Page 1: For multi-unit restorations - conventional or digital

» For multi-unit restorations - conventional or digital «

Multi-unitAbutMents

Page 2: For multi-unit restorations - conventional or digital

2

The Multi-unit product range

is being contiunally expanded to

include other abutment series.

* is a registered trademark of an independent third party** is a product name of an independent third party

Page

3 Multi-unit Instruction Manual

14 CF-Series compatible with Nobel Biocare NobelActive®*

NobelReplace® Conical*

17 CH-Series compatible with BIOMET 3i Certain®*

20 CL-Series compatible with Straumann Bone Level**

23 CN-Series compatible with Straumann Tissue Level**

25 CR-Series compatible with Zimmer Dental Screw-Vent®*

MIS SEVEN Internal Hex**

BioHorizons Tapered Internal**

Tapered Internal Plus**

Tapered Tissue Level**

29 CV-Series compatible with Dentsply Implants ASTRA TECH OsseoSpeed EV**

Available for a large number of implant systems:

Page 3: For multi-unit restorations - conventional or digital

3

* is a registered trademark of an independent third party

Implant with conventional shoulder and straight abutment

Implant with conventional shoulder and 30° angled abutment

The Multi-unit abutment supports a variety of prosthetic restorations. It is ideal for creating patient oriented individual hybrid restorations or being the base for an individualized restoration according to the “All-on-4”* principle.

» Multi-unit abutment «

Page 4: For multi-unit restorations - conventional or digital

4

* is a registered trademark of an independent third party

Multi-unit abutmentangled 30°

Multi-unit abutment

straight

All Multi-unit abutments are supplied with the insertion aid.

Multi-unit titanium baseincl. bridge screw

The “All-on-4”* principle for atrophic ridges allows for a comprehensive treat-ment plan for edentulous patients by providing a full-arch immediate restora-tion, using just two straight and two 30° angulated implants.

The temporary restoration is immediately placed over the implants using the Multi-unit abutments.

The straight and 30° angled Multi-unit abutments allow for a common insertion direction for the prosthetic restoration.

» The “All-on-4” principle* «

Page 5: For multi-unit restorations - conventional or digital

5

Full denture

A provisional full denture is sufficiently worked out in the area of the titanium bases and then tension free inserted in the denture on the model and / or in the mouth.

Final bridge restoration on two implants in the posterior region

A metal framework is sufficiently worked out in the area of the titanium bases and then orally glued without tension. Next exists the possibility of making the framework by means of directly cast on the gold caps or CoCr caps. After final construction the bridge will be screwed occlusally.This procedure is also suitable for the preparation of a final full arch resoration on at least four implants in the lower jaw or six implants in the upper jaw.

bar with removable full denture

A casted or CAD CAM milled bar is screwed on Multi-Unit abutments. Afterwards, depending on the indication and patient request, the fi-nal removable denture can be manufactured.

• Paste the titanium base into the denture to create a temporary restoration.• The framework production of superstructures by means of castable CoCr caps

or castable gold caps.• CADCAM milled bars or bridges.• “All-on-4”* treatment concept.

» There are various possibilities for prosthetic restorations «

Multi-unit abutmentangled 30°

* is a registered trademark of an independent third party

Page 6: For multi-unit restorations - conventional or digital

6

GH 1 GH 1GH 2 GH 2 GH 1

0° 30°17°

» Multi-unit abutments «

» Determination of the gingival height «

treatment optionsThere are various prosthetic components for different treatment options.

Gingiva height The Multi-unit abutments are available in 3 different gingival heights.

implant connection Available with implant connections to most popular implant manufacturers.

The gingiva height stated in the catalogue is marked here as GH1.With the two angled abutments GH2 is calculated as shown:

GH 2 = GH 1 - 1.4 mm GH 2 = GH 1 - 2.4 mm

Page 7: For multi-unit restorations - conventional or digital

7

treatment optionsThere are various prosthetic components for the different treatment otions.

Gingiva height The Multi-unit abutments are available in 3 different gingival heights.

implant connection Compatible to most popular implant connections.

two angulations The Multi-unit abutments are available with 17° and 30°angulation.

