PCR0808 Dealer Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi , Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/ Warning Daikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a particular country. Prior to purchase, please therefore confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Specifications, designs and other content appearing in this brochure are current as of February 2008 but subject to change without notice.  All rights reserved Printed in Japan 02/08/003 Y.K., P.C. c 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install  the outdoor unit close to the sea shore, contact your local distributor. Cautions on product corrosion ISO 140 01 is th e sta nd arddefi ne d by the Interna tional Organ ization for Standard ization (ISO) relatin g to enviro nmen tal manag eme nt systems. Our group has been acknow ledge d by an intern ationa lly accredite d complia nce organi sation as having an approp riate programme of enviro nmen tal protect ion proced ures and activitie s to mee t the require ment s of ISO 14001. Abou tI SO14001 ISO 9001 is a pla nt certifica tio n syste m define d by the Internat ional Organ izatio n for Standard ization (ISO) relatin g to qualit y assura nce . ISO 9001 cert ifica tion cove rs qua lity assura nce aspe cts relatedto the design, developm ent, manufacture, installati on, and supple ment ary service” of product s manufa ctured at the plant. Abou t ISO9001 JMI-0107 JQA-1452
10

FTKD25-71

Aug 07, 2018

Download

Documents

binhjuki
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: FTKD25-71

8/21/2019 FTKD25-71

http://slidepdf.com/reader/full/ftkd25-71 1/10

PCR0808

DealerHead Office:

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:

JR Shinagawa East Bldg., 2-18-1, Konan,

Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global_ac/ 

Warning Daikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the

world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a

particular country. Prior to purchase, please therefore confirm with your local authorised importer,

distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for

use, in the region where the product will be used. This statement does not purport to exclude, restrict

or modify the application of any local legislation.

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.

Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or

contractor to install those parts and accessories. Use of unauthorised parts and accessories or

improper installation of parts and accessories can result in water or refrigerant leakage, electrical

shock, fire or explosion.

Read the User’s Manual carefully before using this product. The User’s Manual provides important

safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Specifications, designs and other content appearing in this brochure are current as of February 2008 but subject to change without notice.

  All rights reservedPrinted in Japan 02/08/003 Y.K., P.C.

c

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install  the outdoor unit close to the sea shore, contact your local distributor.

Cautions on product corrosion

ISO 14001 is the standarddefined by theInternational Organization for Standardization(ISO) relating to environmental managementsystems. Our group has been acknowledgedby an internationally accredited complianceorganisation as having an appropriateprogramme of environmental protectionprocedures and activities to meet therequirements of ISO 14001.

AboutI SO14001

ISO 9001 is a plant certification systemdefined by the International Organization forStandardization (ISO) relating to qualityassurance. ISO 9001 certification coversquality assurance aspects relatedto the“ design, development, manufacture,installation, and supplementary service” of products manufactured at the plant.

About ISO9001

JMI-0107 JQA-1452

Page 2: FTKD25-71

8/21/2019 FTKD25-71

http://slidepdf.com/reader/full/ftkd25-71 2/10

2 3

Page 3: FTKD25-71

8/21/2019 FTKD25-71

http://slidepdf.com/reader/full/ftkd25-71 3/10

4 5

GOODDESIGN

AWARD2004

INJAPAN

GOODDESIGN

AWARD2004

INJ APAN

FTKE42G and FTKD50/60/71FFTKE25/35G

RKE25/35G

RKE42G RKD50/60/71BThe Good Design Award is sponsored bythe Japan Industrial Design PromotionOrganization to promote excellence incommercial product design.

