Top Banner
PROPOSAL Proposal Submitted To: Date: Address: ATTN: City, ST, ZIP Phone No: Job Name: Fax No.: Job Location: X Furnish & Install Tax Included Furnish & Deliver No Tax Included CPU X ALL ELECTRICAL X PAINTING X OTHER (DESCRIBE) FRAMING QTY AMOUNT 3 3 3 3 3 3 $43,466.00 Payment to made as follows: NET 30 DAYS Signature Date EXCLUSIONS: 330-384-4663 strikes, accidents or delays beyond our control. Owner to carry fire, tornado and other necessary insurance. Our workers are fully covered by Workman's Compensation Insurance. TOTAL PRICE INSTALLED - All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any alteration or any deviation from above AMARR MODEL 2700 COMMERCIAL POLYURETHANE INSULATED SECTIONAL DOORS - QUOTE IS BASED ON LEVEL APPROACH - INCLINE OR DECLINE APPROACH WILL specifications involving extra costs will be executed only upon written orders, and will become an extra charge over and above the estimate. All agreements contingent upon AFFECT PRICING AND LEAD TIME. 8'2" X 10'0" - WHITE - MAXIMUM HI-LIFT TRACK - WEATHERSTRIP - TWO WINDOWS - TRAFFIC LIGHT SIGNALS AND DRIVER WARNING SIGNS - MANARAS MODEL MH COMMERCIAL JACKSHAFT OPERATOR - 1/2 HORSEPOWER - PIONEER MODEL PFV40 HEAD CURTAIN STYLE DOCK SEALS - 40 OZ. VINYLS - PIONEER MODEL EVR650 AUTOMATIC TRUCK RESTRAINT - AUTOMATIC PUSH PIONEER DOCK LIGHTS - SAFETY YELLOW - CHAIN HOIST - MECHANICAL BRAKE - 3-BUTTON STATION - PIONERR MODEL HP7840 HYDRAULIC PIT LEVELERS - 7' X 8' - 40,000 LB. CAPACITY - BUTTON OPERATION - IN EXCESS OF 50,000 LBS. RESTRAINING FORCE - OPERATING RANGE OF 12" TO 30" - EVR COMMUNICATION SYSTEM INCLUDES INSIDE / OUTSIDE 1 HP MOTOR & PUMP ASSEMBLY - TWO MOLDED BUMPERS - 16" LIP - WE HEREBY SUBMIT/ESTIMATE THE FOLLOWING: FIRST ENERGY 10/13/2009 JEFFREY JOHANSEN TRANSFORMER WAREHOUSE 4295 E. 146TH STREET ACCEPTANCE OF PROPOSAL - The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. 10/13/2009 John Thompson, President John Thompson Date OMEGA Door Company 1223 GIBSON ST. YOUNGSTOWN, OH 44502 Phone: (330) 747-1365 Fax: (330) 747-3149
25
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: First Energy Quote

PROPOSALProposal Submitted To: Date:

Address: ATTN:

City, ST, ZIP Phone No:

Job Name: Fax No.:

Job Location:

X Furnish & Install Tax Included

Furnish & Deliver No Tax Included

CPU

X ALL ELECTRICAL

X PAINTING

X OTHER (DESCRIBE) FRAMING

QTY AMOUNT

3

3

3

3

3

3

$43,466.00

Payment to made as follows: NET 30 DAYS

Signature Date

EXCLUSIONS:

330-384-4663

strikes, accidents or delays beyond our control. Owner to carry fire, tornado and other necessary insurance. Our workers are fully covered by Workman's Compensation Insurance.

TOTAL PRICE INSTALLED -

All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any alteration or any deviation from above

AMARR MODEL 2700 COMMERCIAL POLYURETHANE INSULATED SECTIONAL DOORS -

QUOTE IS BASED ON LEVEL APPROACH - INCLINE OR DECLINE APPROACH WILL

specifications involving extra costs will be executed only upon written orders, and will become an extra charge over and above the estimate. All agreements contingent upon

AFFECT PRICING AND LEAD TIME.

