With restructuring of power sector in Pakistan and increase in economic, commercial & industrial activities, more power utilities and other customers demanded high value packaged solutions for their Distribution net work, transmission systems, Power generation and enterprise electrification requirements. To meet this demand FNP established an Engineering Procurement and Construction division. FNP’s EPC Division consists of human resource with high academic qualifications and experience of local as well as global market. The EPC division delivers custom designed and built solutions in following areas: 132kV and 220kV grid stations for power utility companies 132kV and 11kV substations for industrial and commercial customers Integration of private captive power generation plants into utility network for sale of their surplus power to utility companies Power delivery systems for Independent Power Producers (IPPs) Electrical Plant for, Thermal & Hydro Power Units Electrification of commercial, housing projects and industrial parks Security & surveillance system Our services include: Design & Engineering Project Management Project Execution Turnkey or customized projects Automations, Hi-tech Systems & Solution Field Services for Erection, Testing & Commissioning Maintenance of Plant/Equipment In this regards we have ISO certified manufactures / supplier around the world some are mention below;- Eurogulf Transformer FZC from U.A.E (Manufacturer of Distribution & Power Transformers with collaboration of MACE S.a.s Italy). HOBUT from England SEZ - Krompachy from Slovakia IME from Italy. Conta-Clip from Germany RTR Energia from Spain Conputronics Control from UK Algodue Elettronica S.R.L from Italy. Arteche from Spain Korps from Korea Nikdim from Bulgaria Schrack from Austria 1 1
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
With restructuring of power sector in Pakistan and increase in economic, commercial & industrial
activities, more power utilities and other customers demanded high value packaged solutions for their
Distribution net work, transmission systems, Power generation and enterprise electrification
requirements.
To meet this demand FNP established an Engineering Procurement and Construction division. FNP’s EPC
Division consists of human resource with high academic qualifications and experience of local as well as
global market. The EPC division delivers custom designed and built solutions in following areas:
132kV and 220kV grid stations for power utility companies
132kV and 11kV substations for industrial and commercial customers
Integration of private captive power generation plants into utility network for sale of their
surplus power to utility companies
Power delivery systems for Independent Power Producers (IPPs)
Electrical Plant for, Thermal & Hydro Power Units
Electrification of commercial, housing projects and industrial parks
Security & surveillance system
Our services include:
Design & Engineering
Project Management
Project Execution
Turnkey or customized projects
Automations, Hi-tech Systems & Solution
Field Services for Erection, Testing & Commissioning
Maintenance of Plant/Equipment
In this regards we have ISO certified manufactures / supplier around the world some are mention below;-
Eurogulf Transformer FZC from U.A.E (Manufacturer of Distribution & Power Transformers with collaboration of MACE S.a.s Italy).
HOBUT from England
SEZ - Krompachy from Slovakia
IME from Italy.
Conta-Clip from Germany
RTR Energia from Spain
Conputronics Control from UK
Algodue Elettronica S.R.L from Italy.
Arteche from Spain
Korps from Korea
Nikdim from Bulgaria
Schrack from Austria
1
1
Helukabel GmbH from Germany
Eland from UK
Agro from Switzerland
Cember from Italy
TLA Electrical Distributors Ltd from UK
CAN OZAN PANO from Turkic
Cenit Solar from Spain.
DEIF from UK
Quantum Controls Ltd.
Detail of components & equipments are as under: -
Eurogulf Transformer FZC o Distribution Transformers up to 4000 KVA, up to operational Voltage is 36 KV. o Power Transformer up to 100 MVA, up to operational Voltages is 132 KV. o Multi Tap Transformers to suit from 35Hz to 80Hz frequency System for VSD
application. o Special application motor starting auto transformers with full or intermittent
ratings. o Dry type varnish impregnated transformers for special applications. o Cast resin Transformers up to 5000 KVA.
HOBUT from England
o Analogue/ Digital Ammeters & Volt Meters o Analogue/ Digital PF Meters o Analogue/ Digital Frequency Meters o Analogue/ Digital Mega Var Meters o Analogue/ Digital Mega Watt Meters o Power Transducers o Digital Multi Function Meter M850 o Digital Multi Function Meter M812 o Single Phase Current Transformers (CT’s) o Three Phase Current Transformers (CT’s) o Earth Leakage Relay + CBCT o Earth Fault Relay o Over Current Relay
SEZ - Krompachy from Slovakia
o AC MCB’s o DC MCB’s o Cam/Selector Switches
2
o Rotary Switches o AC Contactor o DC Contactor o Auxiliary Contactor o Auxiliary contact
IME from Italy. o Multifunction Meter o Transducers single & multifunction o Digital Static energy Meters with & without GSM modem. o Differential Relays o Insulation Relays o Measuring Relays. o Current Transformers with built-in transducer.
Conta-Clip from Germany
o Terminal Blocks / Connectors o Earth Terminal Blocks o CT Short Link Terminals o Fuse Terminals o Stoppers & End Plates o Numbering
RTR Energia from Spain
o L.V Capacitors o M.V Capacitors o Power Factor Controllers
Conputronics Control from UK
o Battery Chargers Algodue Elettronica S.R.L from Italy.
o Energy control solutions o Intelligence systems developed for professional security operations and authorized
investigations. o GPS systems solutions for monitoring moving objects, property, people
Arteche from Spain
Korops from Korea
Nikdim from Bulgaria
Schrack from Austria
Helukabel GmbH from Germany
o Control cables copper shielded and unshielded.
o LV Power Cables.
Eland from UK
o Control Cables, Instrumentation Cables.
3
o Power Cables.
Agro from Switzerland
o Cable glands.
Cember from Italy
o Cables lugs – bimetallic
o Cables Terminal Insulated & un-insulated
o Polyamide high temperature Cable ties.
o Steel Cable ties.
TLA Electrical Distributors Ltd from UK
o Eriflex – Low voltage Power Distribution such as Busbar support Flexibar –
insulated busbar up to 2300A.
o Eritech – Facility Electrical Protection
o CADWELD – Electrical Grounding and Bonding.
o CRITEC – Surge Protection devices.
o ERITECH – Grounding Products.
o ERITECH – Lightning Protection Products.
o CADDY – Electrical Fixings, Fasteners and supports.
o CADDY – Mechanical Fixing, Fasteners and supports.
o PULS – DIN Power Supply.
o Fulleon – Sounder & Beacon
o VACON – Inverter Drive.
CAN OZAN PANO from Turkic
o Power distribution panels as IP65, IP55 class.
o Control and automation enclosures as per IP65, IP55 class.
o Synchronization / Parallel gen. set control Panel as IP65, IP55.
o Test Benches as per IP65, IP55.
Cenit Solar from Spain.
o Off grid / On grid Solar system up to 2MWatt.
o Solar water pumping systems – deep well & dewatering.
o Solar Heating system.
DEIF from UK
o Gas engine control unit.
o Generator protection unit.
o Multiple parallel control units.
Quantum Controls Ltd From UK.
o ABB Variable Speed Drives.
o ABB Motors.
o Refurbished Variable Speed derives.
o ABB Motor Gear.
o ABB LV Control Panels (Distribution & Process Control Panels).
4
CONTACTS
Head Office: 155-A, Sarfraz Rafiqui Road, Lahore Cantt, Lahore.
It is the ability of organising and estimating thedata of our everyday experience that makes us toprogress. This estimation is carried out by means of an artwhich enables us to choose among things differentfrom one another by comparing some of theircharacteristics. It is the art of weighing, counting and measuring.
ISTRUMENTI MISURE ELETTRICHE SpA
ISTRUMENTI MISURE ELETTRICHE SpA
7
ISTRUMENTI MISURE ELETTRICHE SpA
ISTRUMENTI MISURE ELETTRICHE SpA
I
Nemo 96 HD Nemo 96 HD
Twins, but differentAs with people, you need only one look to knowthat we are dealing with twins: same physicalstructure, same features, same colour of eyes andhair. But if we want to catch what makes them similarand what distinguishes them, then, as with people, asingle look is no longer enough: we need to knowthem more closely.
Why are different
What distinguishes the two products is definitely the use they are intended for: 96 HD is intended for low voltage applications, while 96 HD+ for both lowand medium voltage applications. This implies some important differences, that is to say, a proper insulation class for voltage and current inputs,
Complete compatibility for optional modules: one module can be installed on any of the two modelswithout limitation; both models can accept up to4 modules at the same time.Same possibility of network connection (single-phase,three-phase 3 or 4 wires).Same reading of measurements and parameterprogramming for the two models; same direct and derived electrical quantities, same energy and time count, same data storing.The software can be updated on field.
Nemo 96 HD+Nemo 96 HD Nemo 96 HD
Nemo 96 HD+
What do have in common
The structure and the mechanical dimensions, the flush mounting fixing system, the expandability of the functions by means of optional modules.The backlit display, characterised by high visibility and information content, and a 4-button keypad for the dialogue man-machine.
bt
and a more complete programming menu that allowsto define specific functioning conditions as, for example, in case of connection by means of current and voltage transformers, linked in medium voltage networks.
MT
8
P•Q•SActive powerReactive powerApparent powerPhase and three-phase instantaneous valueAverage value and average value peak
ICurrentInstantaneous phase and neutral valueHarmonic distortion for phaseAverage value and average value peak
UVoltageInstantaneous valueMin and max valueHarmonic distortion
E•TEnergy counting Total and partial activePositive and negative activeTotal and partial reactivePositive and negative reactivePower factorPhase and three-phase instantaneous valueFrequencyInstantaneous valueHourmeterWorking hour counting
9
Communication interfaceAccording to standard RS 232-C. Communication speed programmable up to 38,400 bit/s.