FTKE25GV1 / RKE25GV12.5 (1.6-3.2) kW

  8,500 (5,450-10,900) Btu/h

FTKE35GV1 / RKE35GV13.2 (1.6-4.0) kW

  10,900 (5,450-13,600) Btu/h

FTKE42GV1 / RKE42GV1  4.2 (2.0-5.0) kW  14,300 (6,800-17,100) Btu/h

FTKD50FVM / RKD50BVM  5.2 (1.5-5.9) kW  17,700 (5,100-20,100) Btu/h

FTKD60FVM / RKD60BVM

  6.2 (1.5-6.5) kW  21,200 (5,100-22,200) Btu/h

FTKD71FVM / RKD71BVM  7.1 (2.1-7.6) kW  24,200 (7,200-25,900) Btu/h

Page 4: FTKD25-71

8/21/2019 FTKD25-71

http://slidepdf.com/reader/full/ftkd25-71 4/10

6

Powersource

Raise frequency

Lower frequency Low-speed rotation

High-speed rotation

Compressor

Compressor

Inverter Power Control

Non-inverter type air conditioner

Highcapacity

Lowcapacity

Powersource

Constant speedrotation

Fixed capacity

50

0 30 60 90 120

60

70

80

90

Rotational speed (rps)

AC motor

ConventionalDC motor

Reluctance DC motor

   M  o   t  o  r  e   f   f   i  c   i  e  n  c  y   (   %   )

Small load Large loadL ow ca pa ci ty H ig h ca pa ci ty

More than 20%

Inverter Advantages Compared to Non-Inverter

PAM Control

What Is DC Inverter?Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiencythan an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor

that is equipped with high-power neodymium magnets, which enable even greater efficiency, is called a Reluctance

DC motor.Inverter air conditioners are able to vary their operating capacity. Non-inverter air conditioners canonly operate at a fixed capacity.

Variable Capacity Operation

Energy-Saving Technological Features

Swing Compressor

Reluctance DC Motor for Compressor

Daikin DC Inverter models areequipped with the Reluctance DC

motor for compressor. The Reluctance

DC motor uses 2 different types of

torque, neodymium magnet*1 andreluctance torque*2. This motor can

save energy because it generates

more power with a smaller electricpower than an AC or conventional DC

motor. It is more efficient at the low

frequencies most commonly used by air conditioners,*3 improving efficiency by approximately 20%.

DC Motor for FanThe DC motor allows fine rotation

control, which reduces energy

consumption. The motor alsoprovides improvements in

operational efficiency of up to 40%,compared to an AC motor. Theseimprovements are particularly

noticeable in the low-speed range.

*1. A neodymium magnet is approximately 10 times stronger than a standardferrite magnet.

*2. The torque created by the change in power between the iron and magnetparts.

*3. The frequency range used by air conditioners during periods of stableoperation. This is the range in which air conditioners operate for thelongest periods.

The swing compressor canreduce operational vibration andsound because its piston movessmoothly inside the compressor.

Swing bush

Integral piston ofblade and roller

Refrigerant gas

This was the first scrollcompressor to be equippedwith the Reluctance DCmotor in commercial-use airconditioners. The Institute ofElectrical Engineers of Japanpresented the award in 1998.

This marked the developmentof a high-performance swingcompressor that wascompatible with alternativefluorocarbons. The prize waspresented in 1997.

Neodymium magnets are usedin the pink-coloured area.

Reluctance DC motor

Swing compressor

Thanks to its smoothrotation, the swing

compressor decreases

friction and vibration. Italso prevents the leakage

of refrigerant gas during

compression. Theseadvantages provide quiet

and efficient operation.

Model

COP

FTKE25/35/42G

3.35

FTKD50F

3.25

FTKD60F

2.95

FTKD71F

2.78

PAM (Pulse Amplitude Modulation)

control reduces energy loss by

controlling how often the converterswitches on and off.

Energy Saving

After the indoor temperature

approaches the set temperature,

Inverter Control adjusts to low

capacity operation to maintain this

temperature. This makes inverter

models more energy-saving than

non-inverter models, which must

repeatedly start or stop their

compressors to maintain the room

temperature.

Inverters are devices that are able to vary their operating capacity by adjusting frequency. Inverter air

conditioners can vary their heating/cooling capacity by adjusting the power supply frequency of their

compressors. In contrast, non-inverter air conditioners have a fixed heating/cooling capacity and can

only control the indoor temperature by starting or stopping their compressors.

