TECHNICAL DATAModel No.Part No.
Alarm Current @ 24V DC 470 ΩDescription
Operating Temperature RangeOperating Humidity RangeVoltage RangeStandby CurrentSensitivity SettingMaterialSizeWeightColour
Building HeightArea Covered 2
AH-0711
-10°C to 55°C
10% to 93% Relative Humidity
12V-30V DC
25 - 75 µA
Complies with UL 268
Fire- proof plastic
2 Wire40mA
FAE-P0711
Ø102mm x 47mm (H)
130gWhite
Under 4m 4m to 20m
150m 75m 2
*Applicable for Unique 227 Fire Suppression System and Carbon Dioxide Fire Extinguishing System
*Applicable for Unique 227 Fire Suppression System
AH-0621-2 AH-0621-3 AH-0621-4FAE-P0621 FAE-P0621-3 FAE-P0621-4
N/A N/A 0.8A @30V DC
40mA 40mA140μA
Comply to UL 2680°C ~ +37.8°C
Fire-proof plastic102mm (Dia.) x 48mm(H)
45mA
130g 130gWhite
145g
0.4A @ 125V AC12 ~ 30V DC
Model No.Part No.
Alarm Contact
Voltage RangeAlarm Current @ 24V DC 470ΩStandby CurrentSensitivity Setting Ambient TemperatureMaterialDimensionsWeightColor
Specifications
Order informationAH-0621-2 2-wire
3-wire with remote indicator input4-wire with relay output
AH-0621-3AH-0621-4Effective alert area
Building Height Area CoveredUnder 4m4 ~ 20m
150 m2
75 m2
All specifications and information indicated in this catalogue are subjected to change without prior notice.
28
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
SYSTEM SENSOR Photoelectric Smoke Detector
SYSTEM SENSOR Mechanical Heat Detector
TECHNICAL DATAModel No.Part No.Maximum Installation Temperature
Alarm Temperature
Operating Humidity Range
Rate-of-Rise ThresholdOperating Voltage/ContractInput Terminal
Weight
Dimension with Mounting Bracket
5601
57°C
5% to 95% Relave Humidity
8.3°C rise per minute
6-125 VAC/3A
14-22 AWG
38°C
FAU-H5601
Ø116mm x 43mm (H)
170g
Part No.
Operating Temperature RangeModel No.
Operating Humidity RangeLatching Alarm
Standby CurrentAlarm CurrentDiameter
Operating Current
Height
0-49°C
882 (Detector) , B801RA(Base)
10% to 93% Relative Humidity
Reset by momentary power interruption
≤ 90µA
8.5-35 V DC
Min-10mA Max-130mA
102mm (4”)
FAU-P882(Detector), FAU-PB882(Base)
50mm (2”)
TECHNICAL DATA
All specifications and information indicated in this catalogue are subjected to change without prior notice.
29
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
UNIQUE Single Station Smoke Detector
TECHNICAL DATA
EFFECTIVE ALERT AREA
Model No.Part No.Indicator
SoundOperating Temperature RangeOperating Humidity RangePowerSensitivity SettingMaterialSizeWeightColourOptional Function
Building HeightArea Covered
QA22
FAE-SSQA22
90dB
-10°C to 55°C
10% to 93% Relative Humidity
9V Battery
Complies with EN 54
Fire- proof plastic
Ø105mm x 40mm (H)150g
White
Type 4: Type 2 + Type 3
Type 1: 9V Battery
Type 2: Includes signal transfer COM. N.O. N.CType 3: Built-in 100-240 V AC Plug
Battery Abnormal: Beeps and flash intermittently
Standby: Flash every 40 sec
Alarm: Flash and beep continuously
Under 4m 4m to 20m150m 75m2 2
All specifications and information indicated in this catalogue are subjected to change without prior notice.
30
UNIQUE AH-0626 Heat Detector
UNIQUE AH-0333 Heat Detector
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
EFFECTIVE ALERT AREA
TECHNICAL DATAAH0333
0°C to 55°C
10% to 93% Relative Humidity
12V-30V DC
25 - 75 µA
Complies with UL 268
Fire- proof plastic
2 Wire40mA
FAE-H0333
Ø111mm x 45mm (H)
137gWhite
Model No.Part No.
