Top Banner
Sealing Global - Servicing Local w w w . l a m o n s . c o m IsoTek Isolation Defender FS Gasket Fire Safe
3

Fire Safe - Lamons · Fire Safe. The Defender ... 750-800 600 750-800 550 500 ... is an engineered fire safe gasket that has passed API 6FB fire test

Jul 19, 2018

Download

Documents

dokien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Fire Safe - Lamons · Fire Safe. The Defender ... 750-800 600 750-800 550 500 ... is an engineered fire safe gasket that has passed API 6FB fire test

Sealing Global - Servicing Local

w w w . l a m o n s . c o m

IsoTek™ Isolation Defender™ FS Gasket

Fire Safe

Page 2: Fire Safe - Lamons · Fire Safe. The Defender ... 750-800 600 750-800 550 500 ... is an engineered fire safe gasket that has passed API 6FB fire test

The Defender™ FS sealing/isolating gasket is designed to withstand the rigorous API stan-dard 6FB (Third Edition) test and therefore provides a solution for those who want to electrically isolate their flange while also requiring protection against the potential intro-duction of fire in and around the flange.

The objective of the test is to monitor the total leakage for the duration of the burn/cool-down cycle and during re-pressurization. Leakage was determined by the total water level drop through a visual sight gauge during the burn/cool-down cycles, by manually catching the water in a calibrated container during re-pressurization.

The results concluded that the Defender™ FS Gasket was able to maintain its fire safe characteristics throughout the entirety of the test. During the 30 minute burn and 30 minute cool down period, the measured leakage was 0 ml/min versus the allowable rate of 22.765 ml/min. The leakage rate during the re-pressurization cycle was 5 ml/min versus the allowable rate of 22.765 ml/min.

Based on years of technological experience with Kammpro® core design, the Defender™ FS sealing/isolating gasket not only meets but exceeds the pressure-containing capabilities in standard 6FB (Third Edition) as outlined by API.

General Features · Tested and Certified to API 6FB (Third Edition). · Two integral robust sealing elements for sealing and isolating in an engineered

Fire Safe design. · Serves as a sealing/isolation for Fire Safe Applications. · Incorporates industry proven Kammpro® sealing technology.

ApplicationsDefender™ FS gaskets are engineered for Fire Safe, extreme, high reliability sealing and electrical isolation critical service applications. · High Pressure Flanges: 2500 Class or API 10K · Critical/Extreme service · High pH service · H2S/CO2 service · Locations where end users prefer an integral seal element

and in applications where high volatile fluids are present.

Sizes · 1/2” through 24” diameter

Specialty dimensions and sizing available upon request · Available as “F” Type Gasket

IsoTek™ Defender™ FSIsolation Gaskets

API Standard 6FB Third Edition Fire Test

IsoTek™ Isolation KitsSleeves & Washers

For complete isolation, sleeves and washers are needed with an IsoTek™ sealing and iso-lation gasket. To isolate connecting flanges and protect the gasket and flange from cor-rosion, Lamons provides sleeve and washer sets to complete the isolation system. The sleeves and washers prevent current from reaching the bolts/studs and nuts.Sleeve and washer sets are available in Single and Double washer sets.

Model F = Fire SafeG10 Sleeves, Steel HC Washers

Type FGasket is installed inside bolts

Fire Test Report

In Accordance with

API Standard 6FB, Third Edition

Performed for

Lamons

6 inch Class 300 Defender FS Gasket CS Flange/ B7 Studs/ 2H Nuts

Dielectric Sleeves/ Coated Steel Washers

Start Date: May 2, 2013 End Date: May 2, 2013

Performed by

United Valve 9916 Gulf Freeway Houston, TX77034

Phone: 713-944-9852 Fax: 713-944-5964

www.unitedvalve.com

Isolation Kit Installed in Flanges

For Applications with Different Flange Types, use Lamons DefenderTM FS Gasket

RTJ Flange

Isolation Barriers

Raised Face Flange

Defender™ FS Seal Detail

0.3125” (7.93 mm)

0.156” (3.96 mm)

G11 Retainer Material

Encapsulated with PTFE Coating

Kammpro® Seal Design

Dielectric Mica Sealing Material

Matrix L110 PTFE Sealing

Element

316 SS Metal Core

Page 3: Fire Safe - Lamons · Fire Safe. The Defender ... 750-800 600 750-800 550 500 ... is an engineered fire safe gasket that has passed API 6FB fire test

w w w . l a m o n s . c o m

[email protected] [email protected]

Sleeve Material Washer MaterialASTM Test Method G10 Nomex® G10 G11 HC

D149 Dielectric Strength Volts/Mil Short Time 750-800 600 750-800 550 500

D570 Water Absorption (%) 0.5 7.0 65,000 63,000 N/AD790 Flexural Strength (psi) 65,000 18,000 0.05 0.1 N/A

Cut Through Resistance High Low N/A N/A N/A

Operating Temperature Cryogenic to 302⁰F (150⁰C)

-65 to 450⁰F (- 54 to 232⁰C)

Cryogenic to 302⁰F (150⁰C)

-100 to 392⁰F (- 73 to 200⁰C)

-40 to 450⁰F (- 40 to 232⁰C)

Sleeve and Washer Material Physical Property Specifications

API Standard 6FB Test Procedure

Note: The operating temperature for gaskets and flange isolation kits is based off the gasket retainer temperature. Seal element temperature does not dictate the minimum and maximum gas-ket operating temperature. Performance suitability and material compatibility shall be determined by the user. The Defender™ FS is an engineered fire safe gasket that has passed API 6FB fire test (Third Edition). No other claims regarding suitability/compatibil-ity for a particular application or performance in a fire are made.

ASTM Test Method G10S G11S

D149 Dielectric Strength (Volts/Mil Short Time) 750-800 550

D695 Compressive Strength (psi) 65,000 63,000D570 Water Absorption (%) 0.05 0.1D790 Flexural Strength (psi) 65,000 60,000

D256 IZOD Impact Strength (Ft-Lbs/Inch) 14.00 12.00

D638 Tensile Strength (psi) 50,000 42,000D732 Shear Strength (psi) 21,000 21,000D952 * Bond Strength (lb) 2,600 2,200

Operating Temperature Cryogenic to 302⁰F (150⁰C)

-100 to 392⁰F (-73 to 200⁰C)

Sealing/Isolation Gasket Material Physical Property Specifications

Variable Data RecordedAverage System Pressure 550.59 psiAverage Flame Temperature 1722.72°F (939.28⁰C)Time to Reach Flame Temperature of 1400°F (760⁰C) 1 minute, 30 secondsAverage Calorimeter Temperature 1329.4°F (720.7⁰C)Time to Reach Average Calorimeter Temp. of 1200°F (648⁰C) 10 minutes, 30 secondsTotal Burn Time 30 minutesTotal Cool Down Time 30 minutesTotal Repressurization Hold Time 5 minutesAverage System Pressure During Repressurization 556.71 psi