Communication interfaceAccording to standardPROFIBUS.Communication speedup to 3Mb.
Same modules for: Nemo 96 HD Nemo 96 HD
Communication interfaceAccording to standard RS 485. The protocol used is MODBUS RTU; on demand, implementation of proprietary protocols can be provided.Communication speed programmable up to 38,400 bit/s.
Analogue outputTwo independent andisolated channelswith output current0…20mA and/or 4…20 mA. The association betweenquantities measured and analogue outputs is definedat module’s installation.
Expansion modulesThe seven following expansion modules are available in the kit of Nemo 96 HD and 96 HD+. The modules can be used without limitation on bothmodels, which can accept up to 4 modules each.
Pulse emitter for energy countTwo isolated optorelaysprogrammable independently (time ON and weight of associated energy) foractive and reactive energy. Contacts: SPST-NO.
AlarmsTwo independent and isolated alarm relays with programmable functions.Contacts: SPST.
Inserzione diretta fino a 500V Direct connection up to 500V
NT51
4 04
- 20
10 5
aEd
.pag
.1/6
Tema fPTrasduttoreprogrammabile
8 Moduli
Un solo apparecchio per tutte le inserzioni,linea monofase e trifase
Completamente configurabile in campoIngresso tensione trifase diretta fino a 500V
e su TV/100 e 115VIngresso corrente da TA/5A opp. /1A
Misura in vero valore efficace
Misure associabili all’uscita:Potenza attiva
Potenza reattivaPotenza apparenteFattore di potenza
Angolo di fasePotenza media
Frequenza
Uscita realizzabile con tutti i segnali standard
0...5/10/20mA - 4...20mA0...10V - 1...5V
Programmable transducer8 Module
Just one meter for single-phase and 3-phase connectionsWholly field programmableDirect three-phase voltage input up to 500V andthrough V.T. 100 and 115V Current input C.T/5A or /1ATrue R.M.S. measurements
Measured quantity: Active powerReactive powerApparent powerPower factorPhase anglePower demandFrequency
Output possible with all standard signals0...5/10/20mA - 4...20mA0...10V - 1...5V
TRASDUTTORITRANSDUCERS
Grandezza Quantity
Uscita Output
14
MISUREMEASURE
LINEA MONOFASESINGLE PHASE LINE
S250/97
LINEA TRIFASE THREE PHASE
3 FILI EQUILIBRATABALANCED LOAD 3-WIRE
S250/93 S250/100
4 FILI EQUILIBRATABALANCED LOAD 4-WIRE
S250/95
3 FILI SQUILIBRATAUNBALANCED LOAD 3-WIRE
S250/94/96/98
4 FILI SQUILIBRATAUNBALANCED LOAD 4-WIRE
S250/99
Potenza attiva monofaseSingle phase active power •
Potenza attiva L1-NActive power L1-N N •
Potenza attiva L2-NActive power L2-N •
Potenza attiva L3-NActive power L3-N •
Potenza attiva trifaseThree phase active power • • • •Potenza reattiva monofase
Single phase reactive power •Potenza reattiva L1-NReactive power L1-N N •Potenza reattiva L2-NReactive power L2-N •Potenza reattiva L3-NReactive power L3-N •
Potenza apparente monofaseSingle phase apparent power •
Potenza apparente L1-NApparent power L1-N N •
Potenza apparente L2-NApparent power L2-N •
Potenza apparente L3-NApparent power L3-N •
Potenza apparente trifaseThree phase apparent power • • • •Fattore di potenza monofase
Single phase power factor •Fattore di potenza L1-N
power factor L1-N N •Fattore di potenza L2-N
power factor L2-N •Fattore di potenza L3-N
power factor L3-N •Fattore di potenza trifaseThree phase power factor • • • •Angolo di fase monofasephase angle, single phase •
Angolo di fase trifasephase angle, three phase • •
Potenza mediapower demand • • • • • •
Valore massimo potenza mediapower max. demand N N N N N N
FrequenzaFrequency • • • • • •
CODICI DI ORDINAZIONEORDERING CODE
INGRESSOINPUT
AL. AUSILIARIA AUX. SUPPLY
TM8P02110 1A 80...500V 115V ca / ac
TM8P02120 5A 80...500V 115V ca / ac
TM8P03110 1A 80...500V 230 - 240V ca / ac
TM8P03120 5A 80...500V 230 - 240V ca / ac
TM8P0H110 1A 80...500V 20...150V cc / dc
TM8P0H120 5A 80...500V 20...150V cc / dc
TM8P0L110 1A 80...500V 150...250V cc / dc
TM8P0L120 5A 80...500V 150...250V cc / dc
NT51
4 04
- 20
10 5
aEd
.pag
.2/6
• Grandezze visualizzate che possono essere trasdotte (associabili all’uscita analogica) Display quantities which can be transduced (which can be associated to the analog output)
N Grandezze solamente visualizzate (non possono essere associabili all’uscita analogica) Quantities displayed only (which cannot be associated to the analog output)
15
INGRESSO
Rete monofase, rete trifase 3 e 4 fili, carico equilibrato squilibratoInserzione: diretta o da TV e TA esterni (con rapporti programmabili)Rapporti TA e TV: programmabili, KTA x KTV ≤ 220.000 (In 5A) - ≤ 2.000.000 (In 1A)Tensione trifase nominale Un: 400V (fase - fase)Tensione monofase: 50...300VCorrente In: 5A oppure 1AFrequenza fn: 50HzEccedenza di breve durata (EN 60688): 2Un/1s - 20In/1sAutoconsumo (per ogni fase): tensione ≤ 0,5VA - corrente 0,5VA
CAMPI NOMINALI DI UTILIZZO (EN 60688)
Tensione trifase: 80...500V (fase - fase)Corrente: 0...120% InFrequenza: 45...65HzFattore di potenza: cosϕ 0,5...1...0,5 − senϕ 0,5...1...0,5Contenuto armonico: fino alla 16a armonica
IMPOSTAZIONE CAMPO DI USCITA
Programmabile: tramite tastieraPotenza corrispondente al fondo scala: 50...150% PnMinimo ∆ inizio - fondo scala: 25% Pndove:Pn (potenza nominale) = Un x In x √3Un (tensione nominale) = 400V (inserz. diretta) - 100V (inserz.su TV esterno)In (corrente nominale) = 5A oppure 1A
POTENZA MEDIA
Visualizzazione e misura: potenza media e valore massimo potenza mediaGrandezza: potenza attiva, reattiva o apparenteTempo di media: selezionabile 5/8/10/15/20/30/60 minutiCalcolo: media fissa sul periodo selezionatoAzzeramento valore massimo potenza media: manuale, da tastiera
VISUALIZZAZIONE
Tipo display: LCDVisualizzazione misure: suddivisa in differenti pagine, con scansione manualeUnità ingegneristica: visualizzazione automatica misure lato primario (TA-TV esterni)
Connessione: rete monofase - trifase (3 - 4fili), carico equilibrato - squilibratoTA -TV esterni: rapporto KTA x KTV ≤ 220.000 (In 5A) - ≤ 900.000 (In 1A)Uscita analogica: grandezza associata, inizio e fondo scala, valore nominale dicorrente (o tensione)Potenza media: grandezza, tempo di media, azzeramento
USCITA
Grandezze associabili: vedi tabellaTipo: uni e bidirezionale a zero reale e traslato, per carico d'uscita variabilePrecisione (EN 60688): cl.0,5 (potenza) - cl.1 (fattore di potenza) - ± 0,2Hz (frequenza)Ondulazione (EN 60688): ≤ 1%Tempo di risposta (EN 60688): ≤ 300msValori nominali di corrente: 0...5 - 5...0...5 - 0...10 - 10...0...10 -
Single phase, three phase network, 3 and 4 wire, balanced and unbalanced loadConnection: direct or by external VT and CT (with programmables ratios)VT and CT ratios: programmables, KVT x KCT ≤ 220.000 (In 5A) - ≤ 2.000.000 (In 1A)Three-phase voltage rating Un: 400V (phase – phase)Single-phase voltage: 50...300VCurrent rating In: 5A or 1AFrequency fn: 50HzExcessive input of short duration (EN 60688): 2Un/1s - 20In/1sRated burden (each phase): voltage ≤ 0,5VA - current ≤ 0,5VA
NOMINAL RANGE OF USE (EN 60688)
Voltage three-phase: 80...500V (phase – phase)Current: 0...120% InFrequency: 45...65HzPower factor: cosϕ 0,5...1...0,5- senϕ 0,5...1...0,5 Harmonic content: up to 16th harmonic
OUTPUT RANGE SETTING
Programmable: by keyPower corresponding to full scale: 50...150% pn∆ min. beginning - full scale: 25% pnwhere:Pn (nominal power) = Un x In x √3Un (nominal voltage) = 400V (direct connection) - 100V (external VT)In (nominal current) = 5A or 1A
POWER DEMAND
Measuring and display: power demand and power max. demandQuantity: active, reactive or apparent powerAveraging time period: selectable 5/8/10/15/20/30/60 minutesCalculation: Average on a selected time intervalMax. demand reset: manual, by keyboard
