FS/FD Cast Device Boxes and Covers Application Cast device boxes are installed to: • Accommodate wiring devices • Act as pull boxes for conductorsin a threaded rigid conduit system, including an internal ground screw • Provide openings to make splices and taps in conductors • Provide access to conductors for maintenance and future system changes • Connect conduit sections Features All hubs have NPT Threads with a minimum of five full threads and integral bushing. Internal grounding screw standard on boxes. • Suitable for wet locations when used with gasketed covers • Available in shallow (FS) or deep (FD) boxes. Use FD if device to be enclosed exceeds 1 5 ⁄8" in depth • Use blank bodies where special arrangements of conduit hubs or entrances are required • All cover holes are #6-32 • Mounting lugs are standard on all FS and FD boxes Size Range • Hubs: 1 ⁄2" to 1" NPT Materials • Boxes: Class 30 Gray iron alloy • Covers: Sand cast AL alloy and sheet steel • Gaskets: Neoprene Finish • Zinc-plated with aluminum acrylic paint Listing Certifications • UL: 514A (wet locations when used with gasketed covers) • CSA: C22.2 No.18 C E B F G A D C E B A A Dead-End B Dead-End Single-Gang Cast Device Boxes A-52 United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 www.tnb.com
12
Embed
FS/FD Cast Device Boxes and Covers Single-Gang Cast Device ... · FS/FD Cast Device Boxes and Covers Application Cast device boxes are installed to: • Accommodate wiring devices
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
FS/FD Cast Device Boxes and Covers
ApplicationCast device boxes are installed to:
• Accommodate wiring devices
• Act as pull boxes for conductorsin a threaded rigid conduit system, including an internal ground screw
• Provide openings to make splices and taps in conductors
• Provide access to conductors for maintenance and future system changes
• Connect conduit sections
FeaturesAll hubs have NPT Threads with a minimum of five full threads and integral bushing. Internal grounding screw standard on boxes.
• Suitable for wet locations when used with gasketed covers
• Available in shallow (FS) or deep (FD) boxes. Use FD if device to be enclosed exceeds 15⁄8" in depth
• Use blank bodies where special arrangements of conduit hubs or entrances are required
• All cover holes are #6-32
• Mounting lugs are standard on all FS and FD boxes
Size Range• Hubs: 1⁄2" to 1" NPT
Materials• Boxes: Class 30 Gray iron alloy
• Covers: Sand cast AL alloy and sheet steel
• Gaskets: Neoprene
Finish• Zinc-plated with aluminum acrylic paint
Listing Certifications• UL: 514A (wet locations when used with gasketed covers)
• CSA: C22.2 No.18
C
E B
F
GA
D C
E B
A
A
Dead-End
B
Dead-End
Single-Gang Cast Device Boxes
A-52
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
CanadaTel: 450.347.5318Fax: 450.347.1976
Technical ServicesTel: 888.862.3289
www.tnb.com
FS/FD Cast Device Boxes and Covers
Shallow Single-Gang Cast Device BoxesCAT. HUB DIMENSIONS (IN.) THROAT DIA.NO. FIG. SIZE A B C D E F G MIN. MAX.
Dead-EndFS019-TB A Blank 2 23⁄4 49⁄32 — 33⁄8 423⁄32
and hinge pins provide increased corrosion resistance
• Die cast construction, boxes with securely fastenedmounting plates and industrial designed covers combine to produce a rugged protective enclosure for devices on industrial and OEM applications
• Clean cover edges provide good gasket sealing
• Precision NPT threaded hubs allow trouble-free field installation for rigid or IMC conduit
• Clear UL, CSA and cubic content markings speed approval by inspectors
Standard Materials• Die cast aluminum alloy A360 with less than
.004 copper content (copper-free)
• Cover hinge pins and springs: Stainless steel
Standard Finish• Aluminum lacquer finish
Compliances:• UL Listed
• Boxes CSA Certified with factory installed ground screw **
• Covers CSA Certified
• Federal Spec. W-C-586
Sample Specifications• Industrial grade FS device boxes and covers shall be die
cast copper-free* aluminum alloy A360. All conduit stopsshall be coined and free of rough edges. Raintight coversshall have stainless steel springs and hinge pins and aresuitable for use in wet locations with cover closed (CFSB,CFST and CFSTF suitable for wet locations). Industrial gradeFS device boxes and covers shall be finished withaluminum lacquer. Industrial grade FS device boxes andcovers shall be Thomas & Betts Catalog No. _______