8'2" X 10'0" - WHITE - MAXIMUM HI-LIFT TRACK - WEATHERSTRIP - TWO WINDOWS -

TRAFFIC LIGHT SIGNALS AND DRIVER WARNING SIGNS -

MANARAS MODEL MH COMMERCIAL JACKSHAFT OPERATOR - 1/2 HORSEPOWER -

PIONEER MODEL PFV40 HEAD CURTAIN STYLE DOCK SEALS - 40 OZ. VINYLS -

PIONEER MODEL EVR650 AUTOMATIC TRUCK RESTRAINT - AUTOMATIC PUSH

PIONEER DOCK LIGHTS - SAFETY YELLOW -

CHAIN HOIST - MECHANICAL BRAKE - 3-BUTTON STATION -

PIONERR MODEL HP7840 HYDRAULIC PIT LEVELERS - 7' X 8' - 40,000 LB. CAPACITY -

BUTTON OPERATION - IN EXCESS OF 50,000 LBS. RESTRAINING FORCE - OPERATING

RANGE OF 12" TO 30" - EVR COMMUNICATION SYSTEM INCLUDES INSIDE / OUTSIDE

1 HP MOTOR & PUMP ASSEMBLY - TWO MOLDED BUMPERS - 16" LIP -

WE HEREBY SUBMIT/ESTIMATE THE FOLLOWING:

FIRST ENERGY 10/13/2009

JEFFREY JOHANSEN

TRANSFORMER WAREHOUSE

4295 E. 146TH STREET

ACCEPTANCE OF PROPOSAL - The above prices, specifications and conditions are satisfactory and are hereby accepted.You are authorized to do the work as specified. Payment will be made as outlined above.

10/13/2009John Thompson, President

John ThompsonDate

OMEGADoor Company

1223 GIBSON ST.YOUNGSTOWN, OH 44502

Phone: (330) 747-1365 Fax: (330) 747-3149

Page 2: First Energy Quote

M O D E L 2 7 0 0SECTIONAL DOORS

Page 3: First Energy Quote

W A R R A N T I E S

C O L O R S

26" x 13" DOUBLE INSULATED ACRYLIC WINDOWS WITH BLACK FRAMEWHITE FRAME AVAILABLE (SPECIAL ORDER)

24" x 6" DOUBLE INSULATED ACRYLIC WINDOWS WITH BLACK FRAMEWHITE FRAME AVAILABLE (SPECIAL ORDER)

W I N D O W O P T I O N S

RIBBED PANEL WITH STUCCO EMBOSSMENT

P A N E L

Model 2700Heavy-duty 2" Foamed-in-Place Door

The Model 2700 is Amarr’s top-of-the-line high R-Value door

designed exclusively for the Commercial and Industrial

sectional overhead door market. It is constructed using

foamed-in-place polyurethane insulation which creates a strong

monolithic panel that is energy efficient.

Each Model 2700 is secured with standard 14-gauge, galvanized

steel hinges. The interior skin of each section has two continuous

horizontal 20-gauge reinforcing strips. The section joint is

thermally broken and chemically bonded with a pressure-sensitive

adhesive sealant. An EPDM rubber weather seal further enhances

the performance of the joint.

Construction

TRIPLE-LAYERSteel + Insulation + Steel

• 10-year Limited Warranty on the paint and finish

• 1-year Limited Warranty on hardware

• See your dealer or visit amarr.com for complete warranty details

Steel Interior

Polyurethane Insulation

Bottom Weather Seal

Steel Exterior

COMMERCIAL WHITE BROWN

OPTIONAL FULL-VIEW PANEL

24" X 12" INSULATED GLASS

FOR PRODUCT BINDER:1.800.503.3667

165 Carriage Court

Winston-Salem, NC 27105

800.503.DOOR

www.amarr.com

FOR TECHNICAL QUESTIONS: 1.877.512.6277

Actual paint colors may vary from samples shown.

©2009 Amarr Garage Doors Printed in USA Form #6210609/00M/SWDAmarr Garage Doors are the subject of one or more

pending patents and/or U.S.A. or foreign patents.Amarr reserves the right to change specifications and designs without notice and without incurring obligations.

Amarr steel doors arrive pre-painted; for custom colors, exterior latex

paint must be used. Visit amarr.com for instructions on painting.

Track: All Amarr Doors are available with both

2" or 3" track in Standard Lift, High Lift, Vertical Lift,

Low Headroom, and Follow-the-Roof Pitch. Custom track

configurations are also available. For drawings and more

information, please visit our website at www.amarr.com.

Hardware: Amarr hardware includes minimum

14-gauge galvanized steel hinges and 13-gauge

galvanized steel track brackets. All rollers have

minimum 10-ball bearings.

Springs: Torsion springs are oil tempered, helical

wound and custom computed for each door for a

minimum 10,000 cycle life. Optional springs are

available up to 100,000 cycle life.

