Top Banner
FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.
17

FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

Dec 14, 2015

Download

Documents

Darius Hearst
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

FocusPRO®

Training Module

Click For Next Slide

To advance this module, click when this icon appears on the slide.

Page 2: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

2 HONEYWELL - CONFIDENTIAL File Number

What you will learn

• Key attributes of the FocusPRO product family

• Features and benefits of the FocusPRO product line

• How FocusPRO can be applied to different system types

• How to set up the thermostat

Click For Next Slide

Page 3: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

3 HONEYWELL - CONFIDENTIAL File Number

FocusPRO Series Thermostats

The FocusPRO® 5000 Single Stage Non-Programmable Thermostat was introduced in September 2004.

This was followed shortly by the introduction of the FocusPRO ® 5000 Multistage Non-Programmable and FocusPRO® 6000 Programmable Thermostat introduced in April 2005.

Click For Next Slide

Page 4: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

4 HONEYWELL - CONFIDENTIAL File Number

Key FocusPRO® 6000 Key Features • Selectable 5-2 or 5-1-1 Programming• Precise Comfort Control +/- 1º F• Permanent and temporary holds• Dual Powered (Battery/Hardwired)• Large Backlit Displays - Standard and Large• Adaptive Intelligent Recovery™• Permanent Memory Retention• Compressor protection / Random start delay• Displays Room Temperature and Set point Simultaneously• Universal Applications• Auto Changeover • Temperature Range Stops • Onboard Quick Guide Instructions• Easy Battery Access-swing out battery door• 5-Year Limited Warranty

Click For Next Slide

Page 5: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

5 HONEYWELL - CONFIDENTIAL File Number

Key FocusPRO® 5000 Features • Precise Comfort Control +/- 1º F• Dual Powered (Battery/Hardwired) • Large Backlit Displays - Standard and Large• Permanent Memory Retention• Compressor protection / Random start delay• Displays Room Temperature and Set point

Simultaneously• Universal Applications • Auto Changeover • Temperature Range Stops • Easy Battery Access-swing out battery door• 5-Year Limited Warranty

Click For Next Slide

Page 6: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

6 HONEYWELL - CONFIDENTIAL File Number

New! FocusPRO 5000 Comfort / Economy Setting

• Systems with heat pumps can be set to operate in one of two ways with the FocusPRO 5000:

- Comfort Setting: The thermostat will prioritize comfort over economy depending on heat pump performance, load conditions and whether the equipment is calling for heat. Raising the temperature just a few degrees will often activate auxiliary heat.

- Economy Setting: The thermostat will attempt to reach the temperature setting without activating auxiliary heat. The thermostat waits a preset time before allowing auxiliary heat to be activated depending on the compressor stage performance, and on how many degrees the temperature setpoint is changed.

Click For Next Slide

Page 7: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

7 HONEYWELL - CONFIDENTIAL File Number

FocusPRO Applications

• Universal Application-Up to 3 Heat/2 Cool Heat Pump

1 Heat/1 Cool Heat Pump (no auxiliary)2 Heat/1 Cool Heat Pump2 Heat/2 Cool Heat Pump (no auxiliary)3 Heat/2 Cool Heat Pump

-Up to 2 Heat/2 Cool Conventional1 Heat/1 Cool Conventional2 Heat/2 Cool Conventional2 Heat/1 Cool Conventional1 Heat/2 Cool Conventional

Click For Next Slide

Page 8: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

8 HONEYWELL - CONFIDENTIAL File Number

FocusPRO® Installer Setup

To begin, press and HOLD the “Up” Arrow and “Fan” buttons

until the display changes.

Click For Next Slide

Page 9: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

9 HONEYWELL - CONFIDENTIAL File Number

FocusPRO® Installer System Test

To begin, press and HOLD the “Up” and “Down” Arrow until

the display changes.

Click For Next Slide

Page 10: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

10 HONEYWELL - CONFIDENTIAL File Number

FocusPRO® Advantage

• Readability• Quality• Comfort• Simplicity• Universal Application

Click For Next Slide

Page 11: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

FocusPRO®

Knowledge Test

Click For Next Slide

Page 12: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

12 HONEYWELL - CONFIDENTIAL File Number

• Now that you completed this training module, take the short quiz to test your knowledge.

FocusPRO® Knowledge Test

Click For Next Slide

Page 13: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

13 HONEYWELL - CONFIDENTIAL File Number

Test

1. Why does the FocusPRO® have two different display size options?

A. To confuse the customer

B. Halfway through the project, Marketing changed their minds about size, so engineering gave them both

C. To meet the needs of different customer segments

D. To confuse the competition

2. The FocusPRO 5000 is a _____________ thermostat and the FocusPRO 6000 is a ______________ thermostat.

a. Non-Programmable and Programmableb. Programmable and Non-Programmablec. Both are Programmabled. Both are Non-Programmable

Page 14: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

14 HONEYWELL - CONFIDENTIAL File Number

Test

3. When would a homeowner want the “Economy Setting” feature on the FocusPRO 5000 thermostat?

A.Prevent children from using the thermostatB.Limits the use of auxiliary heat in mild conditionsC.Extends the cycle rate of the compressor stageD.Increases the use of the auxiliary heat to improve homeowner comfort

4. To enter the Installer set up on the FocusPRO thermostat, press and hold the _______ and _______ buttons until the display changes.

a. System and Up Arrowb. System and Down Arrowc. Fan and Systemd. Fan and Up Arrowe. Fan and Down Arrow

Page 15: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

15 HONEYWELL - CONFIDENTIAL File Number

Test

5. The FocusPRO 6000 and 5000 thermostats feature an easy access battery door for quick battery replacement. T F

6. The FocusPRO 5000 can be selectable 5-2 or 5-1-1 programming.T F

7. The FocusPRO 6000 and 5000 display room and set point temperature simultaneously. T F

8. What is one of the top advantages of the FocusPRO 6000 and 5000 thermostats?a. Programmableb. Lowest Pricec. Simplicityd. Non-Programmable

Page 16: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

16 HONEYWELL - CONFIDENTIAL File Number

Test

9. The FocusPRO 6000 and 5000 both offer a 5-year warranty.

T F

10. The FocusPRO 6000 offers Universal Application up to ____ for Heat Pump and _____ for Conventional.

a. 2H/2C, 3H/2C

b. 2H/2C, 2H2/C

c. 3H/2C, 3H/2C

d. 3H/2C, 2H/2C

Page 17: FocusPRO ® Training Module Click For Next Slide To advance this module, click when this icon appears on the slide.

17 HONEYWELL - CONFIDENTIAL File Number

Answer Key

1. C2. A3. B4. D5. T6. F7. T8. C9. T10. D