Alarm Current @ 24V DC 470 ΩDescription
Operating Temperature RangeOperating Humidity RangeVoltage RangeStandby CurrentSensitivity SettingMaterialSizeWeightColour
Building HeightUnder 4m4m to 8m
Fire Proof Building Ordinary Building90m2 50m2
45m2 30m2
*Applicable for Unique 227 Fire Suppression System and Carbon Dioxide Fire Extinguishing System
AH-0626-2 AH-0626-3 AH-0626-4N/A N/A 0.8A @30V DC
40mA 40mA20 ~ 90μA
60°C0°C ~ +37.8°C
Fire-proof plastic102mm (Dia.) x 46mm(H)
45mA
120g 120gWhite
130g
0.4A @ 125V AC12 ~ 30V DC
ModelAlarm Contact
Voltage RangeAlarm Current @ 24V DC 470ΩStandby CurrentThermal SettingAmbient TemperatureMaterialDimensionsWeightColor
TECHNICAL DATA
Order informationAH-0626-2 2-wire
3-wire with remote indicator input4-wire with relay output
AH-0626-3AH-0626-4Effective alert areaConstruction/ HeightFire-proof BuildingOrdinary Building
Under 4M90 M2
50 M2
45 M2
30 M2
4M~ 8M
*Applicable for Unique 227 Fire Suppression System
45
All specifications and information indicated in this catalogue are subjected to change without prior notice.
31
Context Plus EP203/CON
TECHNICAL SPECIFICATIONPower Supply Specification
Main supply voltageInternal power supplyMax. output currentPower rating ( including charging )
230 Vac , 50/60 Hz24 Vdc nominal3A @ 230 Vac1.5A cont, 3A peak
Detector Circuit SpecificationNumber of conventional circuitsMax. no. of smoke/heat detectors per circuitMax. combined no. of detectors & manual call points per circuit
3 @ 21-28 Vdc2032
Sounder Circuit SpecificationNumber of conventional circuitsMax. number of polarised sounder per circuit
3 (two x 1st stage, one x 2nd stage)10 @ 20mA each
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
*Applicable for Unique 227 Fire Suppression System
Part No. : UFI227-ARCP-EP203
All specifications and information indicated in this catalogue are subjected to change without prior notice.
32
Kentec Sigma A-CP Conventional Control Panel
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
TECHNICAL DATAConstructionIP Rating
Colour - lid & boxFinish
Supply VoltageMains Supply FusePower Supply DC RatingMaximum Battery SizeTrouble Contact RatingSupervisory Contact RatingFire Contact RatingNAC RatingDetection Zone CurrentDetection Zone EOL ResistorNAC EOL resistorCable CapacityOperating TemperatureOperating humidity
1.2mm mild sheet steel
115V AC or 230V AC
3 Amp 250V 20mm SB
24V 6.5 Amps
12Ah 12V (2 per panel)30V DC 1 Amp
Epoxy powder coatedRed RAL 3002 (optional grey BS 00 A 05 semi-matt)
IP30
30V DC 1 Amp2A per circuit 4A Total
1.6 milliamps
6k8 5%
10k 5%12 AWG-5°C to 50°C
<95% (non condensing)
30V DC 1 Amp
*Applicable for Unique 227 Fire Suppression System
Part No. : UFI227-SIGMA-A-CP
All specifications and information indicated in this catalogue are subjected to change without prior notice.