DISPLAY
Display type: LCDMeasurement display: subdivided on pages, with manual scrollEngineering units: automatic display according to the set VT and CT ratios
PROGRAMMING
Parameters programming: front keyboard, 3 keysHold of configuration parameters: non volatile memory
PROGRAMMABLE PARAMETERS
Connection: single phase - three phase network (3 - 4wire), balanced andunbalanced load External VT - CT: ratio KTA x KTV ≤ 220.000 (In 5A) - ≤ 900.000 (In 1A)Analog output: transduced quantity, beginning and full scale, standard outputPower demand: quantity, averaging time period, reset
OUTPUT
Associable quantities: see tableType: unidirectional and reversible, real or live zero for variable output loadAccuracy (EN 60688): cl.0,5 (power) - cl.1 (power factor) - ± 0,2Hz (frequency)Ripple content (EN 60688): ≤ 1%Response time (EN 60688): ≤ 300msCurrent rated values: 0...5 - 5...0...5 - 0...10 - 10...0...10 -
Valori nominali di tensione: 0...10V - 10...0...10 - 1...5VCarico di uscita: ≥ 5kΩ
ALIMENTAZIONE AUSILIARIA
Valore nominale Uaux ca: 115 – 230 e 240VVariazione ammessa: 0,85…1,1UauxFrequenza nominale faux: 50HzVariazione ammessa: 47…63HzAutoconsumo: ≤ 3VAValore nominale Uaux cc: 20…150Vcc -150...250VccAutoconsumo: ≤ 3WProtezione contro l’inversione di polarità
PROVE DI ISOLAMENTO (EN 60439-1)
Categoria di installazione: IIIGrado di inquinamento: 2Tensione di riferimento per l’isolamento: 500VProva di tensione a impulso 5kV 1,2/50μs 0,5JCircuiti considerati: ingresso, uscita, alimentazione ausiliariaProva di tensione alternata 2,5kV valore efficace 50Hz/1 minCircuiti considerati: ingr.tensione, ingr.corrente, uscita, alimentazione ausiliaria Prova di tensione alternata 4kV valore efficace 50Hz/1 minCircuiti considerati: alimentazione ausiliaria verso tutti gli altri circuitiProva di tensione alternata 4kV valore efficace 50Hz/1 minCircuiti considerati: tutti i circuiti e massa
COMPATIBILITA' ELETTROMAGNETICA
Prove di emissione in accordo con EN61000-6-3Prove di immunità in accordo con EN61000-6-2
CONDIZIONI AMBIENTALI (EN 60688)
Gruppo di utilizzo: IITemperatura di riferimento: 15...30°CTemperatura di impiego: 0...50°CCondizione limite di temperatura: -10...55°C Temperatura di immagazzinaggio: -25...70°CAdatto all’utilizzo in clima tropicaleMassima potenza dissipata 1: ≤ 4,8W1 Per il dimensionamento termico dei quadri
CUSTODIA
Dimensioni: 8 moduli DIN 43880Connessioni: morsetti a vite per conduttore fino a 4mm2 (amperometriche 8mm 2)Montaggio: a incastro su profilato 35mmTipo profilato: a cappello TH35-15 (EN60715)Materiale custodia: policarbonato autoestinguenteGrado di protezione (EN 60529): IP52 (frontale), IP20 (morsetti)Peso: 480 grammi
Rated value Uaux ac: 115 – 230 and 240VTolerance: 0,85…1,1UauxRated frequency faux: 50HzTolerance: 47…63HzRated burden: ≤ 3VARated value Uaux dc: 20…150Vdc -150...250VdcRated burden: ≤ 3WProtected against incorrect polarity
TESTS OF INSULATION PROPERTIES (EN 60439-1)
Installation category: IIIPollution degree: 2Insulation voltage rating: 500VImpulse voltage test 5kV 1,2/50μs 0,5JConsidered circuits: input, output, auxiliary supply A.C. voltage test 2,5kV r.m.s. 50Hz/1 minConsidered circuits: voltage input , current input, output, auxiliary supplyA.C. voltage test 4kV r.m.s. 50Hz/1minConsidered circuits: auxiliary supply toward all circuitsA.C. voltage test 4kV r.m.s. 50Hz/1minConsidered circuits: all circuits and earth
ELECTROMAGNETIC COMPATIBILITY
Emission test according to EN61000-6-3Immunity test according to EN61000-6-2
ENVIRONMENTAL CONDITIONS (EN 60688)
Usage group: IIReference temperature: 15...30°CNominal temperature range: 0...50°CLimit temperature range: -10...55°CLimit temperature range for storage: -25...70°CSuitable for tropical climatesMax. power dissipation 1: ≤ 4,8W1 For switchboard thermal calculation
HOUSING
Dimensions: 8 module DIN 43880Connections: screw terminals for cable up to 4mm 2 (ammetric 8mm 2)Mounting: snap-on 35mm rail Rail type: top hat TH35-15 (EN60715)Housing material: self-extinguishing policarbonateProtection degree (EN 60529): Ip52 (front frame); Ip20 (terminals)Weight: 480 grams
NT51
4 04
- 20
10 5
aEd
.pag
.4/6
17
SCHEMI D’INSERZIONE WIRING DIAGRAMS
2 5 7 9
OUTPUTINPUT
8 4 61 3
X
S1
P1L
N
11
2 11
1214 1517
+ -mA- V
13 20
AUX.SUPPLY
2121+ –CURRENTVOLTAGE
NT51
4 04
- 20
10 5
aEd
.pag
.5/6
2 5 7 98 4 61 3
X
XX
2 5 8
S1
P1
a
AL1
L2
L3
11
2 5 8
OUTPUTINPUT
1214 1517
+ -mA- V
13 20
AUX.SUPPLY
2121+ –CURRENTVOLTAGE
OUTPUT
1214 15
OUTPUT
17 131214 1517
+ -mA- V
13
+ -mA- V
V mA
2 5 7 98 4 61 3
XXX
X
XX
2 5 8
S1
P1
a
AL1
L2
L3
N
11
11
OUTPUTINPUT
1214 1517
+ -mA- V
13 20
AUX.SUPPLY
2121+ –CURRENTVOLTAGE
USCITA ANALOGICA ANALOG OUTPUT
LINEA MONOFASE • SINGLE PHASE
LINEA TRIFASE 3 FILI, CARICO EQUILIBRATO
THREE PHASE 3 WIRE, BALANCED LOAD
LINEA TRIFASE 4 FILI, CARICO EQUILIBRATO
THREE PHASE 4 WIRE, BALANCED LOAD
2 5 7 98 4 61 3
X
XX
S1
P1L1
L3
11
5 8
L2
OUTPUTINPUT
1214 1517
+ -mA- V
13 20
AUX.SUPPLY
2121+ –CURRENTVOLTAGE
S 250/97
S 250/93
S 250/100
S 250/95
18
La I.M
.E. S
.p.A.
si ris
erva
in qu
alsias
i mom
ento,
di m
odific
are l
e car
atter
istich
e tec
niche
senz
a dar
ne pr
eavv
iso. /
I.M.E
. S.p.
A. re
serve
s the
right,
to m
odify
the t
echn
ical c
hara
cteris
tics w
ithou
t noti
ce.
NT51
4 04
- 20
10 5
aEd
.pag
.6/6
2 5 7 98 4 61 3
X
XX
2 5 8
a
AL1
L2
L3
11
2 5 8
S1
P1
S1
P1
OUTPUTINPUT
1214 1517
+ -mA- V
13 20
AUX.SUPPLY
2121+ –CURRENTVOLTAGE
2 5 7 98 4 61 3
X
XX
2 5 8
S1
P1
a
AL1
L2
L3
11
2 5 8
S1
P1
OUTPUTINPUT
1214 1517
+ -mA- V
13 20
AUX.SUPPLY
2121+ –CURRENTVOLTAGE
2 5 7 98 4 61 3
X
XX
2 5 8
S1
P1
a
AL1
L2
L3
11
2 5 8
S1
P1
OUTPUTINPUT
1214 1517
+ -mA- V
13 20
AUX.SUPPLY
2121+ –CURRENTVOLTAGE
LINEA TRIFASE 3 FILI, CARICO SQUILIBRATO
THREE PHASE 3 WIRE, UNBALANCED LOAD
140
89,5
69
45
DIMENSIONI DIMENSIONS
2 5 7 98 4 61 3
XXX
X
XX
2 5 8
S1
P1 S1
P1 S1
P1
a
AL1
L2
L3
N
11
11
OUTPUTINPUT
1214 1517
+ -mA- V
13 20
AUX.SUPPLY
2121+ –CURRENTVOLTAGE
LINEA TRIFASE 4 FILI, CARICO SQUILIBRATO
THREE PHASE 4 WIRE, UNBALANCED LOAD
S 250/99
S 250/94
S 250/96
S 250/98
19
1.5 I 2
200 400
0
V
482
600
300
100 500
V
0...5mA
0...10mA
0...20mA
4...20mA
0...5V
0...10V
2...10V
NT555 03 - 2011 8aEd.pag.1/3
Tema U4Trasduttore di tensione alternata
2 Moduli
Misura del valor medio, taratura rapportata al valore efficace
Ingresso diretto fino a 500VUscita selezionabile in campo (7 portate)
Valori selezionabili: 0…5/10/20mA - 4…20mA
0…5/10V - 2…10V
Alternating voltage transducer2 Module
To measure average value, calibration according RMS valueDirect input up to 500VOutput selectable on field (7 ranges)
Prove di emissione in accordo con EN 50081-1, EN 55011
Prove di immunità in accordo con EN 50082-2
Prova di disturbo ad alta frequenza, onda oscillatoria smorzata 1MHz (IEC255-4)
Tensione di prova: 2,5kV modo comune, 1kV modo serie
CONDIZIONI AMBIENTALI
Gruppo di utilizzo: II
Temperatura di riferimento: 15…30°C
Temperatura di impiego: 0…45°C
Condizione limite di temperatura: -10…55°C
Temperatura di magazzinaggio: -25…70°C
Umidità relativa: fino a 75%
Adatto all’utilizzo in clima tropicale
Massima potenza dissipata1: ≤ 2,6W1Per il dimensionamento termico dei quadri
CUSTODIA
Dimensioni: 2 moduli DIN 43880
Connessioni: morsetti fissaggio a vite per conduttore fino a 4mm2
Montaggio: a incastro su profilato 35mm
Tipo profilato: a cappello TH35-15 (EN60715)
Materiale custodia: makrolon autoestinguente
Grado di protezione (EN 60529): IP40 (frontale), IP20 (morsetti)
Peso: 200 grammi
25
NT791 01 - 2013 0 Ed.
