Page 1: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved. siemens.com/answers

SINAMICS G120 - Version 4.7 SP3Firmware functions

Page 2: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 2

• Other expanded functionality 20

• Communication 17

• Control expansions 9

• Additional motors supported 5

• New Power Modules supported 2

SINAMICS G120 Version 4.7 SP3

Page 3: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 3

V4.7 SP3 | New Power Modules supported

Continuous expansion of the Power Module hardware support

PM240-2 Power Modules FS D and E supportedincluding Safe Torque Off (STO, SIL3) via Power Module terminals

The revised PM230 Power Modules with new article numbers supported:◦ IP55 degree of protection: 6SL3223-0DE..-..G.◦ IP20 degree of protection:

and push through: 6SL321.-1NE..-..G..

New PM330 FS HX Power Modules supported

✓ CU230P-2✓ CU240B-2✓ CU240E-2✓ CU250S-2

✓ CU240E-2✓ CU250S-2

✓ CU230P-2✓ CU240B-2✓ CU240E-2

✓ CU230P-2

Page 4: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 4

• Other expanded functionality 20

• Communication 17

• Control expansions 9

• Reluctance motors 5

• Additional motors supported 4

• New Power Modules supported 3

SINAMICS G120 Version 4.7 SP3

Page 5: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 5

V4.7 SP3 | SIMOTICS 1FP1 reluctance motors supported (rated powers from 5.5 – 30 kW)

Firmware highlights Feature/function Benefits

• The motor is selected using a code number

• Optimization of the drive system

• Fast and straightforward commissioning

• Simple adaptation to the application

• High starting and acceleratingtorque using the adapted vector control

• Speed is precisely maintained, even without encoder

• Load surges are quickly corrected

• Flux reduction using vector control

• Additional energy-saving by optimizing the system for the operating point

SIMOTICS reluctance motors with SINAMICS inverters set themselves apart as a result of the high energy efficiency, high dynamic performance, user friendliness and functionality.

✓ CU230P-2✓ PM240-2

Page 6: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 6

SINAMICS G120 Version 4.7 SP3 other expansions regarding motors

Function

G110M

G120C

CU230P

-2

CU240B

-2

CU240E

-2

CU250S

-2

CU240D

-2

CU250D

-2

Customer benefits

1PH8 induction motors are selected using the code number in STARTER and STARTDRIVE wizards.

✓ ✓ ✓ ✓ ✓ Simplified commissioning of 1PH8 motors

Updated 1LE1 motor list. Selected using the code number in STARTER and STARTDRIVE- wizards.

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Simplified commissioning of 1LE1 motors

G110M: Expansion selection of motor types to include p300=10/13/17 and 19

✓This means that these motors can be correctly set and operated, e.g. correct motor temperature monitoring

G110M supplementary functions• 1LA7070-4AB 0.25kW, 87Hz• New macros based on 24, 25• Temperature-controlled Power

Module fans

✓Simplified commissioningEnergy-saving in fan operation

Page 7: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 7

SINAMICS G120 Version 4.7 SP3 other expansions regarding motors

Function

G110M

G120C

CU230P

-2

CU240B

-2

CU240E

-2

CU250S

-2

CU240D

-2

CU250D

-2 Customer benefits

One SSI encoder with incremental tracks can be used for closed-loop speed and position control.The encoder information is split, and therefore available as encoder 2 for closed-loop position control and also as encoder 1 (motor encoder) for closed-loop speed control.

