1/8"=1'-0" S# # S# # S201 1 SYMBOL LEGEND FOUNDATION PLAN ALT ALTERNATE BOT BOTTOM BR BRACKET BTW BETWEEN B/W BOTH WAYS BLL BOTTOM LOWER LAYER BUL BOTTOM UPPER LAYER C/W COMPLETE WITH CL CENTRELINE C/C CENTRE TO CENTRE CIP CAST IN PLACE CMU CONCRETE MASONRY UNIT DL DEAD LOAD LL LIVE LOAD SL SNOW LOAD E/E EACH END E/F EACH FACE E/S EACH SIDE E/W EACH WAY H1E HOOK ONE END H2E HOOK TWO ENDS H & V HORIZONTAL AND VERTICAL HOR HORIZONTAL GALV HOT DIPPED GALVANIZED MAX. MAXIMUM MIN. MINIMUM N.T.S. NOT TO SCALE O/C ON CENTER R/W REINFORCED WITH S.D.L. SUPERIMPOSED DEAD LOAD SIM. SIMILAR S.O.G. SLAB ON GRADE STAG. STAGGER S.J. STRUT JOIST TYP. TYPICAL T/O TOP OF T1E TIE ONE END T & B TOP AND BOTTOM T & C TENSION AND COMPRESSION U.N.O. UNLESS NOTED OTHERWISE U/S UNDER SIDE OF VERT. VERTICAL ELEVATION REFERENCE MARKER DRAWING SHEET REFERENCE MARKER NORTH ARROW REFERENCE MARKER SECTION MARKER (MEANS SECTION # SHOWN ON DRAWING SHEET S#) PLAN DETAIL REFERENCE MARKER (MEANS DETAIL # SHOWN ON DRAWING SHEET S#) T/O CONCRETE EL. 100'-0" GENERAL NOTES 1. THIS SET OF DRAWINGS SHOWS THE COMPLETED PROJECT. IT IS TO BE READ IN CONJUNCTION WITH THE NON-STRUCTURAL DRAWING SETS. IT DOES NOT INCLUDE COMPONENTS THAT MAY BE NECESSARY FOR CONSTRUCTION SAFETY. THE CONTRACTOR IS RESPONSIBLE FOR SAFETY IN AND ABOUT THE JOB SITE DURING CONSTRUCTION, AND THE DESIGN AND ERECTION OF ALL TEMPORARY STRUCTURES. FORM WORK, FALSE WORK, SHORING, ETC. REQUIRED TO COMPLETE THE WORK. 2. THE USE OF THESE DRAWINGS IS LIMITED TO THAT IDENTIFIED IN THE REVISIONS COLUMN. DO NOT CONSTRUCT FROM THESE DRAWINGS UNLESS MARKED "ISSUED FOR CONSTRUCTION" IN THE REVISIONS COLUMN BY JDB PROJECT ENGINEERING. 3. THE INFORMATION ON THIS DRAWING SHALL NOT BE USED FOR ANYTHING OTHER THAN THE SPECIFIED WORKS OR PART OF THE WORKS FOR WHICH IT HAS BEEN AUTHORIZED BY JDB PROJECT ENGINEERING. 4. SEE CIVIL AND MECHANICAL AND ELECTRICAL DRAWINGS FOR ELEVATIONS, RECESSES, DRAINAGE SLOPES, DETAILED DIMENSIONS FOR PIPE PENETRATIONS AND OTHER OPENINGS, SLEEVES, NAILERS, INSERTS, ETC. TO BE ENCASED IN CONCRETE ETC. 5. THE CONTRACTOR SHALL REVIEW ALL THE DRAWINGS AND CHECK DIMENSIONS BEFORE CONSTRUCTION. REPORT DISCREPANCIES BETWEEN STRUCTURAL AND OTHER DISCIPLINES DRAWINGS FOR CLARIFICATION. 6. THE CONTRACTOR SHALL REPORT ANY SITE MODIFICATIONS MADE DURING CONSTRUCTION, THAT DIFFER FROM THE STRUCTURAL DRAWINGS, TO JDB PROJECT ENGINEERING FOR REVIEW 7. DO NOT CUT OR DRILL ANY OPENINGS IN STRUCTURAL MEMBERS WITHOUT THE WRITTEN PERMISSION OF JDB PROJECT ENGINEERING. CONTRACTOR TO PROVIDE APPROPRIATE ATTACHMENTS AND CONNECTIONS FOR MECHANICAL, ELECTRICAL, AND OTHER SERVICES WITHOUT CUTTING OR DRILLING. 8. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL DRAWINGS FOR LOCATIONS, CONFIGURATIONS, EXTENT, AND SIZES OF ALL CURBS, UPSTANDS, DOWNTURNS: AND FOR OPENINGS THROUGH FLOORS AND WALLS FOR DUCTS. 9. THE CONTRACTOR SHALL BE FAMILIAR WITH THE CONTENT AND RECOMMENDATIONS OF THE GEOTECHNICAL REPORTS. 10. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL STRUCTURAL COMPONENTS TO JDB PROJECT ENGINEERING FOR REVIEW PRIOR TO FABRICATION. SHOP DRAWINGS ARE TO INCLUDE SEAL AND SIGNATURE OF A PROFESSIONAL ENGINEER, REGISTERED IN THE PROJECT PROVINCE, FOR DESIGN OF COMPONENTS AND/OR CONNECTIONS AS REQUIRED. OWNERSHIP AND COPYRIGHT RESERVED 1. ALL DRAWINGS, PLANS, MODELS, DESIGNS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY JDB PROJECT ENGINEERING. AND USED IN CONNECTION WITH THE PROJECT ARE INSTRUMENTS OF SERVICE FOR THE EXECUTION OF THE PROJECT, AND ARE AND WILL REMAIN THE PROPERTY OF JDB PROJECT ENGINEERING, WHETHER THE PROJECT IS EXECUTED OR NOT. JDB PROJECT ENGINEERING. RESERVES THE COPYRIGHT THEREIN AND IN THE WORK EXECUTED THEREFROM: SHALL NOT BE USED FOR ANY OTHER PROJECT. EXCEPT ONLY FOR GENERAL REFERENCE PURPOSES FOR ADDITION OF ALTERATION TO THE WORK SHOWN IN THEM, AND SINCE SUCH DOCUMENTS ARE "DESIGN" DOCUMENTS ONLY AND MAY NOT REPRESENT THE ACTUAL PROJECT "AS CONSTRUCTED", USE OF THESE DOCUMENTS FOR GENERAL REFERENCE PURPOSES IS AT THE SOLE RISK OF THE PARTY USING THEM: THEY SHALL NOT BE COPIED WITHOUT THE WRITTEN CONSENT OF AN AUTHORIZED REPRESENTATIVE OF JDB PROJECT ENGINEERING. REVIEW BY JDB PROJECT ENGINEERING. 1. THE CONTRACTOR SHALL PROVIDE REASONABLE NOTICE TO JDB PROJECT ENGINEERING. PRIOR TO POURING CONCRETE OR CONCEALING ANY STRUCTURAL COMPONENTS. THE PURPOSE OF THIS NOTICE IS TO ENABLE JDB PROJECT ENGINEERING. TO CONDUCT ANY REQUIRED FIELD REVIEWS. 2. JDB PROJECT ENGINEERING. PROVIDES FIELD REVIEW ONLY FOR THE WORK SHOWN ON THESE STRUCTURAL DRAWINGS. THIS REVIEW IS NOT A "FULL TIME" REVIEW BUT IS A PERIODIC REVIEW AT THE SOLE DISCRETION OF JDB PROJECT ENGINEERING'S ENGINEER IN ORDER TO VISUALLY ASCERTAIN THAT THE WORK IS IN GENERAL CONFORMANCE WITH THE PLANS AND SUPPORTING DOCUMENTS PREPARED BY JDB PROJECT ENGINEERING. FIELD REVIEW BY JDB PROJECT ENGINEERING. IS NOT CARRIED OUT FOR THE CONTRACTOR'S BENEFIT, NOR DOES IT MAKE JDB PROJECT ENGINEERING. GUARANTORS OF THE CONTRACTORS WORK. IT REMAINS THE CONTRACTOR'S RESPONSIBILITY TO BUILD THE WORK IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. NEITHER ENGINEER NOR JDB PROJECT ENGINEERING SHALL BE RESPONSIBLE FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 3. JDB PROJECT ENGINEERING. WILL REVIEW SHOP DRAWINGS PERTAINING TO WORK SHOWN ON THE CONTRACT DOCUMENTS. THE EXTENT OF THIS REVIEW