ComfortableInverter air conditioners finely adjust

capacity according to changes in the

air-conditioning load and the difference

between the indoor temperature and

set temperature is small. These give

higher comfort levels than with non-

inverter air conditioners.

PowerfulInverter air conditioners operate at

maximum capacity as soon as they

start up. As a result, the set

temperature can be reached more

quickly.

Efficiency of Reluctance DC motor *4

Too cool

Not cool

During cooling operation

Compressor off

Non-inverter type

Inverter type

Cools a roomin less time

Small temp.difference

Compressor off

Temp.

Starts

Time

Settemp.

7

2 00 3 00 4 00 5 00 6 00 7 00 8 00 9 00 1 0 00

0

20

40

80

60

100

   E   f   f   i  c   i  e  n  c  y   (   %   )

Motor speed (rpm)

AC motorApprox.

40%

increase

Approx.

20%increase

DC motor

*5. Data are based on studies conductedunder controlled conditions at a Daikinlaboratory.

*4. Data are based on studies conductedunder controlled conditions at a Daikinlaboratory.

Efficiency of DC motor for fan  *5

(comparison with a conventional AC motor)

Page 5: FTKD25-71

8/21/2019 FTKD25-71

http://slidepdf.com/reader/full/ftkd25-71 5/10

8 9

Rustling of leaves

Pendulum of a wall clock Normal office

Indoor unit

Library

Outdoor unit

Side view

7 m

Top view

  7  m

110˚

This series gives you the choice of 5-step, Quiet or

Automatic settings for the fan speed. The Quiet setting

selects Indoor Unit Quiet Operation. This function

decreases the operation sound level by 3 dB below the

Low setting.

This wide range of settings allows you to precisely

control the fan speed according to your requirements.

For example, Indoor Unit Quiet Operation provides you

with a good night’s sleep. The sound level for FTKE25G

is 25 dB.

Outdoor Unit Quiet Operation is available for all models

from 2.5 to 7.1 kW class. This function decreases the

operation sound level by 3 to 5 dB below the rated

operation. It provides a low sound level of 44 dB for

RKE42G.Capacity may decrease when Outdoor Unit Quiet Operation is selected.

Fan speeds

High (H)

Low (L)

  Quiet (SL)

Sound levels

37 dB

28 dB

25 dB

FTKE25G

(dB) 25   30 40    44    50 20 

25 dB Is So Quiet You Can Even Hear Whispers

Indoor Unit Quiet Operation

Intelligent Eye prevents energy wastage by using its

infrared sensor to detect human movement in a room.

When there is no movement, Intelligent Eye increases the

temperature by 2 C to give energy savings of up to 20%.

This reduces energy wastage if, for example, you forget

to turn off the air conditioner.

All models from 2.5 to 7.1 kW class are equipped

with Intelligent Eye. This function can be conveniently

activated from the remote controller.Once Intelligent Eye is set, it continues to work to save energy. You do not

need to push the SENSOR button each time you wish to use this function.

Intelligent Eye

Outdoor Unit Quiet Operation

3 dB

RKE42G

Operations

Rated (H)

Quiet (L)

Sound levels

49 dB

44 dB

5 dB

Selects fan speed andIndoor Unit Quiet Operation

Indoor Unit Quiet Operation icon

Outdoor Unit Quiet Operation

The Intelligent Eyeindicator lights whenmovement is detected.

Intelligent Eyesensor

Intelligent Eye button

Econo Mode button

When you are in the room, the airconditioner maintains the settemperature.

If Intelligent Eye detects no humanmovement for 20 minutes, itautomatically adjusts the settemperature by 2 C.

When you enter the room,Intelligent Eye automaticallyreturns the temperature to theset level.

Each decrease in airflow volume

reduces the sound level by 2 or 3 dB.

Fan

speed

Sound

level

H

Low High

LSLAuto M

This function limits both the maximum running current

and maximum power consumption to 70% of those

during normal operation. It is particularly effective if the

cooling load is high, for example, at start-up or during

large gatherings and periods of direct sunshine. At the

same time, it maintains maximum capacity at 80% of

normal, giving improved operating efficiency, although it

may take slightly longer to reach the set temperature.

