754-1 and 60754-2.
OS1, OS2 and bend-insensitive FutureGuide -SR15E compliant with ITU-T G.657.A1 for singlemode
applications and OM1, OM2, OM3 and OM4 for multimode applications available as options.
35
8/12/2019 Fujikura - Optical Components
7/42
Latest information also available on the internet URL :www.fujikura.co.jp For Enquiry Email : [email protected]
Fiber Distribution Panel FDPanel Series
ApplicationsFiber interconnection and distribution in FTTH, utilities and data networks.Building entrance applications in FTTH, utilities and data networks.
Connector
Adapter
Optical
Cable
Indoor Cable or
Patchcord
1-side Splice Fusion Splice Point
Features & BenefitsProvides connection points for interconnecting and
distributing fibers in interconnection, distribution and
building entrance applications.
Suitable for indoor environments.
Secured with a key.
Swivel patch panel for easy access to connectors (12F, 24F,
36F and 48F).
Customized designs and configurations, such as outdoor
types, two compartment types, customized number of
cables, termination of outgoing round cables with tensionmembers or flat drop cables, etc., available upon request.
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
Specifications (Higher Fiber Counts)Parameter 192F 144F 96F 72F
Installation Indoor, Wall Mount
Patch Panel Fixed
Connection Type Pigtail & Splice(1)
Number of Connection 192 144 96 72
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Splice CapacityIncoming 192F (8 trays) 144F (6 trays) 96F (4 trays) 72F (3 trays)
Outgoing -
Cable Entry Lower
Appl icable Incoming Cab leType 17 mm dia. (Tension Member Clamps applicable)
Number of Holes 2
Appl icable Outgoing Cable (Bunched )Type 17 mm dia. (No Tension Member Clamps, Tied)
Number of Holes 8 6 4 3
Main Body Electro-galvanized Steel; Gray
Dimensions [mm] 440 W x 770 H x 160 D 420 W x 620 H x 160 D 420 W x 470 H x 160 D 420 W x 400 H x 140 D
Weight [kg] Approx. 20 Approx. 17 Approx. 14 Approx. 13
(1) No pigtails or fiber protection sleeves included.
36
8/12/2019 Fujikura - Optical Components
8/42
Notes
Fiber Distribution Panel FDPanel Series
Specifications (Lower Fiber Counts)Parameter 48F 36F 24F 12F
Installation Indoor, Wall Mount
Patch Panel Swivel
Connection Type Pigtail & Splice(1)
Number of Connection 48 36 24 12
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Splice CapacityIncoming 48F (2 trays) 24F (1 tray)
Outgoing -Cable Entry Lower
Appl icable Incoming Cab leType 17 mm dia. (Tension Member Clamps applicable)
Number of Holes 2
Appl icable Outgoing Cable (Bu nched )Type 17 mm dia. (No Tension Member Clamps, Tied)
Number of Holes 2
Main Body Electro-galvanized Steel; Gray
Dimensions [mm] 340 W x 400 H x 130 D 340 W x 330 H x 130 D 340 W x 330 H x 110 D 340 W x 280 H x 80 D
Weight [kg] Approx. 11 Approx. 10 Approx. 9 Approx. 8
(1) No pigtails or fiber protection sleeves included.
Ordering Information# Model Number Description
1 FDPanel-192F SC/APC FDPanel, Indoor, 192F, 192SC/APC, 1-side Splice2 FDPanel-144F SC/APC FDPanel, Indoor, 144F, 144SC/APC, 1-side Splice
3 FDPanel-96F SC/APC FDPanel, Indoor, 96F, 96SC/APC, 1-side Splice
4 FDPanel-72F SC/APC FDPanel, Indoor, 72F, 72SC/APC, 1-side Splice
5 FDPanel-48F SC/APC FDPanel, Indoor, 48F, 48SC/APC, 1-side Splice
6 FDPanel-36F SC/APC FDPanel, Indoor, 36F, 36SC/APC, 1-side Splice
7 FDPanel-24F SC/APC FDPanel, Indoor, 24F, 24SC/APC, 1-side Splice
8 FDPanel-12F SC/APC FDPanel, Indoor, 12F, 12SC/APC, 1-side Splice
9 FDPanel-192F SC/UPC FDPanel, Indoor, 192F, 192SC/UPC, 1-side Splice
10 FDPanel-144F SC/UPC FDPanel, Indoor, 144F, 144SC/UPC, 1-side Splice
11 FDPanel-96F SC/UPC FDPanel, Indoor, 96F, 96SC/UPC, 1-side Splice
12 FDPanel-72F SC/UPC FDPanel, Indoor, 72F, 72SC/UPC, 1-side Splice
13 FDPanel-48F SC/UPC FDPanel, Indoor, 48F, 48SC/UPC, 1-side Splice
14 FDPanel-36F SC/UPC FDPanel, Indoor, 36F, 36SC/UPC, 1-side Splice
15 FDPanel-24F SC/UPC FDPanel, Indoor, 24F, 24SC/UPC, 1-side Splice
16 FDPanel-12F SC/UPC FDPanel, Indoor, 12F, 12SC/UPC, 1-side Splice
37
8/12/2019 Fujikura - Optical Components
9/42
Latest information also available on the internet URL :www.fujikura.co.jp For Enquiry Email : [email protected]
Features & BenefitsProvides distribution points for terminating, splitting and
cross-connecting fibers.
Pass-through riser cable installable.
Various configurations of pre-installed splitters, and
centralized splitting for low-rise building and two stagesplitting with compact splitter modules (FSC114 series) for
high-rise building possible.
Secured with a key.
Customized designs and configurations available upon
request.
ApplicationsFTTH MDU applications. 32 / 64 subscribers supported by 32F / 64F
type. 256 / 512 subscribers supported by 32F / 64F type and 1x8
compact splitter modules (FSC114 series) with two stage splitting.
Fiber Distribution Hub FTB Series
Parameter 32F 64F
Installation Indoor, Wall Mount
Function
(1) Cable Termination
(2) Splitting (PON)
(3) Cross-connect
Configuration
(1) 8 ea of 1 x 4 (1) 16 ea of 1 x 4
(2) 4 ea of 1 x 8 (2) 8 ea of 1 x 8 (3) 1 ea of 1 x 32 (3) 2 ea of 1 x 32
Connection Type (1) Input: Splice; Output: Connector
Number of ConnectionInput 24 (1 tray) 24 (1 tray)
Output 32 64
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Cable Entry Upper & Lower
Appl icable Incoming Cab leType Feeder or Riser Cable (Pass-through possible)
Number 1
Appl icable Outgoing CableType Standard / Low-friction Flat Drop Cable (2 / 1.6 mm t)
Number 32 64
Main Body Steel; Gray
Dimensions [mm] 450 W x 400 H x 110 D 450 W x 440 H x 145 D
Weight [kg] Approx. 15 Approx. 16
(1) No pigtails, fiber protection sleeves or connectors included.
Specifications
Ordering Information# Model Number Description
1 FTB-32D-SP & PT SC/APC 1-1 x 32 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/APC, 1-1 x 32
2 FTB-32D-SP & PT SC/APC 4-1 x 8 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/APC, 4-1 x 8
3 FTB-32D-SP & PT SC/APC 8-1 x 4 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/APC, 8-1 x 4
4 FTB-64D-SP & PT SC/APC 2-1 x 32 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/APC, 2-1 x 32
5 FTB-64D-SP & PT SC/APC 8-1 x 8 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/APC, 8-1 x 8
6 FTB-64D-SP & PT SC/APC 16-1 x 4 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/APC, 16-1 x 4
7 FTB-32D-SP & PT SC/UPC 1-1 x 32 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/UPC, 1-1 x 32
8 FTB-32D-SP & PT SC/UPC 4-1 x 8 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/UPC, 4-1 x 8
9 FTB-32D-SP & PT SC/UPC 8-1 x 4 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/UPC, 8-1 x 4
10 FTB-64D-SP & PT SC/UPC 2-1 x 32 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/UPC, 2-1 x 32
11 FTB-64D-SP & PT SC/UPC 8-1 x 8 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/UPC, 8-1 x 8
12 FTB-64D-SP & PT SC/UPC 16-1 x 4 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/UPC, 16-1 x 4
Connector
Fusion Splice Point
Adapter
Splitter
FAST Connector
Optical Cable
Drop Cable
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
38
8/12/2019 Fujikura - Optical Components
10/42
Notes
SpecificationsParameter Value
Installation Indoor, Wall Mount
Connection Type Fusion or Mechanical Splice
Main Cable Entrance Upper or Lower
Incoming Cable CountRound Cable
(2)(16 mm dia.) 1
Flat Drop Cable (1.6 / 2 / 3.3 mm t) 3
Outgoing Cable Count
Round Cable(2)
(16 mm dia.) 2
Simplex Cable (1.6 / 2 mm dia.) 12
Flat Drop Cable (1.6 / 2 / 3.3 mm t) 24
Splice Capacity(1)Single Fiber (0.25 mm dia.) 24F
Single Fiber (0.9 mm dia.) 8F
4F Ribbon 40F (10 Ribbons)
Through-fiber Capacity
(4F Ribbon)
One Side Branch 160F (40 Ribbons)
Both Side Branch 120F (30 Ribbons)
Splitter Capacity(1)
1 x 4 4 ea
1 x 8 2 ea
1 x 16 1 ea
1 x 32 1 ea
Color Ivory
Dimensions [mm] 160 W x 180 H x 38 D
Weight [kg] Approx. 0.3
(1) Element Dimensions [mm]: 4 W x 4 H x 60 L in Splice Slot; 7 W x 9.5 H x 70 L in Splitter Slot.(2) Tension Member Diameter [mm] 3.2.
