Top Banner
FLAMEBAR BW11 FIRE RATED DUCTWORK Value Engineering Breakthrough 1
31
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Flamebar BW11 - Fire rated ductwork.

FLAMEBAR BW11 FIRE RATED DUCTWORK

Value Engineering

Breakthrough1

Page 2: Flamebar BW11 - Fire rated ductwork.

2

FIRESRAY INTERNATIONAL LTD.

INTRODUCTION

Page 3: Flamebar BW11 - Fire rated ductwork.

Firespray International Ltd, part of the Hotchkiss Group is the manufacturer of the world’s leading fire rated duct system – Flamebar BW11.

With manufacturing facilities based in the United Kingdom and in Malaysia, Firespray International is well positioned to serve a demanding and increasingly challenging marketplace.

With more than 20 years of proven successful installations throughout North America, Europe, the Middle East, and Asia, the Flamebar BW11 system has become the product of choice for Architects, Engineers and Contractors.

3

Page 4: Flamebar BW11 - Fire rated ductwork.

- Flamebar BW11 is a

specially formulated water-based compound, contains selected mineral filters

- With the thickness of approximately 1mm, has been successfully tested for international conditions - in excess of four hours duration.

4

Page 5: Flamebar BW11 - Fire rated ductwork.

Specifications : Ductwork tested to DW144 and/or SMACNA standards. The coating shall be of minimum 0.7mm thickness.

Fire rated ductwork constructed for ventilation/smoke extract systems tested to BS476 Part 24 (1987) and ISO6944 (1985) up to 4 hours Stability, Integrity shall be submitted.

5

Page 6: Flamebar BW11 - Fire rated ductwork.

6

Stability: The ability of the duct remain intact and fulfill its intended function for a specified period of time.

Integrity: The ability of the duct to remain free of cracks, holes or openings for a specified period of time.

Insulation: Max. average temperature on the external surface is 140C above ambient (and 180 degree C at any one point).

ISO – 6944- Stated in Hours for the Following Criteria

Page 7: Flamebar BW11 - Fire rated ductwork.

The completed system has been tested to British Standard 476 Part 24 (1987), UL Accreditation, LPCB and ISO 6944 (1985) and Local Test from Fire Department.

7

Certificates

Page 8: Flamebar BW11 - Fire rated ductwork.

8

Page 9: Flamebar BW11 - Fire rated ductwork.

Advantages

9

Significant savings

Page 10: Flamebar BW11 - Fire rated ductwork.

Light-weight (only additional 1.5kg/m2 average base on 1mm thick coating), particularly for smoke extract ducts .

Space-saving (nominal thickness 1mm), particularly for smoke extract ducts

10

Page 11: Flamebar BW11 - Fire rated ductwork.

Easy to apply (at ground level), in duct factory or on site. Repair at field easily.

Quick and easy to install (like installing normal air-conditioning ducts)

11

Page 12: Flamebar BW11 - Fire rated ductwork.

Damage-resistant surface : during transportation or ducting installation

Water resistant :not support mould growth . Cost-efficient : almost no material waste A complete and internationally

tested/certificated fire rated ductwork system, Certified upon final inspection.

12

Page 13: Flamebar BW11 - Fire rated ductwork.

13

Flexibility :it can be applied on all kinds of duct shapes i.e. rectangular, oval shaped, round ducts etc.

Page 14: Flamebar BW11 - Fire rated ductwork.

14

Page 15: Flamebar BW11 - Fire rated ductwork.

Many different projects worldwide illustrate the versatility and flexibility of the Flamebar BW11 fire rated duct system that makes it the system of choice for our clients.

15

Burj Al Arab International 7* Hotel

Page 16: Flamebar BW11 - Fire rated ductwork.

16

Burj Khalifa Tower ( the tallest building in the world)

Ferrari theme park- Abu Dhabi

Page 17: Flamebar BW11 - Fire rated ductwork.

17

Heathrow airport The Gautrain, South Africa

Page 18: Flamebar BW11 - Fire rated ductwork.

18

American First National Bank

Page 19: Flamebar BW11 - Fire rated ductwork.

J.W Marriot Hotel - Hanoi

19

In

Vie

tnam

Page 20: Flamebar BW11 - Fire rated ductwork.

20

Page 21: Flamebar BW11 - Fire rated ductwork.

21

International west-lake hotel in Hanoi

Page 22: Flamebar BW11 - Fire rated ductwork.

22

Page 23: Flamebar BW11 - Fire rated ductwork.
Page 24: Flamebar BW11 - Fire rated ductwork.

Trang Ti n Plazaề

Page 25: Flamebar BW11 - Fire rated ductwork.

25

Complete System TechnologyDuctwork is assembled on site utilizing tested fireproof

Gaskets/sealants

Installation by HVAC contractors supported by the factory, issued installation guidelines

If required, factory inspected and issued a “Certificate of Conformity”

Page 26: Flamebar BW11 - Fire rated ductwork.

26

References:

Page 27: Flamebar BW11 - Fire rated ductwork.

27

“We then came to realize, FlameBar BW11 requires less space needed to create the 2 hr. fire-

rate enclosure. We managed to gain several square feet at an average cost of $300 per square foot – the value really adds up. As it turned out,

there are no special tools needed making the FlameBar BW11 solution mechanically

simplistic. .”

Joseph Darnaby, - Manager of Stiles Construction

References:

Page 28: Flamebar BW11 - Fire rated ductwork.

28

References:

Bill Encinosa - Cohen Freedman Encinosa & Associates,

USA

“Before using FlameBarBW11 we were subject to anywhere from 3 - 6 inspections on drywall shaftwall. These can take days even weeks to schedule. Now our 2-hour fire rated duct wall is inspected immediately,

one time and one time only. The time we save is priceless.”

Page 29: Flamebar BW11 - Fire rated ductwork.

29

FOR FUTHER INFORMATION PLEASE REFER TO TCBM.

(+84 8) 39956957/ 39959530

[email protected]

Page 30: Flamebar BW11 - Fire rated ductwork.

Q & A

30

Page 31: Flamebar BW11 - Fire rated ductwork.

Thank you for your attention !

FLAMEBAR BW11 FIRE RATED DUCTWORK

31