Page 1: Flow  Cytometry  at  Boston  University  Medical  Campus

Flow Cytometry at

Boston University Medical Campus

Introduction to some methods that we offer

Yan Deng (X4-5225), [email protected]

Gerald Denis (X4-1371), [email protected]

Page 2: Flow  Cytometry  at  Boston  University  Medical  Campus

Flow cytometry simultaneously measures and analyzes multiple physical characteristics of single particles, usually cells, as they move in a fluid stream through a beam of light.

Any suspended particle between 0.2 and 50μM issuitable.

Larger particles, solid tissue or clumps of cells must bedisaggregated to be analyzed.

Examples: lymphocytes, protozoa, micron beads, chromosomes

Definitions

Page 3: Flow  Cytometry  at  Boston  University  Medical  Campus

The particles in the fluid stream scatter incident light,which reveals internal properties, size and granularity.

The particles also fluoresce; they emit laser light at the interrogation point; this light is picked up by detectors arrayed at a different angle to detectors of scattered light.

Definitions

Page 4: Flow  Cytometry  at  Boston  University  Medical  Campus

fluidics

optics

electro

nics

Page 5: Flow  Cytometry  at  Boston  University  Medical  Campus

Fluidics

sample

flow cell

laser

waste

~2 x 105 to 1 x 107 cells/ml

sheath fluid

Page 6: Flow  Cytometry  at  Boston  University  Medical  Campus

Electronics

event FSC(size)

SSC(granularity)

FL1(green)

FL2(yellow)

FL3(red)

FL4etc

1 500 300 638 840 20 -

2 200 100 245 85 50 -

3 600 800 300 700 30 -

digitize

Page 7: Flow  Cytometry  at  Boston  University  Medical  Campus

FluidicsPurpose of the fluidics system:

1. Transport particles in a fluid stream to the laser beam to be interrogated

2. Position the sample core in the center of the laser beam

sheath fluid

samplefluid

‘hydrodynamic focusing’

single file particles

● low flow rate

● narrow sample core

● high resolution

● high flow rate

● wide sample core

● low resolution

Page 8: Flow  Cytometry  at  Boston  University  Medical  Campus

Fluidics

Concerns

1. Shear rates for cells: check after you complete a run to ensure that the cells are intact.

2. Larger tips are needed for cell sorting.

Page 9: Flow  Cytometry  at  Boston  University  Medical  Campus

Optics

Excitation is accomplished by lasers that emit light at specified wavelengths. The atomic properties of the excitation media define this wavelength for a particular laser.

The laser beam is focused on the sample core; lasers must be fixed in place.

This is the most common and versatile wavelength for excitation of fluorochromes.

Argon blue lasers emit light at 488 nm.

Page 10: Flow  Cytometry  at  Boston  University  Medical  Campus

Fluorescein (FITC)

Hoechst 33258 Texas Red

Propidium iodide (PI)

Laser light must overlap with excitation wavelength

Page 11: Flow  Cytometry  at  Boston  University  Medical  Campus

Optics

Filters resolve overlapping wavelengths of emitted light

Longpass filter: transmits light of longer than or equal toa specific wavelength

Shortpass filter: transmits light of shorter than or equal toa specific wavelength

Bandpass filter: transmits light only within a narrow rangeof wavelengths

Page 12: Flow  Cytometry  at  Boston  University  Medical  Campus
Page 13: Flow  Cytometry  at  Boston  University  Medical  Campus
Page 14: Flow  Cytometry  at  Boston  University  Medical  Campus

Excitation ofTexas Red is notoptimal with 488 nmlaser

Page 15: Flow  Cytometry  at  Boston  University  Medical  Campus

http://probes.invitrogen.com/resources/spectraviewer/

http://www.bdbiosciences.com/spectra/

For more information

Page 16: Flow  Cytometry  at  Boston  University  Medical  Campus

Electronics

The electronic system: 1. quantifies the voltage pulse2. converts analog signals to digital values3. performs compensation4. transfers data to the computer for analysis.

Page 17: Flow  Cytometry  at  Boston  University  Medical  Campus

Adjusting the voltageof the PMT helps tooptimize captureof desired populations

Electronics – Photomultiplier Tubes (PMTs)

Page 18: Flow  Cytometry  at  Boston  University  Medical  Campus

Electronics - Amplifiers

Amplifiers are of two types: linear or logarithmic

Linear amplification is typically used with scatter.

Logarithmic amplification is typically used with fluorescence.

DNA content (Linear detection)

DNA content (Log detection)

Page 19: Flow  Cytometry  at  Boston  University  Medical  Campus

Electronics

Threshold is the minimum pulse height above whicha signal will be processed electronically.

Page 20: Flow  Cytometry  at  Boston  University  Medical  Campus

Electronics

When a threshold value is defined, only signals with intensities greater than or equal to the value are recorded.

Adjustment of blood immunophenotype to exclude debris

before after

Page 21: Flow  Cytometry  at  Boston  University  Medical  Campus

Fluorescence

Page 22: Flow  Cytometry  at  Boston  University  Medical  Campus

FluorescenceFluorescence intensity is proportional to the number of binding sitesof the fluorescent compound, or “fluorochrome”.

Remember, when labeling live cells, to keep the experiment at 40C, becausereceptors are internalized and recycled, leaving their fluorochromes behind.

Page 23: Flow  Cytometry  at  Boston  University  Medical  Campus

Immunophenotyping

negative stain positive stain

Page 24: Flow  Cytometry  at  Boston  University  Medical  Campus

Cluster of Differentiation antibody specificity

CD3 Pan-T lymphocytes CD4 T helper/Inducer CD5 T cells, subset B cells CD11b Monocytes, granulocytes, NK/T cells CD19 B cellsCD20 B cells CD25 Il-2R, Tac IL-2 receptor, Activated T cells,

B cells, NK cells, monocytes CD34 Progenitor cells CD69 Early activation antigen on T, B and NK cells

Page 25: Flow  Cytometry  at  Boston  University  Medical  Campus

Immunophenotyping

Two-color fluorescence of lymphocytes

48%

44%

7%

1%

CD19-FITC

CD

3-P

E

Note the experiment-specific definition of the “negative” population

Page 26: Flow  Cytometry  at  Boston  University  Medical  Campus

Fluorescence

Multicolor analysis

Spectral overlap

Page 27: Flow  Cytometry  at  Boston  University  Medical  Campus

Compensation

To correct for emission spillover of FITC signal (normally detected in the FL1 channel) into the FL2 channel (which detects PE), it is necessary to use filters or electronic compensation or both.

Uncompensated Optimal

Page 28: Flow  Cytometry  at  Boston  University  Medical  Campus

Compensation

Before After

Multicolor immunophenotyping

Page 29: Flow  Cytometry  at  Boston  University  Medical  Campus

Data presentation formats

Page 30: Flow  Cytometry  at  Boston  University  Medical  Campus

Gates

Page 31: Flow  Cytometry  at  Boston  University  Medical  Campus

Gates

Page 32: Flow  Cytometry  at  Boston  University  Medical  Campus

The uses of gates for cell sorting

Page 33: Flow  Cytometry  at  Boston  University  Medical  Campus

Some applications

Multiparameter sorting

Cell cycle kinetics

Page 34: Flow  Cytometry  at  Boston  University  Medical  Campus

Some applications

DNA content for cell cycle / apoptosis

Immune system activation