Ordering Information# Model # Description
1 FTB-601-12CFiber Splice Box, Indoor, Wall Mount, 24F,
12 Standard Drop Cables.
2 FTB-601-24QFiber Splice Box, Indoor, Wall Mount, 24F,
24 Standard Drop Cables.
3 FTB-601-12C (C)Fiber Splice Box, Indoor, Wall Mount, 24F,
12 Low-friction Drop Cables.
4 FTB-601-24Q (C)Fiber Splice Box, Indoor, Wall Mount, 24F,
24 Low-friction Drop Cables.
5 C sleeveC Sleeve, For 2.5-4.5mm dia. FRP Strength
Member.
Fiber Splice Box FTB-601Features & Benefits
Versatile spl ice box for FTTH MDU applicat ions.Compact and suitable for limited riser space.
Various types of cables can be installed in various directions.
Splitter can be installed.
Mid-span access with through-fibers can be done.
ApplicationsFTTH MDU applications.
Structure
Red:Main Cable into Box
Blue: Flat Drop / Simplex
Cable into Box
Green:
Fibers into Slack Tray
Tension MemberClamp x 3
Cable Clamp x 3
Slack Tray
Splice Slot x 12
(2 ea/slot)
Splitter Slot x 1
Tie Strip
Flat Drop / SimplexCable Clamp
Wiring ConfigurationSpliceThrough-fibers
F lat Drop or Round Simplex Cab le F lat Drop or Round Simplex Cab le
Splice
Through-fibers
SplitterMain Cable Main Cable
39
8/12/2019 Fujikura - Optical Components
11/42
Latest information also available on the internet URL :www.fujikura.co.jp For Enquiry Email : [email protected]
Features & BenefitsIndoor wall-mountable outlet with 1 / 2 / 4 SC port(s) .
Compact and light weight.
Cable entry from any of 4 directions possible to enable
flexible cabling.
ApplicationsFTTH MDU and SDU applications.
Optical Outlet FPB-103A / 302 / 301
FPB-302 FPB-301FPB-103A
Specifications
Parameter FPB-103AFPB-302 FPB-301
(No Suffix) FS PR (No Suffix) FS PR
Installation Indoor, Wall Mount
Connection Type Connector ConnectorPigtail &
SpliceConnector
Pigtail &
Splice
Number of Connection 1 2 4
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Appended Connector s or Pigt ails (1) n/a n/a 2 FAST-SCs 2 Pigtails n/a 4 FAST-SCs4F Ribbon
Pigtail(2)
Incoming Cable Entry Upper, Lower, Right or Left
Appl icable Incoming
Cable
TypeStandard / Low-friction
(3)Flat Drop Cable (2 / 1.6 mm t) with 15 / 7.5 mm Bend Radius Fiber (FutureGuide-SR15E / BIS-B)
n/a Round Cable (8 mm dia.) Round Cable (10 mm dia.)
Number 1F x 1 Discrete 2F x 1 4F Ribbon(2)
x 1
Recommended
Outgoing Cable
Type Bend-insensitive Patchcord (MageTsuyo) with 15 / 7.5 mm Bend Radius Fiber (FutureGuide-SR15E / BIS-B)
Number 1 2 4
Main Body
PC; Ivory;
Compliant with UL-94 V0;
Shutter for Dust-proof and Eye Safety
PC; White Gray;
Compliant with UL-94 V0;
Connector Cover for Protection
PP; White Gray;
Connector Cover for Protection
Dimensions [mm] 50 W x 93 H x 18 D 70 W x 150 H x 15.3 D 76 W x 165 H x 26 D
Weight [kg] Approx. 0.1 Approx. 0.1 Approx. 0.1
(1) No fiber protection sleeves are included.
(2) 4 ea of discrete fiber pigtails for discrete fiber cable are available upon request.
(3) Regarding FPB-302 and FBP-301, low-friction flat drop cable will be secured with cable tie and cable entry will be limited to lower direction for FPB-302 and upper one for FPB-301.
Ordering Information# Model Number Description
1 FPB-103A (APC) Optical Outlet, Indoor, Wall Mount, 1F, 1SC/APC
2 FPB-103A (UPC) Optical Outlet, Indoor, Wall Mount, 1F, 1SC/UPC
3 FPB-302-2SC (APC) Optical Outlet, Indoor, Wall Mount, 2F, 2SC/APC, No Pigtails / Connectors
4 FPB-302-2SC (UPC) Optical Outlet, Indoor, Wall Mount, 2F, 2SC/UPC, No Pigtails / Connectors
5 FPB-302-2SC-FS (APC) Optical Outlet, Indoor, Wall Mount, 2F, 2SC/APC, FAST Connectors
6 FPB-302-2SC-FS (UPC) Optical Outlet, Indoor, Wall Mount, 2F, 2SC/UPC, FAST Connectors
7 FPB-302-2SC-PR (APC) Optical Outlet, I ndoor, Wal l Mount, 2F, 2SC/APC, Pre-assembled Simp lex Pigta ils
8 FPB-302-2SC-PR (UPC) Optical Outlet, I ndoor, Wal l Mount, 2F, 2SC/UPC, Pre-assembled Simplex P ig tai ls
9 FPB-301-4SC (APC) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/APC, No Pigtails / Connectors
10 FPB-301-4SC ( UPC) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/UPC, No Pigtails / Connectors
11 FPB-301-4SC-FS (APC) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/APC, FAST Connectors
12 FPB-301-4SC-FS (UPC) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/UPC, FAST Connectors
13 FPB-301-4SC-PR (APC ) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/APC, Pre-assembled Fan-out Pigtails
14 FPB-301-4SC-PR (UPC ) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/UPC, Pre-assembled Fan-out Pigtails
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
40
8/12/2019 Fujikura - Optical Components
12/42
Notes
Demarcation Box FPB-203
Incoming / Outgoing Direction (Ex.):
Red: Incoming Blue: Outgoing
2 ea of flat drop cables
stackable in a slot.
Incoming Flat
Drop Cable
Outgoing Flat
Drop CableUp to 4 connections.
FAST-SCFAST-SC
FAST-SC Connector
for Flat Drop Cable
SC Adapter
FAST-SC Connector
for Flat Drop Cable
2 ea of SC adapters
stackable in a slot.
SC Adapter
ApplicationsFTTH MDU and SDU applications.
SpecificationsParameter FPB-203-1SC-A(N) FPB-203-2SC-A(N) FPB-203-4SC-A(N)
Installation Indoor and Outdoor, Wall Mount
Degree of Protection
(IP Code)IP55 (IEC 60529)
Connection Type Connector
Number of Connection 1 2 4
Connector Type(1) SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Cable Entry Lower
Appl icable
Incoming Cable(2)
TypeStandard Flat Drop Cable (2 mm t)
with 15 / 7.5 mm Bend Radius Fiber (FutureGuide-SR15E / BIS-B)
Number 4
Appl icable
Outgoing Cable(2)Type Standard Flat Drop Cable (2 mm t)
with 15 / 7.5 mm Bend Radius Fiber (FutureGuide-SR15E / BIS-B)
Number 4
Main Body PC; Gray; Compliant with UL 94 V-1
Lock Lockable with Padlock, etc. (Option)
Dimensions [mm] 104 W x 203 H x 38 D
Weight [kg] Approx. 0.3
(1) Adapter(s) included. No connector(s) included.
(2) Please contact us regarding customized designs for terminations of low-friction flat drop cables
(1.6 mm t), splices of connectorized pigtails, etc.
Ordering Information
# Model Number Description1 FPB-203-1SC-A(N) Demarcation Box, 1F, 1SC/UPC, No Connector
2 FPB-203-2SC-A(N) Demarcation Box, 2F, 2SC/UPC, No Connectors
3 FPB-203-4SC-A(N) Demarcation Box, 4F, 4SC/UPC, No Connectors
4 FPB-203-1SC/APC-A(N) Demarcation Box, 1F, 1SC/APC, No Connector
5 FPB-203-2SC/APC-A(N) Demarcation Box, 2F, 2SC/APC, No Connectors
6 FPB-203-4SC/APC-A(N) Demarcation Box, 4F, 4SC/APC, No Connectors
FPB-203-2SC-A (N)
Features & BenefitsJoints flat drop cables through connectors as a demarcation
box.
Wall-mountable and suitable for indoor and outdoor use.
Lockable with padlock, etc. (option)
41
8/12/2019 Fujikura - Optical Components
13/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
Features19 rack mountable splitter module is signed for FTTH central office
solution.