*Less than .004 copper content
**Consult factory for lead time and minimum quantity.
A-56
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
CanadaTel: 450.347.5318Fax: 450.347.1976
Technical ServicesTel: 888.862.3289
www.tnb.com
FS/FD Aluminum Device Boxes and Covers
AFS
AFSC
AFSS
AFSCC
ADFS
ADFSC
2AFS 2AFSC
2ADFS
Single Gang Boxes Raintight*HUB UNIT STD. WT. LBS.
*Raintight when used with appropriate Thomas & Betts boxes.
CFST
CWPV-DR CFSDR
CFSR-G
A-58
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
CanadaTel: 450.347.5318Fax: 450.347.1976
Technical ServicesTel: 888.862.3289
www.tnb.com
FS/FD Aluminum Device Boxes and CoversSuitable for use in Wet Locations with Cover ClosedNEMA 3R
2CWPDR
2CFST
Two Gang Covers Complete with Gasket and Screws — Raintight*
UNIT STD. WT. LBS.CAT. NO. DESCRIPTION QTY. PKG. PER 100
For Two Duplex Receptacles2CWPDR* Two Duplex Receptacle Cover with 2 Spring Doors, 1 10 48
Device Mount
For Switch and Duplex Receptacle2CWTDR* Switch and Duplex Receptacle Cover, Box/Device Mount 1 10 48
For Single Receptacle2CWPR-M* Single Receptacle Cover, Hole Dia. 21⁄4”, Device Mount 1 10 482CFSR-M* Single Receptacle Cover, Hole Dia. 21⁄4”, Box Mount 1 10 48
For Two Switches2CFST* Plunger Style Switch Cover, Box Mount 1 10 26
Blank2CFSB* Blank Cover, Box Mount 10 50 25
*Raintight when used with appropriate Thomas & Betts boxes.
CDR CTS
CR Series
Single Gang Covers Complete with Gasket and Screws
UNIT STD. WT. LBS.CAT. NO. DESCRIPTION QTY. PKG. PER 100
For Duplex ReceptaclesCDR Duplex receptacle Cover, Box Mount 20 100 11
For SwitchesCTS Switch Cover, Box Mount 20 100 14
NOMINAL MAX. DEVICE UNIT STD. WT. LBS.CAT. NO. SIZE FACE DIA. QTY. PKG. PER 100
For Single Receptacles (Box Mount Only)CRL 19⁄16" 1.600" 20 100 12CRS 13⁄8" 1.395" 20 100 12CRX-L 21⁄8" 2.145" 20 100 12
STD. WT. LBS.CAT. NO. DESCRIPTION PKG. PER 100
GasketFS-GKV Composition Gasket 100 2
2CDR 2CTS
2CTDR 2FS-GKV
Two Gang Covers Complete with Gasket and Screws UNIT STD. WT. LBS.
CAT. NO. DESCRIPTION QTY. PKG. PER 100
For Two Duplex Receptacles2CDR Two Duplex Receptacle Cover, Device Mount 10 50 24
For Two Switches2CTS Switch Cover, Device Mount 10 50 24
For Switch and Duplex Receptacles2CTDR Switch and Duplex Receptacle Cover, Device Mount 10 50 24
Gasket2FS-GKV Composition Gasket — 50 3
2CWPR-M
2CFSB
2CWTDR
2CFSR-M
FS-GKV
A-59
United StatesTel: 901.252.8000
800.816.7809Fax: 901.252.1354
CanadaTel: 450.347.5318Fax: 450.347.1976
Technical ServicesTel: 888.862.3289
www.tnb.com
FS/FD Aluminum Device Boxes and Covers
CAT. HUB DIMENSIONS (IN.)NO. SIZE A B C D E F G H J CI