✓ ✓ Applications where it is not possible to mount SSI encoders on the load side can be implemented, e.g. rotary tables in the automotive industry

Page 8: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 8

• Other expanded functionality 20

• Communication 17

• Technology controller - expansion13

• Friction torque characteristic 12

• Moment of inertia estimator 11

• SINAMICS application classes 9

• Control expansions 8

• Additional motors supported 5

• New Power Modules supported 3

SINAMICS G120 Version 4.7 SP3

Page 9: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 9

SINAMICS application classesApplication view

Standard Drive Control

Dynamic Drive Controlwithout encoder

Dynamic Drive Controlwith encoder

Motors that can be operated Induction motors Induction and synchronous motors

Power Modules that can be operated

PM330

PM240, PM240-2

Application examples • Pumps, fans and compressors with flow characteristic

• Wet or dry blasting technology

• Mills, mixers, kneaders, crushers, agitators

• Horizontal conveyor systems (conveyor belts, roller conveyors, chain conveyors)

• Basic spindles

• Pumps and compressors –position displacement machines

• Rotary kilns• Extruders• Centrifuges

• Vertical conveyor systems (lifter, lowerer, gantry cranes)

• Escalators/moving staircases

• Vertical material handling• Elevators• Gantry cranes• Cable railways• Storage and retrieval

machines

When selecting an application class, the inverter assigns the appropriate settings for the closed-loop motor control

✓ G120C✓ CU230P-2✓ CU240B-2✓ CU240E-2✓ CU250S-2

Page 10: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 10

SINAMICS application classesTechnical view

Standard Drive Control

Dynamic Drive Control without/ with encoder

Advantages Insensitive also if motor data are inaccurately set

Controls and limits the motor torque, extends the torque accuracy

Recommended for Motor power ratings < 11 kW

Ramp-up times/ acceleration times 1 s (0.1 kW) … 10 s (45 kW)

Applications with constant load torque without load surges

Motor power ratings > 11 kW

Ramp-up times/ acceleration times < 1 s (0.1 kW) … < 10 s (250 kW)

Typical correction time after a speed change

100 ms … 200 ms < 100 ms

Typical correction time after a load surge

500 ms 200 ms

… for simplified commissioning and increased degree of ruggedness of the closed-loop motor control

Wizard-prompted support throughSTARTER, STARTDRIVE, BOP-2, IOP and SINAMICS firmware

Motor control preset with appropriate settings→ increases the degree of ruggedness

Fewer parameters→ simplifies

commissioning

Application classes are available with PM240, PM240-2, PM330 and with G120C.

✓ G120C✓ CU230P-2✓ CU240B-2✓ CU240E-2✓ CU250S-2

Page 11: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 11

Moment of inertia estimator

…results in lower overshoots as well as shorter speed controller correction times for varying moments of inertia and load torques

Function:When the speed changes, the total moment of inertia of load and motor is determined from the actual speed, the actual motor torque and the low frictional torque.

MB = MM - ML - MRJ = MB / α

Automatic speed controller optimization: The required accelerating torque is determined and precontrolled from the moment of inertia that is determined and the speed setpoint change.

Customer benefits:Significantly varying moments of inertia and load torques in operation are reliably handled from a control-related perspective.

Application example: Horizontal conveyor equipment (e.g. airport baggage handling)

✓ G110M✓ G120C

✓ CU240B-2✓ CU240E-2✓ CU250S-2✓ CU240D-2✓ CU250D-2✓ ET200pro FC-2

Prerequisites:• Constant load torque during speed changes• Force-locked motor-load mechanical coupling• Closed-loop control with/without encoder → not in open-loop controlled operation

( encoderless closed-loop control at low speeds or U/f )

Page 12: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 12

Friction torque characteristic with automatic plotting

… applications with friction that cannot be neglected can be reliably handled from a control-related perspective

Function:• When requested, the inverter can automatically

plot the friction characteristic. The friction torque is determined at speeds predefined by the motor. Ten interpolation points - speed to torque.

• The torque setpoint is precontrolled based on the determined friction torque

Customer benefits:The precontrol reduces speed overshoot after speed changes. This means that applications with a load friction torque that cannot be neglected can be simply and reliably handled, e.g. applications with gearboxes or belt conveyors.

The friction torque characteristic function can be used together with the moment of inertia estimator to obtain the best control related results.

