Auto Configure Master Valves Sensors FloManager FloWatch Edit Configuration and Stations... Direct Satelitte Tasks Select One or More Sites... Site Name Out of Sync Satellite Changes Alarm Satellites Off Auto Contacts... Add Site... Synchronize Edit Site... Retrieve Logs... Site Name Description Time Zone Postal Code (UTC-8:00) Pacific Time (US and Canada) Site 01 OK Cancel Satellites Program... Dry Run... Manual Operations... Configure... Add... Auto Configure Master Valves Sensors FloManager FloWatch Edit Configuration and Stations... Direct Satelitte Tasks Client Satellite LXME Client Satellite Server Satellite 2 0 gal/min 1 1 Satellite Name: Type: Connection Type: Server: Network Address: Description: Dry Run Warning for Max Flow: Max. Satellite Irrigation SimulStations: Max. Satellite Non-Irrigation SimulStations: PIN-Codes: Weather Source: Configuration Stations OK Cancel Unprotected Detect Modules automatically and update IQ Upload Satelitte Configuration into IQ Upload Satelitte Programming into IQ Retrieve Learned Flow Data into IQ OK Cancel Modules Configuration Programs Learned Flow 1. Choose Satellite 2. Choose IQNet Type LXD Direct LXME Server Choose the IQNet Server for this Client: Server Satellite LXMEF LXM Client OK Cancel Auto Configure Master Valves Sensors FloManager FloWatch Edit Configuration and Stations... Direct Satelitte Tasks Satellite 001 LXME IP Connection 10.84.177.16 5005 0 gal/min 1 1 Satellite Name: Type: Connection Type: Phone Number / IP Address Port: Description: Dry Run Warning for Max Flow: Max. Satellite Irrigation SimulStations: Max. Satellite Non-Irrigation SimulStations: PIN-Codes: Weather Source: Configuration Stations OK Cancel Unprotected Satellites Program... Dry Run... Manual Operations... Configure... Add... 1. Choose Satellite 2. Choose IQNet Type LXD Direct LXME Server LXMEF LXM Client OK Cancel 1 IQNet Server/Client Communication • Connection Module (CM) PE-Cable and/or Radio Secondary Communication IQNet Server/Client Communication Overview Allows a single Server Satellite with IQ pri- mary communication connection (Cellu- lar, Ethernet, etc.) to be shared with up to 255 Client Satellites via Radio and/or Con- nection Module (CM) PE-Cable secondary communication. a. Utilizes lower cost IQNCCRS RS-232 Cartridges for Client Satellites. b. Reduces yearly reoccurring com- munication costs for systems using Cellular communication. c. Provides Normally Closed Master Valve or Pump Start sharing be- tween Server and Client Satellites. d. Provides Weather Sensor (not Flow Sensor) sharing between Server and Client Satellites. Rain+Birdt IQNCCRS RS-232 Network Communication Cartridge - IQNet Server/Client Installation & IQ-Cloud Configuration For Additional Information See IQ-NCC Cartridge Installation and Operations Guide for IQ3G- USA Cellular and IQNCCEN Ethernet Cartridge Installation and Configuration Instructions. Go to www.RainBird.com/ for training, presentations, product literature and information for IQ- Enterprise and IQ-Desktop. IQ-Cloud Support (800) 254-0692 I[email protected] www.RainBird.com/IQ Rain Bird Global Service Plan (GSP) (866) 477-9778 [email protected] 9 Go to www.rainbird.com/iq A New users: Select IQ-Cloud Sign-up. B Existing users: Select IQ-Cloud Login. 10 Select Add Site 13 Add Client Satellites A Choose ESP-LX Controller Type. B Select Client IQNet Type. 14 Configure Client Satellites A Select Edit Configuration and Stations. B Enter the unique IQNet Network Address (2 to 56) that you selected in the Setup Wizard for each Client Satellite. 15 Reverse Sync Data from each Satellite A Select Auto Configure. B Check All Options. 2018 Rain Bird Corporation tRegistered trademark of Rain Bird Corporation P/N: 690656-01 Rev. 6/18 D41261 3 Attach IQ Cables to Cartridges in Server and Client Satellites C Select the Server Satellite this Client is connected to. 12 Configure Server Satellite A Select Edit Configuration and Stations. B Select IP Connection Type, enter the IP Address and Port Number for IQ-Cloud to communicate to the Server Satellite. 