R-Value*

15.67

Amarr is a registered trademark of The Amarr Company, North Carolina, U.S.A.

*Calculated door section R-value is in accordance with DASMA TDS-163.

Page 4: First Energy Quote

SECTION 08360

SECTIONAL OVERHEAD DOORS

ART 1 GENEP RAL

.1 S1

ECTION INCLUDES

A. Insulated Steel Doors

B. Track and Framing

.2 R1

ELATED SECTIONS

A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

B. Section 05500 – Metal Fabrications: - Steel framed door openings.

C. Section 06100 – Rough Carpentry: Wood framing and blocking for door opening.

D. Section 07900 - Joint Sealers: Perimeter sealant and backup materials.

E. Section 08710 - Door Hardware: Cylinder locks.

.3 R1

EFERENCES

A. ASTM A 653/A 653M – Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.

B. ASTM B 209/209M – Specification for Aluminum and Aluminum-Alloy Sheet and Plate.

C. ASTM B 221/221M – Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods,

Wire, Profiles and Tubes.

D. ANSI/DASMA 102-1996. .4 S1

UBMITTALS

A. Submit under provisions of Section 01300.

B. duct Data: duct to be used, including: Pro Manufacturer's data sheets on each pro1. Preparation instructions and recommendations.

08360-1

Page 5: First Energy Quote

2. Storage and handling requirements and recommendations.

4. Operation and maintenance data.

nnection details, anchorage spacing, hardware locations, and installation details.

of color chips representing manufacturer's full range of available colors and patterns.

um size 6 inches (150 mm) square, representing actual product, color, and patterns.

.5 WIND PERFORMANCE REQUIREMENTS

d negative wind loads as calculated in accordance with applicable governing building codes.

.6 QUALITY ASSURANCE

pes of doors specified in this section with minimum five years documented experience.

by qualified dealer in accordance with the manufacturer’s installation instructions.

.7 DELIVERY, STORAGE, AND HANDLING

A. Store products in manufacturer's unopened packaging until ready for installation.

.8 PROJECT CONDITIONS

its ll products under

environmental conditions outside manufacturer's absolute limits.

A. Delamination: 5-year warranty against delamination.

ART 2 PRODUCTS

.1 MANUFACTURERS

A. (800) 503-3667. Fax: (336) 251-1851. Email: [email protected]

3. Installation methods.

C. Shop Drawings: Include opening dimensions and required tolerances, co

D. Selection Samples: For each finish product specified, two complete sets

E. Verification Samples: For each finish product specified, two samples, minim

1

A. Design doors to withstand positive an

1

A. Manufacturer Qualifications: Company specializing in manufacturing the ty

B. Installer Qualifications: Installation to be

1

1

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limrecommended by manufacturer for optimum results. Do not insta

1.9 WARRANTY

P 2

Acceptable Manufacturer: Amarr Garage Doors; 165 Carriage Court, Winston-Salem, NC27105. ASD. Tel: www.amrr.com.

B. Substitutions: Not permitted.

ts for substitutions will be considered in accordance with provisions of Section 01600.

.2 OVERHEAD DOORS - GENERAL

counterbalance mechanisms and hardware to suit the opening and headroom available.

C. Reques

2

A. Provide each door with door sections, brackets, tracks,

08360-2

Page 6: First Energy Quote

B. Hardware:

1. Minimum of 14 gauge galvanized steel hinges and 13 gauge galvanized steel track

end stile locking device provided with spring-loaded bolt for inside operation

mm) and wider provided with double end hinges and stiles and long stem rollers.

l, inclined using adjustable

ed with 13 gauge oor size and weight.

d.

. 6. Provide low headroom tracks as indicated.

us

um ith ANSI/DASMA 102-1996 as follows:

les.

4. High Cycle Spring: 100,000 cycles.

alvanized steel step plate/lift handle provided on inside and outside of bottom section.

adlock. 1. Lock: 5 pin cylinder lock interior lock bar and outside key.

stripping: Full length dual contact EPDM rubber bottom seal attached to bottom section.