33
Kentec Sigma A-XT Extinguishant Control Panel
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
TECHNICAL DATAConstructionIP Rating
Colour - lid & boxFinish
Mains SupplyMains Supply FusePower Supply RatingMaximum Ripple CurrentBattery Type (Yuasa NP)Battery Charge VoltageBattery Charge CurrentBattery FuseMaximum Current Draw from BatteriesQuiescent Current of Panel In Mains FailR0V OutputSounder OutputsFault Relay Contact RatingFire Relay Contact RatingLocal Fire Relay Contact Rating
Second Stage Contact RatingFirst Stage Contact Rating
Extract Contact RatingZone Quiescent CurrentTerminal CapacityNumber of Detectors Per Zone
1.2mm mild sheet steel
230V AC or 115V AC
1.6 Amp (F1.6A L250V)
3 Amps total including battery charge 28V +/- 2V200 millivolts
Two 12 Volt 7Ah sealed lead acid in series
Epoxy powder coatedRed RAL 3002 (optional grey BS 00 A 05 semi-matt)
IP30
30VDC 1A Amp maximum
2mA maximum
12 AWG
Dependent on type (maximum 32)
30VDC 1A Amp maximum
30VDC 1A Amp maximum
30VDC 1A Amp maximum
0.7A maximum20mm, 3.15A glass
3 Amps
0.095AFused at 500mA with electronic fuse
24V Fused at 500mA with electronic fuse
30VDC 1A Amp maximum
30VDC 1A Amp maximum
27.6VDC nominal (temperature compensated)
Part No. : UFI227-SIGMA-A-XT
All specifications and information indicated in this catalogue are subjected to change without prior notice.
34
Sigma A-XT
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
TECHNICAL DATANAC RatingDetection Circuit End of LineMonitored Input End of LineSounder Circuit End of LineExtinguishant Output EOLNo. of Initiating CircuitsNo. of NAC CircuitsExtinguishant Release OutputExtinguishant Release DelayExtinguishant Release DurationSIL, AL, FLT, RST InputsZone Normal ThresholdDetector Alarm ThresholdCall Point Alarm ThresholdShort Circuit ThresholdMonitored Inputs Normal ThresholdMonitored Inputs Alarm ThresholdMonitored Inputs Short Circuit ThresholdStatus Unit/Ancillary Board ConnectionStatus Unit Power Output
0.5A per circuit6K8 5% ½ Watt resistor
6K8 5% ½ Watt resistor
10K 5% ¼ Watt resistor1N4004 Diode
3
2 x 1st Stage, 1 x 2nd Stage
Fused at 1 Amp
Adjustable 0 to 60 seconds (in 5 second steps)
Adjustable 60 to 300 seconds (in 5 second steps)Switched -ve, max resistance 100 Ohms8K ohms to 1K ohm
999 ohms to 400 ohms399 ohms to 100 ohms99 ohms to 0 ohms8K ohms to 1K ohm
999 ohms to 100 ohms
99 ohms to 0 ohms
Two wire RS485 connection
Fused at 500mA with electronic fuse
EXTRACTRELPRESS.SWITCH
LOWPRES.
SWITCH
EXTING.ABORTRELEASE
MAN.SELECTMODE2ND
STAGE1ST
STAGESOUNDER2NDPOWERDATA
STATUS UNITSREMOTE
CONTROLAUX24V
CNONOCNCNOCNCZONE 3
EZONE 1 ZONE 2NAC 2NAC 1
RSTR0V SIL AL FLT NOCNCNOCNCNOCNCFIRE
RELAYLOCAL
FIRETROUBLE
RELAY
S
S
S
S
S
S
S
S
470R
470R
470R
470R
6K8
6K8
6K8
6K8
6K8
DIO
DE
470R
SOL
10K
6K8
6K8
6K8
10K10K
To StatusUnits
RemoteControlInputs
1st StageNotification Appliances
2nd StageNotification Appliances
Auxiliary Signalling Relays
Sto
p A
ir C
on
dit
ion
ing
Rem
ote
Au
to/M
anu
alSe
lect
Sw
itch
Rem
ote
Man
ual
Rele
ase
Swit
ch
Rem
ote
Ab
ort
Sw
itch
Exti
ng
uis
han
t Re
leas
edPr
essu
re S
wit
ch
Rele
asin
g S
ole
no
id
Exti
ng
uis
han
t Lo
wPr
essu
re S
wit
ch
Rele
asin
gD
etec
tors
Peri
ph
eral
Det
ecto
rs
Extr
act
Fan
Po
wer
Shu
tdo
wn
Po
wer
Sigma A-XT PCB
*Applicable for Unique 227 Fire Suppression System
All specifications and information indicated in this catalogue are subjected to change without prior notice.