pag.1/4
ANIndicatori AnalogiciAQMrad
per tensione alternata48x48mm72x72mm96x96mm
Indicazione diretta della tensione di ingresso odella tensione primaria del TV esterno
Equipaggio a bobina mobile,con accessorio raddrizzatoreIngresso diretto da 10 a 600V
Ingresso da TV esterno /100V - /110VAmpiezza scala 240°
Precisione cl.1,5
AQMradAnalog Meters for alternating voltage48x48mm72x72mm96x96mm
Direct indication of input voltage or primaryvoltage of external VTMoving coil equipmentwith rectifier accessoryDirect connection 10...600VInput by external VT /100V - /110VScale lenght 240°Accuracy class 1,5
INDICATORI ANALOGICIANALOG METERS
Scala intercambiabileInterchange scales
AQ72Mrad - AQ96Mrad Coprimorsetto di serieStandard terminal cover
26
Opzione / Option Suffisso / Suffix Esempio / Example
TropicalizzatoTropicalized
Aggiungere “1” al codice standardAdd “1” at the end of standard code AN65DDC300 ⇒ AN65DDC3001
Protezione frontale IP54IP54 Front protection
Aggiungere “3” al codice standardAdd “3” at the end of standard code AN65DDC300 ⇒ AN65DDC3003
Altre esecuzioni disponibili su tutti i modelli: Other executions available on all models:
NT791 01 - 2013 0 Ed.
pag.2/4
INSERZIONE SU TV
Dati da indicare oltre al codice di ordinazione
Scala e rapporto TV
Il valore della scala dovrà corrispondere al prodotto tra il valore di portata
scelto e il rapporto del TV
Es. portata 120V – rapporto TV 500/100V = valore scala = (120 x 500) : 100 = 600V
Solo per cod. AN54P11111 - AN64P11111 - AN74P11111: scala e rapporto TV
Es. scala 0...300V – rapporto TV 230/100V
VISUALIZZAZIONE
Scala: intercambiabile, con inserimento guidato a protezione dell’indice e cassettino
di chiusura
Colore scala: fondo bianco, divisioni e numerazione nere
A richiesta scale personalizzate
Opzioni: segno rosso di riferimento
Ampiezza scala: 240°
Tracciatura standard: 0...Un
Colore indice: nero
Opzione: indice rosso di riferimento (regolabile)
CONNECTION ON VT
Data to be shown in addition to ordering code
Scale and VT ratio
The scale value must correspond to the result between the chosen range
value and the VT ratio
Ex. range 120V – VT ratio 500/100V = scale value = (120 x 500) : 100 = 600V
Only for code AN54P11111 - AN64P11111 - AN74P11111: scale and VT ratio
Ex. scale 0...300V – VT ratio 230/100V
DISPLAY
Scale: interchangeable, easy-insertion to protect the pointer as wellas relevant
closing slip
Scale colour: white background, black divisions and numbering
Customized scales upon request
Option: reference red mark
Scale length: 240°
Standard scale marking: 0...Un
Pointer colour: black
Option: (adjustable) reference red pointer
InserzioneConnection 0...In - DIRETTA / DIRECT
ModelloModel AQ48Mrad AQ72Mrad AQ96Mrad
DimensioniDimensions 48 x 48 72 x 72 96 x 96
PortataRange CODICE DI ORDINAZIONE / ORDERING CODE
10V AN54DDB100 AN64DDB100 AN74DDB100
15V AN54DDB150 AN64DDB150 AN74DDB150
25V AN54DDB250 AN64DDB250 AN74DDB250
30V AN54DDB300 AN64DDB300 AN74DDB300
40V AN54DDB400 AN64DDB400 AN74DDB400
60V AN54DDB600 AN64DDB600 AN74DDB600
100V AN54DDC100 AN64DDC100 AN74DDC100
150V AN54DDC150 AN64DDC150 AN74DDC150
200V AN54DDC200 AN64DDC200 AN74DDC200
250V AN54DDC250 AN64DDC250 AN74DDC250
300V AN54DDC300 AN64DDC300 AN74DDC300
400V AN54DDC400 AN64DDC400 AN74DDC400
500V AN54DDC500 AN64DDC500 AN74DDC500
600V AN54DDC600 AN64DDC600 AN74DDC600
InserzioneConnection da TV / on VT
ModelloModel AQ48Mrad AQ72Mrad AQ96Mrad
DimensioniDimensions 48 x 48 72 x 72 96 x 96
PortataRange CODICE DI ORDINAZIONE / ORDERING CODE
100V AN54111111 AN64111111 AN74111111
120V AN54211111 AN64211111 AN74211111
125V AN54311111 AN64311111 AN74311111
131,58V AN54411111 AN64411111 AN74411111
133,33V AN54511111 AN64511111 AN74511111
136,36V AN54611111 AN64611111 AN74611111
150V AN54711111 AN64711111 AN74711111
altri valoriother values
AN54P11111 AN64P11111 AN74P11111
27
NT791 01 - 2013 0 Ed.
pag.3/4
INGRESSO
Grandezza: tensione alternata monofase
Inserzione: diretta (S 250/124 - /141) o da TV esterno (S 250/125 - /142)
Misura: valor medio, rapportato al valore efficace, fattore di forma 1,11
Tensione nominale Un
Inserzione diretta: 10...600V
Inserzione da TV esterno: TV/100V - TV/110V
Sovraccarico permanente: 1,2Un
Sovraccarico istantaneo: 10Un/5s
Frequenza nominale fn: 50Hz
Frequenza di funzionamento: 45...65Hz
Precisione (EN/IEC 60051): cl.1,5
Autoconsumo: ≃1mA
ISOLAMENTO (EN/IEC 61010-1)
Categoria di installazione: III
Grado di inquinamento: 2
Tensione di riferimento per l’isolamento: 600V (Fase - Neutro)
Prova a tensione alternata 4kV valore efficace 50Hz/5s
Circuiti considerati: tutti i circuiti verso terra
CONDIZIONI AMBIENTALI
Temperatura di riferimento: 23°C
Campo nominale di utilizzo: 5...40°C
Campo di funzionamento: -25...50°C
Campo limite per l’immagazzinamento e trasporto: -40...80°C
Prova di vibrazioni: in accordo con EN/IEC 60051-1 paragrafo 7.6
Prova d’urto: in accordo con EN/IEC 60051-1 paragrafo 7.6
CUSTODIA
Fissaggio: incasso
Foratura pannello: vedi tabella
Frontale: vedi tabella
Profondità: vedi tabella
Connessioni: morsetti a vite / faston 6,3 x 0,8mm (AQ48Mrad solo faston)
Materiale custodia: policarbonato autoestinguente
Grado di protezione(EN/IEC 60529): IP52 frontale, IP20 morsetti (con coprimorsetto)
Opzione: protezione frontale IP54
Peso: vedi tabella
INPUT
Quantity: single-phase, alternating voltage
Connection: direct (S 250/124 - /141) or by external VT (S 250/125 - /142)
Measure: average value measurement, related to r.m.s value, form factor 1,11
Rating voltage Un
Direct connection: 10...600V
Connection by VT external: VT/100V - VT/110V
Continuous overload: 1,2Un
Istantaneous overload: 10Un/5s
Rating frequency fn: 50Hz
Working frequency: 45..65Hz
Accuracy (EN/IEC 60051): class 1,5
Rated burden: ≃1mA
INSULATION (EN/IEC 61010-1)
Installation category: III
Pollution degree: 2
Insulation rating voltage: 600V (Phase - Neutral)
A.C. voltage test 4kV r.m.s. 50Hz/5s
Considered circuits : all circuits and earth
ENVIRONMENTAL CONDITIONS
Reference temperature: 23°C
Nominal range of use: 5...40°C
Operating range: -25...50°C
Limit range for storage and transport: -40...80°C
Vibration test: according to EN/IEC 60051-1 paragraph 7.6
Shock test: according to EN/IEC 60051-1 paragraph 7.6
HOUSING
Mounting: flush mounting
Panel cutout: see table
Front frame: see table
Depth: see table
Connections: screw terminal / fast-on 6,3 x 0,8mm (AQ48Mrad only fast-on)
ento, di modificare le caratteristiche tecniche senza darne preavviso. / I.
M.E
. S.p
.A. r
eser
ves
the
right
, to
mod
ify th
e te
chni
cal
char
acte
ristic
s w
ithou
t not
ice.