11 Add Server Satellite A Choose ESP-LX Controller Type. B Select Server IQNet Type. 2 Install IQ-NCC Cartridges 4 Attach IQ Cables to Radio/CM Module Attach Supplied Y-Cable to Radios or Straight-Cable to CM Modules 8 Check IQNet Satellite Communication Status from the Client Satellites 7 Test Satellite Communication from the Server Satellite B The Setup - Satellite Type screen is displayed. Use + or - to select Direct' press Next. NOTE: The IQ Port status will allways show Disabled for Client Satellites. g Turn the controller dial to ETM/IQ Settings 5 Setup Wizard for Server Satellite g Turn the controller dial to ETM/IQ Settings 6 Setup Wizard for Client Satellite g Turn the controller dial to ETM/IQ Settings B The Setup - Satellite Type screen is displayed. Use + or - to select Client; press Next. C The Setup – Satellite Address screen is displayed. Use + or - to select a unique address from 002-256 for this satellite (press and HOLD but- tons to accelerate settings); press Next. D The Setup – Satellite Radio Port screen is displayed. Use + or - to select a radio port op- tion (No Radio Installed, Radio Installed); press Next. E The Setup – Satellite CM Port screen is displayed. Use + or - to select a CM Port option (No Module, Module Installed); press Next. F The Setup – CM Port Termination screen is dis- played. Use + or - to select a CM Port Termination option (On or Off ). NOTE: CM Port termination is only required if this satellite is at the end of an IQNet PE Communication Cable path. If you are not sure, consult with the system designer. A The IQ Settings main menu is displayed. Use the UP or DOWN arrows to select Setup Wizard; press Next. B The Setup - Satellite Type screen is displayed. Use + or - to select Server; press Next. C The Setup – Satellite Address screen is displayed. Server Satellites always have an ad- dress of 001; press Next. D The Setup – Satellite IQ Port screen is displayed; press Next. E The Setup – Satellite Radio Port screen is displayed. Use + or - to select a radio port op- tion (No Radio Installed, Radio Installed); press Next. F The Setup – Satellite CM Port screen is displayed. Use + or - to select a CM Port option (No Module Installed, Module Installed); press Next. g Turn the controller dial to ETM/IQ Settings A The IQ Settings main menu is dis- played. Use the UP or DOWN ar- rows to select Status; press Next. B The Satellite Status screen is displayed. Current status of IQ, Radio, and CM ports are shown. Press Signal to display 3G signal strength. C The Signal Strength is displayed. The signal strength between the satellite and the 3G Cellular net- work is indicated on a scale of 1-10. D The Satellite Status screen is dis- played. Current status of IQ, Radio, and CM ports are shown. Press Ping to check the communication status with selected Clients. E The IQNet Ping screen is displayed. Use the + and - buttons to select any Client address. Press Ping to check the communication status. The LCD will display Response-Yes if the ping is successful, or No for an unsuccessful ping. A The IQ Settings main menu is dis- played. Use the UP or DOWN arrows to select Setup Wizard; press Next. A The IQ Settings main menu is dis- played. Use the UP or DOWN arrows to select Status; press Next. Install IQ3G-USA Cellular or IQNCCEN Ethernet Cartridge in Server Satellite Install IQNCCRS RS-232 Cartridges in the Client Satellites NOTE: Refer to IQ3G-USA Cellular and IQNCCEN Ethernet Cartridge Installation Posters for full Installation instructions. NOTE: Use Y-Cable for satellites that have both a CM Module and Radio. What’s New IQ-Cloud Sign Up IQ-Cloud Login EN IQ-Cloud Support (800) 254-0692 | [email protected] IQ-Cloud Login Login Configure this computer Rain Bird IQ Central Control System TM User Name Password I forgot my password Log On Cancel What’s New Show Quick Start C Select Configure this computer for first time IQ-Cloud connection on a new computer. D Enter User Name & Password to Logon to IQ-Cloud. 3G Cellular Antenna Backplane Connect DB9 Cable end to Radio port Connect 2-pin cable end to CM Module ESP-LX Controller Server Satellite IQ3G-USA or IQNCCEN Cartridge Supplied IQ-Y and Straight Cables Connect Cartridges to CM's and Radios IQFSCMLXME Flow Smart Connection Modules for ESP-LXME Controllers and IQCMLXD Connection Modules for LXD Controllers To Internet and IQ-Cloud To Additional Connection Module Client Satellites To Additional Radio or Connection Module Client Satellites IQNCCRS Cartridge ESP-LX Controller ESP-LX Controller IQNCCRS Cartridge 19-Gauge PE Cable, Twisted Pair, Shielded, Gel Filled Communication Cable (Max 18K feet) IQSSRADIO or RB- SS-TN9B Radios (separate antenna and Radio Site Survey required) Attach IQ-Y Cable to Radio IQ NCC Cartridges Attach Straight-Cable for Connection Modules (CM) Client Satellite