19 Rack Mountable
Various Splitter Configurations available
1x2, 1x4, 1x8, 1x16 and 1x32; 2 Input Option for Redundancy
Various Connector and Polish Types (SC; UPC, APC) avai lable
Flexible Design and Various Module Configurations are available (Ex. 1x32 in 1U Body)
Easy Installation and Removal with High Density
Applications19 rack mountable splitter module is suitable for 1xn splitting of optical signal, which can cover most of the applications in the fiber distribution
networks like Fiber To The Home (FTTH), especially for the central office solution.
19 rack mountable splitter module shall be accommodated with the chassis in 19 rack.
19 rack mountable splitter module can be used with the fiber distribution unit (FDU series), the fusion splice termination box, and the cable
holder in 19 rack in order to cover most of the applications in the fiber distribution networks.
19 rack mountable splitter module (3U)
Splitter module rack( for FSC-116 ) Splitter module rack( for FSC-110 )
FSC-116 series
FSC-110 series
FDU-96F-A Fusion splice termination box
(Sliding tray type)
Cable holder
42
8/12/2019 Fujikura - Optical Components
14/42
Notes
19 rack mountable splitter module
Ordering Information
Specifications
Product Code
FSC-116- X -SC / Y *
FSC-110- X -SC / Y
Technical characteristics ITU-T L.51 complied
Vibration
IEC61300-2-1A=5mm, f=10Hz, 1,000,000 Cy, No splice case degradation. No damage.
Cable torsion
IEC61300-2-5400mm, Maximum rotation 90/maximum 50 Nm, 5Cy/cable. No splice case degradation.
Temperature cycling IEC61300-2-22 -40C-20C-65C, 8h/Cy 100Cy. No splice case degradation No damage.
Optical characteristicsParameter 1x2 1x4 1x8 1x16 1x32 1x64 2x4 2x8 2x16
Fiber Singlemode
Operating Wavelength [nm] 1,290 - 1,330, 1480-1500, 1530-1570
Splitter Module
Insertion Loss [dB] 4.3 8.0 11.6 14.9 18.4 22.1 8.1 11.7 15.0
Uniformity [dB]* 0.9 2.0 1.0 1.5 2.0 3.0 2.0 1.2 1.5
Return Loss [dB] 50 (UPC,APC)
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
*Except connector loss uniformity
Splitter module rack (for FSC-110)
Type 1x2 1x4 1x8 1x16 1x32 1x64 2x4 2x8 2x16
Module Capacity 18 9 4 n/a 18 9
Dimension (mm) WxHxD 482.6 x 132.6 x 48.0
Splitter module rack (for FSC-116)Type 1x2 1x4 1x8 1x16 1x32 1x64 2x4 2x8 2x16
Module Capacity 36 18 36
Dimension (mm) WxHxD 482.6 x 132.6 x 114.0
Connector type :
UPC : UPC adapter
APC : APC adapter
*Please specify cord length (m)
Splitter type :
1x2 : 1x2 splitte r
1x4 : 1x4 splitter
1x8 : 1x8 splitter
1x16 : 1x16 splitter
1x32 : 1x32 splitter
1x64 : 1x64 splitter
2x4 : 2x4 splitter
2x8 : 2x8 splitter
2x16 : 2x16 splitter
UP to 32 branching is available for FSC-110 series.
43
8/12/2019 Fujikura - Optical Components
15/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FeaturesFSC114 series Wall mountable compact splitter module are
designed for FTTH MDU solution.
Can be direct mounted on the wall, or elevator shaft
Can accommodate Fujikuras termination boxes for the changing
needs of optical networks.
FSC114 seriesWall mountable Compact Splitter Module SC for FTTH MDU solution.
28.4
19.4
105
55
532
35.1
28.8105
57
532
StructureFSC114-1X4SC FSC114-1X8SC
ApplicationsWall mountable compact splitter module is suitable for 1x4 splitting or 1x8 splitting , which can cover most of the applications in the fiber
distribution networks like Fiber To The Home (FTTH), especially for MDU solution.
Wall mountable compact splitter module can be accommodated with the termination boxes.
FSCO-PM-MDU-SP-Box FSCO-PM-2SPMDU
Wall mount box 1:8 Splitter Module SC/APC(ForMDF) FSCO-PM with 1:8 Splitter Module SC/APC(ForMDF)
FSC114-1x4-SC/APC
FSC114-1x4-SC/UPC
FSC114-1x8-SC/APC
FSC114-1x8-SC/UPC
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
44
8/12/2019 Fujikura - Optical Components
16/42
Notes
FSC114 series
Ordering Information
Specifications
Type of Connector :APC :Angled PC
UPC : UPC
Type of Splitter :
4 :1 x 4 splitter
8 :1 x 8 splitter
Product Code FSC114-1X X SC/ Y
Physical characteristics
Material Molded plastic
Dimension1x4 : L 105mm x W 29mmx H 55mm
1x8 : L 105mm x W 36mmx H 57mm
Weight (without kit) 0.2 kg
Technical characteristics ITU-T L.51 complied
Vibration
IEC61300-2-1A = 5 mm, f = 10Hz, 1,000,000 Cy, No splice case degradation. No damage
Cable torsion
IEC61300-2-5400 mm, Maximum rotation 90/maximum 50 Nm, 5Cy/cable. No splice case degradation.
Temperature cycling
IEC61300-2-22-40C-20C-65C, 8h/Cy 100Cy. No splice case degradation No damage.
Item 1 x 4 Splitter Module 1 x 8 Splitter Module
Wavel length 1310 20 nm, 1550 20nm
Insertion loss 8.0 dB 11.6 dB
Uniformity 2.0 dB 1.0 dB
Return loss 50 dB 50 dB
Operating temperature / Humidity - 10 ~ + 40C, 90 %Rh
Except connector uniformity
45
8/12/2019 Fujikura - Optical Components
17/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FeaturesFSCO-PM wall mountable Splice Closures are designed for aerial, strand-mount FTTH drop locations where drop cables are spliced to distribution
cables.
These closures combine grommet cable sealing technology and splice & SC
adapter tray in a strong outer bodyThese closures are compatible with all loose buffer tube and central core
tube
Sleeve with hexagon socket bolt locking mechanism which makes
dismantling/assembling easy
Accommodate SC field terminated Drop Cables installation.
Compatible with most cable types.
Fully mechanical design, fiber reinforced plastic or equivalent
Recommendation of life span for 15 to 20 years (depends on environment).
Concept of separate cable entries system.
Compatible with Fujikuras optical splitter trays for the changing needs of
optical networks.Removable splice tray holder available for convenient aerial splicing.
Laser caution signs provided on cover of the top tray.
Flipped opened and stackable tray available.
Main Cable
Through Fiber
Branching Cable
Drop Cable
Field installable
connector
Fusion Splice
ApplicationsWall mountable Closure is suitable for up to 48 single fiber splicing,
which can cover most of the applications in the fiber distribution
networks like Fiber To The Home / Fiber To The Curb (FTTH/FTTC) .
Pole mount application is possible with pole mount option,Butt, Mid-span access, and Taut Sheath configuration are used. In
addition, wall mount, pole mount application with indoor/outdoor are
possible.
FSCO-PMWall mountable Optic Closures for Drop point
(317)
(141)
(202)
StructureOverview of FSCO-PM
External View Internal View (Wiring)
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
46
8/12/2019 Fujikura - Optical Components
18/42
Notes
Physical characteristics
Material
Molded plastic
Stainless steel
EPDM
Dimension H 317mm x W 202mmx D 141mm
Weight (without kit) 1.2kg
Cable diameter
Main cable
Branch cableDrop cable
11 - 15 mm dia.
11 - 15 mm dia.2 x 3 mm
Through fiber capacity 1.5m x 8 tubes ( 2.4mm Loose tube)
Cable ports
2 for main cable
1 for branch cable
16 for Drop or Indoor Cable/w friction cable)
Splitter tray capacity 1 tray
Splice tray capacity 1 tray
Maximum fiber storage
capacitySingle fiber 24 fiber / tray
No. of splitter 1x4:4pcs or 1x8:2pcs or 1x16:1pcs
FSCO-PM
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
A=5mm, f=10Hz, 1,000,000 Cy, No splice case degradation.
No damage.
Cable fixture(bend)
IEC61300-2-37
400mm, 30 bending or max. 500 N, 5Cy/cable. No splice
case degradation. No damage.
Cable torsion
IEC61300-2-5
400mm, Maximum rotation 90/maximum 50 Nm, 5Cy/cable.
No splice case degradation.
Temperature cyclingIEC61300-2-22
-40C-20C-65C, 8h/Cy 100Cy. No splice case degradation Nodamage.
Impact(free drop)
IEC61300-2-12
0.75m @-15C & +45 C. No splice case degradation.
Degrees of protection
(IP Code) IEC 60529
IP55 : Wind driven rain proof & no effective by dust.
Salt mist
IEC61300-2-26
5% NaCl for 5days, without rust. No damage.
Re-entries
IEC61300-2-33
At least 1 thermal cycle to repeat Open & Close the closure
sleeve 10 times. No damage.