SCHEMI D’INSERZIONE WIRING DIAGRAMS
DIMENSIONI DIMENSIONS
B
AB
A
C
88 98 78
43 52
3,5
LOAD∼
V
S 250/124
a
A
b
B
LOAD∼
V
S 250/125
Accessorio raddrizzatoreper AQ48M/rad
Rectifier accessoryfor AQ48M/rad
Modello / Model Schemi / Diagrams A B C Peso / Weight
AQ48Mrad S 250 / 130 - 131 48x48 45x45 85,5 250 gr.
AQ72MradS 250 / 132 -133
72x72 68x68 84 300 gr.
AQ96Mrad 96x96 92x92 84 350 gr.
AQ48Mrad AQ48Mrad
AQ72/96Mrad AQ72/96Mrad
29
NT790 12 - 2012 1aEd.pag.1/5
ANIndicatori AnalogiciAQMrad
per corrente alternata48x48mm72x72mm96x96mm
Indicazione diretta della corrente di ingresso odella corrente primaria del TA esterno
Equipaggio a bobina mobile, con accessorio raddrizzatore
Ingresso diretto 1...5AIngresso da TA esterno /5A oppure /1A
Versione per avviamento motore 2In opp. 5InAmpiezza scala 240°
Precisione cl.1,5
AQMradAnalog Meters for alternating current48x48mm72x72mm96x96mm
Direct indication of input current orprimary current of external CTMoving coil equipment,with rectifier accessoryDirect connection 1...5AInput by external CT /5A or /1AVersion for starting motor 2In or 5InScale length 240°Accuracy class 1,5
INDICATORI ANALOGICIANALOG METERS
2In
5In
In
Scala intercambiabileInterchange scales
AQ72M - AQ96M Coprimorsetto di serieStandard terminal cover
30
NT790 12 - 2012 1aEd.pag.2/5
InserzioneConnection 0...In - DIRETTA / DIRECT
ModelloModel AQ48Mrad AQ72Mrad AQ96Mrad
DimensioniDimensions 48 x 48 72 x 72 96 x 96
PortataRange CODICE DI ORDINAZIONE / ORDERING CODE
1A AN51D1A100 AN61D1A100 AN71D1A100
2,5A AN51D1A250 AN61D1A250 AN71D1A250
5A AN51D1A500 AN61D1A500 AN71D1A500
Opzione / Option Suffisso / Suffix Esempio / Example
TropicalizzatoTropicalized
Aggiungere “1” al codice standardAdd “1” at the end of standard code AN6151C500 ⇒ AN6151C5001
Protezione frontale IP54IP54 Front protection
Aggiungere “3” al codice standardAdd “3” at the end of standard code AN6151C500 ⇒ AN6151C5003
Altre esecuzioni disponibili su tutti i modelli: Other executions available on all models:
InserzioneConnection da TA/ 5A on CT/5A da TA/ 1A on CT/1A
)DO4-RML No.2 Relay + No.2 Optomos (ML) OutputsAO2-0420 No.2 0÷20 or 4÷20mA Analog Outputs
6
41
42
DIN RANGE PANEL METERSDESCRIPTIONAvailable with moving iron or moving coil movements for a.c. or d.c. use, these DIN panel metershave been supplied worldwide andare recognised for their quality and value. Standard scales or customised dials can be offered.
• Manufactured to:DIN 43700, IEC51 and BS89.
• 48mm, 72mm and 96mm sizes.• a.c. or d.c. use.• Interchangeable dials (72mm & 96mm).• Rugged pivot and jewel movement.• Ammeters, Voltmeters, Frequency
Meters, Power Factor Indicators,Wattmeters, Elapsed Time Indicatorsand Maximum Demand Indicators.
• Optional red secondary pointer andterminal cover.
• Special customised dials.
Howard Butler Limited is one of the largestindependent UK manufacturers of panel metersand associated products.
With over 80 years experience in the industryHOBUT products have built a reputation forhigh quality and modern design at competitive prices.
ANALOGUE PANEL METERS • D IGITAL PANEL METERS • HOURS COUNTERS • SELECTOR SWITCHES • PROTECTION RELAYS • TRANSDUCERSSHUNTS • CURRENT TRANSFORMERS • CHARGER METERS • THERMAL CUTOUTS • MULT I -FUNCTION METERS
11840
43
DIN RANGE PANEL METERSMOVING IRON Types: D48SD, D72SD, D96SD.
Accuracy: Class 1.5 (Class 2.5-60A andabove).
AC ratings: 1A to 100A direct connected(D48SD - 40A max).1A or 5A CT operated.30V to 600V direct connected.
Burden: 0.7VA typical for 1A or 5A CToperated at 50Hz.1.2VA max up to 30A2.4VA max for 40A to 100A.6VA max for voltmeters up to 600V.
Frequency: Calibrated at 50Hz.Specify for frequencies 15Hz upto 400Hz
Scaling: Standard ammeter and voltmeterscales.(2x and 6x overload amme-ter scales available on request).
Damping: Heavily damped movements available.
MOVING COIL Types: D48MC, D72MC, D96MC.Accuracy: Class 1.5. DC ratings: 100µA to 50A direct connected
(D48MC - 40A max).4-20mA, 1mA or 20mAtransducer operated.50mV to 600V direct connected.50mV to 300mV shunt operated.
AC ratings: Rectifier types available for a.c.use (mean sensitivity).
DC burden: 80mV to 150mV volt drop fordirect connect ammeters 1mA(1000Ω/V) for voltmeters andshunt operated ammeters.
Non std.: Suppressed zero voltmeters andtrim potentiometer types available.
WATTMETER Type: D96WA.Accuracy: Class 1.5.AC ratings: 1A or 5A CT operated.
63.5V to 500V direct connected.Burden: Current<0.5VA
Voltage<2.0VA each circuit.
Working range: Current 0-120%
Voltage 75-125%.Frequency: Calibrated for 50Hz or 60Hz.Systems: WA1 Single phase.
Type: D96PF.Accuracy: Class 1.5 (±2 electrical degrees).AC ratings: 1A or 5A CT operated.
63.5V to 500V direct connected.Burden: Current<0.5VA
Voltage<2.0VA each circuit.
Working Current 20-150%range: Voltage 75-125%.Scaling: Cos ø 0.5 CAP -|- 0.5 IND.Frequency: Calibrated for 50Hz or 60HzSystems: PF2 3 phase 3 or 4 wire balanced
Enclosure: DIN 43700.Flame retardant: base material UL94V1,case & terminal cover material UL94V0.Scale marking DIN 43802Protection IP52: IP54 can be supplied.
Overload: CURRENT - 1.2 x rating for 2hrs.- 10 x rating for 5 secs.
VOLTAGE - 1.2 x rating for 2hrs.- 2 x rating for 5 secs.
Insulation test: 2kV 50Hz for 1min.
Temperature: Calibrated at 23°c.Suitable for use at -25°c to +40°c.
Available extras: Adjustable red secondary pointer.Terminal cover.Special scale.Polycarbonate window.6.4mm “Faston” terminal tag(voltmeters & ammeters to 5A).
Other DIN products: Our illustrations and technical specifications apply to
meters with 90° scale arcs.Instruments with 240° scale arcs are also available.
dims+0.6–0.0
dims+0.7–0.0
dims+0.8–0.0
4568
6892
92
45
DIN 48 can be slot mounted using the standard fixing clip.DIN 72 & DIN 96 can be supplied with special fixing clips for slot mounting.Slot dimensions available on request.
• Digital panel meters.• Current Transformers.• Shunts.• Power transducers.• Protection relays.• Battery charger indicators.• Thermal cut-outs.
New HOBUT products include:• Pro-Din panel meters.• 240° panel meters.• kWh meters.• Multi-function meters.• Protective current transformers.
Data sheets on the following HOBUT product ranges are available onrequest:
E
F
D
CBA
A
A B C D E FDIN48 (M4 screw clamps) 48 5 43 44.8 10 –Ammeters up to 5A & Voltmeters
DIN96 Watt-meter 96 5.5 123 90 13 –DIN96 Power Factor Indicator 96 5.5 123 90 13 –DIN96 Max. Demand Indicator 96 5.5 58 90 10 20(M4 screw clamps)DIN96 Combined M.D.I. 96 5.5 58 90 10 20(M4 screw clamps)Note: If terminal covers are fitted as an optional extra, add 23mm to dimension ‘C’ for DIN72 & DIN96 meters, and 25mm to dimension ‘C’ for DIN48 meters.
DIN 96 DIN 72 DIN 48
46
47
PRODIN RANGE PANEL METERS
PD72SD MOVING IRON - AC
PD72HZ FREQUENCY RANGES
PD72MC MOVING COIL - DC
Dimensions (mm)Specifications
Options
DESCRIPTION 72 x 72mm DIN sized panelmeter with a horizontal scaleand a round barrel.Manufactured to IEC51.
APPLICATION Used widely in the panel building industry, where a DINproduct with a horizontal scaleis required. Round barrel allowsstraightforward installation withoutspecial tools.
Our policy is one of continuous development and therefore specifications may change without notice.