Econo Mode is also useful for preventing circuit

breakers from being overloaded during temporary

peaks in the running current. The function is easily

activated from the remote controller by pushing the

ECONO button. Econo Mode is available for

FTKE25/35G.

Econo Mode

From start-up until settemperature is reached

100%

70%

• This diagram is a representation for illustrative purposes only.

• Maximum capacity decreases during Econo Mode, requiring

more time to reach the set temperature.

Maximum duringnormal operation

Running current andpower consumption

Time

Normaloperation

EconoMode

Maximum duringEcono Mode

Based on “Examples of Sound Levels”, Ministry of the Environment, Japan,

November 12, 2002

Page 6: FTKD25-71

8/21/2019 FTKD25-71

http://slidepdf.com/reader/full/ftkd25-71 6/10

10 11

Titanium apatite is a new photocatalytic

material with advanced adsorption power. While

the filter’s micron-level fibres trap dust, this photocatalyst

effectively adsorbs and decomposes bacteria and viruses,

and also breaks down mould and odours. The photocatalyst

is activated simply by exposure to natural light.

Titanium Apatite PhotocatalyticAir-Purifying Filter

Titanium ApatitePhotocatalyticAir-Purifying Filter

When cooling or dry operation is stopped, fan-only

operation runs automatically for 1 hour. This airflow

dries the inside of the indoor unit to reduce the

generation of mould and odours. It is available with

FTKE25/35G.

Mould-Proof Operation

Flat panel models can be cleaned instantly

with a single wipe of a cloth across their

smooth surface. If more thorough cleaning is

required, the panel can also be easily

removed from the unit.

Wipe-Clean Flat Panel

Front grille design unitscollect dust on their airinlet grilles unless thesegrilles are cleanedregularly.

1. Difficult to remove dust on thegrille through wiping alone

2. Reduced capacity due toincreased suction resistance

3. High sound levels due toincreased suction resistance

Conventional Front Grille Design

Dust

Apatite strongly adsorbs bacteriaand viruses. At the same time, thephotocatalyst powerfully oxidisesodour components, breaking them

down. Viruses are turned intoclumps of protein and removed.

Air filterCatches dust

Bacteria removal testTesting method: Dropping methodTesting organisation: Japan Spinners Inspecting FoundationResult certificate: No. 012553-1 and 012553-2

Effect of Titanium Apatite Photocatalyst

 Titanium Apatite Photocatalyst

Odours

Bacteria Viruses  Decomposed

DeactivatedDeactivated

Natural light

Adsorbs Removes

Photocatalyst Mechanism

The Titanium Apatite Photocatalytic Air-Purifying Filterincorporates titanium apatite. Titanium apatite is a new

photocatalyst material with advanced adsorption power.

When this photocatalyst is exposed to light, a powerfuloxidising action occurs.

Light strikes thephotocatalyst andactivates the surfaceparticles.

A chemical reactiondecomposes the odoursinto CO2, O3 and H 2.

The odourless substancesare released into the air.

Light   Odours

Odours

Photocatalyst

Activeparticles

Page 7: FTKD25-71

8/21/2019 FTKD25-71

http://slidepdf.com/reader/full/ftkd25-71 7/10

12 13

From a corner

to the centre

Covers even

a spacious roomUnit: minutes

Time

Cooling

60

Set temp. beforeOff timer begins

to operate

+0.5 C

O f f t ime r tu rn s o n O f f t im e r s top s a ir co nd it i on er

Heat exchanger fin

Hydrophilic film

Aluminium

Corrosion-resistant

acrylic resin

Comfortable Airflow Lifestyle Convenience Worry Free

Home Leave Operation prevents large rises in

the indoor temperature by continuing operation*while you are sleeping or out of your home.