Angulation Variant Gingiva height (GH)*

straight

low

medium

high

17°

Type 1: over flat Type 2: over corner low

medium

high

30°

Type 1: over flat Type 2: over corner low

medium

high

*Exact lengths depend on the implant system

Page 8: For multi-unit restorations - conventional or digital

8

Castable gold capto cast

gold alloys

Castable CoCr capto cast

non-precious metals

bridge screwincluded with every cap and the titanium base

titanium base to glue into the bridge/denture

(passive fit)

titanium cap to shorten and glue into the bridge or

denture as well as to create temporary restorations

Modelling aid for modelling on the titanium cap or titanium base

only usable in combination with the titanium base or titanium cap

» Multi-unit prosthetic components «

Page 9: For multi-unit restorations - conventional or digital

9

bridge screwincluded with every cap and the titanium base

titanium base to glue into the bridge/denture

(passive fit)

Multi-unit lab analog for CADCAM for use with digital model production (print model)

Multi-unit scanbody straightfor digital impression of the

straight Multi-unit abutments

Multi-unit scanbody angled

for digital impression of theangled Multi-unit

abutments 17° and 30°

titanium cap to shorten and glue into the bridge or

denture and to create temporary restorations

» Multi-unit prosthetic componentsfor digital restorations «

Page 10: For multi-unit restorations - conventional or digital

10

straight Multi-unit analogfor use with conventional

model production.

Angled Multi-unit analogfor use with conventional model production. Angled 17° & 30°.

straight Multi-unit analog for CADCAM for use with digital model production (print model).

Angled Multi-unit analog for CADCAM for use with digital model production

(print model). Angled 17° & 30°.

» Lab Analogs for Multi-unit abutments «

Page 11: For multi-unit restorations - conventional or digital

11

21° 30°

51° 51°

102°

» Multi-unit divergency compensation «

The Multi-unit abutments have a uniform platform to the prosthetic components with a conicity of 21° (one-sided).

When using the 30° angled Multi-unit abutments divergencies of up to 102° between implants can be covered. This results due to the 30° angulation of the multi-unit abutments and the conicity of the 21° platform.

impression coping for impression of the Multi-unit abutments.

Cover cap to protect the abutments during the healing phase.

Placement instrument used to torque the straight Multi-unit

abutments.

» Multi-unit accessories «

Page 12: For multi-unit restorations - conventional or digital

12

1 2 3 4

All Multi-unit abutments are supplied with the insertion aid.

» How to use «Multi-unit abutment straightAfter the implant placement, the Multi-unit abutment straight is connected to the implant with its special insertion aid and tightened with the insertion tool up to the recommended torque.

Page 13: For multi-unit restorations - conventional or digital

13

1 2 3

All Multi-unit abutments are supplied with the insertion aid.

» How to use «Multi-unit abutment angledAfter the implant placement, the angulated Multi-unit abutment is connected to the implant with its special insertion aid and tightened with the screw up to the recommended torque.

Page 14: For multi-unit restorations - conventional or digital

14 » CF-SERIES « Nobel Biocare® NobelActive® / NobelReplace® Conical

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 35 Ncm

Implant connection NP 3.5 NP 3.5 NP 3.5Gingiva height 1.5 mm 3.5 mm 5.5 mmArticle No. CF 8000 CF 8001 CF 8002

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 35 Ncm

Implant connection RP 4.3/5.0 RP 4.3/5.0 RP 4.3/5.0Gingiva height 1.5 mm 3.5 mm 5.5 mmArticle No. CF 8010 CF 8011 CF 8012

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 35 Ncm

Type 1

Implant connection NP 3.5 NP 3.5 NP 3.5Gingiva height 2.5 mm 3.5 mm 5.5 mmArticle No. CF 8100 CF 8101 CF 8102Abutment screw CF 600 CF 600 CF 600

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 35 Ncm

Type 1

Implant connection NP 3.5 NP 3.5 NP 3.5Gingiva height 3.0 mm 4.0 mm 5.5 mmArticle No. CF 8300 CF 8301 CF 8302Abutment screw CF 600 CF 600 CF 600

Page 15: For multi-unit restorations - conventional or digital

15» CF-SERIES « Nobel Biocare® NobelActive® / NobelReplace® Conical

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 35 Ncm

Type 1

Implant connection RP 4.3/5.0 RP 4.3/5.0 RP 4.3/5.0Gingiva height 2.5 mm 3.5 mm 5.5 mmArticle No. CF 8110 CF 8111 CF 8112Abutment screw CF 601 CF 601 CF 601