Rating Burden Accuracy ClassScaled up to 40A direct connected 1.2VA max up to 30A, 2.4VA up to 40A 1.51A or 5A CT operated, scaled as necessary 0.7VA typically at 50Hz 1.5Scaled 30V to 600V, direct connected 6VA max 1.5
Rating Burden Accuracy Class45/65, 45/55 or 55/65 Hz for 110/230/380V direct connected 6mA at nominal voltage 1.5
Rating Burden Accuracy Class100µA to 40A direct connected up to 150mV 1.54/20mA, scaled as necessary up to 150mV 1.5Scaled up to 600V, direct connected 1mA (1000Ω/V) 1.550mV to 300mV shunt operated, scaled as necessary 1mA (1000Ω/V) 1.5
Flame retardant: Base - UL94V1, Case - UL94V0Protection: IP52 (front of panel)Scale marking: DIN 43802Overload (A): 1.2 x rating 2hrs / 10 x rating 5 secondsOverload (V): 1.2 x rating 2hrs / 2 x rating 5 secondsInsulation test: 2kV 50Hz for 1 minuteTemperature: Calibrated at 23°C, suitable for -25 to +40°CTerminals: M4 screw clamps supplied as standard
(above 5A, M6 studs are supplied)Panel mounting: U-clamp fixing or 2 pin fixing (57mm or 53mm)
• Special scales• M6 terminals, M3 studs • 6.4mm faston tags (up to 5A)• Terminal cover
Panel cut-out ø56
11840
48
R68 RANGE PANEL METERS
R68SD MOVING IRON - AC
R68MC MOVING COIL - DC
Dimensions (mm)Specifications
Options
DESCRIPTION Rectangular fronted, round barrelled, moving iron and moving coil panel meters for AC or DC use. Manufactured to IEC51 / BS89.
APPLICATION Used widely in the panel building, welding, and batterycharger industry, where a roundbarrelled instrument is requiredto fit into a standard 64mmdiameter panel cut-out.
Our policy is one of continuous development and therefore specifications may change without notice.
Rating Burden AccuracyScaled up to 100A direct connected 1.2VA max upto 30A, 2.4VA max 40-100A 2.5%1A or 5A CT operated, scaled as necessary 0.7VA typically at 50Hz 2.5%Scaled 30V to 600V, direct connected 6VA max 2.5%
Rating Burden AccuracyScaled 50µA to 50A direct connected 80mV to 150mV volt drop 1.5%50mV to 300mV shunt operated, scaled as necessary 1mA (1000Ω/V) 1.5%Scaled 50mV to 600V, direct connected 1mA (1000Ω/V) 1.5%
R68SD R68MCScale length 52mm 62mmMovement 90° 90°Fixing method U-clip U-clipFlame retardant Base UL94V1 Base UL94V1
Case UL94V0 Case UL94V0Protection(front of panel) IP52 IP52
82 29.5
58
10
68 63Dia
64
• Adjustable red secondary pointer• 6 x overload scale (R68SD) • Tropical finish• Special dials• Black or white dial mask• R68 available as power factor indicator, wattmeter,
frequency meter, details on request.
Panel cut-out
11840
49
50
51
52
53
AC VOLTAGE
TECHNICAL SPECIFICATION
INPUT
Rated value Un 57.8 <100 / 110 <600 V
Power consumption <1.5 VA (VA1, VA3)
<1 VA (VL1, VL3, VR1)
Working range 15-125% Un (VA1, VA3)
0-125% Un (VL1, VL3, VR1)
Rated Frequency 50 / 60 / 400 Hz
Frequency influence 0.005 % / Hz
Overload continuous 1.5 x Un
Overload for 1 sec. 4 x Un (VL1 VL3 VR1 )
2 x Un (VA1 VA3)
OUTPUT
Rated value mA 0-1/5/10/20mA (VA1, VA3)
Rated value mA 1/5/10/20 & 4-20mA (VR1)
Rated value mA 4-20mA (VL1)
Rated Value volts 0-5 / 10 V (VA1, VA3)
Rated value volts 0-5 / 10 & 1-5 V (VR1)
Rated value volts 1-5 V (VL1 VL3)
ADJUSTMENT
Zero No adjustment (VA1,VA3)
Zero ± 2% (VR1,VL1)
Span ± 10% (VA1,VA3,VR1,VL1,VL3)
AUXILIARY
A.C. Voltage 115 / 230 / 400 V
(± 25% / 45-65Hz / <2 VA)
D.C. Voltage 24 / 48 / 110 V (± 20% /
galvanically isolated / < 3 W)
Note M100-VA1 & VA3 are self
powered.
WEIGHT & CASE SIZE
M100-VA1 Approx. 0.3 kg. 55mm case
M100-VL1,VR1 Approx. 0.4 kg. 55mm case
M100-VA3 Approx. 0.6 kg. 100mm case
M100-VL3 Approx. 0.7 kg. 100mm case
ORDERING INFORMATION
Product Code Input In Output Aux Freq. OptionsM100-AL1 5A 4-20mA 230V 50Hz
OPTIONS
1. Non standard inputs / outputs only as far as technically
acceptable.
2. A.C. Auxiliary in range 57.7 to 450 volts
3. Calibration at nominal Hz 35.....450Hz
4. Calibration at temperature other than 23°C
7
The M100 series voltage transducers are designed to measure
A.C. Voltage in single and 3 phase system. They convert the
A.C. Signal to a D.C. Output that is directly proportional to
the input signal.
The M100-VA1 VA3 are self powered (i.e. no auxiliary
required) average sensing RMS calibrated voltage
transducers, mA and voltage outputs are available.
The M100-VL1 VL3 are average sensing RMS calibrated, live
zero voltage transducers. Auxiliary is required to provide
power so that 4mA output signal is present when the input is
zero.
The M100-VR1 is true RMS sensing RMS calibrated allowing
measurement of distorted waveforms of up to 9th harmonic
with a crest factor of 5. The VR1 is typically used in voltage
measurement where distorted waveform is common such as
thyristor drives.
The above units are used to measure voltage in energy
management systems, switchboards, generator and telemetery
controls. Isolation of 4kV is provided between the input and
output signal, allowing the ouput to be fed to conventional
analogue meters, digital meters, PLC, and computer systems.
M100-VL3 3 ph. aux powered ave. sensing RMS calibrated
54
AC VOLTAGE CONNECTION
DIAGRAMS
9
M100-VA1 / VS1 M100-VL1 / VR1 / VX1
M100-VA3 M100-VL3 / VX3
55
56
57
58
59
M850 MULTIFUNCTIONMETERSDESCRIPTION The new range of Hobut multifunction panel metersfeature 96 x 96mm sizes complete with unique blueLED screen, which can be seen in direct sunlight. Therange is easy to use, features user-programmable CT &VT ratios, and can be used on any single or 3 phasesystem with any input voltage without re-programming.
APPLICATION The range is a cost effective replacement for traditionalpanel meters and is suitable for low, medium and highvoltage control panels, gensets, building managementsystems, power management and more.
STANDARD FUNCTIONS:
Phase Voltage (V)
Phase to Neutral Voltage (V)
Phase Current (I)
Frequency (Hz)
Active Power (W)
Active Energy (kWh)
Reactive Power (VAr)
Apparent Power (VA)
Reactive Energy (VArh)
Power Factor (PF)
Instantaneous Amp Demand
Instantaneous Watt Demand
Instantaneous VA Demand
Maximum Amp Demand
Maximum Watt Demand
Maximum VA Demand
Neutral Current Measurement
RANGE ORDERING INFORMATION
PLUG-IN OPTIONS
All models feature thefollowing user-programmablefunctions:
• Current Transformer Ratio• Voltage Transformer Ratio• Baud Rate, Parity, Stops
• AC or DC AUX• 1A or 5A CT• Single or 3 phase system• Input voltage range 28-570V• RS485 address, 1-247• Security code access for
programming
PROGRAMMABLE FUNCTIONS
Suitable for any 1 or 3 phasesystem, AC aux 100-440V or DC aux 100-420V
Input 28/330V L-N48/570V L-L5A
STANDARD PRODUCT OPTIONAL EXTRAS
Pulsed Output
RS 485 Output
1A input (instead of 5A)
330mV Input(instead of 1A or 5A CT)
Order example: a standard product with RS 485 output is partnumber M850-MP1-RS
M850-MP1 P RS 1 MV
Both pulsed output(for Wh or VArh) andRS 485 output(Modbus protocol)are plug in optionswhich can besupplied with themultifunction meter.If purchasedseparately please useordering codes onright.
RS 485 Outputwhen ordered separately
use part RS485-M850
Pulsed Outputwhen ordered separately
use part PULSE-M850
60
L1
L2
L3
NL K
L3l k
L K
L2l k
L K
L1l k
L1L2L3NAUX UH
L+ N-
M850 MULTIFUNCTIONMETERS
ACCURACY Volts/Amps: 0.5% of readingFrequency: 0.1 HzActive Power: 1% of readingApparent Power:1% of readingPower Factor: 2% of rangeEnergy: IEC 1036 Class 1INPUT Rated Un: 28-330V LN, 48-570V L-LOverload: 800V continuousBurden: 0.5VA per phaseRated In: 0.5-6AOverload: 10 In for 1 secBurden: 0.5VA per phaseAuxiliary: 100-440V AC / 100-420V DC Frequency: 45/65HzDISPLAY Digits: 3 lines 9999Size: 14.2mm 7 segmentBrightness: user adjustableOUTPUT RELAY (Wh or VArh) Pulse output: SPST-NO (10 watt, 300VDC, 500mA)Pulse duration: programmable from 40msec-200msec
INSULATION Test Voltage: 3kV RMS 50Hz for 1 minute between case,
input and aux.1kV between case, input, aux, relay output & RS485 output.