IS AT THE SOLE DISCRETION OF JDB PROJECT ENGINEERING'S ENGINEER AND IS FOR THE SOLE PURPOSE OF ASCERTAINING GENERAL CONFORMANCE WITH THE STRUCTURAL DESIGN CONCEPT. THE REVIEW IS NOT AN APPROVAL OF THE DESIGN, DETAILS AND DIMENSIONS INHERENT IN THE SHOP DRAWINGS, THE RESPONSIBILITY FOR WHICH SHALL REMAIN WITH THE CONTRACTOR SUBMITTING THEM. SUCH REVIEW SHALL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY FOR ERRORS AND OMISSIONS IN THE SHOP DRAWINGS OR FOR MEETING ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS. ABBREVIATIONS PROJECT NORTH TUL TOP UPPER LAYER TLL TOP LOWER LAYER OSF OUTSIDE FACE ISF INSIDE FACE DESIGN CRITERIA THE DESIGN OF THE STRUCTURE IS IN ACCORDANCE WITH PART 9 OF DIVISION B NBCC 2010 AND THE 2011 MANITOBA BUILDING CODE. IMPORTANCE CATEGORY NORMAL SNOW DESIGN DATA Ss = 1.9 kPa (39.7psf) Sr = 0.2 kPa (4.2 psf) Is = 1.0 ULS / 0.9 SLS WIND DESIGN DATA 0.45 kPa (9.4 psf) q(1/50) 0.35 kPa (7.3 psf) q(1/10) Iw = 1.0 ULS / 0.75 SLS SITE CLASSIFICATION FOR SEISMIC SITE RESPONSE: SITE NOT CLASSIFIED, SEISMIC DESIGN NOT REQUIRED DUE TO MB CODE AMMENDMENT REFER TO PLAN FOR DESIGN LOADING CONTRACTOR TO ENSURE THAT CONSTRUCTION LOADS DO NOT EXCEED DESIGN LOADS. STRUCTURAL MOVEMENTS/ TOLERANCES 1. THIS STRUCTURE WILL UNDERGO NORMAL TYPES OF MOVEMENT AND DEFLECTION AND THE NON-STRUCTURAL COMPONENTS MUST BE DETAILED TO ACCOMMODATE THIS. 2. DRYWALL PARTITIONS, MECHANICAL EQUIPMENT, ELECTRICAL EQUIPMENT, BUILDING FIXTURES, GLAZING AND CURTAIN WALLS MUST BE DETAILED AND INSTALLED TO ACCOMMODATE SLAB MOVEMENT. 3. ALL STRUCTURES ARE SUBJECT TO CONSTRUCTION TOLERANCES. THIS SHOULD BE ALLOWED FOR IN DETAILING NON-STRUCTURAL COMPONENTS. NON-STRUCTURAL ELEMENTS 1. "NON-STRUCTURAL" OR "SECONDARY STRUCTURAL" ELEMENTS ARE NOT THE RESPONSIBILITY OF STRUCTURAL ENGINEER. THEY ARE DESIGNED, DETAILED, AND REVIEWED IN THE FIELD BY OTHERS. THEY APPEAR ON DRAWINGS OTHER THAN THE STRUCTURAL ENGINEER. WHERE STRUCTURAL ENGINEERING RESPONSIBILITY IS REQUIRED FOR THESE ELEMENTS, THIS SHALL BE PROVIDED BY SPECIALTY STRUCTURAL ENGINEERS, WHO SHALL ALSO PROVIDE ANY CERTIFICATION REQUIRED BY BUILDING PERMIT AUTHORITIES. SPECIALTY STRUCTURAL ENGINEERS ARE TO DESIGN THESE ELEMENTS ACCORDING TO THE APPLICABLE DESIGN LOADS AS NOTED IN PART 4 OF THE MOST CURRENT NBCC. 2. EXAMPLES OF NON-STRUCTURAL OR SECONDARY STRUCTURAL ELEMENTS INCLUDE, BUT ARE NOT LIMITED TO: A. MISCELLANEOUS METALS COMPONENTS SUCH AS GUARDRAILS, HANDRAILS, HATCHES, COVERS, ETC. B. LANDSCAPE ELEMENTS SUCH AS BENCHES, LIGHT POSTS, PLANTERS, ETC. C. CLADDING, GLAZING, WINDOW MULLIONS, INTERIOR STUD WALLS AND EXTERIOR STUD WALLS. D. ARCHITECTURAL PRECAST, PRECAST CLADDING. E. MECHANICAL AND ELECTRICAL