B C D E F H I J K L M P 35 m² Electrical Plant Room 36 m² Boiler Room 32 m² Solar Plant Room 45 m² Water Plant Room 24 m² Hall 5 m² Service Riser 114 FD30 115 FD30 125 FD30 138 139 FD30 140 FD30 141 FD60 142 FD30 CarPark Exit CarPark Entrance 28 m² Stair 4 18 m² Building Contol Centre 7 m² Bed Lift 5 m² Lift 37 m² Lobby FD 31 FD30 37.5m (T D ) 26.1m (TD) 69.000° 9.9m (OD) 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 13 A B C D E F H I J K L M P 5300 6 FD30 8 FD30 9 FD30 10 FD30 11 FD30 12 FD30 13 FD30 14 FD30 15 FD30 17 FD30 18 FD30 34 FD30 36 FD30 37 FD30 38 FD30 39 FD30 42 FD30 43 FD30 44 FD30 45 FD30 46 FD30 47 FD30 48 FD30 49 FD30 50 FD30 109 FD30 110 FD30 111 FD30 16 m² Book TR Room 24 m² Speech Therapy 20 m² Stair 3 27 m² Speech Therapy 14 m² Book TR Room 16 m² Medical Store 4 m² WC & Shower 4 m² Staff WC 6 m² Hall 9 m² Womens Toilets 4 m² Womens WC 8 m² Mens Toilets 5 m² Mens WC 18 m² Wound Clinic 11 m² Medical Store 18 m² Wound Clinic 15 m² Bookable Room 28 m² Family Rm/Care Doc 34 m² Reception 30 m² Waiting Area 20 m² Community Welfare 15 m² Bookable Room 18 m² Room 17 m² Child Health 17 m² Sound Proof Room 14 m² Stairs 32 m² HSE Circulation 359 m² Pharmacy 120 m² Medical Services Rm1 116 m² Medical Services/Storage 19 m² HSE Store 11 m² HSE Hall 34 m² HSE Dr Room 51 m² HSE Reception & Treatment Rm 16 m² HSE Office 127 FD60 128 FD60 69 FD60 81 FD30 80 FD30 79 FD30 78 FD30 129 FD30 15 m² Stairs 1 29 m² Stair 4 112 m² Restaurant /Caffe 80 m² Medical Services 67 m² OT GA Room 72 FD60 77 FD30 71 FD30 76 FD30 70 FD30 73 FD60 74 FD60 75 FD60 82 FD60 9 m² WC F 5 m² Hall 9 m² WC M 14 m² Storage 7 m² Hall 4 m² WC 107 106 FD60 108 136 FD60 135 FD60 133 FD60 91 m² Room 4664 2703 5190 14.2m (OD) 27.1m (TD) 9.3m (TD) 15.6m (TD) 18.4m ( TD ) 6.9m (OD) 5.6m (TD) www.autodesk.com/revit Scale LECTURER Drawn by Date Project number Institute of Technology Carlow BSc. in Architectural Technology Year 3 2015-2016 1 : 200 19/04/2016 18:16:59 Fire Certificate Plans Project Number 3 Carlow Primary Health Care Centre 22/04/2016 Xhevdet Haliti Dan O Sullivan, Noel Dunne, Mark Duffy A129 1 : 200 Fire Basement floor plan 1 1 : 200 Fire Ground floor plan 2 LEGEND : Travel Distances: - One Direction: OD - Two Direction: TD 30 min protected corridor in accordance with section 1.2.5.1. and table A1 TGD B 2006 60 min protected stair wall in accordance with table A2 TGD,Part B 2006. i.e. top storey served not more than 5m above Ground level 90 min protected stair well in accordance with table A2 TGD, Part B 2006. Top storey served not more than 20m above Ground Level 90 min compartment wall/floor in accordance with section 3.2, table A2 and appendix C, TGD B 2006 30 min fire resistant door set in accordance with BS476 Part 22, fitted with Intumescent strips and smoke seals. Doorset to be fitted with automatic self-closing device which shall be capable of closing the for from any angle and against any latch fitted Disabled refuge area (1400x900mm). Two way communication to the internal refuge area only Emergency escape lighting to comply with table 1.8 TGD B- to be designed , installed and certified in accordance with IS 3217:20013. Fire detection system type L1 to be designed, certified in accordance with IS 3218:2009(2013) The use, inspection and maintenance of fire extinguishers to be designed , installed and certified in accordance with IS 291:2002 Steel columns, beams and portal frames used to support load bearing, fire resisting elements of structure to be protected and to give 90min fire rating 60 min fire resistant door set in accordance with BS476 Part 22, fitted with Intumescent strips and smoke seals. Doorset to be fitted with automatic self-closing device which shall be capable of closing the for from any angle and against any latch fitted NOTES: (1) Refers to area of room or storey, as appropriate, with area calculated in accordance with Section 1.0.10(a) of TGD-B 2006. (2) Occupancy load factors as per Table 1.1 of TGD-B 2006. (3) Such areas will generally be unoccupied or alternatively will be occupied by the same persons within the remainder of the premises and therefore double counting of both areas are avoided. (4) Number of persons to such rooms taken as two (i.e. a patient and a consultant)