Impulse test: EMC 5kV transient complies with IEC801/ EN55020 HF
Surge withstand: IEC801/EN55020 Ansi C37.90AInterference: EHF 2.5kV 1Mhz complying to IEC255-4Protection class II: Complying to IEC348 / BS4753 /
DIN57411 / VDESTANDARDS General: IEC688, BSEN60688, BS4889, IEC359EMC: BSEN61000-6-3:2007, BSEN61000-6-4:2007,Safety: IEC1010, BSEN601010ENVIRONMENT Working temp: 0-60ºCStorage temp: -40 to +85ºCRelative humidity: 0-95% non condensingShock: 30G in 2 planesMATERIAL Black polycarbonate case to UL94V0Weight: 0.35kg
SPECIFICATIONS
CONNECTION DIAGRAM
96
96
with plug inoption fitted
8219
61
92 (+0.8)
92 (+0.8)
Panel cut out
DIMENSIONS (mm)
Our policy is one of continuous development and therefore specifications may change without notice.
All current transformers are supplied as standard with 5A secondry. 1A secondry available by request.A range of accuracies are available from 0.2S to class 3, protection and class X.
62
127 SERIESTYPE CTH127L
H
W
Ø
D
H
W
Ø
D
Our policy is one of continuous development and therefore specifications may change without notice.
Busbars (mm) 16mm 21mm 25mm or 31mmAPERTURES APERTURES APERTURES
Dimensions (mm) H 80 79 90
W 75 105 140
D 60 38 38
DIN Rail Mount – OPTION OPTION – –
Foot Mount l l l – OPTION
Terminal Cover l l l – –
60A 100A 250A 100A 1A
160A 250A 600A 6000A 6000A
RING TYPECAST RESINSERIES
All current transformers are supplied as standard with 5Asecondry. 1A secondry available by request.
A range of accuracies are available from 0.2S to class 3,protection and class X.
MANUFACTUREDTO ORDER
ANY SIZEANY BUSBAR
MANUFACTUREDTO ORDER
ANY SIZEANY BUSBAR
QualityHOBUT products are manufactured to stringentQuality Control techniques and the company isapproved to ISO 9001 certification.
3 PHASETYPE CT140FTYPE CT105FTYPE CT75
TYPE CTH127M
NEW
CUSTOMPRODUCTSHoward Butler Ltd.manufacture special CTsfor various applicationsthroughout the world. We manufacture highaccuracy CTs such as 0.2S& 0.5S, protection CTssuch as 5P10 & 5P20,Class X CTs and more. We can provide a solutionfor every low voltage CT application.
63
64
65
66
67
Circuit breakers PR 60 J
A 15
Technical data PR 60 J – DCStandards EN 60 898-1, EN 60 947-2Number of poles 1, 2Instantaneous tripping characteristics C - according to EN 60 898-1, M - according to EN 60 947-2Rated current In A 0,2 - 63Rated voltage Un V 220; 440Short-circuit breaking capacity kA 4,5Electrical endurance switching cycles 4 000Mechanical endurance switching cycles 100 000Cross sectional area of inlet conductors mm2 1,5 - 25 for Cu conductors
2,5 - 25 for Al conductorsMounting on rail DIN 35x7,5 EN 60 715
on boardDegree of protection IP 20
IP 40 from the front panelAmbient air temperature °C from -25 to +55Working positions optionalResistance against vibrations 3g(8-50Hz)Approved ESS, ESČAccesories auxiliary and signal contacts - PKJ, 2PKJ,PKJ+SKJ
SPECIAL TERMINALS Feed-through terminals RK | Fused
terminals SIK/SK, in high-temp.
design
Page 206
Test adapters
Page 318
labelling adapters
Page 314
Test plugs
Page 317
Fuse holders
Page 322
85
Shield-connection clip SAB |
SSAB
Page 230
EX terminal blocks ATEX
Page 242
Marker holders for terminal
blocks and end stops
Page 276
Cross-connections
(Potential distribution)
Page 282
11
Covers
Page 310
End plates | Visual separation
Page 278
Terminal blocks for temperature
measuring circuits TSK
Page 210
Screw-distributor blocks SVB
Page 218
Terminal blocks with spade
connection FF/SF
Page 212
Pressure-spring junction
terminals D
Page 222
Fuse cartridges
Page 324
Specific accessories
Page 326
CE electrical cabinet
socket outlet
Page 330
86
87
AUXILIARY RELAYS FOR TRIPPING APPLICATIONS
88
Auxiliary relays | Tripping applications
ARTECHE offers a wide range of relays specially designed to be used in circuit breaker tripping applications.
› Interface between protection and control equipments and HV and/or MV circuit breakers, eliminating risks in case of internal failure of the circuit breaker.
› Trip contacts multiplication, to operate directly on the circuit breaker and transmit the corresponding alarms in a minimum time.
› Trip and lock-out, with electric or hand reset to avoid accidental closing of circuit breakers associated to power transformers, generators or machines.
› The surveillance of the trip circuit, guarantees it is in perfect conditions to allow the trip when it is needed.
ANSWER FOR ANY TRIPPING APPLICATION
In addition to the specific applicable standards, ARTECHE auxiliary relays are designed based on the fulfilment of the following standards:
› IEC 60255: Electrical relays. Measuring relays and protection
equipment.
› IEC 61812: Specified time relays for industrial use.
› IEC 61812: Relés de tiempo especificado para aplicaciones
industriales.
› IEC 60947: Low-voltage switchgear and controlgear.
› IEC 61000: Electromagnetic compatibility.
TECHNICAL STANDARDS
GENERAL STANDARDS
89
usAuxiliary relays | Tripping applications
Some of the general characteristics of the ARTECHE trip relays are:
In addition, the different number of alternatives that are offered when the equipment is selected, both technically (increase of the breaking capacity by serial contacts or by the magnetic blow out, high speed operation of the output contacts, possibility of adding different options to the relay) and in the assembly method (front, rear or flush mounted sockets, with screws or fastons) must be considered.
› High isolation level between input and output circuit, which guarantees that a problem in the circuit breaker will not cause irreparable damages on the protection system.
› Fast operating times, down to 3 ms, minimizing the impact on the total trip time.
› High breaking capacity, which allows direct operation on highly inductive circuits.
› Sturdy design, which ensures high reliability.
› Wide range of auxiliary voltage (Vdc and Vac).
› Self-cleaning of the contacts.
› Security contacts according to EN 50205.
› Easy installation (plug-in relays with diff erent installation possibilities).
› Designed to work in permanent service, even at high temperature for the whole voltage range.
› Possibility to work in environments with relative humidity of 100%.
› Seismic characteristics, allowing their use in installations which can be subject to vibrations, as for example in power stations or in regions with high risk of seism.
› High protection degree (IP40), with transparent cover, making them appropriate for tropical and saline environments.
› Fulfi lment of the most demanding standards: IEC, EN, IEEE, CE and UL mark.
› No maintenance needed.
GENERALCHARACTERISTICS
90
Auxiliary relays | Tripping applications
RANGE OF PRODUCTS
Instantaneous trip relays, whose contacts change instantaneously from the rest position to the working position when the coil is energized. The contacts return to the rest position when the coil is no longer energized.
This range includes relays with 2, 4 and 8 contacts, with operating times from 3 ms to 8 ms, depending on the model.
All the relays include a diode in parallel with the coil (see auxiliary relays with overvoltage protection characteristic) and comply with the sock and vibration standards, related to the relays with seismic characteristics.
Trip relays with 2 stable positions for the output contacts. Depending on which coil is energized, the contacts will change from one position to the other. The design of the ARTECHE relays has no consumption in permanence, and prevents both coils from being energized simultaneously.
This range includes relays with 3, 4 and 8 contacts, with operating times below 10 ms, depending on the model, and possibility of manual reset. The position change is made with 2 sets of coils with separated entrances, in BF-3 and BJ-8, and with breaking-flame contacts for each set of coils.
For single phase or three phase circuit breakers. Through a small supervision current the whole circuit is supervised, in both positions of the circuit breaker (opened or closed).
The correct state of the circuit is showed with a green LED on the front plate of the relay. The output contacts change its position if the relay detects a failure in the continuity of the circuit.
Auxiliary relay with four changeover contacts, aimed to supervise the failure of trip supply. Connecting the relay across the trip circuit supply, the equipment is normally energized. Faults will occur when the trip voltage is lost, so the relay drops off in those cases, providing the related signs and alarms.In order to avoid faulty alarms due to instantaneous supply voltage dips, the drop off time of the relay is delayed over 100 ms so those non-permanent failures of trip supply would not be considered.
TRIP RELAYS
TRIP AND LOCKOUT RELAYS
TRIP CIRCUIT SUPERVISION RELAYS
AUXILIARY SUPPLY CIRCUIT SUPERVISION RELAYS
91
c'i\lus (Auxiliary relays | Tripping applications
TRIP RELAYS (I)Model RD-2R RD-2XR RF-4R RF-4XR
Applications Intended for tripping applications where high demanding requirements in operating time (with tripping time from 8ms to 3 ms) and breaking capacity are needed,
that is the case of tripping HV and MV circuit breakers.