Ordering Information
Specification
X1; Model type
CC : SC adapter connecting type
FS : Fusion splice type (Adaptor not equipped)
X2 ; Splitter module
0SP : No splitter module inside
4SP : 1x4 splitter module inside
8SP : 1x8 splitter module inside
16SP : 1x16 splitter module inside
2(8SP) : 1x8 splitter module x 2set inside
X3; Adapte r type
SC4 : 4xSC/PC
SC8 : 8xSC/PC
SC12 : 12xSC/PC
SC16 : 16xSC/PC SCA4 : 4xSC/APC
SCA8 : 8xSC/APC
SCA12 : 12xSC/APC
SCA16 : 16xSC/APC
Product Code FSCO-PM- X1 / X2/ X3
47
8/12/2019 Fujikura - Optical Components
19/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FeaturesFSCO-AS Aerial Weathertight Splice Closures are designed for aerial,strand-mount FTTH drop locations where drop cables are spliced to
distribution cables.
These free breathing closures combine grommet cable sealing technology
and splice tray, the splitter module is a lso available.FSCO-AS Aerial Weathertight Splice Closures are suitable for special feature
with SSW cable.
Closure adopts hinge/buckle mechanism which makes dismantling/
assembling easy
Cable entry section can accommodate 1 main cable with up to 16c SSWcable.
Can accommodate up to 8 drop cables.
Convenient attachable splitter module with 1:8 splitter module & 1:4
splitter module for drop cable installation.
Re-useable grommet sealing open and close easily for adding or removing
drop cables providing efficient cable installation with no mess.
ApplicationsFSCO-AS Aerial Weathertight Splice Closures is suitable for up to 8 drop cable splicing, which can cover most of the applications in the premisewiring networks like Fiber To The Home (FTTH) .
Aerial application is possible with this closure. FSCO-AS has chemical and mechanical resistance for all the aer ial applicat ion areas in the fiber
networks.
StructureSplice type Splitter module type
FSCO-ASAerial Weathertight Fiber Optic Splice Closures
(387) (70)
(107.
5)
(124)
COVER
LATCH BASE BODY
(43)(387)
(107.
5)
(126)
LatchEnd plate
Cover
Base body
Pass through fibersSSW aerial cable
Splice pointDrop Cable
Drop cable
Main body
Bare fiber operation area
SC adapter connection
SSW aerial cable
Splice point
1:8 splitter
Drop cover
Non bare fiber operation area
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
48
8/12/2019 Fujikura - Optical Components
20/42
Notes
Physical characteristics
Material Molded plastic
Dimension L 387mm x W 70mmx H 124mm( Splitter module type )
Weight (without kit) 0.8 kg
Cable diameterMain cable SSW aerial optical cable: 1pc
Drop cable 2 x 3 mm : up to 8pc
Cable ports 2 for main cable
Maximum fiber storage
capacitySingle-fiber 12 splices points
No. of optical adapter Ma x.8xSC adapter with 1x8 splitter module.
FSCO-AS
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
A=5mm, f=10Hz, 1,000,000 Cy, No splice case degradation.
No damage.
Cable fixture(bend)
IEC61300-2-37
Bending radious:15mm, 90 bending, 3Cy/cable. No splice
case degradation. No damage.
Cable retention
IEC61300-2-4
Mina cable : 98N Drop cable : 49N. No splice case
degradation.
Temperature cyclingIEC61300-2-22
-20C-20C-60C, 8h/Cy 100Cy. No splice case degradation Nodamage.
Impact(free drop)
IEC61300-2-12
0.75m @-15C & +45 C. No splice case degradation.
Degrees of protection
(IP Code) IEC 60529
IPX4 Protected against Wind driven rain proof.
(option :IP54 Wind driven rain proof & no effective by dust.)
Salt mist
IEC61300-2-26
5% NaCl for 5days, without rust. No damage.
Re-entries
IEC61300-2-33
At least 1 thermal cycle to repeat Open & Close the closure
sleeve 10 times. No damage.
Ordering Information
Specifications
Connector typeNull : UPC adapter
A :APC adapter
Splitter type
Example:
4SP : 1 x 4 splitter module
8SP : 1 x 8 splitter module
Product Code
FSCO-AS- X / Y
FSCO-AS Splice type
49
8/12/2019 Fujikura - Optical Components
21/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FeaturesFSCO-AX Aerial Weathertight Splice Closures are designed for aerial,strand-mount FTTH drop locations where drop cables are spliced to
distribution cables.
These free breathing closures combine grommet cable sealing technology
and splice tray in a strong, rodent proof outer body.FSCO-AX Aerial Weathertight Splice Closures are designed for FTTH mid
span jointing with SZ slotted core cable with ribbon tape.
Closure adopts hinge/buckle mechanism which makes dismantling/
assembling easy
Cable entry section can accommodate 1 cables (main cable 1pcs) as themid span jointing.
Can accommodate up to 16 drop cables.
Outer body can be completely removed for 360 degree splice access.
Re-useable grommet sealing open and close easily for adding or removing
drop cables providing efficient cable installation with no mess.
Removable splice tray holder available for convenient aerial splicing.Can accommodate Fujikuras optical splitter into trays for the changing
needs of optical networks.
Pass through fibersCable slotSSW aerial cable
Splice point
Drop Cable
ApplicationsClosure is suitable for up to 16 single fiber splicing, which
can cover most of the applications in the fiber distributionnetworks like Fiber To The Home (FTTH).
Aerial applicat ion is possible with this closure. FSCO-AX has
chemical and mechanical resistance for all the aerial
application areas in the fiber networks. In-ling, Mid-span
access, and Taut Sheath configuration are used.
Structure
FSCO-AXAerial Weathertight Fiber Optic Splice Closures
1503
833
545 5
Sleeve Slack tray (9pcs)
End plate
Aerial h anger
Cable clamp
FSCO-AX
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
50
8/12/2019 Fujikura - Optical Components
22/42
Notes
FSCO-AX
Ordering Information
Specifications
Connector type
Null : UPC adapter
A :APC adapter
Splitter typeExample:
4SP : 1 x 4 splitter module
8SP : 1 x 8 splitter module
Product Code
FSCO-AS- X / Y
FSCO-AX Splice type
Physical characteristics
Material
Molded plastic
ADC
Stainless steel
Dimension L 550mm x W 85mmx H 150mm
Weight (without kit) 2 kg
Cable diameter Main cable 8 15 mm dia.
Drop cable 2 x 3 mmCable capacity 1 6
Cable ports2 for main cable
16 for branch cable (up to 4 port for Drop Cable optional)
Splice tray capacity Max. 9 trays
Maximum fiber storage
capacity
Single fiber 18 fiber (2 fiber/tray)
4-fiber ribbon 36 fiber (1 ribbon /tray)
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
A=5mm, f=10Hz, 1,000,000 Cy, No splice case degradation.
No damage.
Cable fixture(bend)
IEC61300-2-37
400mm, 30 bending or max. 500 N, 5Cy/cable. No splice
case degradation. No damage.
Cable torsion
IEC61300-2-5
400mm, Maximum rotation 90/maximum 50 Nm, 5Cy/cable.
No splice case degradation.
Temperature cyclingIEC61300-2-22 -40C-20C-65C, 8h/Cy 100Cy. No splice case degradation Nodamage.
Impact(free drop)
IEC61300-2-120.75m @-15C & +45 C. No splice case degradation.
Degrees of protection
(IP Code) IEC 60529IP54 Protected against splashing water & no effective by dust.
Salt mist
IEC61300-2-265% NaCl for 5days, without rust. No damage.
Re-entries
IEC61300-2-33
At least 1 thermal cycle to repeat Open & Close the closure
sleeve 10 times. No damage.
51
8/12/2019 Fujikura - Optical Components
23/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FeaturesFSCO-AO Aerial Weathertight Splice Closures are designed for aerial,strand-mount FTTH drop locations where drop cables are spliced to
distribution cables.
These free breathing closures combine grommet cable sealing technology
and splice tray, SC adapter tray in a strong, rodent proof outer body.FSCO-AO Aerial Weathertight Splice Closures are compatible with all loose
buffer tube and central core tube
Closure adopts hinge/buckle mechanism which makes dismantling/
assembling easy
Cable entry section can accommodate maximum 6 cables (main cable2pcs, branching cable 4pcs)
Can accommodate up to 32 drop cables. (option)
Convenient pull-out SC adapter module for drop cable installation.
Compatible with most cable types.
Outer body can be completely removed for 360 degree splice access.
Re-useable grommet sealing open and close easily for adding or removingdrop cables providing efficient cable installation with no mess.
Removable splice tray holder available for convenient aerial splicing.
Compatible with Fujikuras optical splitter trays for the changing needs of
optical networks.
Fusion SpliceConnector
Branching Cable
Drop Cable
Through Fiber
Main CableMain Cable
ApplicationsClosure is suitable for up to 120 single fiber splicing, which can cover
most of the applications in the fiber distribution networks like Fiber
To The Home / Fiber To The Curb (FTTH/FTTC) .
Aerial application is possible with this closure. FSCO-AO haschemical and mechanical resistance for all the aerial application
areas in the fiber networks. In-Line, Butt, Mid-span access, and Taut
Sheath configuration are used.
