While FlashShield CSST shares many of the same fitting assembly and installation guidelines as our standard CSST, there are a few important differences. This bulletin is intended as a quick summary of those differences, and is not intended to replace our official installation guide. FlashShield CSST Fittings and Installation Guide For more information go to www.gastite.com/flashshield. Or email us at fl[email protected]. Gastite • 1116 Vaughn Parkway • Portland, TN 37148 • 1-800-662-0208 Metal mesh layer dissipates electricity New fittings provide continuity with metal mesh NO additional manufacturer bonding required Quick and easy installation With no spacing requirements, FlashShield CSST is easy to install. Just follow the five simple steps outlined above. No additional bonding required FlashShield features the same level of installation convenience as our conventional CSST, with one key difference: there are no additional bonding requirements outside those mandated by national and local codes. New fitting design FlashShield CSST boasts a new fitting design that provides perfect continuity with the new layer of metal mesh. Patent-Pending Penetrating Feature creates Electrical Continuity between fitting and metal mesh Self-guiding assembly to ensure perfect flare Tool-less design, no special tools required All components fully re-usable Cut to length Strip jacket Install nut and bushings Position bushings Wrench fitting
2
Embed
FlashShield CSST Fittings and Installation Guideigate.northernplumbing.com/partsbreakdowns/gastite/fsfittings.pdfFlashShield CSST Fittings and Installation Guide To order, call your
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
While FlashShield CSST shares many of the same fitting assembly and installation guidelines as our standard CSST, there are a few important differences. This bulletin is intended as a quick summary of those differences, and is not intended to replace our official installation guide.
FlashShield CSST Fittings and Installation Guide
For more information go to www.gastite.com/flashshield. Or email us at [email protected] • 1116 Vaughn Parkway • Portland, TN 37148 • 1-800-662-0208
Metal mesh layer dissipates electricity
New fittings provide continuity with metal mesh
NO additional manufacturer bonding required
Quick and easy installationWith no spacing requirements, FlashShield CSST is easy to install. Just follow the five simple steps outlined above.
No additional bonding requiredFlashShield features the same level of installation convenience as our conventional CSST, with one key difference: there are no additional bonding requirements outside those mandated by national and local codes.
New fitting design FlashShield CSST boasts a new fitting design that provides perfect continuity with the new layer of metal mesh.
Patent-Pending Penetrating Feature creates Electrical Continuity between fitting and metal mesh
Self-guiding assembly to ensure perfect flare
Tool-less design, no special tools required
All components fully re-usable
Cut to length Strip jacket Install nut and bushings
Position bushings Wrench fitting
61600_FlashShield_PB_Install 2 sided 4C 8.5 x 11 plus bleed Front