1 © Nokia Siemens Networks Presentation / Author / Date For internal use FlexiPacket Series - FlexiPacket Hub 800(FPH800) Packet Mode Introduction MWT Shanghai * FPH800 in this slides indicates FPH800 Packet M
1 © Nokia Siemens Networks Presentation / Author / DateFor internal use
FlexiPacket Series -
FlexiPacket Hub 800(FPH800) Packet Mode Introduction
MWT Shanghai
* FPH800 in this slides indicates FPH800 Packet Mode* FPH800 in this slides indicates FPH800 Packet Mode
2 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Tail / Chain Aggregation/Core Service CoreApplications
Any BTS2G, 3G, iHSPA,LTE, WiMAX
Hub
FlexiPacket Series Products in Tail/Chain/Hub Site
FlexiPacket Radio
FlexiPacket FirstMile 200 FlexiPacket Hub 800 Cisco/Tellabs
hiT7xxx
3 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Microwave
Copper
Fiber
TDM E1/T1
MLPPP E1/T1
IMA E1/T1
FE
GE
RNC
BSC
S-GW
STM-1/4
GE
• 1U Height• 4xcopper GE (2 P+E)• 2xSFP option for GE or STM-1• 16xE1/T1 with 75/100/120ohm• 1xOOB (out of band)/1xDCN
• 1xAlarm• 1xUSB• 1x1PPS&ToD• 2xDC Input (-48V)• Pluggable FAN tray
• 4xGE optical
• 4xGE copper
• 16xE1/T1/J1
• Power Injector (2 P+E)
• 2xSTM-1/STM-4
• 2xFlexBus
• 2xFPMR
Cost-effective Modularity Solution for Complicated Access Domain
Zero FootprintIDU
2G/3G/LTE
FirstMile 200
FPH800
Microwave
Copper
FiberPacket
Diversity of Services/Interfaces supported by Modularity Architecture
Two Option Card Slots FlexiPacket Hub 800 Main Board
SDH
4 © Nokia Siemens Networks Presentation / Author / DateFor internal use
4xGE(e)4x10/100/1000BASE
2xFBCompliant to ex-siemens BTS
Any Option Cards on Any Slots, No Limitation!
Diversity of Option Cards adapt for Complicated Access Domain
2xFB
2x Power Injector 16xE1Multi-service: TDM PW, ML-PPP
2xSTM-1/4Flexible configure to STM-1 or STM-4
2xFPMR 4xGE(o)4x100/1000BASE-X
IF Max. Quantity
per FPH800
E1 48
GE SFP 10
GE RJ45
12
STM-1 6
STM-4 4
FB 4
P+E 4
FPMR 8
5 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Multi-service Supported by FPH800 & Relative Panels
• CESoP/SAToP based on RFC5086/4553
• Flexible configuration based on slot level
• Flexible packet encapsulation
from 1 to 32 E1/T1 frame length
• Flexible configuration for PWE
packet header
• Both Differential clock recovery (DCR) and Adaptive clock recovery (ACR) supported
• CESoP/SAToP based on RFC5086/4553
• Flexible configuration based on slot level
• Flexible packet encapsulation
from 1 to 32 E1/T1 frame length
• Flexible configuration for PWE
packet header
• Both Differential clock recovery (DCR) and Adaptive clock recovery (ACR) supported
• Max 16xE1 per ML-PPP Group
• Max 16 ML-PPP Group
• 64Kbps based
• Support ML-PPP protection
•Support static IP routing
• Max 16xE1 per ML-PPP Group
• Max 16 ML-PPP Group
• 64Kbps based
• Support ML-PPP protection
•Support static IP routing
• RFC5086/4553
•Encapsulated in IP inlcuding payload and header of STM-1
•Total 4 STM-1 supported per device
• RFC5086/4553
•Encapsulated in IP inlcuding payload and header of STM-1
•Total 4 STM-1 supported per device
FPH800 with 16xRJ48C Panel
1.0/2.3(CC4) Panel: 1/2U Height
16xRJ48C Panel: 1/2U Height
BNC Panel: 1U Height
TDM E1/T1 PWE(CESOP/SAToP)
Multilink PPP(ML-PPP)
STM-1 PWE
6 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Right Product on MWT Hub Site by Supporting more FlexiPacket Radio
• Max 4 P+E ports supported by one FPH800• Up to 2 P+E ports supported by main board
• Up to 1 power injector card supported
• Max 12 Eth ports can be connected to FlexiPacket Radio
• P+E ports can be connected to FlexiPacket Radio directly
• Other ports can be connected with FlexiPacket Radio through external power injector.