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 35 Ncm

Type 1

Implant connection RP 4.3/5.0 RP 4.3/5.0 RP 4.3/5.0Gingiva height 3.0 mm 4.0 mm 5.5 mmArticle No. CF 8310 CF 8311 CF 8312Abutment screw CF 601 CF 601 CF 601

Multi-unit prosthetic components•CF 8501 Multi-unit bridge screw UG•CF 8508 Multi-unit titanium base

incl. bridge screw•CF 8505 Multi-unit titanium cap

incl. bridge screw•CF 8506 Multi-unit gold cap,

castable incl. bridge screw•CF 8507 Multi-unit CoCr cap incl.

bridge screw•Recommended torque: 15 Ncm

Material Titanium grade 5 CF

Titanium grade 5 CF

Titanium grade 5 CF

"(AU 60%; Pd 20%; Pt 19%;

Ir 1%)"

CrCo alloy / CTE 14.1

Article No. CF 8501 CF 8508 CF 8505 CF 8506 CF 8507

Multi-unit modelling sleeve•Tecanat (PC)

Article No. 8510Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and

Multi-unit titanium cap.

Multi-unit scanbody•Titanium grade 5 CF specially

coated•incl. bridge screw

Version straight angledArticle No. CF 8500 CF 8513Please note: The Scanbody is sterilisable for intra-oral scanning.

Page 16: For multi-unit restorations - conventional or digital

16 » CF-SERIES « Nobel Biocare® NobelActive® / NobelReplace® Conical

Multi-unit Laboratory implant•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8504 8514-17 8514-30

Multi-unit Laboratory implant CADCAM•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8509 8515-17 8515-30

Multi-unit accessories•CF 8502 Multi-unit cover cap•CF 8503 Multi-unit open tray

impression coping•M 11-11 Placement instrument

Multi-unit abutment•8515 T Placement instrument

laboratory implant CADCAM Article No. CF 8502 CF 8503 M 11-11 8515 T

Page 17: For multi-unit restorations - conventional or digital

17» CH-SERIES « Biomet 3i® Certain®

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 20 Ncm

Implant connection D 3.4 D 3.4 D 3.4Gingiva height 1.0 mm 3.0 mm 5.0 mmArticle No. CH 8000 CH 8001 CH 8002

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 20 Ncm

Implant connection D 4.1 D 4.1 D 4.1Gingiva height 1.0 mm 3.0 mm 5.0 mmArticle No. CH 8010 CH 8011 CH 8012

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 20 Ncm

Type 1

Implant connection D 3.4 D 3.4 D 3.4Gingiva height 2.0 mm 3.0 mm 5.0 mmArticle No. CH 8100 CH 8101 CH 8102Abutment screw CH 62 CH 62 CH 62

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 20 Ncm

Type 1

Implant connection D 3.4 D 3.4 D 3.4Gingiva height 3.0 mm 4.0 mm 5.0 mmArticle No. CH 8300 CH 8301 CH 8302Abutment screw CH 62 CH 62 CH 62

Page 18: For multi-unit restorations - conventional or digital

18 » CH-SERIES « Biomet 3i® Certain®

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 20 Ncm

Type 1

Implant connection D 4.1 D 4.1 D 4.1Gingiva height 2.0 mm 3.0 mm 5.0 mmArticle No. CH 8110 CH 8111 CH 8112Abutment screw CH 62 CH 62 CH 62

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 20 Ncm

Type 1

Implant connection D 4.1 D 4.1 D 4.1Gingiva height 3.0 mm 4.0 mm 5.0 mmArticle No. CH 8310 CH 8311 CH 8312Abutment screw CH 62 CH 62 CH 62

Multi-unit prosthetic components•CH 8501 Multi-unit bridge screw

Hex 1.2•CH 8508 Multi-unit titanium base

incl. bridge screw•CH 8505 Multi-unit titanium cap

incl. bridge screw•CH 8506 Multi-unit gold cap,

castable incl. bridge screw•CH 8507 Multi-unit CoCr cap incl.

bridge screw•Recommended torque: 15 Ncm

Material Titanium grade 5 CF

Titanium grade 5 CF

Titanium grade 5 CF

"(AU 60%; Pd 20%; Pt 19%;

Ir 1%)"

CrCo alloy / CTE 14.1

Article No. CH 8501 CH 8508 CH 8505 CH 8506 CH 8507

Multi-unit modelling sleeve•Tecanat (PC)

Article No. 8510Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and

Multi-unit titanium cap.

