FIRE SERVICES AT DATA CENTRE
43
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

FIRE SERVICES AT DATA CENTRE

Page 2: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

FM200 TRAINING COURSE

Page 3: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

INTRODUCTION OF FM 200

Page 4: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

THE PROPERTIES OF FM-200®

Page 5: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

WHAT IS FM-200® ?

C C C

F F F

F F

F FH

ASHRAE Designation = HFC227eaASHRAE Designation = HFC227ea

Page 6: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Fire TriangleFuel, oxygen, heat

What is fire?A series of highly exothermic chain-branching free radical reactions

Removal of any element of fire triangle results in suppression

THE PHYSICS OF FIRE

Page 7: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Removes heat, so fire can’t sustain itself

FAST & EFFICIENT PERFORMANCE

Page 8: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

FM-200® CHEMICAL/PHYSICALEXTINGUISHING MECHANISM

Physical

Chemical

80%

Physical

Chemical 20%

80%

20%

Halon 1301 FM-200®®

Page 9: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Cup Burner Conc. [Heptane] - 5.8%

Use Concentration [Minimum] - 7.5% for ISO compliance

Maximum Discharge Time limited to 10 Seconds

HOW IS FM-200® APPLIED?

Page 10: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Compact storage space requirements

FAST & EFFICIENT PERFORMANCE

Halon 1301

CO

Inert Gas

Page 11: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

FM-200® iscompletely safe for use in occupiedspaces.

HUMAN SAFETY

Page 12: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Reaches extinguishing concentration within 10 seconds

Provides ACTIVE Fire Protection

FM-200® IS FAST & EFFECTIVE

Page 13: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

FM-200® ENGINEERED SYSTEMS

Page 14: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

14

ENGINEERED CENTRAL STORAGE FM-200® SYSTEM

Raised Floor

Distribution PipeDischarge Nozzles

Smoke Detectors

Manual Station

Containers

Page 15: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Computer Rooms

PRIMARY APPLICATIONS

Page 16: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

3M™ Novec™ 1230 Fire Protection Fluid

Novec 1230 fluid has distinct environmental benefits Ozone depletion potential (ODP) of

0

5 day atmospheric lifetime

Global Warming Potential (GWP) of 1

THE NEW CLEAN AGENT

Page 17: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

FM200 CONTROL EQUIPMENT

Page 18: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Kentec Panel Kentec lock off

FM200 CONTROL EQUIPMENT

Page 19: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Kidde Panel Kidde Panel

FM200 CONTROL EQUIPMENT

Page 20: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Chubb Panel Viking & Notifier Panel

FM200 CONTROL EQUIPMENT

Page 21: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Thorn Panel

FM200 CONTROL EQUIPMENT

Page 22: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

FM200 CYLINDER

Page 23: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Kidde FM200

FM200 CYLINDER

Page 24: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Chemetron FM200

FM200 CYLINDER

Page 25: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

ThornFM200

FM200 CYLINDER

Page 26: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Fike FM200

FM200 CYLINDER

Page 27: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Siemens FM200

FM200 CYLINDER

Page 28: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

SIGNAGE BOX AND PRESSURE SWITCH

Signage Box Pressure Switch for Fed-back Signal

Page 29: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

AUTO-MANUAL Mode Selection Provided Next to the Panel Outside the Room

When Personal Before Enter the Room:

- Switch the Auto-Manual Switch to “MANUAL” - “System Inoperative” Signal Box Flash - Switch Back to “AUTO” when Leave the Room

MODE SELECTION

Page 30: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Two Detection Zones for Each SystemCross Zone OperationActivating Anyone Zone:

- Alarm Sound - “Do Not Enter” Sign Flash, Don’t Enter the Room

FM200 OPERATION IN AUTO MODE

Page 31: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Two Zones Activated:

- Two-Tone Sounder Raised - “Evacuate” Sign Flash, Evacuate Room

Immediately - A/C in the Room Will Shunt Down - System Start Count Down for 30 Sec. - Gas Discharge to Room After Count Down

FM200 OPERATION IN AUTO MODE

Page 32: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

When Personal Working inside the Room:One Zone of Alarm Activated and Alarm

Sound: - Check Any Fire Happened in Room - Inform Others to Leave the Room if Fire Happened - Go out of the Room, Push the “Manual Release”

Switch to Discharge Gas Two Zone Activated: - Evacuate Room Immediately - Go out of the Room, Push the “Manual Release”

Switch to Discharge Gas

FM200 SYSTEM OPERATION IN MANUAL MODE

Page 33: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Check Smoke Detectors- Corrosion- Dirty

- Generate False Alarm FrequentlyCheck Modules

- Simulate Tests to Check the Modules

Working Properly

MAINTENANCE OF AFA AND FM200 SYSTEMS

Page 34: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Monthly & Annual

- To Be Carried-Out By FS Contractor

MAINTENANCE

Page 35: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

What is VESDA…

INTRODUCTION OF VESDA SYSTEM

Aspirating Smoke Detection吸气式烟雾探测

Page 36: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

THEINTRODUCTION OF VESDA SYSTEM VESDA ADVANTAGE…

Page 37: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

VESDA Panel VESDA Panel

INTRODUCTION OF VESDA SYSTEM

Page 38: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Kidde HSSD Panel Kidde HSSD Panel

INTRODUCTION OF HSSD SYSTEM

鐳射探測器主機板

風機

Page 39: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Kidde HSSD Sampling Point

INTRODUCTION OF HSSD SYSTEM

Page 40: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Pre-action System

INTRODUCTION OF PRE-ACTION SYSTEM

Page 41: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

Pre-action System

INTRODUCTION OF PRE-ACTION SYSTEM

Page 42: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

THANK YOU

Page 43: FIRE SERVICES AT DATA CENTRE. FM200 TRAINING COURSE.

END