• MWR Link protection via CCM• 1+1 Hot Standby (HSBY)
• MWR ring protection supported
• Max 4 P+E ports supported by one FPH800• Up to 2 P+E ports supported by main board
• Up to 1 power injector card supported
• Max 12 Eth ports can be connected to FlexiPacket Radio
• P+E ports can be connected to FlexiPacket Radio directly
• Other ports can be connected with FlexiPacket Radio through external power injector.
• MWR Link protection via CCM• 1+1 Hot Standby (HSBY)
• MWR ring protection supported
2 P+E supported by Mainboard
1 Power Injector cardsupported
Ethernet 1Ethernet 2
P+E 1P+E 2
P+E 3P+E 4
Eth
ern
et
1E
the
rne
t 2
P+E 1P+E 2
External Power Injector
FM200
FM200
FM200
FPH800
MWRRing
1+1 HSBY
Features about FlexiPacket Radio
FPH800 with External Power Injector
FlexiPacket Radio Interfaces on FPH800
FPH800 with Four FlexiPacket Radio
Packet
FPR FPR
FPR FPR
LAGGE
7 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Capable for existing SDH aggregation networks
• Support 2xSTM-1 interfaces on Main Board
• Combo port with GE SFP
• Support 2xSTM-1/4 interfaces on option card• Support MSP 1+1• Support EoS (Ethernet over SDH)• Following is supported protocol for EoS:
• GFP (Generic Framing Protocol)
• VCAT (Virtual Concatenation): Up to 8 VC12/VC4 VCG
• LCAS (Link Capacity Adjustment Scheme)
• Up to 63xE1 can be mapped on each STM-1/4 interface on 2xSTM-1/4 card.
• Support 2xSTM-1 interfaces on Main Board
• Combo port with GE SFP
• Support 2xSTM-1/4 interfaces on option card• Support MSP 1+1• Support EoS (Ethernet over SDH)• Following is supported protocol for EoS:
• GFP (Generic Framing Protocol)
• VCAT (Virtual Concatenation): Up to 8 VC12/VC4 VCG
• LCAS (Link Capacity Adjustment Scheme)
• Up to 63xE1 can be mapped on each STM-1/4 interface on 2xSTM-1/4 card.
2xSFP can be Configured to STM-1
2xSTM-1/4 card can besupported
SDH
E1
Features of STM-1/4 Interface Interfaces on Main Board and 2xSTM-1/4 Card
FPH800 connected with existing SDH networks
Eth
EthE1FPR
STM-1/4
MSP 1+1
8 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Leverage Legacy Networks
• Support STM-1 PWE including payload and header
•Support Max 4xSTM-1 interface PWE
• Support STM-1 PWE including payload and header
•Support Max 4xSTM-1 interface PWE
• Multi E1s from remote sites can be groomed to single E1
•Save Opex especially for leased line Operator
•Max 112 remote E1s groomed to local 16 E1 on Main board
• Multi E1s from remote sites can be groomed to single E1
•Save Opex especially for leased line Operator
•Max 112 remote E1s groomed to local 16 E1 on Main board
FPH800 Hybrid-mode
STM-1 PWE
E1 Grooming
FPH800 Between Legacy SDH Network
FPH800 for Leased Line Operator
SDH
STM-1
FPRSTM-1
SDH
SDH
E1
FPR
E1
FM200
FPR
FPR
E1
9 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Compliant to Diversity of Legacy Interfaces
• Compliant to ex-Nokia FB interface
• Max. two 2xFB card is supported
• No power feeding on 2xFB card
• Up to 16xE1 encapsulated per each FB except the bandwidth for Ethernet
• Compliant to ex-Nokia FB interface
• Max. two 2xFB card is supported
• No power feeding on 2xFB card
• Up to 16xE1 encapsulated per each FB except the bandwidth for Ethernet
Up to two 2xFB cardssupported
FB
• Compliant to Hybrid FPMR ODU• Max. two 2xFPMR card is supported
• Standardized GE RJ45 interface with proprietary cable frame encapsulated
• External power injector or Power injector card can provide power to ODU
• Native E1 and Native Ethernet are included on FPMR interface
• Up to 75xE1 encapsulated per FPMR interface
• Compliant to Hybrid FPMR ODU• Max. two 2xFPMR card is supported
• Standardized GE RJ45 interface with proprietary cable frame encapsulated
• External power injector or Power injector card can provide power to ODU
• Native E1 and Native Ethernet are included on FPMR interface
• Up to 75xE1 encapsulated per FPMR interface
2xFPMR card Power Injector Card