Multi-unit scanbody•Titanium grade 5 CF specially

coated•incl. bridge screw

Version straight angledArticle No. CH 8500 CH 8513Please note: The Scanbody is sterilisable for intra-oral scanning.

Page 19: For multi-unit restorations - conventional or digital

19» CH-SERIES « Biomet 3i® Certain®

Multi-unit Laboratory implant•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8504 8514-17 8514-30

Multi-unit Laboratory implant CADCAM•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8509 8515-17 8515-30

Multi-unit accessories•CH 8502 Multi-unit cover cap•CH 8503 Multi-unit open tray

impression coping•M 11-11 Placement instrument

Multi-unit abutment•8515 T Placement instrument

laboratory implant CADCAM Article No. CH 8502 CH 8503 M 11-11 8515 T

Page 20: For multi-unit restorations - conventional or digital

20 » CL-SERIES « Straumann® Bone Level®

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 35 Ncm

Implant connection NC 3.3 NC 3.3 NC 3.3Gingiva height 1.5 mm 3.5 mm 5.5 mmArticle No. CL 8000 CL 8001 CL 8002

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 35 Ncm

Implant connection RC 4.1/4.8 RC 4.1/4.8 RC 4.1/4.8Gingiva height 1.5 mm 3.5 mm 5.5 mmArticle No. CL 8010 CL 8011 CL 8012

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Type 2 = angled over corner•Recommended torque: 35 Ncm

Type 1

Type 2 Implant connection NC 3.3 NC 3.3 NC 3.3Gingiva height 2.5 mm 3.5 mm 5.5 mmArticle No. Type 1 CL 8100 CL 8101 CL 8102Article No. Type 2 CL 8200 CL 8201 CL 8202Abutment screw CL 65 CL 65 CL 65

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Type 2 = angled over corner•Recommended torque: 35 Ncm

Type 1

Type 2 Implant connection NC 3.3 NC 3.3 NC 3.3Gingiva height 3.0 mm 4.0 mm 5.5 mmArticle No. Type 1 CL 8300 CL 8301 CL 8302Article No. Type 2 CL 8400 CL 8401 CL 8402Abutment screw CL 65 CL 65 CL 65

Page 21: For multi-unit restorations - conventional or digital

21» CL-SERIES « Straumann® Bone Level®

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Type 2 = angled over corner•Recommended torque: 35 Ncm

Type 1

Type 2 Implant connection RC 4.1/4.8 RC 4.1/4.8 RC 4.1/4.8Gingiva height 2.5 mm 3.5 mm 5.5 mmArticle No. Type 1 CL 8110 CL 8111 CL 8112Article No. Type 2 CL 8210 CL 8211 CL 8212Abutment screw CL 65 CL 65 CL 65

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Type 2 = angled over corner•Recommended torque: 35 Ncm

Type 1

Type 2 Implant connection RC 4.1/4.8 RC 4.1/4.8 RC 4.1/4.8Gingiva height 3.0 mm 4.0 mm 5.5 mmArticle No. Type 1 CL 8310 CL 8311 CL 8312Article No. Type 2 CL 8410 CL 8411 CL 8412Abutment screw CL 65 CL 65 CL 65

Multi-unit prosthetic components•CL 8501 Multi-unit bridge screw

Torx T6•CL 8508 Multi-unit titanium base

incl. bridge screw•CL 8505 Multi-unit titanium cap

incl. bridge screw•CL 8506 Multi-unit gold cap,

castable incl. bridge screw•CL 8507 Multi-unit CoCr cap incl.

bridge screw•Recommended torque: 15 Ncm

Material Titanium grade 5 CF

Titanium grade 5 CF

Titanium grade 5 CF

"(AU 60%; Pd 20%; Pt 19%;

Ir 1%)"

CrCo alloy / CTE 14.1

Article No. CL 8501 CL 8508 CL 8505 CL 8506 CL 8507

Multi-unit modelling sleeve•Tecanat (PC)

Article No. 8510Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and

Multi-unit titanium cap.

Page 22: For multi-unit restorations - conventional or digital

22 » CL-SERIES « Straumann® Bone Level®

Multi-unit scanbody•Titanium grade 5 CF specially

coated•incl. bridge screw

Version straight angledArticle No. L 8500 L 8513Please note: The Scanbody is sterilisable for intra-oral scanning.