EQUIPMENT, COMPONENTS, AND THEIR ATTACHMENT DETAILS. F. ELEVATORS, ELEVATOR HOIST BEAMS, ESCALATORS, AND OTHER CONVEYING SYSTEMS. G. BRICK OR BLOCK VENEERS AND THEIR ATTACHMENTS. H. NON-LOAD BEARING MASONRY. I. NON-STRUCTURAL CONCRETE TOPPINGS J. ALUMINUM SKYLIGHTS. K. STAIRS 3. SHOP DRAWINGS FOR NON-STRUCTURAL ELEMENTS WHICH MAY AFFECT THE PRIMARY STRUCTURAL SYSTEM SHALL BE SUBMITTED TO JDB PROJECT ENGINEERING. THESE DRAWINGS WILL BE REVIEWED ONLY FOR THE EFFECT ON THE PRIMARY STRUCTURAL SYSTEM. CONCRETE 1. ALL CONCRETE CONSTRUCTION, COLD WEATHER CONSTRUCTION & CONCRETE TESTING TO BE IN ACCORDANCE WITH THE LATEST EDITION CSA STANDARDS A23.1 AND A23.2. 2. ALL CONCRETE TO BE NORMAL WEIGHT HARD ROCK CONCRETE WITH A MINIMUM 28 DAY COMPRESSIVE STRENGTH AS NOTED IN TABLE 2 OF THE LATEST EDITION CSA A23.1. 3. MAXIMUM AGGREGATE SIZE SHALL BE 19 mm (3/4") 4. CONCRETE CLASSES OF EXPOSURE (REFER TO TABLE 1, LATEST EDITION CSA A23.1): A. SLUDGE DRYING BED SLAB AND PERIMETER WALL: CLASS A-1 EXPOSURE (35 MPa @28d), MAX 0.40 WATER CEMENT RATIO, 4 TO 7% AIR CONTENT B. ALL REMAINING CONCRETE ELEMENTS: CLASS A-2 EXPOSURE (32 MPa @ 28d). MAX 0.45 WATER CEMENT RATIO, 5 TO 8% AIR CONTENT 5. CONCRETE SLUMP TO BE COORDINATED BETWEEN CONTRACTOR AND CONCRETE SUPPLIER CONSIDERING THE PERFORMANCE CRITERIA AND THE CONTRACTOR'S CRITERIA FOR CONSTRUCTION AND PLACEMENT. 6. MISCELLANEOUS CONCRETE ELEMENTS (PITS, TRENCHES, ETC,) TO BE MINIMUM 6" (150mm) THICK REINFORCED WITH 10M @ 12" (300mm) O/C EACH WAY U.N.O. 7. CONCRETE SAMPLING AND TESTING TO BE COMPLETE IN ACCORDANCE WITH THE LATEST EDITION CSA A23.1/A23.2 8. VOID FORM TO BE WAX COVERED OR POLY WRAPPED CARDBOARD. LOW DENSITY POLYSTYRENE MATERIAL IS AN ACCEPTABLE ALTERNATIVE. INFORMATION REGARDING PROPOSED PRODUCT SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY JDB PROJECT ENGINEERING PRIOR TO COMMENCEMENT OF EXCAVATION AND FORMWORK EXPOSURE CONDITION EXPOSURE CLASS N F-1, F-2, S-1, S-2, S-3 C-XL, C-1, C-3, A-XL, A-1, A-2, A-3 CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH BEAMS, GIRDERS, COLUMNS, AND PILES SLABS, WALLS, JOISTS 75mm 30mm 20mm 40mm 40mm 75mm 60mm 60mm 75mm REINFORCING 1. REINFORCING STEEL SHALL BE GRADE 400 DEFORMED NEW BILLET STOCK CONFORMING TO THE LATEST EDITION OF CSA SPECIFICATION G30.18. WELDED WIRE MESH SHALL CONFORM TO THE LATEST EDITION CSA A23.1 CLAUSE 6.1.1.1. 2. CONCRETE COVER TO BE AS PER TABLE 17 OF THE LATEST EDITION CSA A23.1 3. CONCRETE COVER FOR EXPOSURE CLASSES NOT NOTED ABOVE TO BE 40 mm. 4. TOP STEEL IN GRADE BEAMS TO BE SPLICED AT CENTER SPAN AND BOTTOM STEEL TO BE SPLICED OVER SUPPORTS. SPLICE LENGTHS: A. TENSION ZONE SPLICE TO BE AVOIDED WHEREVER POSSIBLE, BUT IF REQUIRED, LENGTH SHOULD BE SPECIFIED BY JDB PROJECT ENGINEERING. B. COMPRESSION ZONE SPLICE SHOULD NOT BE LESS THAN 30 BAR DIAMETERS. 