FPH800 Hybrid-mode
FPH800 Packet Mode
FPMR 1+1
2xFlexiBus (FB) Card
2xFlexiPacket MultiRadio (FPMR) Card
FPH800 with ex-Nokia Base Station
FPH800 connected with FPH800 Hybrid-mode
10 © Nokia Siemens Networks Presentation / Author / DateFor internal use
CET E-Line/E-LAN Traffic Supported by FPH800
• P2P EVC for E-Line• Each service includes two ports• Max 256 services• Traffic from one port forward to another directly
• P2P EVC for E-Line• Each service includes two ports• Max 256 services• Traffic from one port forward to another directly
P2P EVC
CET NetworkCECE
UNIUNI UNIUNI
CECE
Point to Point(P2P)
Multipoint to Multipoint(MP2MP)
P2P E-Line Network Scenario
• MP2MP EVC for E-LAN• Each service includes multiple ports• Max 256 services•Each service has separate MAC address table, and MAC address learning• Forward packet based on MAC address
• MP2MP EVC for E-LAN• Each service includes multiple ports• Max 256 services•Each service has separate MAC address table, and MAC address learning• Forward packet based on MAC address
MP2MP E-LAN Network Scenario
CET Network
Multi-point to multi-point EVC
CECE
UNIUNI
CECE
UNIUNI
11 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Multiple QOS Mechanisms
• Ingress rate limit per port• Unknown unicast/multicast/broadcast storm control per port• RED dropping mechanism• Queue schedule algorithms as below:
• SP• WRR• WDRR
• Egress shaping• Per port shaping• Per queue shaping
• Ingress rate limit per port• Unknown unicast/multicast/broadcast storm control per port• RED dropping mechanism• Queue schedule algorithms as below:
• SP• WRR• WDRR
• Egress shaping• Per port shaping• Per queue shaping
Multi QoS Mechanisms
FlexiPacket Hub800 QoS Model
Ingress
Receive frame
Ingress rate limit
Storm restraint sRED
Discard
Congestion detection/avoidance
SP
WRR
WDRR
In queue
Egress
shaping
Out queue
Discard
Leaky bucket
Token
Egress
12 © Nokia Siemens Networks Presentation / Author / DateFor internal use
• Support below Bandwidth Profile types• Per UNI port• Per Service• Per CoS• Per mapping rule
• Bandwidth Profile parameters• CIR• CBS• PIR• PBS
• Support below Bandwidth Profile types• Per UNI port• Per Service• Per CoS• Per mapping rule
• Bandwidth Profile parameters• CIR• CBS• PIR• PBS
Bandwidth Guarantee
FlexiPacket Hub800 SLA Flow Process
MarkClassification
Packet
Shaping/drop
Mark
Bandwidth Guarantee
13 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Ethernet OAM Mechanism 2G/3G RNC/BSC
Ethernet service OAM: IEEE 802.1ag / ITU-T1731802.3ah 802.3ah
Ethernet Service OAM • Connectivity check: Hardware based;
Max 256 3.3ms/10ms flows supported
• Loopback / Linktrace
• AIS/RDI
• APS: automatic protection switch
• Loss Measurement
• Delay Measurement
•Throughput Measurement
Ethernet Link OAM
IEEE 802.1ag ITU-T Y.1731
• Discovery
• Remote failure indication
• Remote Loopback
• Threshold crossing alarms
IEEE 802.3ah
Connectivity Fault Management Performance Management
Ethernet Link in FirstMile
ITU-T Y.1731
14 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Equipment Protection: Dual IDU Protection
• Dual IDU protection supported for connected interfaces with the following three solutions:
• Y-Cable: Optical GE can be protected
• Protection Panel: Optical/Copper GE, E1 can be protected
• Dual IDU Power Injector: 1+0 ODU can be protected
• Dual IDU protection supported for connected interfaces with the following three solutions:
• Y-Cable: Optical GE can be protected
• Protection Panel: Optical/Copper GE, E1 can be protected
• Dual IDU Power Injector: 1+0 ODU can be protected
LPGLPGLPGLPG1+0 ODU1+0 ODU
Local InterfaceLocal Interface
Dual IDU protection supported for
connected interfaces with the right three
solutions
Y-Cable
Protection PanelPower Injector
Cable solution for Optical GE
Panel Solution for Optical/CopperGE, E1
Box Solution for 1+0 ODU
Main Features of Dual IDU Protection Dual IDU Outlook