This means that an air-conditioned welcome awaits

when you wake or return. It also means that the indoor

temperature can quickly return to your favouritecomfort setting.* Home Leave Operation can be set at any temperature from 18 to 32 C.

Home Leave Operation is available for FTKE42G and FTKD50/60/71F.

Inverter Powerful Operation boosts cooling

performance for a 20-minute period. This isconvenient both when you first turn on your air

conditioner and whenyou want to quickly

change the temperature

during operation.

A uniform temperature is

achieved throughout theentire room.

Vertical Auto-Swing automatically

moves the flaps up and downand Horizontal Auto-Swing

automatically moves the louvres to the left and right.3-D Airflow combines Vertical and Horizontal Auto-Swing

to circulate air to every part of a room for uniform

cooling of even large spaces.Horizontal Auto-Swing and 3-D Airflow are available for FTKE42G and

FTKD50/60/71F.

Power-Airflow Dual Flaps and Wide-

Angle Louvres work in tandem toprecisely control both vertical and

horizontal airflow for distribution of air.

Wide-Angle Louvres

Power-Airflow Dual Flaps

Indoor Unit On/Off Switch

The unit can be convenientlystarted manually in the

event the wireless remote

controller is misplaced or thewireless remote controller batteries

are not charged.

Cooling operation: Room temperature is raised by 0.5 C after 60minutes, while minimum outdoor unit sound levels are maintained. If theoutdoor temperature is below 27 C, room temperature is r aised by afurther 0.5 C after 90 minutes for FTKE42G and FTKD50/60/71F.

The louvres can be

adjusted by hand for

FTKE25/35G and with the

wireless remote controller

for FTKE42G and

FTKD50/60/71F.

Pressing the Off timer button automatically selects

Night Set Mode. This function prevents any

sudden change in room temperature by graduallyraising the temprature before the air conditioner stops,

so you can sleep comfortably.

One push!!

Push again!!

Start Home Leave

Operation simply by

pushing its button on the

remote controller.

When you are out of

your home, your air

conditioner prevents

large rises in the indoor

temperature by

continuing to operate

using Home Leave

Operation settings.

When you return, you will

be greeted by an air-

conditioned room. Just

push the HOME LEAVE

button again to return to

your previous settings.

The outdoor unit’s heat exchanger fins are

processed using a special anticorrosiontreatment. The surface is covered with a thin

acrylic resin layer to enhance the fins’ resistance to

acid rain and salt corrosion. A hydrophilic film layer alsoprevents rust caused by the run off of water droplets.

A long piping length gives installation flexibility.Installation is possible even if there is no space for the

outdoor unit near the indoor unit.

Installation Flexibility

Max. piping length

15 m 15 mFTKE25/35G

20 m 20 mFTKE42G

30 m 20 mFTKD50/60/71F

Max. height difference

During cooling operation, 23 C forthe room temperature setting, and28 C for the Home Leave setting.

23 C

28 C

23 C

Cooling: the flaps flatten out during operation so that cool air slides off to

reach the corner of the room.

Cross section of anticorrosion-treated fin

Page 8: FTKD25-71

8/21/2019 FTKD25-71

http://slidepdf.com/reader/full/ftkd25-71 8/1014 15

See page 12

See page 12

See page 12

See page 12

See page 12

See page 12

See page 8

See page 13

See page 12

See page 11

See page 11

See page 12

See page 8

See page 9

See page 9

See page 13

See page 10

Function Dictionary

Comfortable Airflow Comfort Control

Lifestyle Convenience

Cleanliness

Timers

Worry Free

Power-Airflow Dual Flaps can flatten out during coolingoperation to deliver cool air to the corners of a room.

The smoothly curved Wide-Angle Louvres provide wide

airflow coverage for effective operation no matter wherethe indoor unit is placed in a room.

This function automatically moves the flaps up and downto distribute air across a room.

Horizontal Auto-Swing automatically moves the louvresto the left and right to cover a room with cool air.

This function combines Vertical and Horizontal Auto-Swing to circulate a cloud of cool air right to the cornersof even large spaces.