5. CONCRETE COVER FOR FIRE RATING REQUIREMENTS AS PER CURRENT EDITION OF NBCC 6. USE OF IMPERIAL REBAR SIZES (#3, #4, #5, #6, ETC) MEETING ASTM A706 (LATEST EDITION) GRADE 60 IS ACCEPTABLE ITEMS EMBEDDED IN CONCRETE SEE ALSO LATEST EDITION CSA A23.1 EXCEPT WHEN APPROVED BY JDB PROJECT ENGINEERING., PIPES, CONDUITS, AND SLEEVES EMBEDDED IN CONCRETE SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING GUIDELINES: 1. GENERAL A. NOT WITHSTANDING THE SATISFACTION OF THESE GUIDELINES, THE CONDUIT, SLEEVES, PIPES, ETC. SHALL NOT IMPAIR THE STRUCTURAL STRENGTH AND SHALL BE MOVED IF SO DIRECTED BY JDB PROJECT ENGINEERING. B. CENTERLINE SPACING TO BE NOT LESS THAN 3 DIAMETERS. C. CENTERLINE SPACING BETWEEN PARALLEL CONDUIT AND REINFORCING BARS TO BE 3 DIAMETERS. D. ADD REINFORCING AT POINTS OF CONGESTION AS DIRECTED BY JDB PROJECT ENGINEERING. 2. FOR SLABS - CONDUITS IN THE PLANE OF THE SLAB: A. LOCATE BETWEEN TOP AND BOTTOM REINFORCING. (WHERE APPLICABLE) B. MAXIMUM SIZE IN ONE LAYER TO BE NOT MORE THAN 1/4 OF CONCRETE THICKNESS. C. THREE LAYERS OR MORE CROSSING WILL NOT BE PERMITTED. 3. FOR WALLS & SLABS - CONDUIT/ PIPES NOT ALLOWED WITHOUT THE WRITTEN APPROVAL OF JDB PROJECT ENGINEERING. WATERPROOFING ADDITIVE 1. ALL WATER RETAINING / TREATEMENT CONCRETE STRUCTURES SHALL HAVE AN INTEGRAL CRYSTALINE WATERPROOFING ADMIXTURE INCLUDED AT TIME OF CONCRETE BATCHING. 2. ADMIXTURE SHALL BE XPEX BIO-SAN C500 OR APPROVED ALTERNATE. 3. SUBMIT PRODUCT DATA SHEET AND TESTING INFORMATION TO ENGINEER AND AWAIT WRITTEN ACCEPTANCE / APPROVAL OF ALTERNATE PRIOR TO COMMENCING USE OF ALTERNATE PRODUCT. 4. WATERPROOFING ADMIXTURE SHALL BE HANDLED, STORED AND APPLIED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS / WRITTEN INSTRUCTIONS. 5. PRODUCT APPLICATIORS SHALL BE CERTIFIED BY THE MANUFACTURER WHERE APPLICABLE 6. WATERPROOFING ADDITIVE SHALL HAVE A MINIMUM 5 YEAR MANUFACTURERS WARRANTY FROM THE DATE OF SUBSTANTIAL COMPLETION PVC WATERSTOP 1. ALL CONCRETE WATER RETAINING / TREATEMENT STRUCTURES SHALL HAVE CONTINUOUS HORIZONTAL PVC WATERSTOPS PROVIDED BETWEEN BASE SLAB / WALL JOINTS AND VERTICAL WATERSTOPS PROVIDED AT ALL VERTICAL WALL POUR (COLD) JOINTS. 2. PVC WATERSTOP SHALL BE W.R. MEADOWS SEALTIGHT TYPE 4316 OR APPROVED ALTERNATE. 3. SUBMIT PRODUCT DATA SHEET AND TESTING INFORMATION TO ENGINEER AND AWAIT WRITTEN ACCEPTANCE / APPROVAL OF ALTERNATE PRIOR TO COMMENCING USE OF ALTERNATE PRODUCT. 