✓ G110M✓ G120C

✓ CU240B-2✓ CU240E-2✓ CU250S-2✓ CU240D-2✓ CU250D-2✓ ET200pro FC-2

Prerequisites:• It is permissible that the motor accelerates up to its rated speed

without representing risk to persons or material assets

Page 13: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 13

PID technology controller | automatic optimization

Simple and user-friendly optimization of your control process

Automatic PID controller optimizationThe optimization technique is parameterized according to the required results regarding overshoot behavior – as well as rise times and correction times of the control variable. A setpointstep is injected into the control system. From the step response, the delay time, correction time and loop gain are measured – and then control parameters KP, TN, and TV are calculated by the inverter.

Customer benefits:Simplified commissioning of your process, e.g. controlling the level in a tank with long correction times. The control parameters for your process are automatically determined.

✓ CU230P-2✓ CU240B-2✓ CU240E-2

Page 14: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 14

PID technology controller | functional expansions

The technology controller can be simply and easily adapted to your process

BiCo: Enabling the PID controller output Function: The PID controller output can be enabled depending on the occurrence of a particular condition (event).Customer benefits:Simple possibility of intervening in the closed-loop control.e.g. fans with a high moment of inertia -When starting, fans with a high moment of inertia are not able to immediately follow the PID controller output. This is only possible from a certain minimum speed.Simplification of the PID technology controllerFunction: Activating/deactivating the bypass functionWhen using the technology controller, it is no longer necessary to bypass the ramp-function generator with ramp and rounding off functions. Customer benefits: Simple commissioning HVAC applications with low dynamic requirements can use the main PID controller in the same way as the free technology controller.

✓ CU230P-2

✓ G120C✓ CU230P-2✓ CU240B-2✓ CU240E-2✓ CU250S-2

Page 15: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 15

Fast flying restart with PM330 and e.g. SIMOTICS FD

The inverter can be reliably and quickly connected to a rotating FD motor without any disturbance

General functionality:1. After the ON command, the inverter impresses a search current in the motor and increases the output frequency.2. When the output frequency reaches the actual motor speed, the inverter waits until the motor is magnetized completely.3. The inverter accelerates the motor to the speed setpoint.

✓ CU230P-2

Expansion for motors where the rated data is applicable for 100 Hz – FD motors

Stabilization at high speeds using PLL (phase-locked loop) between the voltage model and output of the closed-loop control. Can be configured using parameter p1270. As a consequence, the "flying restart" function does not have to wait for the demagnetization time of the motor – and can identify the motor speed without making a search.

Customer benefitsThe inverter can be reliably and simply connected to a rotating motor, e.g. • after a brief power interruption• an airflow drives the fan impeller• a load with a high moment of inertia drives the motor

Page 16: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 16

• Other expanded functionality 20

• Communication 16

• Control expansions 9

• Additional motors supported 5

• New Power Modules supported 3

SINAMICS G120 Version 4.7 SP3

Page 17: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 17

SINAMICS G120 version 4.7 SP3 Communication

Function

G110M

G120C

CU230P

-2

CU240B

-2

CU240E

-2

CU250S

-2

CU240D

-2

CU250D

-2 Customer benefits

Expansion of communication via Modbus, adjustable parity bit, access and automatic interconnection of the inverter analog outputs

✓ ✓ ✓ ✓ ✓ ✓ I/O (peripheral) setpoints can be directlywritten to the onboard analog output of the CU. The parity data can be adapted at the higher-level controller.

Expansion of communication via BACnet, specification of a unique object name

✓ Users do not have to change the name, as the serial number is attached to the CU designation.

The bus fault LED for communication via USS and Modbus can be switched off

✓ ✓ ✓ ✓ ✓ ✓ BF LED off, all monitoring functions regarding communication are deactivated

AS-Interface: Communication presetting using the p0015 macro

✓ Simplification

IOP V1.6 (USS) as control panel:Control signals via BICO connection can be freely configured

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Flexibility regarding interconnection. For example, a digital input can be used as ON command. The speed setpoint is received from an IOP.

