Top Banner
MUELLER TEMPLATE April 2016 Department of Environment & Conservation - Gander Clean Water Show Presenters: Jeff B. Jensen & John Palmer – Mueller Canada March 27 th , 2019 FIRE HYDRANT MAINTENANCE BEST PRACTICE
11

FIRE HYDRANT MAINTENANCE BEST PRACTICE

Feb 19, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: FIRE HYDRANT MAINTENANCE BEST PRACTICE

MUELLER TEMPLATE

April 2016

Department of Environment & Conservation - Gander Clean Water ShowPresenters: Jeff B. Jensen & John Palmer – Mueller CanadaMarch 27th, 2019

FIRE HYDRANT MAINTENANCE BEST PRACTICE

Page 2: FIRE HYDRANT MAINTENANCE BEST PRACTICE

MUELLER TEMPLATE

April 2016

FOREWORD• AWWA Manual M17 @ ACWWA.CA• AWWA C502 standard • Canada Valve Darling troubleshooting manual 1002-

001

Page 3: FIRE HYDRANT MAINTENANCE BEST PRACTICE

MUELLER TEMPLATE

April 2016

ANNUAL INSPECTION

• 2 x per year

• Check for damaged exterior parts

• Remove caps, clean, grease all – replace

• Flush Hydrant

• Use listening device for leaks while in open

• Close, repeat step

• Remove cap, inspect drainage

3

Page 4: FIRE HYDRANT MAINTENANCE BEST PRACTICE

MUELLER TEMPLATE

April 2016

THIS IS NOT THE TIME FOR HYDRANT MAINTENANCE

4

Page 5: FIRE HYDRANT MAINTENANCE BEST PRACTICE

MUELLER TEMPLATE

April 2016

PREVENTATIVE MAINTENANCE – CONFUSED?

5

Page 6: FIRE HYDRANT MAINTENANCE BEST PRACTICE

MUELLER TEMPLATE

April 2016

KNOW YOUR HYDRANTS – HAVE TOOLS

6

Page 7: FIRE HYDRANT MAINTENANCE BEST PRACTICE

MUELLER TEMPLATE

April 2016

DRY TOP OPERATION ASSEMBLY

• Operating assembly uses grease or oil

• Bearing lubricated each operation exercise

• One piece op nut / thrust collar per C502

• O-ring sealed

7

Page 8: FIRE HYDRANT MAINTENANCE BEST PRACTICE

MUELLER TEMPLATE

April 2016

TRAFFIC FEATURE

• Bury line 3-4” above

• Breakaway FlangeBreakable Cast Traffic Flange

vsStrong Ductile Extension Flange

• Breakaway CouplingBreakable Cast or SS Coupling

vsStrong Ductile or solid SS

8

Page 9: FIRE HYDRANT MAINTENANCE BEST PRACTICE

MUELLER TEMPLATE

April 2016

HYDRANT MAIN VALVE

9

• Main Valve Disc ‘ball’ –EPDM or SBR rubber

• Bronze Main Valve Seat resist corrosion

• Bronze Drain Ring for easy removal of main valve and self drain

Page 10: FIRE HYDRANT MAINTENANCE BEST PRACTICE

MUELLER TEMPLATE

April 2016

DRY BARREL COMPRESSIONTYPE HYDRANT

• Moves vertically on a stem

• Seats against the hydrant base

• 5 ¼” or 4 ½” diameter main valve

10

Page 11: FIRE HYDRANT MAINTENANCE BEST PRACTICE