  • 8/11/2019 FireScan D131 - Quick Reference

    1/23

  • 8/11/2019 FireScan D131 - Quick Reference

    2/23

  • 8/11/2019 FireScan D131 - Quick Reference

    3/23

    After configuring the scanner, read one of the following codesto set desired aiming system timeout.

    aiming system disabled

    300 ms

    500 ms

    1 sec

  • 8/11/2019 FireScan D131 - Quick Reference

    4/23

    CONNECTIONS

    RS232

    With the RS232 cable, this accessory device is intended to besupplied by a UL Listed Direct Plug-in Power Unit marked"Class 2", rated 5 V, minimum 200 mA.

    USB

    With the USB cable, this accessory device is intended to besupplied by a UL Listed Power Unit marked "Class 2", or anLPS power source which supplies power directly to the reader.

    IBM USB POS

    With the USB cable, this accessory device is intended to beconnected to a UL Listed computer which supplies powerdirectly to the reader.

    (if required)

  • 8/11/2019 FireScan D131 - Quick Reference

    5/23

    PEN

    With the Pen Emulation cable, this accessory device isintended to be supplied by a UL Listed Power Unit marked"Class 2", or an LPS power source which supplies powerdirectly to the reader.

    WEDGE

    With the Wedge or PC Notebook cables, this accessory deviceis intended to be connected to either a UL Listed Computerwhich supplies power directly to the reader or a UL ListedDirect Plug-in Power Unit marked Class 2, rated 5 V,

    minimum 200 mA.

  • 8/11/2019 FireScan D131 - Quick Reference

    6/23

    DISCONNECTING THE CABLE

    READING DIAGRAM

    100 200 400

    200

    100

    0

    -100

    -200

    300 500 600

    Reading Zones (10 skew angle)

    700 800 mm

    -300mm

    300

    1.00mm

    0.12mm

    0.19mm

    0.25

    mm

    EAN0.33 mm

    0.38

    mm

    0.50mm

  • 8/11/2019 FireScan D131 - Quick Reference

    7/23

  • 8/11/2019 FireScan D131 - Quick Reference

    8/23

  • 8/11/2019 FireScan D131 - Quick Reference

    9/23

    Connect FireScanto Host

    Does a dialogbox appear

    warning that Buspower is notsufficient?

    Select desired USBinterface code

    (USB-KBD is default)

    Disconnect readerat Host

    Connect externalpower supply to

    cable and power up

    Reconnect readercable to Host andclose dialog box

    NO

    YES

    Read test codes.Reader is READY

    Load drivers(if requested)

    Load drivers(if requested)

    Green LED blinks

    Green LED off - BEEP OK

    BEEP OK

    First Start-Up

    Green LED off

    Successive start-ups will automatically recognize the previouslyloaded drivers. If external power is used, verify that externalpower is already supplied.

    NO

    YES

    Read test codes.Reader is READY

    Green LED blinks

    Green LED off - BEEP OK

    BEEP OK

    Connect FireScanto Host

    Successive Start-Ups

    Disconnect readerat Host

    Connect externalpower supply to

    cable and power up

    Reconnect readercable to Host andclose dialog box

    Does a dialog boxappear warning

    that Bus power isnot sufficient?

  • 8/11/2019 FireScan D131 - Quick Reference

    10/23

    USB INTERFACE SELECTION

    USB-KBD

    USB-COM*

    USB-IBM-Table Top

    USB-IBM-Hand Held

    USB-KBD-ALT-MODE

    USB-KBD-APPLE

    * When configuring USB-COM, the relevant files and driversmust be installed from the USB Device Installation softwarewhich can be downloaded from the web pagehttp://www.datalogic.com/services/support/.

  • 8/11/2019 FireScan D131 - Quick Reference

    11/23

    USB KEYBOARD NATIONALITY

    USB-KBD users should select one of the following KEYBOARDNATIONALITY codes. The default value is restored through theInterface Selection code.

    Belge

    Deutsch

    English

    Espaol

    Franais

    Italiano

    Svenskt

  • 8/11/2019 FireScan D131 - Quick Reference

    12/23

    USB KEYBOARD NATIONALITY (Continued)

    USA

    Japanese

    RS232 READER CONFIGURATION

    Read the RESTORE DEFAULT code, then read the interfaceselection code for your application.

    RESTORE DEFAULT

    RS232

    Standard

    POS Systems

    Nixdorf Mode A

    Fujitsu

    ICL Mode

  • 8/11/2019 FireScan D131 - Quick Reference

    13/23

    WEDGE READER CONFIGURATION

    Read the RESTORE DEFAULT code, then read the interfaceselection code for your application.