Structure
FSCO-AOAerial Weathertight Fiber Optic Splice Closures
Packing sealing
Drop cable clampSC Adapter module
Splice tray
Sleeve
(620) (150)
(200)Cable clamp
Splitter tray
TM clamp
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
52
8/12/2019 Fujikura - Optical Components
24/42
Notes
Physical characteristics
Material
Molded plastic
ADC
Stainless steel
Dimension L 620mm x W 150mmx H 200mm
Weight (without kit) 4 kg
Cable diameter
Main cable 8.5 - 28 mm dia.
Branch cable 8.5 - 28 mm dia.
Drop cable 2 x 3 mm
Cable capacity 1 6
Cable ports2 for main cable
4 for branch cable (up to 4 port for Drop Cable optional)
Splice tray capacity Max. 10 trays
Maximum fiber storage
capacity
Single fiber 120 fiber (12 fiber/tray)
4-fiber ribbon 200 fiber (10 ribbon/tray)
No. of optical adapter Max. 16x SC adapter
FSCO-AO
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
A=5mm, f=10Hz, 1,000,000 Cy, No splice case degradation.
No damage.
Cable fixture (bend)
IEC61300-2-37
400mm, 30 bending or max. 500 N, 5Cy/cable. No splice
case degradation. No damage.
Cable torsion
IEC61300-2-5
400mm, Maximum rotation 90/maximum 50 Nm, 5Cy/cable.
No splice case degradation.
Temperature cyclingIEC61300-2-22
-40C-20C-65C, 8h/Cy 100Cy. No splice case degradation Nodamage.
Impact (free drop)
IEC61300-2-12
0.75m @-15C & +45 C. No splice case degradation.
Degrees of protection
(IP Code) IEC 60529
IP54 Protected against splashing water & no effective by dust.
(option :IP55 Wind driven rain proof & no effective by dust.)
Salt mist
IEC61300-2-26
5% NaCl for 5days, without rust. No damage.
Re-entries
IEC61300-2-33
At least 1 thermal cycle to repeat Open & Close the closure
sleeve 10 times. No damage.
Ordering Information
Specification
Tray type and qty
Example :
HD4 : 4 slack trays
Connector type SC8 : 8xSC/UPC adapter w/ 1 drop clamp module
SC16 : 16xSC/UPC adapter w/ 2 drop clamp modules
SCA8 : 8xSC/APC adapter w/ 1 drop clamp module
SCA16 : 16xSC/APC adapter w/ 2 drop clamp modules
Drop cable installable
(with drop cable clamp)
Product Code FSCO-AO / X / Y / D (/CPL)
With Coupler tray
53
8/12/2019 Fujikura - Optical Components
25/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FeaturesCable entrance configuration is In-line, which is suitable for spaceconstrained hand holes (also possible to be used in man-holes, telephone
tunnels and aerial, etc)
Closure adopts band mechanism, which makes dismantling/assembling
easy.Cable entry section can accommodate maximum 4 cables (main cable 2pcs,
branching cable 2pcs)
Supports loose tube cable and slotted core cable.
Fusion Splice
Branching Cable
Branching Cable
Main Cable
ApplicationsClosure is suitable for up to 72 single fiber splicing, which can covermost of the applications in the fiber distribution networks like Fiber
To The Home / Fiber To The Curb (FTTH/FTTC). Underground, aerial,
or pedestal applications are possible with this closure.
StructureFSCO-CB Structure
FSCO-CBSealed Fiber optic splice Closure
CABLE CLAMPEND SEAL TAPE
SLEEVE HALVES
BAND
TRAY (max.6)
TENSION MEMBER CLAMP
A
EARTH TERMINAL
GAS VALVE
AA-A Hinges of tray
126
140
340
A
Lock patr of tray
SLEEVE GASKET
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
54
8/12/2019 Fujikura - Optical Components
26/42
Notes
Physical characteristics
Material
Molded plastic (Sleeve, Splice tray)
Stainless steel (Band), Anti-rusted steel (Connecting bar,
Organiser)
synthetic rubber (Sleeve gasket, end seal tape)
Dimension L 340mm x W 140mm x H 126mm
Weight (without kit) 2 kg
Cable diameter 8 - 21 mm dia.Cable capacity 1 4
Cable ports2 for main cable
2 for branch cable
Splice tray capacity Max. 6 trays
Maximum fiber storage Single fiber 72 fiber (12 fiber/tr ay)
Capacity (BH Tray) 4-fiber r ibbon 120 fiber (5 r ibbon/tray )
Un-reusable parts End seal tape, Sleeve gasket, Sealing washer
FSCO-CB
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
49kPa, A=5mm, f=10Hz, 1,000,000 Cy,
No damage, No leakage.
Cable fixture (bend)
IEC61300-2-37
49kPa, 90 bending radius 6D, 6Cy.
No damage, No leakage.
Cable torsion
IEC61300-2-5
49kPa, 400mm, 90 degree, -15C and 45C, 5Cy.
No damage, No leakage.
Cable axial tensionIEC61300-2-4
49kPa, D/45 x 1000N (Max.1000N), 1hrNo leakage
Temperature cycling
IEC61300-2-22
-20C ~ 60C, 8h/Cy 100Cy. Then fill 49kPa air-pressure,
No leakage.
Impact
IEC61300-2-12
0.5kg, 0.3m @-10C.
No damage, No splice case degradation.
Immersion
IEC61300-2-23
Water depth 5m, 7days,
No water intrusion.
Air t ightness
IEC61300-2-38
49kPa@Room temperature, 15min.
No leakage.
Degrees of protection
(IP code) IEC60529
IP67 : Water proof and No effective by duct
Compression
IEC61300-2-10
1000N, 25cm2, 10min, -15C and 45C
No leakage
Chemical Resistance
IEC61300-2-34
pH2, pH12 for 5 days.
No leakage, Visual appearance.
Rust resistance
IEC61300-2-26
Salt spray 5% NaCl for 5days, No rust
Ordering Information
Specifications
Tray type BH or BL
Number of slack Tray (1~6)
Presence of gas valve and
earth terminal
(Yes:2 No:1)
Product Code FSCO-CB / ** / X / Y / Z /
Cable size
Cable diameter D (mm)The size of cable clamp
and sealing washer
8 D 11 S
11 D 16 M
16 D 21 L
End packing E
Presence of optional parts(Yes:2 No:1)
Option
C sleeve Fro FRP tension member use. Please order when Non-metallic cable installation
Re-entry kit End seal tape 4pcs, Sleeve gasket 2pcs
Cable kit Size S, M, L for additional branching cable
55
8/12/2019 Fujikura - Optical Components
27/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FeaturesCable entry section is single-sided pot structure which is suitable for spaceconstrained hand holes (also possible to be used in man-holes, telephone
tunnels etc)
Closure adopts hinge/buckle mechanism which makes dismantling/
assembling easyCable entry section can accommodate maximum 8 cables (main cable 2pcs,
branching cable 6pcs)
Can accommodate up to 32 drop cables. (option)
Supports loose tube cable, slotted core cable, drop cable.
Suitable for application in areas with limited space applications, too. (handholes)
Applicable for all networks. FTTH /FTTC solutions.
Fully mechanical design, fiber reinforced plastic or equivalent
Recommendation of life span for 15 to 20 years (depends on environment)
Concept of separate cable entries system
Laser caution signs provided on cover of the top traySize of splice tray smaller footprint than 5"x12"
360deg access permits complete access to all wirework and equipment
sleeve attaches securely to the base using a self-locking 216-hex head
bolt lock or equivalent
Main CableThrough Fiber
Branching Cable
Drop Cable
Field installableconnectorFusion Splice
ApplicationsClosure is suitable for up to 192 single fiber splicing, which can cover
most of the applications in the fiber distribution networks like FiberTo The Home / Fiber To The Curb (FTTH/FTTC) .Underground, aerial,
or pedestal applications are possible with this closure.
FSCO-HHS has chemical and mechanical resistance for all the
application areas in the fiber networks. Only butt configuration use.
StructureFSCO-HHS
FSCO-HHS-CC/[ ]SP FSCO-HHS-FS/[ ]SP
FSCO-HHSSealed Fiber optic splice Closure
Band
End plate
Drop cable clamp
SC Adapter
Splice tray
214
278
214 316.3
278
316.3
TM clamp
Sleeve
Cable clamp
Band
End plate
Drop cable clamp
Splice tray
TM clamp
Sleeve
Cable clamp
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
56
8/12/2019 Fujikura - Optical Components
28/42
Notes
Physical characteristics
Material
Molded plastic
Coated ADC as stainless equivalent
Stainless steel
EPDM
Dimension W 278mm x D 214mm x H 316mm
Weight (without kit) 4 kg
Cable diameterMain cable 9 - 24 mm dia.Branch cab le 8 - 16 mm d ia.