H. Weather stripping: Perimeter seal for header and jambs.

I. Mounting: Continuous reverse angle mounting for steel jambs.

J. Mounting: Bracket mounting for wood jambs.

K. Exhaust port: Installed in bottom sections. Connecting tube from vehicles by others.

.3 INSULATED STEEL DOORS

rethane insulated door.

ections

brackets. 2. Rollers have 10 ball bearings with casehardened inner and outer races. 3. Sliding

only. 4. Doors 16 feet 4 inches (5102

C. Tracks: 2 inches (51 mm) or 3 inches (76 mm) as required.

1. Vertical track 17 or 19-gauge minimum galvanized steebrackets to assure weather tight closure at the jambs.

2. Horizontal tracks 16-gauge minimum galvanized steel, reinforcgalvanized steel angles as required by d

3. Provide vertical lift tracks as indicate4. Provide high lift tracks as indicated. 5. Provide follow roof slope tracks as indicated

D. Spring Counterbalance: Torsion springs for door counter-balance mounted on a continuo

cross header shaft. Springs to be oil tempered, helical wound and custom computed for each door. Cable drums to be die cast aluminum. Galvanized lift cable to provide minimsafety factor of five to one. Springs to comply w1. Standard Cycle Spring: 10,000 cyc2. High Cycle Spring: 25,000 cycles. 3. High Cycle Spring: 50,000 cycles.

E. Handle: G

F. Lock: Standard interior sliding end stile lock with hole to receive p

G. Weather

2

A. Model 2700 Commercial 2 inches (51 mm) polyu1. Door Size: As indicated on the Drawings. 2. Door Sections: 2 inches (51 mm) thick, sandwich construction consisting of rolled

formed, commercial quality, 27 gauge exterior and interior steel skins, stucco embossed, and ribbed for added strength. Door to have tongue and groove joint system with EPDM thermal break and weather strip between section joints. Sto be insulated with CFC free polyurethane, foamed in place by means of a continuous process. Calculated door section R-value of 15.67 is in accordance with

08360-3

Page 7: First Energy Quote

m of section to provide

e metal, a 0.2 mil baked on prime coat and an p coat.

Lites: 24 by 6 inches (610 by 152 mm) double insulated acrylic with Black

Lites: 26 by 13 inches (635 by 330 mm) double insulated acrylic with Black

ieces of 1/8 inch (3.2

01-R1 atin anodized or white electrostatic alloy baked on polycron number 3.

.4 FABRICATION

m size: Model 2700 24 feet 2 inches wide by 16 feet 1 inch high

flection of no more than 1/120 of the spanned width when in the open position.

ART 3 EXECUTION

.1 EXAMINATION

A. Do not begin installation until substrates have been properly prepared.

e ready to receive work and opening dimensions and tolerances are within specified limits.

.2 PREPARATION

A. Clean surfaces thoroughly prior to installation.

re opening to permit correct installation of door unit to perimeter air and vapor barrier seal.

.3 INSTALLATION

with manufacturer's instructions. Doors to be interior face mounted on a prepared surface.

B. Anchor assembly to wall construction and building framing without distortion.

acks suspended from structure. Secure tracks to structural members or solid backing only.

D. Fit and align door assembly, tracks and operating hardware.

E. Install perimeter weatherstripping.

mounting of full hinges. End stiles to be 19 gauge standard. 3. Finish: Door exterior and interior pre-painted steel consisting of a hot dipped

galvanized coating applied to the bas0.8 mil baked on polyester toa. Exterior Color: White. b. Exterior Color: Brown.

1. Window Frame.

2. Window Frame.

3. Thermal Windows/Insulated Glass: 24 by 12 inches (610 by 305 mm) Molded plastic frame with insulated glass. Insulated glass unit to consist of two pmm) thick clear glass with a 7/8 inch (22 mm) aluminum spacer.

4. Aluminum Fullview Section: Single or dual glazing. Finished with mill finish of 2clear s

2

A. Insulated Steel Doors. 1. Standard maximu

(7.4m by 4.9m). a. Galvanized struts (truss bars): Provide on all doors 12 feet 4 inches (3.8 m) and

wider to prevent de

P 3

B. Verify wall openings ar

3

B. Prepa

3

A. Install in accordance

C. Securely brace door tr

08360-4

Page 8: First Energy Quote

08360-5

F. Adjust door assembly to smooth operation and in full contact with weatherstripping.

.4 CLEANING

A. Clean doors, frames and glass.

G. Remove labels and visible markings.

.5 PROTECTION

A. Protect installed products until completion of project.

B. Touch-up, repair or replace damaged products before Substantial Completion.

END OF SECTION

3

3

Page 9: First Energy Quote
Page 10: First Energy Quote
Page 11: First Energy Quote