35
Program Gas Extinguishing Panel
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
STANDBY MODE
ALARM MODE
Power Supply InputOperating SystemChargerCharging Rate
Per zone (with detectors)Flashing Lights (Red LED)
Master
Per Trigger Zone Output DevicesFlashing Lights (Red LED)Per Bell
Master
TECHNICAL DATA
SIZE
240V AC 50Hz
300mA (Trickle)
5mA
75mA
Automatic/Trickle Type24V DC
2.5A (Boost)
75mA
70mA
100mA75mA30mA
120mA
No. of Zones Model no. Part no. Size (mm) (W x D x H) Normal Weatherproof
2
4
PE-HP2000
PE-HP4000
FAP-02ZCP-N
FAP-04ZCP-N
430 x 195 x 370
525 x 178 x 380
435 x 195 x 410
540 x 178 x 420
MS 1745-1/2: 2004 SIRIM QAS INT. NO. PC000552
*Applicable for Carbon Dioxide Extinguishing System
All specifications and information indicated in this catalogue are subjected to change without prior notice.
36
DEMCO Dome Bell
UNIQUE Fire Alarm Bell
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
AC TypeVoltage Amps
110 0.0097 92dB
98dB
95dB
105dB
97dB
100mm(4”) 150mm (6”) 200mm (8”)
106dB
100dB
105dB
99dB
103dB
95dB
96dB
240 0.0033
12 0.008
24 0.005
Decibel Rating @ 1m (3ft)
Decibel Rating @ 1m (3ft)DC Type
Model No.Part No.
Sound Output
Supply Voltage
FinishingSizeCurrent Consumption
TECHNICAL DATA
DECIBEL SPECIFICATION
D102
0.05 A
12/24V (DC)
110/ 240V (AC)
FAE-6AB
92 - 105 dB
150mm(6”)
Red
*Applicable for Unique 227 Fire Suppression System
*Applicable for Unique 227 Fire Suppression System and Carbon Dioxide Fire Extinguishing System
Decibel Ratings / Specification
D-122-6 6” 95dB 700gModel Gross WeightSize Decibel Rating @ 3M (10ft)
Available Models
D-122-6 6” Motorize 24V DCModel VoltageSize Type
All specifications and information indicated in this catalogue are subjected to change without prior notice.
37
Sounder / Beacon
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
TECHNICAL DATAPart No.Code No.Size
Colour
MaterialWeight
D-105
Signal Red
Mild Steel
105mm (W) x 100mm(D) x 105mm (H)
FAE-KS
0.76kg
UNIQUE Manual Key Switch
UNIQUE Call Point
TECHNICAL DATA
LowestOutput @ 1 metre 24VDC
Part No.
Current @ 24VDCVoltage RangeOperating FrequencyNumbers of TonesVolume ControlOperating TemperaturesSize ( H x W x H )Protection ClassificationApproximate Weight
Highest68dB 95dB
13mA
8 to 35VDC
FAD-FBS-4T-D155
800Hz to 1000Hz
4
Adjustment Screw
-20°C to +70°C
107 x 95 x 99 mmIP 65
182g
22mA
*Applicable for Unique 227 Fire Suppression System
*Applicable for Unique 227 Fire Suppression System
Part No.Code No.Size
Current Ratings
ConnectionMaterial
Net/Gross Weight
TECHNICAL DATAD118
250V AC 10A
12/24 V DC 10A
ABS plastic with polycarbonate panel
88mm(W) x 88mm(H) x 55mm(D)
FAE-MCP
48V DC 3A
0.15/0.18kg
Terminal – Max 2.5mm Cable2
All specifications and information indicated in this catalogue are subjected to change without prior notice.
38
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
Lens ColourDimensionModel No.Part No.