Drop cable 2 x 3 mm
Cable ports
2 for main cable
1 for branch cable
2 for Drop Cable
Splice tray capacity 2 trays
Maximum fiber storage
capacity
Single fiber 24 fiber / tray
4-fiber ribbon 40 fiber (10 ribbons) / tray
Splitter 1 x 4 : 4pcs or 1 x 8 :2pcs or 1 x 16 : 1pcs
with max. 4 splices
No. of optical adapter Max.16 x SC adapter
FSCO-HHS
Technical characteristics ITU-T L.13 complied
Vibration 40kPa A=5mm, f=10Hz, 1,000,000 Cy, No splice case
degradation. No leakage.
Cable bend40kPa, 300mm, 90degree, 6Cy. No splice case
degradation. No leakage.
Cable torsion 1000mm, 90 degree, 10Cy. No splice case degradation.
Rust resistance Salt spray for 30days, without rust
Temperature cycling -20C-20C-60C, 8h/Cy 100Cy. Then fill 40kPa air-pressure,without leakage.
Impact 0.5kg, 0.3m @-10C. No splice case degradation.
Immersion Water depth 4m, 24hrs, without water intrusion.
Air t ightness40kPa@Room temperature, 5min. No splice case
degradation. No leakage. IP67
Compression 980N, 1min, No splice case degradation.
Chemical Resistance pH2, pH12 for 5 days. Without corrosion.
Re-entryRepeat Open & Close the closure 25times.
No greater than 0.1dB optical attenuation change
Ordering Information
Specification
Model type
CC : Connector connecting type
FS : Fusion Splice type
Product Code FSCO-HHS- X1 / X2
Splitter module 0SP : No splitter inside(SC adaptor not equipped)
4SP : 1x4 splitter module inside(with 4pcs SC adaptor)
8SP : 1x8 splitter module inside(with 8pcs SC adaptor)
16SP : 1x16 splitter module inside (with 16pcs SC adaptor)
b1
b2
b3
b4
a1
a2
a3
a4
a1,b1 : for Main cable onlyb2,b31 : for Drop cable onlyb4 : for Branch cable onlya2,a3,a4 : No entty
Cable ently position
C sleeve Fro FRP tension member use. Please order when Non-metallic cable installation
Branch cable kit 1 set/1 cable for 8 - 6 mm dia.
Branch cable kit 1 set/1 cable for 16 - 19 mm dia.
Drop cable kit 1 set/8 cables for drop cables
Main cable end plate 1 pcs Necessary to entry one main cable only
Option
57
8/12/2019 Fujikura - Optical Components
29/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FeaturesCable entry section is single-sided dome structure which is suitable forspace constrained hand holes (also possible to be used in man-holes,
telephone tunnels etc).
Closure adopts hinge/buckle mechanism which makes dismantling/
assembling easy.Cable entry section can accommodate maximum 6 cables (main cable 2pcs,
branching cable 4pcs).
Supports both loose tube cables and slotted core cables.
Suitable for use in limited space areas such as hand holes
Applicable for all networks. FTTH /FTTC solutions.
Fully mechanical design, fiber reinforced plastic
Recommendation of life span for 15 to 20 years (depends on environment)
Concept of separate cable entries system
Laser caution signs provided on cover of the top tray
360-deg access permits complete access to all wirework and equipment
Main Cable
Main Cable
Through Fiber
Branching Cable
Fusion Splice
ApplicationsClosure is suitable for up to 192C (4-ribbon) fiber splicing,which can accommodate the requirements of most fiber
distribution networks such as Fiber To The Home/Fiber To
The Curb (FTTH/FTTC). Suitable for underground, aerial and
pedestal installation.
FSCO-L5BR has chemical and mechanical resistance for allthe application areas in the fiber networks.
Structure
FSCO-L5BRSealed Fiber Optic Splice Closure
194 230
Cover
Tray
Tension member clamp Cable clamp
Band
Valve
Cover gasket
435
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
58
8/12/2019 Fujikura - Optical Components
30/42
Notes
FSCO-L5BR
Ordering Information
Specifications
Type of fiber capacity :
12C, 24C, 36C, 48C, 96C,
144C, 192C
Type of Closure : BR
(BR : Heat shrink tube type)
Number of holes cable :
5 holes
Product Code FSCO - L5 BR / Y
Physical characteristics
Material
Molded plastic (Cover, Splice tray, Tray base, Pass case, End
plate, Cable clamping )
Stainless steel (Tension member clamp),
Synthetic rubber (Cover gasket, Valve gasket )
Dimension L 435mm x D230mm
Weight (without kit) Approx 3.7 kg
Cable diameter 8 17.5 mm dia.(Main cable:12-17.5 mm, Branch cable:8-17.5mm)
Cable capacity Max. 6 cables
Cable ports1 oval port for 2x main cables
4 round ports for branch cables
Splice tray capacity Max. 5 trays
Maximum fiber storageCapacity
Single fiber 120 fibers (24 fiber/tray)
4-fiber ribbon 200 fibers (10 ribbon /tray)
Un-reusable parts Heat shrink tube, Branching clip
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
49kPa, A=5mm, f=10Hz, 1,000,000 Cy,
No damage, No leakage.
Cable fixture (bend)
IEC61300-2-37
49kPa, 90bending radius 6D, 6Cy.No damage, No leakage.
Cable torsion
IEC61300-2-5
49kPa, 400mm, 90 degree, -15C and 45C, 5Cy.
No damage, No leakage.
Cable axial tensionIEC61300-2-4
49kPa, D/45 x 1000N (Max.1000N), 1hrNo leakage
Temperature cycling
IEC61300-2-22
-20C ~ 60C, 8h/Cy 100Cy. Then fill 49kPa air-pressure,
No leakage.
Impact
IEC61300-2-12
0.5kg, 0.3m @-10C.
No damage, No splice case degradation.
Immersion
IEC61300-2-23
Water depth 5m, 7days,
No water intrusion.
Air t ightness
IEC61300-2-38
49kPa@Room temperature, 15min.
No leakage.
Degrees of protection
(IP code) IEC60529IP67 : Water proof and No effective by duct
Compression
IEC61300-2-10
1000N, 25cm2, 10min, -15C and 45C
No leakage
Chemical Resistance
IEC61300-2-34
pH2, pH12 for 5 days.
No leakage, Visual appearance.
Rust resistance
IEC61300-2-26
Salt spray 5% NaCl for 5days,
No rust
59
8/12/2019 Fujikura - Optical Components
31/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
Optical connectors and cable assemblies
SC ConnectorOptical connectors
MU Connector
FC Connector
LC Connector
MTRJ Connector
MPO/LIGHTRAY MPX Connector
Item Content
Fiber TypeSingle Mode Multi ModeSM10/125 G50/125DSM8/125 G62.5/125
Insertion Loss(with master cord) PC polish Typical 0.2 dB 0.3dBUltra PC polish (UPC) -Return Loss Ultra PC polish (UPC) Typical 55 dB -
Suitable Cord Type f2 cord, f0.9 fiberConformity Standard IEC61754-6
( ) Available for "premium grade" with excellent inser tion loss and return loss.
( ) Please enquire on the return loss for multi-mode fiber if required.
Item Content
Fiber TypeSingle Mode Multi ModeSM10/125 G50/125DSM8/125 G62.5/125
Connector Loss
(with master cord)
PC polishTypical 0.2 dB
0.3dBUltra PC polish (UPC) -
Angled PC polish (APC) -
Return LossUltra PC polish (UPC) Typical 55 dB -
Angled PC polish (APC) 60dB -Suitable Cord Type f2 cord, f3 cord, f0.9 fiber
Conformity Standard JIS C5970(F01), IEC61754-13
( ) Available for "premium grade" with excellent inser tion loss and return loss.
( ) Please enquire on the return loss for multi-mode fiber if required.
Tight-Buffered Fiber Type
Item Content
Fiber TypeSingle Mode Multi ModeSM10/125 G50/125DSM8/125 G62.5/125
Insertion Loss
(with master cord)
PC polishTypical 0.2 dB
0.3dBUltra PC polish (UPC) -
Angled PC polish (APC) -
Return LossUltra PC polish (UPC) Typical 55 dB -
Angled PC polish (APC) 60 dB -Suitable Cord Type f2 cord, f3 cord, f0.9 fiber
Conformity Standard IEC61754-4
( ) Available for "premium grade" with excellent inser tion loss and return loss.
( ) Please enquire on the return loss for multi-mode fiber if required.
Item Content
Fiber TypeSingle Mode Multi ModeSM10/125 G50/125DSM8/125 G62.5/125
Insertion Loss
(with master cord)
PC polishTypical 0.2 dB
0.3dBUltra PC polish (UPC) -
Angled PC polish (APC) -
Return LossUltra PC polish ( UPC) Typical 55 dB
Angled PC polish (APC) 60 dBSuitable Cord Type f2 cord, f0.9 fiber
Conformity Standard TIA/EIA-604-10, IEC61754-20
( ) Available for "premium grade" with excellent inser tion loss and return loss.
( ) Please enquire on the return loss for multi-mode fiber if required.