Door Height

21" Bottom

21" Intermediate

24" Bottom

24" Intermediate

7'0" 1 37'3" 3 17'6" 2 1 17'9" 1 1 28'0" 48'3"8'6"8'9" 1 49'0" 4 19'3" 3 1 19'6" 2 1 29'9" 1 1 310'0" 1 410'3"10'6" 1 510'9" 5 111'0" 4 1 111'3" 3 1 211'6" 2 1 311'9" 1 1 412'0" 1 512'3" 1 612'6" 6 112'9" 5 1 113'0" 4 1 213'3" 3 1 313'6" 2 1 413'9" 1 1 514'0" 1 614'0" 1 714'3" 7 114'6" 6 1 114'9" 5 1 215'0" 4 1 315'3" 3 1 415'6" 2 1 515'9" 1 1 615'9" 1 816'0" 1 716'0" 8 116'3" 7 1 116'6" 6 1 216'9" 5 1 317'0" 4 1 417'3" 2 1 517'6" 2 1 617'9" 1 1 718'0" 1 818'3" 7 1 218'6" 6 1 318'9" 5 1 419'0" 4 1 519'3" 3 1 619'6" 2 1 719'9" 1 1 820'0" 1 922'0" 1 1024'0" 1 11

Not Available

Not AvailableNot Available

Page 12: First Energy Quote
Page 13: First Energy Quote
Page 14: First Energy Quote
Page 15: First Energy Quote

Lip 18" Lip 20" Weather SealsFoam InsulationAbrasive DeckExplosion Proof3 Phase Motor 208 Volt 230 Volt 460 Volt 575 Volt

JOB

"HP" SERIES HYDRAULIC LEVELER SUBMITTAL DRAWING

STANDARD FEATURES(2) Bumpers

Lip 16"

Grease Fittings

Full Range Toe Guards

Deck Support, Structural 6" x 8.2 lb./ft. C Channel

Fully Hydraulic Actuation

Automatic Recycle

OPTIONAL FEATURES

NOTES

"HP" SERIES HYDRAULIC DOCK LEVELER MODEL SPECIFICATIONS

LIP*

1/2" x 16"1/2" x 16"5/8" x 16"5/8" x 16"5/8" x 16"5/8" x 16"1/2" x 16"5/8" x 16"

5/8" x 16"

DECK*

1/4"1/4"1/4"1/4"1/4"1/4"1/4"1/4"1/4"

NOMINAL LENGTH

6'8'6'6'8'8'10'10'

10'

WIDTH

72"/83"72"/83"

72"83"72"83"

72"/83"72"72"

HINGE CF1045

1" diameter1" diameter

1 1/8" diameter1 1/8" diameter1 1/8" diameter1 1/8" diameter

1" diameter1 1/8" diameter1 1/8" diameter

SEAMLESS HINGE TUBE

OPERATINGRANGE

INSERT SPECIFIC JOB REQUIREMENTS FROM CHART

* Lip and deck, 55,000 lb. minimum yield steel; 5 year structural warranty.** Models with deck width of 78" (6 1/2') are available upon request.

STANDARD CAPACITY A.N.S.I. CAPACITY

MODEL

HP6625,30/HP7625,30

HP6825,30/HP7825,30HP6635,40,45HP7635,40,45HP6835,40,45HP7835,40,45

HP61025,30/HP71025,30HP61035,40,45

HP71035,40,45

1 5/8" dia. O.D.

1 5/8" dia. O.D.2" dia. O.D.2" dia. O.D.2" dia. O.D.2" dia. O.D.

1 5/8" dia. O.D.2" dia. O.D.

2" dia. O.D.

+ 12" - 12"+ 12" - 12"+ 12" - 12"+ 12" - 12"+ 12" - 12"+ 12" - 12"+ 16" - 16"+ 16" - 16"+ 16" - 16"

�����

��

���

Emergency StopThree Wheel Fork LiftIndependent Lip ControlYellow & Black Diagonal Safety Stripe on Toe GuardsLaminated Bumpers __________ sizePan Units Four Sided Pans Three Sided Pans

In-line Safety Stop (prevents free-fall)

Motor -- 1 hp. 1 ph. 60 Hz

115 Volt

230 Volt

Lip Keeper/Night Locks

Maintenance Strut

Below Dock Control

08/06

Page 16: First Energy Quote

JOB

"HP" SERIES HYDRAULIC LEVELER PIT DETAIL

NOTES

NOT TO SCALE

SECTION "A-A"MAT'L: A-36 C. STEEL

19 1/2"

FRONT ELEVATION

A

A

PIT

10"

BOX

16"TYP

3/16"

MAT'L: A-36 C. STEEL

PIT

PLAN

DRAWN:

J.M.G.