High burden confi guration not available See page 15 for technical details
Construction characteristics
Contacts no. 2 Changeover 4 Changeover
Connections
OptionsWith 0P options • LED included • Diode in parallel with the coil included
Weight (g) 125 250
Dimensions (mm) 22,5 x 50,4 x 72 42,5 x 50,4 x 72 (F short Type)
(1) Other voltage upon request (2) Guarantee data for relays just manufactured (3) Ask for higher altitudes
Model RUT-4
Applications Supervise only the auxiliary supply circuit of the protection equipments,
avoiding false alarms due to short-time drop of supply
Construction characteristics
Timing Contacts no. 4 Changeover
Connections
Options Options are not available
Weight (g) 250
Dimensions (mm) 42,5 x 50,4 x 96,6 (F short Type)
Coil characteristics
Standard voltages (1) 24, 48, 72, 110, 125, 220 Vdc
Voltage range +10% -20% UN
Pick-up voltage See pick-up release voltage-temperature curves for standard relays
Release voltage
Consumptions in permanence 3,9 W
Operating time
Pick-up time <20 ms
Drop-out time To minimum voltage
Maximum>100 ms<400 ms
Contacts
Contact material AgNi
Contacts resistance (2) ≤30 mΩ
Distance between contacts 1,8 mm
Permanent current 10 A
Instantaneous current 80 A during 200 ms / 200 A during 10 ms
Max. making capacity 40 A / 0,5 s / 110 Vdc
Breaking capacity See breaking capacity curves (Contact Confi guration Type A)
Max. breaking capacity See value for 50.000 operations
Umax
opened contact 250 Vdc / 400 Vac
Performance data
Mechanical endurance 107 operations
Operating temperature -10ºC +55ºC
Storage temperature -30ºC +70ºC
Max. operating humidity 93% / +40ºC
Operating altitude(3) <2000 m
AUXILIARY SUPPLY SUPERVISION RELAYS
11
3
(-)(-) 1
(+)(+) 2
4
5
6
12
13
14
7
8
9
10
98
Auxiliary relays | Tripping applications
HIGH / LOW BURDEN CONFIGURATION (HIGH SPEED TRIPPING RELAYS ONLY)
The standard high speed tripping relays are manufactured with a low burden configuration, considering that the initiating contact is placed close to the tripping relay.
However, and in order to avoid unwanted trip relay operation due to pickup or transients, particularly if the relay operating coil is connected to extensive wiring, ARTECHE tripping relays could be manufactured with a high burden configuration, complying with ESI 48-4 international standard, as EB2 class relays. These EB2 class relays are suitable for use in high security circuit breaker tripping circuits, increasing their immunity to capacitance discharge currents.
Instantaneous relays (self reset relays): same consumption as low burden configuration
Latching relays (electric and hand&electric reset): See table below
For relays with rated voltage up to and including the 125 V, the relays will withstand, without operating, a discharge into their operate circuits of a 10μF capacitor charged to 120% of the higher rated voltage for the relay.
For relays with rated voltage of 220 V, the relays will withstand, without operating a discharge into their operate circuits of a 10μF capacitor charged to 100% of the higher rated voltage for the relay, i.e 242 V.
Specifications:
ESI 48-4 EB1: 1983 Low BurdenESI 48-4 EB2: 1983 High Burden
HIGH BURDEN RELAYS CONSUMPTIONS
Electrical reset and hand and electrical reset relays
Standard Voltage 220 Vdc 125 Vdc 24 Vdc
Consumption (only in commutation) < 150 W (peak) < 100 W (peak) < 75 W (peak)
99
OGIPRO
Company
First National Pakistan155-A Sarfraz Rafiqui RoadLahore Cantt.Pakistan
Our sign JE Peggau, 01st September 2013
Authorized Distribution Letter
Dear Sirs,
GIPRO GmbH in Peggau Austria hereby confirms that First National Pakistan, 155-ASarfraz Rafiqui Road, Lahore Cantt., Pakistan is authorized to represent and to sellGIPRO products in the area of PAKISTAN.
The products are:In- and Outdoor epoxy insulators for several different applicationsSurge arrestors for several needs
TYPE TEST REPORTS relating toVARISlLTMHE polymer housectsurge arresters & associated accessories
I
TYPE TESTS REFERENCE SAMPLES TEST REPORT ADDITIONALPERFORMED STANDARD TESTED Reference Dete ' Langutf!!1_6 INFORMATION
, Housings rated CESI12 kV, 24 kVAT-A1f025452 September 3, 2001 English
Insulation withstand tests. &.36kVon the housings lEG 600994- Housing rated CESI
,
& § 10..8.2 1B kV &. type S3 AT ·A1/025961 September 5, 2001 English ,
the insu'latin9 bracketI insulating bracket .I
,
Housing rated CESI August 10, 2006 English, 42 kV A6/02i821 I
Technical dooumentSteep, lightning TPF ST HE 041 e rev. 02 Iand switching lEG 60099-4 6 kV CBSI , (January 4, 2010, English)currenl impulse § 10.8.3 prorated sections AT-AOJ041526 January 25, 2001 English &. Voltage vs current characteristic curve :
residual voltage tests VI 8997 01 XX (E rev. 03II (January "I, 2010, Engllsh)
HE18S0 C.ESI June 7, 2001 EnglishLong duration current lEG 60099-4 surge arresters AT-A1J014923 I
I impulse withstand test §10.8..4 6 kV 81D2 CESI •'September 28,2005 English ,
, prorated sections A5f0465386 kV CESI
January 25, 2001 English I
_prorated sections AT-AO!041527High Gurrent impulse IEC 60099-4 HE 18 80 CBS'I I i
I June 7, 2001 EngUsh, operating duty test § 10.8.5 surge arresters AT -A 1/014924
6 kV S1D2 CESI December 14, 2005 English,
prorated sections A5/055428
Date: January g, g013 Page: 1 J 2Refer.ence : TPF ST HE 01/ E rev. 19,
106
TYPE TESTS REFERENCE SAMPLES TEST REPORT ADDITIONAL IPERFORMED STANDARD TESTED Reference Date Language INFORMATION
Voltage vs time IEC 60099-4 HE range Curve UT 8997 01 XX I E rev. 02characteristic curve § 6.10 (January 4,2010, English)
lEG 60099-4 CESI September 14,2011 EnglishTest carried out
§ 8.6.2.1 8102744'9 in series with a 6 kV 53D2 section
Tests on lEG 60099-4 Type S3D2 CESI September 14,2011 English Test carried out
disconnector _§_ 8.6.2.2 disconnector 81027448 in series with a 6 kV S302 section
lEe 60099-4 CESICurrent vs time characteristic curve
September 13, 2011 English CT 8997 09 9X I E rev. 02§ 8.6.3 B1027905 J (September 14, 20·11, English)
Tests on lEG 60099-4 Type IF CESICurrent vs time characteristic curve
September 11, 1997 English CT 899509 04 I E rev. 08fault indicator § 8.6.4 fault indicator MP·97/026984 (January 4,2010, English)
Short circuit tests IEC 60099-4 HE 24 CESIJune 25, 2008 English§ 10.B.7 surge arresters A8018577
Partial discharge test lEG 60099-4 HE 36 CESI December 22,2000 Engllish§ 10.8.8 surge arresters AT·AOJ042489
Bending moment test lEG 60099-4 HE 36 TRIDELTA I seas November 15, 2012 English§ 10.8.13 surge arresters TR.e 12018BMIEC 60099-4
HE 36 CESI t§ 10.8.14.2.1 December 18, 2002 English(1000 h test) surge arrester AT ·A2J032924
Weather ageing testlEG 60099-4§ 10.8..14.2.2 HE 24 CESI March 27, 2003 English(5000 h test)_ surge arrester AT ·A3/007530
b :reference Is.m_ to the Iatast version of lEe 60099-4 standard, ~ edition 22 published in May 2009
107
Type HE 12Rated voltage Ur in kV rms 12
Rated frequency Hz 50 / 60Continuous operating voltage Uc in kV rms 10,2
Nominal discharge current In in kA with 8/20 impulse 10Line discharge class Class 1
High current impulse withstand kA with 4/10 impulse (x 2) 100Maximum leakage current under Uc at 20 °C resistive component in mA peak 1,0
capacitive component in mA peak 0,5total current in mA rms 1,0
nergy absorption capability with 8/20 impulse kJ / kV of Ur 4,1kJ / kV of Uc 4,8
Long duration current impulse withstand A with 2000 µs impulse (x 18 + 1) 300ergy absorption capability with 2 ms impulse kJ / kV of Ur 2,0
kJ / kV of Uc 2,4kV peak at 2.5 kA 8/20 29,0
Maximum lightning residual voltage kV peak at 5 kA 8/20 30,8kV peak at 10 kA 8/20 32,8kV peak at 20 kA 8/20 36,2kV peak at 40 kA 8/20 41,2
Maximum switching residual voltage kV peak at 125 A 30/80 24,6kV peak at 500 A 30/80 26,1kV peak at 1 kA 30/80 27,1kV peak at 5 kA 1/2.5 32,3
mum steep current impulse residual voltage kV peak at 10 kA 1/2.5 35,4Temporary overvoltage capability in kV rms 1 s without prior duty 15,5
1 s with prior duty 14,01 s with maximum prior duty 13,5
10 s without prior duty 14,810 s with prior duty 13,3
10 s with maximum prior duty 12,9Minimum reference voltage at 20 °C Iref in mA peak AC 1
Uref in kV peak/V2 11,6Short circuit current withstand kA during 0.2 s 20
A during 1.0 s 600Axial partial discharge level pC under 1.05*Uc < 10
Mechanical strength specified short-term load SSL in N.m 125specified long-term load SLL in N.m 100
dynamic pull loading in N 750static pull loading in N 500
torsion in N.m 30Line terminal maximum conductor diameter in mm 18
permissible materials Cu / Al / SteelEarth terminal maximum conductor diameter in mm s/ option
permissible materials Cu / Al / SteelInsulation withstand power frequency 1 min dry in kV rms 42
power frequency 1 min wet in kV rms 381.2/50 lightning impulse dry in kV peak 95
Physical characteristics of the housing material siliconenb of weathersheds ( small / large ) 4 / 5
weathersheds diameter in mm 74 / 104Nominal creepage distance mm 480