Multi-unit Laboratory implant•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8504 8514-17 8514-30

Multi-unit Laboratory implant CADCAM•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8509 8515-17 8515-30

Multi-unit accessories•CL 8502 Multi-unit cover cap•CL 8503 Multi-unit open tray

impression coping•M 11-11 Placement instrument

Multi-unit abutment•8515 T Placement instrument

laboratory implant CADCAM Article No. CL 8502 CL 8503 M 11-11 8515 T

Page 23: For multi-unit restorations - conventional or digital

23» Cn-SERIES « Straumann® Tissue Level®

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 35 Ncm

Implant connection RN 4.8Gingiva height 0.9 mmArticle No. CN 8010

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 35 Ncm

Implant connection WN 6.5Gingiva height 1.2 mmArticle No. CN 8020

Multi-unit prosthetic components•CN 8501 Multi-unit bridge screw

Torx T6•CN 8508 Multi-unit titanium base

incl. bridge screw•CN 8505 Multi-unit titanium cap

incl. bridge screw•CN 8506 Multi-unit gold cap,

castable incl. bridge screw•CN 8507 Multi-unit CoCr cap incl.

bridge screw•Recommended torque: 15 Ncm

Material Titanium grade 5 CF

Titanium grade 5 CF

Titanium grade 5 CF

"(AU 60%; Pd 20%; Pt 19%;

Ir 1%)"

CrCo alloy / CTE 14.1

Article No. CN 8501 CN 8508 CN 8505 CN 8506 CN 8507

Multi-unit modelling sleeve•Tecanat (PC)

Article No. 8510Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and

Multi-unit titanium cap.

Multi-unit scanbody•Titanium grade 5 CF specially

coated•incl. bridge screw

Version straightArticle No. CN 8500Please note: The Scanbody is sterilisable for intra-oral scanning.

Page 24: For multi-unit restorations - conventional or digital

24 » CN-SERIES « Straumann® Tissue Level®

Multi-unit Laboratory implant•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8504 8514-17 8514-30

Multi-unit Laboratory implant CADCAM•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8509 8515-17 8515-30

Multi-unit accessories•M 11-11 Placement instrument

Multi-unit abutment•CN 8502 Multi-unit cover cap•CN 8503 Multi-unit open tray

impression coping•8515 T Placement instrument

laboratory implant CADCAM Article No. M 11-11 CN 8502 CN 8503 8515 T

Page 25: For multi-unit restorations - conventional or digital

25» CR-SERIES « Zimmer Dental® - Tapered Screw-Vent®

MIS® - SEVEN® Internal HexBioHorizons® - Tapered Internal/Internal Plus/Tissue Level

Comparison chart Zimmer Dental® MIS® BioHorizons®

BioHorizons® Platform 3,0 mm

Platform 3,5 mm

Platform 4,5 mm

Platform 5,7 mm

implant Ø 3.00 3.80 4.60 5.80

Laboratory implant Ø 3.00 3.50 4.50 5.70

Article Number TP3IA SYIA SGIA SBIA

Implant connection

Medentika R-series laboratory implant 3.0 3.50 4.50 5.70

Article Number CR 53 CR 50 CR 51 CR 52

Zimmer Dental® Platform 3,5 mm

Platform 4,5 mm

Platform 5,7 mm

implant Ø 3.70 4.10 4.70 6.00

Laboratory implant Ø 3.50 3.50 4.50 5.70

Article Number IA3 IA3 IA4 IA5

Implant connection

Medentika R-series laboratory implant 3.5 3.5 4.5 5.7

Article Number CR 50 CR 50 CR 51 CR 52

MIS® Narrow-Platform

Standard-Platform

Wide-Platform

implant Ø 3.30 3.30 3.75 4.20 5.00 6.00

Laboratory implant Ø 3.30 4.20 4.20 4.20 4.50 4.50

Article Number MN-RSM10 MD-RSM10 MD-RSM10 MD-RSM10 MW-RSM10 MW-RSM10

Implant connection

Medentika R-series laboratory implant XX 3.50 3.50 3.50 4.50 4.50

Article Number XX CR 50 CR 50 CR 50 CR 51 CR 51

Page 26: For multi-unit restorations - conventional or digital

26 » CR-SERIES «Zimmer Dental® - Tapered Screw-Vent®

MIS® - SEVEN® Internal HexBioHorizons® - Tapered Internal/Internal Plus/Tissue Level