SCALE:

AS NOTED

DATE:

1/30/95

DRAWING NUMBER:

PMI-2014-R1

TOLERANCES:Inch Dimension = 1/16"

Decimal Dimension = .005

Angles = 1+ - + - + -

6'W x 6'L 6'W x 8'L 6'-6"W x 6'L6'-6"W x 8'L7'W x 6'L 7'W x 8'L 6'W x 10'L6'-6"W x 10'L7'W x 10'L

74" 74" 80" 80" 85" 85" 74"80" 85"

MODEL "A" "B" "C" "D"

VARIABLE DIMENSIONS

INSERT SPECIFIC JOB DIMENSIONS FROM CHART

63" 87" 63" 87" 63" 87" 111"111"111"

20" 20" 20" 20" 20" 20" 24" 24"24"

191/2"191/2"191/2"191/2"191/2"191/2"231/2"231/2"231/2"

DIM. B

DIM. APit Width

DIM. D DIM. C

Pit Length

EMBEDDED CONDUITREQUIRED FOR ELECTRIC HYDRAULIC UNIT(S)(1" RECOMMENDED)

MAT'L: A-36 C. STEEL

TOP OF DOCK

48" TO 50"(RECOMMENDED)

DOCK HEIGHT)

Depth Front

1/2" SLOPE(RECOMMENDED)

Depth Rear

REAR PIT WALL TO BE SQUAREWITH DOCK FLOOR (REVERSE SLOPEUP TO 1/2" AS SHOWN IS ACCEPTABLE)

C

C

C

Pit Curb Angle

JOB

"HP" SERIES HYDRAULIC LEVELER PIT DETAIL

NOTES

NOT TO SCALE

SECTION "A-A"MAT'L: A-36 C. STEEL

19 1/2"

FRONT ELEVATION

A

A

PIT

10"

BOX

16"TYP

3/16"

MAT'L: A-36 C. STEEL

PIT

PLAN

DRAWN:

J.M.G.

SCALE:

AS NOTED

DATE:

1/30/95

DRAWING NUMBER:

PMI-2014-R1

TOLERANCES:Inch Dimension = 1/16"

Decimal Dimension = .005

Angles = 1+ - + - + -

6'W x 6'L 6'W x 8'L 6'-6"W x 6'L6'-6"W x 8'L7'W x 6'L 7'W x 8'L 6'W x 10'L6'-6"W x 10'L7'W x 10'L

74" 74" 80" 80" 85" 85" 74"80" 85"

MODEL "A" "B" "C" "D"

VARIABLE DIMENSIONS

INSERT SPECIFIC JOB DIMENSIONS FROM CHART

63" 87" 63" 87" 63" 87" 111"111"111"

20" 20" 20" 20" 20" 20" 24" 24"24"

191/2"191/2"191/2"191/2"191/2"191/2"231/2"231/2"231/2"

DIM. B

DIM. APit Width

DIM. D DIM. C

Pit Length

EMBEDDED CONDUITREQUIRED FOR ELECTRIC HYDRAULIC UNIT(S)(1" RECOMMENDED)

MAT'L: A-36 C. STEEL

TOP OF DOCK

48" TO 50"(RECOMMENDED)

DOCK HEIGHT)

Depth Front

1/2" SLOPE(RECOMMENDED)

Depth Rear

REAR PIT WALL TO BE SQUAREWITH DOCK FLOOR (REVERSE SLOPEUP TO 1/2" AS SHOWN IS ACCEPTABLE)

C

C

C

Pit Curb Angle

JOB

"HP" SERIES HYDRAULIC LEVELER PIT DETAIL

NOTES

NOT TO SCALE

SECTION "A-A"MAT'L: A-36 C. STEEL

19 1/2"

FRONT ELEVATION

A

A

PIT

10"

BOX

16"TYP

3/16"

MAT'L: A-36 C. STEEL

PIT

PLAN

DRAWN:

J.M.G.