The microprocessor automatically controls fan speed toadjust the room temperature to the set temperature.

This function automatically reduces the level of humiditywhile maintaining the preset room temperature.

Indoor unit operating sound levels are decreased by 2 or3 dB from the Low setting fan speed using the wirelessremote controller.

Outdoor unit operating sound levels are decreased by 3 to5 dB from the rated operation sound using the wirelessremote controller.

Intelligent Eye with its infrared sensor automaticallycontrols air conditioner operation according to humanmovement in a room. When there is no movement, itadjusts the temperature by 2 C for energy savings of up

to 20%.

This function is convenient for boosting cooling performancefor a 20-minute period both when you first turn on yourair conditioner or want to quickly change the roomtemperature.

This mode limits maximum running current and power

consumption to 70% of normal operation, while maintainingmaximum capacity at 80%. This improves operatingefficiency and also prevents circuit breakers from beingoverloaded.

Home Leave Operation continues operation to prevent aroom from becoming too hot, while you are sleeping orout of your home. Select any temperature from 18 to 32 C.

There is a second On/Off switch on the body of the indoorunit to prevent any problems if the wireless remotecontroller is misplaced.

The air filter is finished with a coating that suppresses thegrowth of mould on its surface.

The flat panel models can be cleaned with only the singlepass of a cloth across their smooth surface. The flatpanel can also be easily removed for more thoroughcleaning.

Mould-Proof Operation automatically runs fan-onlyoperation for 1 hour when cooling or dry operation isstopped. This airflow prevents the generation of mouldand mould odours inside the indoor unit.

This timer can be preset to start and stop at any timewithin a 24-hour period. The air conditioner is started/stopped simply by pressing the On/Off timer button on

the wireless remote controller.

Pressing the Off timer button automatically selects NightSet Mode. This function prevents any sudden change inroom temperature by gently raising the temperaturebefore the air conditioner stops, so you can sleepcomfortably.

The air conditioner memorises the settings for mode,

airflow, temperature, etc., and automatically returns tothem when power is restored after a power failure.

Malfunction codes are shown on the digital display panelof the wireless remote controller for fast and easymaintenance.

The outdoor unit’s heat exchanger fins are processedusing a special anticorrosion treatment. The surface iscovered with a thin acrylic resin layer to enhance the fins’resistance to acid rain and salt corrosion.

This filter contains the new photocatalytic materialtitanium apatite. While the filter’s micron-level fibres trapdust, this photocatalyst adsorbs and decomposesbacteria and viruses, and breaks down mould andodours. The filter can be used for up to 3 years withproper maintenance.

Functions

Models

FTKE

25/35G

FTKE42G and

FTKD50/60/71F

Function List

Wall-mounted type

Power-Airflow Dual Flaps

Wide-Angle Louvres

Vertical Auto-Swing (up and down)

Horizontal Auto-Swing (left and right)

3-D Airflow

Auto Fan Speed

Programme Dry Function

Indoor Unit Quiet Operation

Outdoor Unit Quiet Operation

Intelligent Eye

Inverter Powerful Operation

Econo Mode

Home Leave Operation

Indoor Unit On/Off Switch

Mould-Proof Air Filter

24-Hour On/Off Timer

Night Set Mode

Auto-Restart after Power Failure

Self-Diagnosis with Digital Display

Anticorrosion Treatment of OutdoorHeat Exchanger Fins

Wipe-Clean Flat Panel

Mould-Proof Operation

Titanium Apatite PhotocatalyticAir-Purifying Filter

Titanium ApatitePhotocatalyticAir-Purifying Filter

Power-AirflowDual Flaps

   C  o  m   f  o  r   t  a   b   l  e   A   i  r   f   l  o  w

Wide-Angle Louvres

   C  o  m   f  o  r   t   C  o  n   t  r  o   l

Intelligent Eye

Programme DryFunction

Vertical Auto-Swing(up and down)