Optical SplitterOptical Splitter
15 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Dual IDU Protection: Protection Panel
IDU#2 8xGE RJ45
IDU#1 8xGE RJ45
User 8xRJ45
IDU#22xLC
IDU#1 2xLC
User 2xLC
IDU#1 16xE1 MDR68
IDU#216xE1 MDR68
User 16xE1 MDR68
Height: 1U
LPGLPG
E1/Optical GE/RJ45 GE
BTS/NodeB
Protection Panel: 8xGE Copper+2xGE Optical+16xE1 Dual IDU with Protection Panel
16 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Dual IDU Protection: Dual IDU Power Injector Panel
Height: 2/3U
User 4xGE(ODU)
Alarm PortFor Dual IDU
LPGLPG
1+0 ODU
Power Injector Panel: 4xGE(P+E) per Unit Dual IDU with Power Injector
17 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Interface Protection on Single & Dual IDU
……
…
…
1+1 Hot-Standby Protection On Single IDU
LAG Protection on Single IDU
1+1 Hot-Standby Protection On Dual IDU
LAG Protection on Dual IDU
MPS 1+1 Protection on Single IDU
MSP 1+1 Protection on Dual IDU
STM-1/4STM-1/4 STM-1STM-1STM-1STM-1
GEGE
GEGE
STM-1/4STM-1/4
GEGEGEGE
* STM-4 MSP1+1 is not available for dual IDU* STM-4 MSP1+1 is not available for dual IDU
18 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Network Protection: Sub 50ms Linear Protection and Ring Protection
• Compliant to G.8031
• 1:1 linear APS protection
• Up to 128 protection services supported
• Sub 50ms traffic protection while CCM interval is 3.3ms
• Supported on both single IDU and Dual IDU
• Compliant to G.8031
• 1:1 linear APS protection
• Up to 128 protection services supported
• Sub 50ms traffic protection while CCM interval is 3.3ms
• Supported on both single IDU and Dual IDU
• Compliant to G.8032
• Sub 50ms traffic protection while CCM interval is 3.3ms
• Supported on both single IDU and Dual IDU
• Compliant to G.8032
• Sub 50ms traffic protection while CCM interval is 3.3ms
• Supported on both single IDU and Dual IDU
…
…
RNC/BSC
Network
2G/3G
Network
RNC/BSC
Sub 50ms traffic protection
Linear Protection
Ring Protection
Linear Protection Network Scenario
Ring Protection Network Scenario
Sub 50ms traffic protection
19 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Spanning Tree Protocol: RSTP/MSTP
• Compliant to 802.1W(RSTP) and 802.1S(MSTP)
• Compliant to STP
• Sub second convergence time within the 8 nodes ring
• Compliant to 802.1W(RSTP) and 802.1S(MSTP)
• Compliant to STP
• Sub second convergence time within the 8 nodes ring
2G/3GRNC/BSC
RSTP/MSTP Features Supported
RSTP/MSTP Protection Network Scenario
20 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Diversity of Synchronization Technologies Supported
Compatible with G.8261/G.8262Support SSM technology
Compatible with legacy equipment
not supporting SSM
Support regenerator of recovery clock by Sync E
• Each E1/T1 ports can be configured as sync clock input or output
These technologies are not exclusive and can be used flexibility according to real network
• Support IEEE1588 v2
• Mode supported– Slave clock mode
– Boundary clock mode
• Support BMC• Provide both the frequency sync and time sync output to base station
10G
RNC
1G
2M
Features of Sync Ethernet Sync Ethernet Network Scenario
E1/T1
1PPS&ToDFlexi WCDMA
BTS
RNC
RNCsite node
Timing packets (unicast) 2MHz/2MbpsGPS
2M
1588master
Packet
Features of IEEE1588 IEEE1588 Network Scenario
21 © Nokia Siemens Networks Presentation / Author / DateFor internal use
All-Outdoor Case Solution with FlexiOutdoor Case
• Adapts to cabinet-less option• Floor, Pole and wall Mount
• Suitable for IDU installed on non- weather protected environment
• FOC contains four fans for hot radiate
and heating elements for pre-heater
• Temperature range can be extended to
(-40°C, +55°C) in FOC from (-5°C, +50°C)
• Support two FPH800 in FOC
• Adapts to cabinet-less option• Floor, Pole and wall Mount
• Suitable for IDU installed on non- weather protected environment
• FOC contains four fans for hot radiate
and heating elements for pre-heater