SCALE:

AS NOTED

DATE:

1/30/95

DRAWING NUMBER:

PMI-2014-R1

TOLERANCES:Inch Dimension = 1/16"

Decimal Dimension = .005

Angles = 1+ - + - + -

6'W x 6'L 6'W x 8'L 6'-6"W x 6'L6'-6"W x 8'L7'W x 6'L 7'W x 8'L 6'W x 10'L6'-6"W x 10'L7'W x 10'L

74" 74" 80" 80" 85" 85" 74"80" 85"

MODEL "A" "B" "C" "D"

VARIABLE DIMENSIONS

INSERT SPECIFIC JOB DIMENSIONS FROM CHART

63" 87" 63" 87" 63" 87" 111"111"111"

20" 20" 20" 20" 20" 20" 24" 24"24"

191/2"191/2"191/2"191/2"191/2"191/2"231/2"231/2"231/2"

DIM. B

DIM. APit Width

DIM. D DIM. C

Pit Length

EMBEDDED CONDUITREQUIRED FOR ELECTRIC HYDRAULIC UNIT(S)(1" RECOMMENDED)

MAT'L: A-36 C. STEEL

TOP OF DOCK

48" TO 50"(RECOMMENDED)

DOCK HEIGHT)

Depth Front

1/2" SLOPE(RECOMMENDED)

Depth Rear

REAR PIT WALL TO BE SQUAREWITH DOCK FLOOR (REVERSE SLOPEUP TO 1/2" AS SHOWN IS ACCEPTABLE)

C

C

C

Pit Curb Angle

JOB

"HP" SERIES HYDRAULIC LEVELER PIT DETAIL

NOTES

NOT TO SCALE

SECTION "A-A"MAT'L: A-36 C. STEEL

19 1/2"

FRONT ELEVATION

A

A

PIT

10"

BOX

16"TYP

3/16"

MAT'L: A-36 C. STEEL

PIT

PLAN

DRAWN:

J.M.G.

SCALE:

AS NOTED

DATE:

1/30/95

DRAWING NUMBER:

PMI-2014-R1

TOLERANCES:Inch Dimension = 1/16"

Decimal Dimension = .005

Angles = 1+ - + - + -

6'W x 6'L 6'W x 8'L 6'-6"W x 6'L6'-6"W x 8'L7'W x 6'L 7'W x 8'L 6'W x 10'L6'-6"W x 10'L7'W x 10'L

74" 74" 80" 80" 85" 85" 74"80" 85"

MODEL "A" "B" "C" "D"

VARIABLE DIMENSIONS

INSERT SPECIFIC JOB DIMENSIONS FROM CHART

63" 87" 63" 87" 63" 87" 111"111"111"

20" 20" 20" 20" 20" 20" 24" 24"24"

191/2"191/2"191/2"191/2"191/2"191/2"231/2"231/2"231/2"

DIM. B

DIM. APit Width

DIM. D DIM. C

Pit Length

EMBEDDED CONDUITREQUIRED FOR ELECTRIC HYDRAULIC UNIT(S)(1" RECOMMENDED)

MAT'L: A-36 C. STEEL

TOP OF DOCK

48" TO 50"(RECOMMENDED)

DOCK HEIGHT)

Depth Front

1/2" SLOPE(RECOMMENDED)

Depth Rear

REAR PIT WALL TO BE SQUAREWITH DOCK FLOOR (REVERSE SLOPEUP TO 1/2" AS SHOWN IS ACCEPTABLE)

C

C

C

Pit Curb Angle

JOB

"HP" SERIES HYDRAULIC LEVELER PIT DETAIL

NOTES

NOT TO SCALE

SECTION "A-A"MAT'L: A-36 C. STEEL

19 1/2"

FRONT ELEVATION

A

A

PIT

10"

BOX

16"TYP

3/16"

MAT'L: A-36 C. STEEL

PIT

PLAN

DRAWN:

J.M.G.

SCALE:

AS NOTED

DATE:

1/30/95

DRAWING NUMBER:

PMI-2014-R1

TOLERANCES:Inch Dimension = 1/16"

Decimal Dimension = .005

Angles = 1+ - + - + -

6'W x 6'L 6'W x 8'L 6'-6"W x 6'L6'-6"W x 8'L7'W x 6'L 7'W x 8'L 6'W x 10'L6'-6"W x 10'L7'W x 10'L

74" 74" 80" 80" 85" 85" 74"80" 85"

MODEL "A" "B" "C" "D"

VARIABLE DIMENSIONS

INSERT SPECIFIC JOB DIMENSIONS FROM CHART

63" 87" 63" 87" 63" 87" 111"111"111"

20" 20" 20" 20" 20" 20" 24" 24"24"

191/2"191/2"191/2"191/2"191/2"191/2"231/2"231/2"231/2"

DIM. B

DIM. APit Width

DIM. D DIM. C

Pit Length

EMBEDDED CONDUITREQUIRED FOR ELECTRIC HYDRAULIC UNIT(S)(1" RECOMMENDED)

