Top Banner
Failure of Flexible PVC Hose in Underground Applications Duane Priddy, Ph.D. President/Plastic Failure Labs Plastics in Underground Pipes – Houston DP 11/1/11 1 Presented at “Plastics in Underground Pipes 2011” Houston, TX / November 1 & 2, 2011
16

Flexible pvc hose for underground applications

Jun 26, 2015

Download

Technology

Root cause of failure of flexible PVC hose used in swimming pools
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Flexible pvc hose for underground applications

Failure of Flexible PVC Hose in Underground Applications

Duane Priddy, Ph.D.

President/Plastic Failure Labs

Plastics in Underground Pipes – Houston DP 11/1/11 1

Presented at “Plastics in Underground Pipes 2011” Houston, TX / November 1 & 2, 2011

Page 2: Flexible pvc hose for underground applications

Benefits of PVC Hose

• Semi-flexible PVC hose combines the attributes of rigid PVC (high modulus) with flexible PVC (high flexibility) to yield a product that has the benefits of PVC pipe (easy to install using standard glued PVC fittings) yet it is semi-flexible allowing it to be installed with flexing around underground obstructions

2 Plastics in Underground Pipes – Houston DP 11/1/11

Page 3: Flexible pvc hose for underground applications

Manufacturing Process

• The hose is manufactured using a co-extrusion process where the rigid PVC formulation is extruded into a strand along side of the flexible PVC formulation which is extruded into a narrow sheet. As the strand and the sheet co-extrude from the die, they are wound around a mandrel to form the hose. The rigid PVC strand ends up embedded in the wall of the hose as a helical coil.

Plastics in Underground Pipes – Houston DP 11/1/11 3

Page 4: Flexible pvc hose for underground applications

Plastics in Underground Pipes – Houston DP 11/1/11 4

Page 5: Flexible pvc hose for underground applications

Example Failures: Swimming Pools

These failure occurred after 1 – 2 years of service

Plastics in Underground Pipes – Houston DP 11/1/11 5

Page 6: Flexible pvc hose for underground applications

Exterior Cracking is Most Common but also may Occur on Either the Interior Wall

Plastics in Underground Pipes – Houston DP 11/1/11 6

Page 7: Flexible pvc hose for underground applications

Microscope Views of Cracks

Close-up view of failed region in outside hose wall

View of fractures surface shows repeating diagonal void pattern in flexible PVC portion

Plastics in Underground Pipes – Houston DP 11/1/11 7

Page 8: Flexible pvc hose for underground applications

Fracture surface analysis

Closer view of the voids

Plastics in Underground Pipes – Houston DP 11/1/11 8

Page 9: Flexible pvc hose for underground applications

Views of Fracture Surface

Plastics in Underground Pipes – Houston DP 11/1/11 9

Page 10: Flexible pvc hose for underground applications

SEM Analysis of Fracture Surface

Plastics in Underground Pipes – Houston DP 11/1/11 10

Page 11: Flexible pvc hose for underground applications

SEM of Fracture Surface

Plastics in Underground Pipes – Houston DP 11/1/11 11

Page 12: Flexible pvc hose for underground applications

SEM Analysis of Fracture Surface

Plastics in Underground Pipes – Houston DP 11/1/11 12

Page 13: Flexible pvc hose for underground applications

FTIR Spectra of Flexible & Rigid Components in Failed Samples

Flexible

Rigid

DOP plasticizer

Plastics in Underground Pipes – Houston DP 11/1/11 13

Page 14: Flexible pvc hose for underground applications

Conclusions

• Some pipe samples contain voids in the fracture surface and fracture propagation follows the voids = manufacturing defect

• Most fractures show evidence of ESC failure of the rigid strands

• Flex hoses that use flexible PVC containing a migrating plasticizer are inherently defective because the plasticizer migrates into the rigid PVC strands causing them to stress-crack.

Plastics in Underground Pipes – Houston DP 11/1/11 14

Page 15: Flexible pvc hose for underground applications

Concluding Remarks

• Flex hose manufactures should use only flexible PVC made using non-migrating plasticizer.

• IAPMO needs to include a requirement in the PVC flex hose standard requiring only the use of non-migrating plasticizers.

Plastics in Underground Pipes – Houston DP 11/1/11 15

Page 16: Flexible pvc hose for underground applications

Possible Technical Solutions

• Use a rigid plastic component that is compatible with flexible PVC; e.g., PP

• Place a barrier layer between the rigid and flexible components to stop the DOP migration

• Develop a low cost non-migrating plasticizer

Plastics in Underground Pipes – Houston DP 11/1/11 16