Page 18: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 18

SINAMICS G120 version 4.7 SP3 Communication

Function

G110M

G120C

CU230P

-2

CU240B

-2

CU240E

-2

CU250S

-2

CU240D

-2

CU250D

-2 Customer benefits

The operating mode switch-over manual/ auto can be deactivated with IOP from V1.6 (manual/auto key) or freely configured e.g. with external key-operated switch (via digital Input of Control Unit or e.g. S7-controller (PLC) or BiCo)

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Central control of operating mode switch-over via PLC.Protection against unauthorized switchover of operating mode

Page 19: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 19

• Other expanded functionality 19

• Communication 17

• Control expansions 9

• Additional motors supported 5

• New Power Modules supported 3

SINAMICS G120 version 4.7 SP3

Page 20: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 20

SINAMICS G120 version 4.7 SP3 Other expansions

Function

G110M

G120C

CU230P

-2

CU240B

-2

CU240E

-2

CU250S

-2

CU240D

-2

CU250D

-2

Customer benefits

Line contactor control using the inverter digital output

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓Lower inverter losses and therefore energy-saving when the motor is switched off

Expansion of the temperature sensors to include DIN-Ni1000 for analog inputs AI2 and AI3

The type and therefore the characteristic of the DIN-Ni1000 temperature sensor can be selected in addition to the LG-Ni1000

Automatic switch over of the real-time clock from summer time (daylight saving) to winter time

Simplification for diagnostics/ service/ and time-dependent process controls • Overnight, the temperature of a heating

control system is reduced• The pressure of a water supply system

is increased at certain times of the day

Expansion of the load torque monitoring

✓ ✓ ✓ ✓

• Pump applications: Protection against blockage, leakage and dry running

• Fan applications: Protection against blockage and broken belt

Page 21: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 21

SINAMICS G120 version 4.7 SP3 Other expansions

Function

G110M

G120C

CU230P

-2

CU240B

-2

CU240E

-2

CU250S

-2

CU240D

-2

CU250D

-2

Customer benefits

BOP-2, IOP motor data identification– data that are determined are automatically backed up to ROM

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Simplification for users - the determined data are automatically backed up.

Process energy meterSupplies the actual energy values in [Wh] at the output terminals of the power unit (can be interconnected with BICO)

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓

Energy usage of the process can be simply transferred via fieldbus for visualization or further processing.

The unit ppm (parts per million) is included in the unit switchover concept ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓

As a consequence, sensors for measuring air quality can be more simply integrated in the technology controller.

IOP, BOP-2 and CU230P-2: Default commissioning mode with maximum/minimum frequency in Hz instead of the speed in rpm.(the unit is changeable via parameter p8552, default setting at all other Control Units is rpm)

Fan units (motor + fan) can be simply commissioned as a black box using the setpoint frequency.

Page 22: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 22

SINAMICS G120 version 4.7 SP3 Other expansions

Function

G110M

G120C

CU230P

-2

CU240B

-2

CU240E

-2

CU250S

-2

CU240D

-2

CU250D

-2

Customer benefits

IOP, BOP-2: The minimum speed is preassigned as 20% of the rated speed of the motor.

Simplification as parameterization is eliminated. For fan applications, Nmin is generally 20% of the rated speed.

G120P: Voltage-dependent current limit for PM330 (and PM240-2 FS D-F) wide-range voltage devices (500V-690V)

✓ ✓ ✓ ✓ Protects motors against overcurrent

Inversion of the control sense now also for the three additional technology controllers in the CU230P-2 (for help functions such as opening and closing heating or cooling valves) using one single parameter.

Adaptation of the response to the main technology controller

Simple adaptation to heating or cooling application by inverting the control sense.For example, to simply secure the fan control function of a climate control system, where the room temperature exceeds the setpoint temperature.

Page 23: Firmware functions SINAMICS G120 - ad. · PDF fileUnrestricted / © Siemens AG 2015. All Rights Reserved. SINAMICS G120 - Version 4.7 SP3 ... including Safe Torque Off (STO, SIL3)

Unrestricted / © Siemens AG 2015. All Rights Reserved.

Page 23

Thank you for your attention!