MAT'L: A-36 C. STEEL

TOP OF DOCK

48" TO 50"(RECOMMENDED)

DOCK HEIGHT)

Depth Front

1/2" SLOPE(RECOMMENDED)

Depth Rear

REAR PIT WALL TO BE SQUAREWITH DOCK FLOOR (REVERSE SLOPEUP TO 1/2" AS SHOWN IS ACCEPTABLE)

C

C

C

Pit Curb Angle

08/06

Page 17: First Energy Quote

PIONEER LOADING DOCK EQUIPMENT

“HP” Series Hydraulic Pit Leveler Architectural Specifications

A. Manufacturer

1. Design is based on products manufactured by; PIONEER Loading Dock Equipment 740 Beechcroft Rd. Spring Hill, TN 37174 800-251-3382 (931) 486-2296

2. Type: Loading dock leveler shall be fully hydraulic, push button operated with no moving parts.

B. Product Characteristics: Dock Levelers

1. Product: Fully Hydraulic dock leveler – Model HP_____________

2. Size: ____” wide x ____’ long, ____” deep to fit ____” deep pit.

3. Capacity: _____________ lbs. Dynamic

4. Construction: The platform shall be ¼” thick, 55,000 lb. minimum yield steel tread plate. Platform support shall be structural steel “C” channel welded at front of leveler to full width header plate. No formed sheet metal shapes will be acceptable. Lip shall be ½” thick (5/8” thick on 35K and above), 55,000 lb. minimum yield steel tread plate with a projection beyond the platform edge of 16” and 12” beyond the bumpers. Lip hinge pin shall be 1 1/8” cold rolled CF1045 steel shaft. Hinge tubes are 2” I.D. seamless with grease fittings. Exclusive structural base frame safety struts will transfer unsupported load forces into the pit floor rather than the embedded angle in case of premature truck departure. Toe guards shall be full range telescoping type as standard.

5. Operation: Fully automatic deck and lip actuation. Single push button

remote controls all stages of operation. When button is depressed leveler will raise and lip will extend. When button is released, unit will descend, lip will automatically retract and leveler will return to stored position. HP series

Page 18: First Energy Quote

automatically returns to safe, cross traffic position when truck departs via solid state proximity sensors. No limit switches to be accepted.

6. Characteristics: Unit shall have a working range of 12” above and 12”

below dock level. A velocity fuse, or in line safety stop, is standard and shall provide positive stop in case of premature truck departure. Ramp to be recyclable with truck in position at dock. Cross traffic support and night lock security to be provided by lip stored in lip keepers. Deck to compensate (tilt) a maximum of 4” from side to side to service out of level trucks. Levelers and warranty shall meet or exceed the performance requirements of CS202-56., O.S.H.A. and ANSI MH-14.1. 1 – 1984.

7. Weatherseals – Brush type (meets FDA requirements) weatherseals

optional.

8. Bumpers: Two per dock leveler.

Page 19: First Energy Quote
Page 20: First Energy Quote
Page 21: First Energy Quote
Page 22: First Energy Quote
Page 23: First Energy Quote
Page 24: First Energy Quote
Page 25: First Energy Quote

PIONEER LOADING DOCK EQUIPMENT

“EVR” Automatic Truck Restraint Architectural Specifications

A. Manufacturer

1. Design is based on products manufactured by; PIONEER Loading Dock Equipment 740 Beechcroft Rd. Spring Hill, TN 37174 800-251-3382 (931) 486-2296

2. Type: Loading dock truck restraint shall be fully automatic, push button operated.

B. Product Characteristics: Truck Restraint

1. Product: Fully automatic truck restraint – Model EVR600.

2. Size: 17 ¾” wide x 28 13/16” tall. Motor housing to be 45 ½” wide x 10 ¼” tall

3. Restraining Capacity: 55,000 lbs.

4. Construction: Hook and hook housing constructed of ½”, 55,000 lb.

minimum yield steel plate (smooth).

5. Operation: Automatic push button control. Provided wall-mounted control box with Red and Green LED warning lights included.

6. Communication System: EVR600 by PIONEER, Inc.

a) Outside system: Full time flashing red and green LED lights with sun visors and 2 warning signs (one mirror reverse) for truck driver.

b) Inside system: Automatically activated, full time flashing red and green LED lights with one sign for loading / unloading operations.

c) Required power source: 110 / 115 volt, single phase.

7. Off ground mounting standard.