• Temperature range can be extended to
(-40°C, +55°C) in FOC from (-5°C, +50°C)
• Support two FPH800 in FOC
Features of FlexiOutdoor Case
Outlook of FlexiOutdoor Case
Two FPH800 Capable per FOC
“Zero Footprint” with FOC
22 © Nokia Siemens Networks Presentation / Author / DateFor internal use
USB Key makes equipment replacement convenient
• Small size, standardized components, convenient to carry and purchase
• Through NMS or Web LCT the load/ configuration of IDU and ODU can be:
• Easily back-up into the USB key manually
• Easily updated to the new replacement from the failed one
• USB key is not mandatory and the equipment can work normally without USB key
• Small size, standardized components, convenient to carry and purchase
• Through NMS or Web LCT the load/ configuration of IDU and ODU can be:
• Easily back-up into the USB key manually
• Easily updated to the new replacement from the failed one
• USB key is not mandatory and the equipment can work normally without USB key
Pull USB Key outPull USB Key out
Plug in USB KeyPlug in USB Key
12
3 Old system configuration is copied to new equipment by USB Key, so the equipment
can be restored very quickly!
Features of USB Key
Convenient and Quick Maintenance with USB Key
Fault
OK!
23 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Convenient Web LCT for local management
• Wizard function, convenient
to configure
• Alarm and event monitor and
report
• Support software upgrade
• Remote ODU management
• No software install needed
• Automatically synchronize with
NE
• Wizard function, convenient
to configure
• Alarm and event monitor and
report
• Support software upgrade
• Remote ODU management
• No software install needed
• Automatically synchronize with
NE
Internet
Features of Web LCT
Web LCT Environment
Outlook of FlexiPacket Hub 800 Web LCT
Wizard Function
24 © Nokia Siemens Networks Presentation / Author / DateFor internal use
FPRFPR
FM200FM200
FPH800FPH800
MWR2941MWR2941
NetAct Transport
NAT Connectivity
Cisco76xx
Hit7xxxTellabs 86xx
Cisco76xx
Access layer
Aggregation layer Core layer
NetAct/NetViewer Transport Network ManagementNetAct / NetViewer
Feature HighlightMBH E2E Management
NAT/NV Transport Release Plan
2010 2011R2.04/11Hub800
R2.510/11
R1.0Q2/10
R1.4Q2/11
R1.17/10
R1.29/10
R1.3Q1/11Commissioning Tool
R10.1Q1/10 R10.1 EP1 PT
7/10R10.24/11
NV
R6.0 EP11/11
R6.0 EP21/11NAT
R10.2 PT2/11
R6.0 EP34/11
R7.07/11
R10.1 EP112/10
R7.0 EP2Q4/11
R10.3Q3/11 10.4
Q4/11
NetViewer manages MWR network:•ODU + IDU•Path management/planning•E2E service provisioning•Fault management/performance managementNetAct manages whole transport network• Access• Aggregation• Core
25 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Commission Tool makes firstly Equipment Installation easier
• Easy equipment installation
• Friendly user interface, easy to operate
• No need frequently configure the IP address of serial port and NM port during installation
• Support navigation function
• Easy equipment installation
• Friendly user interface, easy to operate
• No need frequently configure the IP address of serial port and NM port during installation
• Support navigation function
ODU main
ODU Stand-By
ODU main
ODU Stand-By
Features of Commission Tool Outlook of FPH800 Commission Tool
FPH800 Commission Tool Use Environment
26 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Thanks for your time !!!
Contact for more:
MWT Shanghai R&D gives prompt and full technical support!
Win Together !!
Share folder for MicroWave Transport:https://inside.nokiasiemensnetworks.com/global/Work/Sales/Sales_Materials/BCS_Sales_Material/subdomain%20WCS/Pages/SSM_BCS_MW.aspx
Title: Head of NSN MWT Shanghai site
Email: [email protected]
Title: Head of NSN MWT Shanghai site SA
Email: [email protected]
Tel: 021-60855150
NSN IP: 8184150
Title: Program Manager of FPH800
Email: [email protected]
Tel: 021-60855125
NSN IP: 8184125