    RESTORE DEFAULT

    WEDGE

    IBM AT or PS/2 PCs

    IBM XT

    PC Notebook

    IBM SURE1

    IBM Terminal 3153

  • 8/11/2019 FireScan D131 - Quick Reference

    14/23

    WEDGE (continued)

    IBM Terminals 31xx, 32xx, 34xx, 37xx:

    To select the interface for these IBM Terminals, read thecorrect KEY TRANSMISSION code. Select theKEYBOARD TYPE if necessary (default = advanced

    keyboard).KEY TRANSMISSION MODE

    make-only keyboard

    make-break keyboard

    KEYBOARD TYPE

    advanced keyboard

    typewriter keyboard

    The following interface selection allows barcodes sent tothe PC to be interpreted correctly independently from theKeyboard Nationality used. You do not need to make aKeyboard Nationality selection.

    (default = Num Lock Unchanged)Make sure the Num Lock key on your keyboard is ON.

    IBM AT - ALT mode

    PC Notebook - ALT mode

  • 8/11/2019 FireScan D131 - Quick Reference

    15/23

    WEDGE (continued)

    Wyse Terminals

    ANSI Keyboard

    PC Keyboard

    ASCII Keyboard

    VT220 style Keyboard

    Digital Terminals

    VT2xx/VT3xx/VT4xx

    APPLE

    APPLE ADB Bus

  • 8/11/2019 FireScan D131 - Quick Reference

    16/23

    WEDGE KEYBOARD NATIONALITY

    Wedge users should select one of the following WEDGEKEYBOARD NATIONALITY codes. The default value isrestored through the Interface Selection code.

    Belge

    Deutsch

    English

    Espaol

    Franais

    Italiano

    Svenskt

    USA

    The following Keyboard Nationality selection is only valid forIBM AT compatible PCs:

    Japanese

  • 8/11/2019 FireScan D131 - Quick Reference

    17/23

  • 8/11/2019 FireScan D131 - Quick Reference

    18/23

  • 8/11/2019 FireScan D131 - Quick Reference

    19/23

    CODE SELECTION

    enabled codes

    EAN 8/EAN 13 / UPC A/UPC E without ADD ONcheck digit transmitted, no conversions

    Interleaved 2/5check digit control and transmission, variable length

    code; 4-99 characters

    Standard Code 39no check digit control, variable length code; 1-99characters

    Code 128variable length code; 1-99 characters

    disabled codes:

    EAN 128, ISBT128, Code 93, Codabar, pharmaceuticalcodes, MSI, Plessey, Telepen, Delta IBM, Code 11,Code 16K, Code 49, RSS Codes

    ADVANCED FORMATTING PARAMETERS

    concatenation disabled, no advanced formats defined

  • 8/11/2019 FireScan D131 - Quick Reference

    20/23

    OPERATING TEST

    Read the TEST codes below.

    EAN-8

    1 2 3 4 5 6 7 0

    EAN-13

    1 2 3 4 5 6 7 0 0 0 9 9 2

    Code 39 (Normal)

    1 7 1 6 2

    Code 128

    t e s t

    Interleaved 2 of 5

    0 1 2 3 4 5 6 7 8 4

    YOUR READER IS NOW READY TO READ BARCODES.To change the defaults see the HHD II Software ConfigurationManual, part number 90ACC1877.

  • 8/11/2019 FireScan D131 - Quick Reference

    21/23

    WARRANTY

    Datalogic warranties this product against defects inworkmanship and materials, for a period of 24 months from thedate of shipment, provided that the product is operated undernormal and proper conditions.

    Datalogic has the faculty to repair or replace the product, theseprovisions do not prolong the original warranty term.

    The warranty does not apply to any product that has beensubject to misuse, accidental damage, unauthorized repair ortampering.

    SERVICES AND SUPPORT

    Datalogic provides several services as well as technical supportthrough its website. Log on to www.datalogic.com/servicesand click on the links indicated for further information including:

    Datalogic Services Warranty Extensions andMaintenance Agreements

    Downloads Software Downloads, Manuals andCatalogues

    Contact Us Listing of Datalogic Subsidiaries andQuality Partners

    Authorised Repair Centres

    Products >Hand-Held Readers >Software Tools DL Sm@rtSet

    DL Sm@rtSet is a Windows-based utility program whichallows device configuration using a PC. It provides RS232

    interface configuration as well as configuration barcodeprinting.

    FCC COMPLIANCE

  • 8/11/2019 FireScan D131 - Quick Reference

    22/23

    FCC COMPLIANCE

    This device complies with PART 15 of the FCC

    Rules. Operation is subject to the following two

    conditions: (1) This device may not cause harmful

    interference, and (2) this device must accept any

    interference received, including interference whichmay cause undesired operation.

    This equipment has been tested and found to comply with thelimits for a Class A digital device, pursuant to part 15 of theFCC Rules. These limits are designed to provide reasonableprotection against harmful interference when the equipment isoperated in a commercial environment. This equipmentgenerates, uses, and can radiate radio frequency energy and, ifnot installed and used in accordance with the instruction

    manual, may cause harmful interference to radiocommunications. Operation of this equipment in a residentialarea is likely to cause harmful interference in which case theuser will be required to correct the interference at his ownexpense.

  • 8/11/2019 FireScan D131 - Quick Reference