Tight-Buffered Fiber Type
Item Content
Fiber Type
Single Mode Multi Mode
SM10/125 G50/125
DSM8/125 G62.5/125
Insertion LossPC polish
0.7dB 0.4dB
Return Loss 26dB -
Suitable Cord Type f2 zipcord, f2.8 dual-link cableConformity Standard TIA/EIA-604-12, IEC61754-18
MTRJF: Without guide pin MTRJM: With guide pin
( ) Please enquire on the return loss for multi-mode fiber if required.Dual-Link Cable Type
Item Content
Fiber Type Single Mode Multi Mode
Connector LossStandard Grade 1dB 0.5dBLow-Loss Grade 0.35dB -
Return Loss 55dB -Suitable Cord Type Fiber ribbon, Ribbon cord
Conformity Standard MPO: IEC61754-7
MPOF, MPXF: Without guide pin MPOM, MPXM: With guide pin
Singlemode type meets Telcordia GR-1435-CORE
( ) MPX: LIGHTRAY MPX is a trademark of The Whitaker Corporation
(
) Please enquire on the return loss for multi-mode fiber if required.MPX connector
Cord Type
Cord Type
Cord Type
MPO connector
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
60
8/12/2019 Fujikura - Optical Components
32/42
Notes
Optical connectors and cable assemblies
Pigtails, Simplex and Duplex Cable AssembliesCompatible with SC, FC and other types of single fiber connectors.
Available in various cord sizes 0.9 (TBF), 1.6, 2 and 3 mm.
1 3 3
4
2 5 6 7 1
Lm
Optical Connector
Name
Differentiate Between
Single/Double Ended
Termination and Fiber
Type (SM or GI)
Polishing Method Product Length Fiber Type Fiber Size Cord Size
Shows the connector
type
Please indicate clearly
if different connectors
are required to be
terminated at both
ends (ex. FFC/FSC)
* Single-ended: 1
* Double-ended: 2
* GI:P
* SM:PS
* Spherical: PC
* Ultra PC:UPC
* Angled PC:APC
Please indicate clearly
if polishing is different
at both ends (ex. APC
/UPC)
* Unit in meter
* Tolerance
L 1m +10cm, -0
1m < L 10m +10%, -0
10m < L 50m +1m, -0
L > 50m +2%,-0
Cord
* GI:GC (Orange)
* SM: SMC (Yellow)
* DSM: DSMC (Yellow or
Orange)
Tight-Buffered Fiber
* GI:G
* SM:SM
* DSM:DSM
Please indicate core
diameter (mode field
diameter)/clad diameter
* f2 simplex: S
* f3 simplex: Leave blank.
* f2 zipcord: 2SR
* f3 zipcord: 2R
* f1.6 simplex: SS
* f1.6 zipcord: 2SSR
Please refer to the Application Table for the relevant fibers and cords for each type of connector.
Shape and color of connector boot may vary depending on the type of fiber/cord and polishing method.
Please enquire on flame retardant type of cords.
Connector
Single Mode (SM/DSM) Multi-Mode
Polishing Method Suitable TBF/cord diameter Suitable CordPolishing
MethodSuitable TBF/cord diameter Suitable Cord
PC UPC APC 0.9 1.6 2 3 Simplex Duplex PC 0.9 1.6 2 3 Simplex Duplex
SC
FC
MU
LC
MTRJF
MTRJM
DXSC
DXMU
DXLC
F FC 2PSUPC LM SMC10/125S
Product Code Interpretation
Application Table
Patchcords compliant with ISO/IEC 11801 and TIA/EIA-568-C.3 available for customer premises and
commercial building telecommunications cabling.
Simplex and zipcord cables meet TIA/EIA 568-C.3, Telcordia GR-409-CORE and Directive 2002/95/EC(RoHS) and Plenum, Riser and OFNR-listed LSZH grade jackets available.
LSZH meets the requirement of IEC 61034-1, 61034-2, 60332-1-1,60332-1-2, 60754-1 and 60754-2.
OS1, OS2, bend-insensitive FutureGuide-SR15E (ITU-T G.657.A1), FutureGuide-BIS-B (ITU-T G.657.A2)
and ITU-T G.657.B3 fiber for singlemode applications and OM1, OM2, OM3 and OM4 for multimodeapplications available as options.
3 or 4 mm dia. ultra-flexible cables (MageTsuyo) with FutureGuide-BIS-B (ITU-T G.657.A2) for FTTH
cabling available as options.
61
8/12/2019 Fujikura - Optical Components
33/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FeaturesMechanical splice connection makes use of mechanical splice unit
where 2 fibers are first inserted into the unit. The fibers are next
aligned and then held in position by clamping parts.
Fast and Easy splicing of 250 or 900um SM/MM fibers.
Power source not required, all necessary tools are provided in thestandard tool kit.
Much faster compared to fusion splicing method
Specifications
StructureMechanical splice connection is done by using the mechanical splice
shown in Figure 1. Fibers are set to the V-groove of the mechanical
splice. The fibers are hold in place by clamping with the clamping
parts. Index matching gel is added to the center of the mechanical
splice ( at the supposed connection point of the two fibers) to ensuregood insertion and return loss.
Figure 2 and Figure 3 show the inner structure of the mechanical
splice. Both the 0.25mm section and 0.125mm (bare fiber) section of
the fiber are being clamped and held in position.Therefore, to ensure
good connection, both the fiber stripping length and the fibercleaved length must be controlled within specifications.
Mechanical Splice UnitMechanical Splice
Single fiber Mechanical Splice
Mechanical splice
Wedge grooves
U-shape sleeve
Optical fibers
Figure 1
Type Mechanical Splice Unit Remark
Product Code FMSEZ-025/09
Appl icat ion Dia.0.25mm s ingle fiber or D ia .0.9mm single fiber Cladding : 0.125mm Except Nylon coat ing fibers
Appl icable fiber diameter range Dia.0.235mm to 0.265mm , Dia. 0.85mm to 0.95mm ITU-T compliance
Size L40 x W4 x H4 (mm)
Connection Loss Average < 0.1dB
Return Loss 40dB
Fiber Adhesion Force < 3N (Connection Loss change < 0.2dB)
Required Tools Single fiber MS/EZ Assembly tool
Clamping parts (3 sections)
Index matching gel
Optical fiber (outercoat stripped,
0.125mm outer diameter)
Optical fiber
(0.25mm outer
diameter)
V-groove substr ate
Clamping part
Optical fiber
U-shape sleeve
Used to clamp the
clamping parts and
V-groove substr ate
together
Wedge
V-groove substr ate
When wedge is inserted
into the mechanical splice,
the space at the V-groove
substrate is enlarged, allowing
fiber to be inserted into
the mechanical splice.
0.125mm bare fiber section
0.125mm bare fiber
(no outercoat:
fiber glass section)Connection point
0.25mm fiber section
Optical fiber holder
0.25mm fiber
inserted section
Inner structure of
mechanical splice
Figure 2-1 Figure 2-2 Figure 3
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
62
8/12/2019 Fujikura - Optical Components
34/42
Notes
Single Fiber MS/EZ Assembly tool
Assembly Tool
FeaturesMS/EZ assembly tool for f0.25mm single optical fiber.
Easier MS/EZ assembly than one with existing tool.
MS/EZ assembly tool for FMSEZ-025.
No electric power is required and assembly can be done quickly.
Suitable for FTTH drop cable solution.
MS/EZ assembly kit is also available.
MS/EZ Assembly toolMechanical Splice
1 2 3 4 5
Item Model No. Quantity Remarks
1 MS/EZ Assembly Tool FMSECO-TL2-EZ 1ea
2 Mechanical StripperF FMSECO-MSTR025 1ea
3 Single Fiber HolderF FMSECO-FH05/025 10ea4 Spacer for Mechanical Splice SpacerF FMSECO-SP-C2 2ea
5 Alcohol Bot tle FMSEZ-ALC 1ea
Wiper - 1set
Instruction Manual - 1set
6 Carrying Case - 1set
7 Fiber Cleaver CT-30 - Option
8 Micro Stripper (f0.9) MS1-08S-40-FS - Option
9 Single Fiber HolderF(f0.9) (Instruction Manual Included) FMSECO-FH09 - Option
Single fiber MS/EZ assembly tool (for f250um fiber) is also available.
FMSEC0EZ-KIT025C-10 (without Fiber Cleaver)
FMSEC0EZ-KIT025C-11 (with Fiber Cleaver)
6 7 8 9
63
8/12/2019 Fujikura - Optical Components
35/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
Package Information250um Fiber holder : 1pcs/10connectors
250um Fiber insert guide : 1pcs/10connectors
900um Fiber Holder : Order separately
1pcs of spacer/10connectors
1pcs of marker/10 connectors (only for APC interface connector)
FAST-Connector (UNI) Series (for 250um, 900um fiber)
FAST-Connector
Before Assemble
FeaturesFAST-SC-UNI, FAST-LC-UNI has own design to clamp 250um and
900um coated fibers. Both are fully compatible with the standard SC,
LC connectors and demonstrate the performance combining SC, LC
connectors and Mechanical Splices.
Fujikura has greatly simplified process of joining two fibers, thereforeproviding significant support for our customers in the construction of FTTH
network. Fujikura FAST connector is a series of field-installable connectors,
which require no polishing. Unlike conventional field-installable connectors,
FAST connector series do not employ assembling tool but incorporate its
own pre-assembled wedge launcher. The pre-assembled wedge launcher is a
disposal part af ter installing fiber. Fujikura FAST connector uses a mechanism
of Push-pull-wedge, which has been introduced by Fujikuras Mechanical
Splices. As the Push-pull-wedge mechanism achieves clamping both bare
fiber part and coating part, this clamping mechanism enhances strength
against fiber twist.