Indoor Unit QuietOperation

Inverter PowerfulOperation

   L   i   f  e  s   t  y   l  e   C  o  n  v  e  n   i  e  n  c  e

Indoor Unit On/OffSwitch

   C   l  e  a  n   l   i  n  e  s  s

24-Hour On/Off Timer

   T   i  m  e  r  s

Night Set Mode

Auto-Restart after

Power Failure

Anticorrosion Treat-ment of Outdoor HeatExchanger Fins

   W  o  r  r  y   F  r  e  e

Wipe-Clean Flat Panel

Econo Mode

Mould-ProofOperation

3-D Airflow

Home LeaveOperation

Self-Diagnosis withDigital Display

Mould-Proof Air Filter

Auto Fan Speed

Horizontal Auto-Swing

(left and right)

Outdoor UnitQuiet Operation

DC Inverter

Page 9: FTKD25-71

8/21/2019 FTKD25-71

http://slidepdf.com/reader/full/ftkd25-71 9/1016 17

Wireless remote controller for FTKE42G and FTKD50/60/71F

Wireless remote controller for FTKE25/35G

Easy-to-Use Wireless Remote Controller

Vertical Auto-Swing (up and down)

Selects fan speed andIndoor Unit Quiet Operation

Outdoor Unit Quiet Operation

 Intelligent Eye

Cancels On/Off Timer

 24-Hour On Timer

 24-Hour Off Timer and Night Set Mode

Sets timer

 Displays time

Vertical Auto-Swing (up and down)

Selects fan speed andIndoor Unit Quiet Operation

Selects mode: cooling,dry, fan-only operation

Outdoor Unit Quiet Operation

Cancels On/Off Timer

 24-Hour On Timer

 24-Hour Off Timer and Night Set Mode

Sets timer

 Displays time

On/Off Switch

Econo Mode

Inverter Powerful Operation

Sets room temperature

On/Off Switch

Home Leave Operation

Inverter Powerful Operation

Sets room temperature

Specifications

Selects mode: cooling,dry, fan-only operation

Measurement conditions1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.2. Sound levels are based on the temperature condition 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual

operation as a result of ambient conditions.

Horizontal Auto-Swing

(left and right)

Intelligent Eye

Mould-Proof Operation

Indoor unitOutdoor unit

Model name

Capacity

Power supply

Running currentPower consumptionCOPIndoor unitFront panel colourAirflow rate (H)Fan speedSound levels (H/L/SL)

Dimensions (H x W x D)Machine weightOutdoor unit

Casing colour

Compressor

Refrigerant charge (R-22)Sound levels (H/L)Dimensions (H x W x D)Machine weightOperation range

Piping connections

Max. piping lengthMax. height difference

Rated (Min.-Max.)

RatedRated (Min.-Max.)

Rated

Motor output

FTKE25GV1RKE25GV12.5 (1.6-3.2)

8,500 (5,450-10,900)

4.3-4.2-4.1746 (455-1,180)

FTKE25GV1

8.9 (314)

37/28/25

RKE25GV1

0.6747/43

30

9.5

FTKE35GV1RKE35GV13.2 (1.6-4.0)

10,900 (5,450-13,600)

4.6-4.5-4.4955 (455-1,550)

 FTKE35GV1

9.0 (318)

39/29/26

RKE35GV1

0.7748/44

32

  12.7

Indoor unitOutdoor unit

Model name

Capacity

Power supplyRunning currentPower consumptionCOPIndoor unit

Front panel colourAirflow rate (H)Fan speedSound levels (H/L/SL)Dimensions (H x W x D)Machine weightOutdoor unitCasing colour

Compressor

Refrigerant charge (R-22)

Sound levels (H/L)Dimensions (H x W x D)Machine weightOperation range

Piping connections

Max. piping lengthMax. height difference

Rated (Min.-Max.)

  RatedRated (Min.-Max.)