4. FIELD SPLICE WATERSTOP ROLLS AND CUT ENDS IN ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS 5. WHERE MULTIPLE WATERSTOP ROWS ARE SPECIFIED, STAGGER SPLICES IN ADJACENT ROWS MINIMUM 18" (450 mm) UNLESS NOTED OTHERWISE ON THE PROJECT DRAWINGS FOUNDATION - (CIP GRADE SUPPORTED REINFORCED CONCRETE PADS / FOOTINGS / RAFT SLABS) 1. NO SITE SPECIFIC GEOTECHNICAL REPORT HAS BEEN PREPARED, BIDDERS SHALL FAMILIARIZE THEMSELVES WITH THE EXISTING SITE CONDITIONS INCLUDING DEPTH OF FILL MATERIAL TO BE REMOVED AS PART OF THE PROJECT SCOPE. 2. STRUCTURAL DESIGN OF REINFORCED CONCRETE AT GRADE FOOTINGS/RAFT SLABS HAS BEEN COMPLETED USING ALLOWABLE BEARING CAPACITIES AS SPECIFIED. A GEOTECHNICAL ENGINEER SHALL VERIFY THE EXISTING IN-SITU CLAY SOIL CAPACITY PRIOR TO COMMENCEMENT OF WORK TO VERIFY THAT REQUIRED BEARING CAPACITIES CAN BE REACHED. 3. REMOVE ALL ORGANIC, SOFTENED, FILL AND DELETRIOUS MATERIAL FROM ENTIRE FOOTPRINT OF PROPOSED STRUCTURE AND PROOF ROLL SUBGRADE TO IDENTIFY SOFT AREAS. 4. SOFT AREAS SHALL BE SUB-EXCAVATED TO COMPETENT SOIL STRATA AND SITE SHALL BE BROUGH BACK UP TO DESIGN ELEVATION USING NON-WOVEN GEOTEXTILE AND 3/4" DOWN COMPACTED ANGULAR OR SUB-ANGULAR GRANULAR MATERIAL PLACED IN 6" LIFTS AND COMPACTED TO A MINIMUM OF 100% STANDARD PROCTOR. 5. PROTECT EXCAVATED SUBGRADE FROM FREEZING, DRYING AND FROM INUNDATION AS A RESULT OF RAIN AND WATER RUNOFF TO PREVENT SOFTENING OF SUBGRADE MATERIAL PRIOR TO PLACEMENT OF BASE SLAB CONCRETE. 6. COMPACTED GRANULAR MATERIAL BELOW THE FOUNDATION SHALL EXTEND BEYOND ALL CAST IN PLACE FOUNDATION EDGES IN PLAN BY A MINIMUM DISTANCE EQUAL TO THE GRAVEL THICKNESS. 7. FOUNDATION ELEMENTS SHALL BE PROVIDED WITH EQUIVALENT 8 FEET (2.4 METERS) FROST PROTECTION THROUGH A COMBINATION OF SOIL COVER AND RIGID INSULATION PLACED UNDER, ON THE EXTERIOR VERTICAL EDGES, AND HORIZONTALLY AROUND THE EXTERIOR EDGES. PRIMARY FLEXURAL REINF. TOP & BOT. EXTEND PRIMARY FLEXURAL REINF. INTO PERPENDICULAR MEMBER AS SHOWN. 2' - 0" 2' - 0" 15M x4' - 0" LONG CORNER BARS TYP. PRIMARY FLEXURAL REINF. TOP & BOT. EXTEND PRIMARY FLEXURAL REINF. INTO PERPENDICULAR MEMBER AS SHOWN. 2' - 0" 2' - 0" 15M x4' - 0" LONG CORNER BARS TYP. jdb project engineering inc. 1-880L - 15TH STREET, WINKLER, MB R6W 0H5 PH: (204) 331-4440 EMAIL: [email protected] TITLE: DRAWING NO: SCALE: DRAWN BY: DESIGNED BY: REVIEWED BY: PROJECT NO: DATE: SHEET NO: FOR TENDER ONLY NOT FOR CONSTRUCTION PROJECT: As indicated S001 GENERAL NOTES 20-079 2021-05-14 DP DP jdb 095 SELKIRK SLUDGE DRYING BEDS CITY OF SELKIRK 200 Eaton Avenue, Selkirk, MB R1A 0W6 204-785-4900 1 : 20 S001 2 TYPICAL CORNER BAR DETAIL LIST OF STRUCTURAL DRAWINGS NUMBER DRAWING TITLE S001 GENERAL NOTES S101 FOUNDATION SLAB PLAN AND DETAILS S301 CROSS SECTIONS AND DETAILS REVISION ISSUED FOR DATE 1 ISSUED FOR TENDER ONLY 2021-05-14