Top Banner
fMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength voxel size RF coil Things that determine noise contribution Bandwidth (thermal noise) Brains (physiological noise) • Averaging antwrp.gsfc.nasa.gov/apod/ap041008.html 1 light year = 5,913,000,000,000 miles?
19

FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Dec 21, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

fMRI: Biological Basis and Experiment DesignLecture 12: Signal-to-Noise Ratio

• Things that determine signal strength– voxel size– RF coil

• Things that determine noise contribution– Bandwidth (thermal noise)– Brains (physiological noise)

• Averaging

antwrp.gsfc.nasa.gov/apod/ap041008.html

1 light year = 5,913,000,000,000 miles?

Page 2: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Broad definitions

• Thermal noise– Assumed white

– Fluctuations in RF path (coupling to sample, amplifiers ...)

• Physiological noise– Probably colored

– Vasoreactivity

– Motion

– Respiration

– Cardiac

– ...

– Uncontrolled cognitive processes

Page 3: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

SNR, definition 1

S

SSNR

SNRregular = 317SNRsense = 251

Page 4: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Spatial dependence of SNR with parallel imaging

Page 5: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

SNR definition 2

N

SSSSNR

measNN 86.025.1 ,

Page 6: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Rician distribution: effect of magnitude reconstruction on noise close to zero

Page 7: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

SNR definition 2

N

SSSSNR

measNN 86.025.1 ,

= 48.2= 58.6

= 56.7= 61.0

????? S = 3226S = 3012

Page 8: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

SNR maps, 2 definitions

Definition 1: mean through time divided by standard deviation through time

Definition 2: static signal intensity divided by background noise

Page 9: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

SNR maps in water phantoms

New category of noise: inanimate processes?

Siemen’s implementation of SENSERegular EPI

Page 10: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

SNR – dependence on coil properties

(These are just static images, not SNR maps.)

Body coil transmit,body coil receive

Body coil transmit,8-channel coil receive

Page 11: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

SNR – dependence on bandwidth

dwellTime = 5s dwellTime = 10s

Page 12: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Surface coils vs. volume coils:

Page 13: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Nova “visual coil”

Nova birdcage head coil

Page 14: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.
Page 15: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Pulse sequence diagram: Spoiling in FLASH/GRASS/RAGE ...

Nrep = 256

256 points

RF

GSS

GPE

GRO

DAC

Flip angle = 7 deg. TR = 10ms

TE ~ 5ms

Goal: obliterate any remaining transverse magnetization before next excitation.

Page 16: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Image: Navg = 4

Page 17: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Averaging beats down noise

Page 18: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Physiological vs. thermal noise

Page 19: FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.

Physiological vs. thermal noise