Item Content
Applicab le fiber diameter240 ~ 265 um (for 250um fiber),
850 ~ 950 um (for 900um fiber)
Fiber Polishing Method UPC Polish, APC Polish
Connection Loss
(wrt master)
< 0.5dB (Singlemode)
< 0.6dB (Singlemode APC Polish)
< 0.4dB (Multimode)
Return Loss
> 45dB (SM fiber UPC polish)
> 65dB (SM fiber APC polish / When use with Angled cleaver)
> 50dB (SM fiber APC polish / When use with Flat cleaver)
Working temperature-40C ~ 75 C (for 250um fiber)
Base on fiber spec (for 900um fiber)
Specification
Specifications
TypeProduct Code
FAST-SC FAST-LC FAST-ST
Singlemode UPC Polish FAST-SC-SM-UNI/00-BL/BK FAST-LC-SM-UNI/00-BL/BK FAST-ST-SM-UNI/00-BL/BK
Singlemode APC Polish FAST-SC-APC-SM-UNI/00 - -
50/125 Multimode FAST-SC-GI5-UNI/00-BK/BK FAST-LC-GI5-UNI/00-BK/BK FAST-ST-GI5-UNI/00-BK/BK
62.5/125 Multimode FAST-SC-GI6-UNI/00-BG/BK FAST-LC-GI6-UNI/00-BG/BK FAST-ST-GI6-UNI/00-BG/BK
MM10G FAST-SC-10G-UNI/00-AQ/BK FAST-LC-10G-UNI/00-AQ/BK FAST-ST-10G-UNI/00-AQ/BK
Interior Structure Cross-sectional View
Polished Optical fiber is pre-affixed at the tip of the connector and
stripped fiber is cleaved and aligned until it touches the built-in fiber,
where connection is done via mechanical splice method
Pre-installed FiberRefractive
Index Matching GelInserted Fiber
Stripped Fiber
Securing Clamp
Bare FiberSecuring Clamp
Ferrule
Wedge
Fiber
250um fiber
insert guide
250um fiber
holder
Marker900um fiber
insert guide
After Assemble
Assembly Flow
1. Prepare fiber 3. Remove connector unit from
the wedge launcher
2. Insert fiber into connector body
and confirm fiber bend
4. Insert the boots
Approx. 10mm
Coating part Glass
64
8/12/2019 Fujikura - Optical Components
36/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FAST-Connector Cord series (for 2mm & 3mm)
FAST-Connector
Before Assemble
FeaturesFAST-SC-09/CO FAST-LC-09/CO have own design to clamp 2mm,
and 3mm cord. Both are fully compatible with the standard SC, LC
connectors. Therefore, FAST-SC, FAST-LC demonstrates the
performance combining SC, LC connectors and Mechanical Splices.
Item Content
Applicab le Cord Diamer f2mm (for 2mm cord), f3mm (for 3mm cord)
Fiber Polishing Method UPC Polish, APC Polish
Connection Loss
(wrt master)
< 0.5dB (Singlemode)
< 0.6dB (Singlemode APC Polish)
< 0.4dB (Multimode)
Return Loss
> 45dB (SM fiber UPC polish)
> 65dB (SM fiber APC polish / When use with Angled cleaver)
> 50dB (SM fiber APC plish / When use with Flat cleaver)Fiber Retention Force Cord :
8/12/2019 Fujikura - Optical Components
37/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
FAST-Connector (for Drop/Indoor Cable/Low Friction Indoor Cable)
FAST-Connector
Before Assemble
FeaturesFAST-SC-GT type has own design to clamp drop cable or indoor
cable and low friction indoor cable. FAST-SC is fully compatible with
the standard SC connectors. Therefore, FAST-SC demonstrates the
performance combining both SC connectors and MechanicalSplices.
Item Content
Applicab le Cable Diamer3.1 0.2mm x 2.0 0.2mm (Drop/Indoor Cable)
2.0 0.1mm x 1.6 0.1mm (Low Friction Indoor Cab le)
Fiber Polishing Method UPC Polish, APC Polish
Connection Loss
wrt master)
< 0.5dB (Singlemode)
< 0.6dB (Singlemode APC Polish)
< 0.4dB (Multimode)
Return Loss> 45dB (SM fiber UPC polish)> 65dB (SM fiber APC polish / When use with Angled cleaver)
> 50dB (SM fiber APC plish / When use with Flat cleaver)
Fiber Retention Force > 20N (
8/12/2019 Fujikura - Optical Components
38/42
No. Name Model PurposeKIT
(A)
KIT
(B )
KIT
(C)
KIT
(D)
KIT
(E )
1 Optical fiber holder 025 FMSECO-FH05/025 To assemble FAST-SC for 250um fiber
2 Cable Holder - To assemble FAST-SC(GT)
3 Mechan ical Str ipper 025 FMSECO-MSTR025 To str ip 250um fiber
4 Micro Stripper 09 MS1-08S-40-FS To strip 900um fiber
5 Alcohol Container FMSEZ-ALC -
6 Cotton Pad - -
7 High Precision Cleaver CT-30 + HBA01 Flat Cleaving
8 Fiber Plates AD-30A To adjust bare fiber length Option
9 Spacer FMSECO-SP-C2 To adjust bare fiber length
10 250um fiber insert tool - To assemble FAST-SC for 250um fiber
11 Carrying Case - -
12 Cordage Assembly tool FAST-SC-KIT-CO To assemble cordage
13 f2mm Cable Clamp FAST-SC-KIT-CO To assemble f2mm cordage
14 f3mm Cable Clamp FAST-SC-KIT-CO To assemble f3mm cordage
15 Angled Cleaver CT-11Angled Cleaving
To get high return loss
* Kit (A) ; FAST-SC-KIT025DR-10, Kit( B) ; FAST-SC-KIT025DR-11 , Ki t(C) ; FAST-SC-KIT/ALL-10, Kit(D) ; FAST-SC-KIT/ALL-11,
KIT(E) ; FAST-SC/APC-KIT/ALL-11
Notes
FeaturesIndustry standard fiber preparation tools
Compact design, flexible but rugged case
Complete instructions provided
The FAST Connector Assembly Tool Kit provides all the necessary installation tools.
FAST-Connector
FAST-Connector Assembly Tools
Mechanical Splice
1 2 3 4 5
7 8 9 10 11
12 13 14 15
67
8/12/2019 Fujikura - Optical Components
39/42
Latest information also available on the internet URL :www.fujikura.co.jp
For Enquiry Email : [email protected]
OPTICAL COMPONENTSOPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
FeaturesFuseConnectTM with factory pre-polished ferrule, utilizes fusionsplicer to terminate the connector in the field. Similar to Fujikura
Field Installable connector series, field-termination process
eliminates polishing, adhesives, and crimping in the field.
Fusion splice addresses return loss concerns present in analogoptical networks. This advanced process yields true APC
performance of >65dB return loss in an SC/APC configuration.
The unique and innovative design of Fuse Connect eliminates the
complicated crimping operation. The simplified field installation
minimizes the potential for operator error.
ApplicationConnectorization in :
RF-overlay FTTP network
Cable TV backbone network
Outside plant
MDU FTTP Cabling
Central office connector replacement.
Data center installation
Patch cord customization in the field
FuseConnectTMFusion-spliced, field-terminated connector
UPC
APC
FuseConnect MPO Connector
Interior Structure
Ferrule Fusion Splice point
Optical fiber cableSteal rodProtection SleeveEmbedded fiber
SpecificationItem Content
Applicable fiber type 900um, 2mm, 3mm j3mm cordage (12c), Ribbon fiber (12c)
Connector type SC or LC MPO (Male or Female)
Polishing UPC or APC n/a
Connection Loss (wrt master)< 0.3dB (Singlemode) < 0.75 dB (Single mode)
< 0.3dB (Multimode) < 0.50 dB (Multimode)
Return Loss
> 65dB (SM fiber APC polish) > 55 dB (Single mode)
> 55dB (SM fiber UPC polish) n/a (Multimode)
> 30dB (MM UPC polish) -
Working temperature -40 C ~ 75 C
Ordering Information (SC, LC)Type SC 900um fiber SC 2mm code / SC 3mm code LC 900um fiber LC 2mm code LC 3mm code
SM UPC Polish FuseConnect-SC-SF-SM-09 FuseConnect-SC-SF-SM-20/30 FuseConnect-LC-SF-SM-09 FuseConnect-LC-SF-SM-20 FuseConnect-LC-SF-SM-30SM APC Polish FuseConnect-SC-SF-APC-09 FuseConnect-SC-SF-APC-20/30 FuseConnect-LC-SF-APC-09 FuseConnect-LC-SF-APC-20 FuseConnect-LC-SF-APC-30
MM(50/125) UPC Polish FuseConnect-SC-SF-GI5-09 FuseConnect-SC-SF-GI5-20/30