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 30 Ncm

Implant connection D 3.5 D 3.5 D 3.5Gingiva height 1.0 mm 3.0 mm 5.0 mmArticle No. CR 8000 CR 8001 CR 8002

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 30 Ncm

Implant connection D 4.5 D 4.5 D 4.5Gingiva height 1.0 mm 3.0 mm 5.0 mmArticle No. CR 8010 CR 8011 CR 8012

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 30 Ncm

Type 1

Implant connection D 3.5 D 3.5 D 3.5Gingiva height 2.5 mm 3.5 mm 5.5 mmArticle No. CR 8100 CR 8101 CR 8102Abutment screw CR 64 CR 64 CR 64

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 30 Ncm

Type 1

Implant connection D 3.5 D 3.5 D 3.5Gingiva height 3.0 mm 4.0 mm 5.5 mmArticle No. CR 8300 CR 8301 CR 8302Abutment screw CR 64 CR 64 CR 64

Page 27: For multi-unit restorations - conventional or digital

27» CR-SERIES «Zimmer Dental® - Tapered Screw-Vent®

MIS® - SEVEN® Internal HexBioHorizons® - Tapered Internal/Internal Plus/Tissue Level

Zimmer Dental® - Tapered Screw-Vent®

MIS® - SEVEN® Internal HexBioHorizons® - Tapered Internal/Internal Plus/Tissue Level

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 30 Ncm

Type 1

Implant connection D 4.5 D 4.5 D 4.5Gingiva height 2.5 mm 3.5 mm 5.5 mmArticle No. CR 8110 CR 8111 CR 8112Abutment screw CR 64 CR 64 CR 64

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 30 Ncm

Type 1

Implant connection D 4.5 D 4.5 D 4.5Gingiva height 3.0 mm 4.0 mm 5.5 mmArticle No. CR 8310 CR 8311 CR 8312Abutment screw CR 64 CR 64 CR 64

Multi-unit prosthetic components•CR 8501 Multi-unit bridge screw

Hex 1.26•CR 8508 Multi-unit titanium base

incl. bridge screw•CR 8505 Multi-unit titanium cap

incl. bridge screw•CR 8506 Multi-unit gold cap,

castable incl. bridge screw•CR 8507 Multi-unit CoCr cap incl.

bridge screw•Recommended torque: 15 Ncm

Material Titanium grade 5 CF

Titanium grade 5 CF

Titanium grade 5 CF

"(AU 60%; Pd 20%; Pt 19%;

Ir 1%)"

CrCo alloy / CTE 14.1

Article No. CR 8501 CR 8508 CR 8505 CR 8506 CR 8507

Multi-unit modelling sleeve•Tecanat (PC)

Article No. 8510Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and

Multi-unit titanium cap.

Multi-unit scanbody•Titanium grade 5 CF specially

coated•incl. bridge screw

Version straight angledArticle No. CR 8500 CR 8513Please note: The Scanbody is sterilisable for intra-oral scanning.

Page 28: For multi-unit restorations - conventional or digital

28 » CR-SERIES «Zimmer Dental® - Tapered Screw-Vent®

MIS® - SEVEN® Internal HexBioHorizons® - Tapered Internal/Internal Plus/Tissue Level

Multi-unit Laboratory implant•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8504 8514-17 8514-30

Multi-unit Laboratory implant CADCAM•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8509 8515-17 8515-30

Multi-unit accessories•M 11-11 Placement instrument

Multi-unit abutment•CR 8502 Multi-unit cover cap•CR 8503 Multi-unit open tray

impression coping•8515 T Placement instrument

laboratory implant CADCAM Article No. M 11-11 CR 8502 CR 8503 8515 T

Page 29: For multi-unit restorations - conventional or digital

Zimmer Dental® - Tapered Screw-Vent®

MIS® - SEVEN® Internal HexBioHorizons® - Tapered Internal/Internal Plus/Tissue Level

29» CV-SERIES « Dentsply® Implants ASTRA TECH OsseoSpeed® EV

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 25 Ncm

Implant connection D 3.6 D 3.6 D 3.6Gingiva height 1.5 mm 3.5 mm 5.5 mmArticle No. CV 8010 CV 8011 CV 8012

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 25 Ncm

Implant connection D 4.2 D 4.2 D 4.2Gingiva height 1.5 mm 3.5 mm 5.5 mmArticle No. CV 8020 CV 8021 CV 8022

