Top Banner
Formaldehyde Monitoring Presented by Michael D. Shaw
32

Formaldehyde Monitoring Presented by Michael D. Shaw.

Dec 23, 2015

Download

Documents

Amberlynn Moore
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Formaldehyde Monitoring Presented by Michael D. Shaw.

Formaldehyde Monitoring

Presented by

Michael D. Shaw

Page 2: Formaldehyde Monitoring Presented by Michael D. Shaw.

FORMALDEHYDE

Page 3: Formaldehyde Monitoring Presented by Michael D. Shaw.

HEALTH EFFECTS

Page 4: Formaldehyde Monitoring Presented by Michael D. Shaw.

CARCINOGENICITY

EPA—“B1” Probable human carcinogen

ACGIH—“A2” Suspected human carcinogen

WHO (IARC)—“Group 1” Carcinogenic to humans

Page 5: Formaldehyde Monitoring Presented by Michael D. Shaw.

PHYSICAL SYMPTOMS

1-10 ppm—Eye irritation; lacrimation at 4 ppm

10-20 ppm—Coughing, heart palpitations, tight feeling in chest

50-100 ppm and above—Pulmonary edema, pneumonitis, death

Contact with skin (formalin or HCHO-containing resins)—Dermatitis

Male single oral ingestion 517 mg/kg (DHHS)

Minimum Fatal Dose Level —

Page 6: Formaldehyde Monitoring Presented by Michael D. Shaw.

OCCUPATIONAL EXPOSURE STANDARDS

ACGIH TLV®

0.3 ppm (Ceiling)

OSHA PEL

0.75 ppm (TWA)2 ppm (Ceiling)

NIOSH REL

0.016 ppm (TWA)0.1 ppm (Ceiling)

Page 7: Formaldehyde Monitoring Presented by Michael D. Shaw.

NIOSH ANALYTICAL METHODS

Page 8: Formaldehyde Monitoring Presented by Michael D. Shaw.

Method 2016 most sensitive

Silica gel/2,4-dinitrophenylhydrazine

Method 2541

Sorbent tube/2-hydroxymethyl piperidine

(1,8-dihydroxynaphthalene-3,6-disulfonic acid)

Impinger/chromotropic acid

Method 3500

Page 9: Formaldehyde Monitoring Presented by Michael D. Shaw.

INSTRUMENT METHODS—PRACTICAL AND OTHERWISE

FTIR

Semi-automated wet chemical methods

Electrochemical (converted alcohol detectors)

Interscan purpose-designed HCHO sensor

Page 10: Formaldehyde Monitoring Presented by Michael D. Shaw.

INTERSCAN FORMALDEHYDE SENSOR

Page 11: Formaldehyde Monitoring Presented by Michael D. Shaw.

ADVANTAGES

Good sensitivity

0-500 parts-per-billion full scale measuring range available

Excellent specificity

Little effect from alcohols

Full interference info on gasdetection.com website

Quick response time

Rise time to 50%

Rise time to 90% 30-45 seconds

5-10 seconds

Page 12: Formaldehyde Monitoring Presented by Michael D. Shaw.

APPLICATIONS

HCHO ubiquitous in the workplace, however…

Biggest applications have been in the forest products industry

e.g., monitoring of emissions from manufactured wood products

Page 13: Formaldehyde Monitoring Presented by Michael D. Shaw.

Interscan’s HCHO sensor is the heart of Georgia Pacific’s

DYNAMIC MICROCHAMBER

Board compliance testing time reduced from 2 weeks to less than an hour

Page 14: Formaldehyde Monitoring Presented by Michael D. Shaw.
Page 15: Formaldehyde Monitoring Presented by Michael D. Shaw.
Page 16: Formaldehyde Monitoring Presented by Michael D. Shaw.

MONITORING PRODUCTSOFFERED BY

Page 17: Formaldehyde Monitoring Presented by Michael D. Shaw.

PORTABLE ANALYZER

Page 18: Formaldehyde Monitoring Presented by Michael D. Shaw.

CONTINUOUS MONITORING SYSTEMSINGLE POINT APPLICATION

Page 19: Formaldehyde Monitoring Presented by Michael D. Shaw.

CONTINUOUS MONITORING SYSTEMTWO POINT APPLICATION

Page 20: Formaldehyde Monitoring Presented by Michael D. Shaw.

CONTINUOUS MONITORING SYSTEMMULTI-POINT (THREE OR MORE) APPLICATION

Page 21: Formaldehyde Monitoring Presented by Michael D. Shaw.

ARC-MAX® DATA ACQUISITION, ARCHIVING,

AND REPORTING

Page 22: Formaldehyde Monitoring Presented by Michael D. Shaw.

ARC-MAX® MAIN SCREEN

Page 23: Formaldehyde Monitoring Presented by Michael D. Shaw.

ARC-MAX® SHIFT REPORT

Page 24: Formaldehyde Monitoring Presented by Michael D. Shaw.

ARC-MAX® TRENDING

Page 25: Formaldehyde Monitoring Presented by Michael D. Shaw.

ARC-MAX® ALARM LOG

Page 26: Formaldehyde Monitoring Presented by Michael D. Shaw.

For Survey Applications,We Recommend Our Nomad Data Logger

16-bit resolution

Models available for voltage and 4-20mA inputs

Self-contained units also available for temperature, humidity and pH

Sampling rate adjustable—1 second to 10 hours in 1 second intervals

Storage capacity—522,240 readings

Excellent software included

Page 27: Formaldehyde Monitoring Presented by Michael D. Shaw.

Visualize your measurement session with an auto-scaling time history graph

Page 28: Formaldehyde Monitoring Presented by Michael D. Shaw.

Time history graph detail screen

Zoomed in on particular portion of the curve

Page 29: Formaldehyde Monitoring Presented by Michael D. Shaw.

Ability To View All Individual Data Points

Page 30: Formaldehyde Monitoring Presented by Michael D. Shaw.
Page 31: Formaldehyde Monitoring Presented by Michael D. Shaw.

CONCLUDING REMARKS

We've covered the health effects and occupational standards for formaldehyde

We've looked at wet chemical and instrumental methods for formaldehyde

We've seen a special application of Interscan's HCHO sensor

Page 32: Formaldehyde Monitoring Presented by Michael D. Shaw.

SPECIAL THANKS TO

PROFESSOR GEORGE BYRNS

the Prairie Section of the American Industrial Hygiene Association

and