Rated

Motor output

FTKD50FVMRKD50BVM5.2 (1.5-5.9)

17,700 (5,100-20,100)

7.3-7.0-6.71,600 (450-2,300)

3.25FTKD50FVM

16.8 (593)

44/35/32

RKD50BVM

1.25

47/44--

48

FTKD60FVMRKD60BVM6.2 (1.5-6.5)

21,200 (5,100-22,200)

9.6-9.2-8.82,100 (450-2,700)

2.95FTKD60FVM

17.5 (618)

45/36/33

RKD60BVM

1.60

49/46735 x 825 x 300

52  5 to 46

30

FTKE42GV1RKE42GV14.2 (2.0-5.0)

14,300 (6,800-17,100)

1 phase, 220-240 V, 50 Hz5.8-5.6-5.4

1,253 (560-1,650)3.35

FTKE42GV1

15.3 (540)

42/36/33

RKE42GV1

6001.32

49/44550 x 765 x 285

3719.4 to 46

20

FTKD71FVMRKD71BVM7.1 (2.1-7.6)

24,200 (7,200-25,900)

11.7-11.2-10.72,550 (530-3,210)

2.78FTKD71FVM

18.3 (646)

46/37/34

RKD71BVM

1,9001.80

52/49

54

9.5

 1,500

FTKE25/35G

FTKE42G and FTKD50/60/71F

1 phase, 220-240 V/220-230 V, 50/60 Hz(220-230-240V, 50Hz )

LiquidGas

 Drain

 

1 phase, 220-240 V, 50 Hz

3.35

White

5 steps, quiet and automatic

283 x 800 x 1959

Ivory whiteHermetically sealed swing type

600

550 x 765 x 285

19.4 to 466.4

  18.01515

kWBtu/h

AW

W/W

m3/min (cfm)

dB (A)

mmkg

Wkg

dB (A)mmkg

 CDB

mm

m

LiquidGas

 Drain

 

White

5 steps, quiet and automatic

290 x 1,050 x 23812

Ivory whiteHermetically sealed swing type

  18.0

20

kWBtu/h

AW

W/W

m3/min (cfm)

dB (A)mmkg

Wkg

dB (A)mmkg

 CDB

mm

m

6.4

12.7

Specifications are subject to change.

Type

  15.9

Type

For AC 1,2,3,8,10 For AC 4,7

For AC 5 For AC 6

Page 10: FTKD25-71

8/21/2019 FTKD25-71

http://slidepdf.com/reader/full/ftkd25-71 10/1018 19

5-room centralisedcontrollerKRC72

Remote controller lossprevention with chainKKF917A4

Options

Outdoor unit

Control system

No.

1

2

Item

Air direction adjustment grille

Drain plug

Note: *1. One set includes 5 pieces for 5 units.

Central remote controllerDCS302CA61

Unified On/Off controllerDCS301BA61

Schedule timerDST301BA61

Air direction adjustment grilleKPW945A4

Drain plugKKP937A4

No.

1

2

3

4

Item

Central remote controller

Unified On/Off controller

Schedule timer

Interface adaptor for DIII-NET use

Note: *1. A wiring adaptor (KRP928B2S) is also required for each indoor unit.

*1

*1

*1

Titanium apatite photocatalyticair-purifying filterKAF952B42

DCS302CA61

DCS301BA61

DST301BA61

KRP928B2S

FTKE25/35G

KKP937A4*1

RKD50/60/71B

KPW945A4

RKE25/35/42G

KPW937A4

Titanium apatite photocatalyticair-purifying filterKAF970A46

Indoor unit

Note: *1. A wiring adaptor (KRP413A1S) is also required for each indoor unit.  *2. The time clock and other devices should be obtained locally.

*3. The filter is a standard accessory. It should be replaced approximately every 3 years.

No.

1

2

3

4

Item

5-room centralised controller

Wiring adaptor for time clock/remote controller(Normal open pulse contact/normal open contact)

Titanium apatite photocatalytic air-purifying filter

Remote controller loss prevention with chain

FTKE42G and FTKD50/60/71F

KAF952B42

FTKE25/35G

*1

*2

*3

Specifications are subject to change.

KKF917A4

KAF970A46

KRC72

KRP413A1S

FTKE42G and FTKD50/60/71F