Multi-unit abutment straight•Titanium grade 5 CF•Recommended torque: 25 Ncm

Implant connection D 4.8 D 4.8 D 4.8Gingiva height 1.5 mm 3.5 mm 5.5 mmArticle No. CV 8030 CV 8031 CV 8032

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 25 Ncm

Type 1

Implant connection D 3.6 D 3.6 D 3.6Gingiva height 2.5 mm 3.5 mm 5.5 mmArticle No. CV 8110 CV 8111 CV 8112Abutment screw CV 64 CV 64 CV 64

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 25 Ncm

Type 1

Implant connection D 3.6 D 3.6 D 3.6Gingiva height 3.0 mm 4.0 mm 5.5 mmArticle No. CV 8310 CV 8311 CV 8312Abutment screw CV 64 CV 64 CV 64

Page 30: For multi-unit restorations - conventional or digital

30 » CV-SERIES « Dentsply® Implants ASTRA TECH OsseoSpeed® EV

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 25 Ncm

Type 1

Implant connection D 4.2 D 4.2 D 4.2Gingiva height 2.5 mm 3.5 mm 5.5 mmArticle No. CV 8120 CV 8121 CV 8122Abutment screw CV 65 CV 65 CV 65

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 25 Ncm

Type 1

Implant connection D 4.2 D 4.2 D 4.2Gingiva height 3.0 mm 4.0 mm 5.5 mmArticle No. CV 8320 CV 8321 CV 8322Abutment screw CV 65 CV 65 CV 65

Multi-unit abutment angled 17°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 25 Ncm

Type 1

Implant connection D 4.8 D 4.8 D 4.8Gingiva height 2.5 mm 3.5 mm 5.5 mmArticle No. CV 8130 CV 8131 CV 8132Abutment screw CV 66 CV 66 CV 66

Multi-unit abutment angled 30°•Titanium grade 5 CF•incl. abutment screw•Type 1 = angled over flat•Recommended torque: 25 Ncm

Type 1

Implant connection D 4.8 D 4.8 D 4.8Gingiva height 3.0 mm 4.0 mm 5.5 mmArticle No. CV 8330 CV 8331 CV 8332Abutment screw CV 66 CV 66 CV 66

Page 31: For multi-unit restorations - conventional or digital

31» CV-SERIES « Dentsply® Implants ASTRA TECH OsseoSpeed® EV

Multi-unit prosthetic components•CV 8501 Multi-unit bridge screw Hex 1.26•CV 8508 Multi-unit titanium base incl. bridge screw•CV 8505 Multi-unit titanium cap incl. bridge screw•CV 8506 Multi-unit gold cap, castable incl. bridge screw•CV 8507 Multi-unit CoCr cap incl. bridge screw•Recommended torque: 15 Ncm

Material Titanium grade 5 CF

Titanium grade 5 CF

Titanium grade 5 CF

"(AU 60%; Pd 20%; Pt 19%;

Ir 1%)"

CrCo alloy / CTE 14.1

Article No. CV 8501 CV 8508 CV 8505 CV 8506 CV 8507

Multi-unit modelling sleeve•Tecanat (PC)

Article No. 8510Please note: The Multi-unit modelling sleeve can be used with the Multi-unit titanium base and Multi-unit titanium cap.

Multi-unit scanbody•Titanium grade 5 CF specially coated•incl. bridge screw

Version straight angledArticle No. CV 8500 CV 8513Please note: The Scanbody is sterilisable for intra-oral scanning.

Multi-unit Laboratoryimplant•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8504 8514-17 8514-30

Multi-unit Laboratory implant CADCAM•Titanium grade 5 CF

Version straight angled angledType 17° 30°Article No. 8509 8515-17 8515-30

Multi-unit accessories•CV 8502 Multi-unit cover cap•CV 8503 Multi-unit open tray impression coping •M 11-11 Placement instrument Multi-unit abutment•8515 T Placement instrument laboratory implant CADCAM Article No. CV 8502 CV 8503 M 11-11 8515 T

Page 32: For multi-unit restorations - conventional or digital

32

Abutment Direct Inc.102-7351 Victoria Park Avenue, Markham, ON Canada L3R 3A5

Phone: (905) 604-0465 Fax: (905) 604-0900 Toll Free: [email protected] www.abutmentdirect.com

Next day delivery on orders placed before 6pm EST

Free Shipping on orders over $500.00 (before taxes)

Office hours: Monday - Thursday 9am - 6pm EST Friday 9am - 5:30pm EST