Top Banner
FLUORAT- 02 - PANORAMA FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER SPECTROFLUOROMETER
19

FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

Dec 16, 2015

Download

Documents

Alyson Butler
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

FLUORAT- 02 - FLUORAT- 02 - PANORAMAPANORAMA

SPECTROFLUOROMETESPECTROFLUOROMETERR

Page 2: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

FLUORAT- 02 - PANORAMA FLUORAT- 02 - PANORAMA SPECTROFLUOROMETERSPECTROFLUOROMETER

CERTIFICATIONCERTIFICATION

SINCE 1996SINCE 1996

Page 3: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

ANALITICAL METHODSANALITICAL METHODS

Methods

Luminescent analysis • liquid sample; • glass;• paper; • powder; • fabric

Photometric analysis • liquid sample;

• small (10 x 10 mm) or large

(60 x 60 mm) size glass

Time-resolved analysis of luminescent kinetics

• all kinds of above listed samples

Page 4: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

ADVANTAGEADVANTAGESS

Xe-flash lamp (1 μs on half-width)– ultra high intensity in hard UV-range (210 nm)– time-resolved luminescent kinetics

measurements (step = 50 ns)– very low power consumption (40 W)

Optical scheme with a good correlation between fluo-channel and reference and photometric channels

Broad set of FFOS-attachments

Uniform design for 2 main applications– scientific spectrofluorimeter– HPLC-detector

Page 5: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

MAIN APPLICATIONSMAIN APPLICATIONS

Scientific and Medical Researches

Environmental Monitoring

Determination of water oil pollutersConcentration of oil in water

measurementBioproduction study of nature water

reservoirs by chlorophyll level

Optimization of determination conditions for analytical techniques

Studies of luminescent substances and label methods

Technological Quality ControlGroundwater survey by fluorescent

label methodPurity test for silicon plates after

cuttingQuality of luminophores

Forensic investigations

Fires reasons determination

Identification of luminescent marks on securities

Page 6: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

TECHNTECHNIQUEIQUESS

Object Samples

Natural, potable and waste water

Nitrite, oil, phenols, fluoride, formaldehyde, benz[a]pyrene, surfactants, Al, Be, Se, Cu, Fe, B, Zn, Pb, Sn, As, Mo, V

Air in production areas and atmospheric air in residential quarters

Phenols, formaldehyde, cadmium, copper, zinc

Industrial emission Phenols, lead, formaldehyde, benz[a]pyrene

Foodstuff Vitamines B1, B2, С, zinc, tin

Soil Oil, boron, zinc

Petrol Lead

Page 7: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

SOFTWARESOFTWARE

Functional schemeFunctional scheme

Page 8: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

SOFTWARESOFTWARE

Functional schemeFunctional scheme

Page 9: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

SOFTWARESOFTWARE

Functional schemeFunctional scheme

Page 10: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

SOFTWARESOFTWARE

ChromatographyChromatography

1 Fluorene

2 Phenantrene

3 Antracene

4 Fluorantene

5 Pyrene

6 Chrysene

7 Benz[b]fluorantene

8 Benz[k]fluorantene

Separation of PAHs in a

snow sample

Page 11: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

SOFTWARESOFTWARE

Spectral processingSpectral processing

Page 12: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

SOFTWARESOFTWARE

2D-Scanning2D-Scanning

Page 13: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

Kinetic measurementKinetic measurement

SOFTWARESOFTWARE

Page 14: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

ATTACHMENTSATTACHMENTS

FLUORAT-02-Panorama is used as a detector for gradient HPLC-system

HPLC-4 with 2 syringe pumps Python

Page 15: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

ATTACHMENTSATTACHMENTS

“Hobby”

“Microscan”

Photometric measurement outside the cell-compartment

Luminescent measurement outside the cell-compartment

“Frog”

Automated measurement

on standard plates

Page 16: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

ATTACHMENTSATTACHMENTS

Investigation of the samples under

liquid nitrogen temperature:

“Cryo-1” – studying the narrow band

Schpolsky spectra of PAHs

(benz[a]pyrene)“Cryo-2” – determination of the toxic metals,

e.g. Pb, Bi, Sn and others

Page 17: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

SPECIFICATIONSSPECIFICATIONS

Spectral Range 210 – 690 nm (210 – 840)

Slit width 6 – 8 nm (12 – 15 for HPLC-detector)

Wavelength accuracy ± 1 nm

Pulse repetition rate 25 Hz

S/N ratio for Raman scattering of H2O

150:1 (for 6 – 8 nm slit)

300:1 (for 12 – 15 nm slit)

Power requirements 110 – 240V, 40VA

Dimensions 400 x 350 x 160 mm

Weight 17 kg

Page 18: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

CONCLUSIONCONCLUSION

LUMEX spectrofluorometer Panorama has a good chance in competition with others instruments

But we are standing now in front of a very interesting and not so easy job –

Creating a new family of spectrofluorometric analyzers:

Detector for HPLC

Scientific spectrofluorimeter

Page 19: FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER FLUORAT- 02 - PANORAMA SPECTROFLUOROMETER CERTIFICATION SINCE 1996.

CONTACTSCONTACTS

LUMEX LTD.LUMEX LTD.

19, Moskovskiy pr., St. Petersburg, 190005 RussiaPhone: +7 (812) 718-5390, +7 (812) 718-5391Fax: +7 (812) 316-6538E-mail: [email protected], [email protected]; http://www.lumex.ru

LUMEX INTERNATIONALLUMEX INTERNATIONAL

4736 Lee Hwy, suite 203, Arlington VA 22207, USAPhone/Fax: +1 (703) 243-7103;E-mail: [email protected]; http://www.lumexint.com

OhioLumex Co.OhioLumex Co.

9263, Ravenna Rd., Unit A3 Twinsburg, OH 44087 USAPhone: +1 (888) 876-2611; +1 (330) 405-0837Fax: +1 (330) 405-0847E-mail: [email protected], [email protected]; http://www.ohiolumex.com