Lens MaterialCasing Colour
Casing MaterialOperating VoltageOperating Current
TECHNICAL DATA
265 (L) x 110 (H) x 80 (W) mm
KP-309
FAE-ES
Red
24V DC
30mA
Black
PolycarbonateMild Steel
UNIQUE Twin Flashing Lights
Evacuate Sign
Emergency Key Box
Part No.Code No.Size
ColourMaterial
Net Weight
TECHNICAL DATAD106
Red125g
ABS PlasticØ100mm x 32mm (H)
FAD-EKB
Part No.Model No.
Luminary
Lens
SizeMaterial (Casing & Hood)Finishing
TECHNICAL DATAD-104L/WP (LED)
FAE-FLO-LED
210mm(W) x 77mm(D) x 108mm(H)
Mild SteelBlack casing with green and red lens
High efficient prismatic polycarbonate lens optimized for omnidirectional viewing.
Filament Bulb/Ultra Bright LED
*Applicable for Unique 227 Fire Suppression System and Carbon Dioxide Fire Extinguishing System
*Applicable for Unique 227 Fire Suppression System
All specifications and information indicated in this catalogue are subjected to change without prior notice.
39
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
UNIQUE Sealed Lead Acid Battery
GP Sealed Lead Acid Battery
12 12 12
65 989594 167
100 1672.35 5.50
1013.70
77
17.07.2 12.0
151 181151
GPP1272 GPP12120 GPP12170Part No.Nominal Voltage (V)Capacity ( AH )Length ( mm )Width ( mm )Height ( mm )Total Height ( mm )Weight ( kg )
TECHNICAL DATA
*Applicable for Unique 227 Fire Suppression System
*Applicable for Carbon Dioxide Fire Extinguishing System
12V 7AH BAT-007AH12V 10AH12V 12AH12V 17AH12V 24AH12V 40AH12V 65AH
12V 100AH12V 120AH
12121212121212
1212
7101217244065
100120
100100100166127170193
240233
1.993.233.485.057.72
12.3021.31
29.9035.60
BAT-010AHBAT-012AHBAT-017AHBAT-024AHBAT-040AHBAT-065AH
BAT-100AHBAT-120AH
Model Part No. NominalVoltage
(V)
Capacity(AH)
65989876
166165167
170174
Width(mm)
151151151180176197355
330405
Length(mm)
Height(mm)
Approx.Weight
(kg)
TECHNICAL DATA
All specifications and information indicated in this catalogue are subjected to change without prior notice.
40
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
Power Line Surge Protector
TECHNICAL DATAModel No.Location CategoryStandard Compliance
Nominal Continuous Operating Voltage (Un)
Nominal Discharge Current (In)(8/20μs)Rated load current (IL)Protection Level (Up)Mode of protectionIP CodeDimensionsWorking environmentsCable size
Method Of MountingMaximum Continuous Operating Voltage (Uc)
Maximum Discharge Current (Imax)(8/20μs)
Number Of Ports
Indoor, Boundary LPZ1 – LPZ2
IEC 61643-1 Class III, AS / NZS 1768, IEEE C62.41, IEC 6-1000-4-5, UL1449 3rd Edition
240V
3kA
5A
<600VL-L, L-E, L-N & N-E
IP2092mmx17mmx62mm
Temperature -40°C to +70°C, Relative Humidity ≤ 95%
0.75 – 2.5mm
Fixed (DIN 35mm Railway)
300V
10kA
1
240-5A-10
2
*Applicable for Unique 227 Fire Suppression System
All specifications and information indicated in this catalogue are subjected to change without prior notice.
41
FIRE DETECTION & ALARM SYSTEM
UNIQUE FIRE INDUSTRY SDN BHD Co. No. 418731-U
No. 9, Jalan Anggerik Mokara 31/55, Kota Kemuning, Seksyen 31, 40460, Shah Alam, Selangor, Malaysia T: +603 5131 1226 F: +603 5131 3326 (Account) F: +603 5131 3826 (Sales) F: +603 5131 2731 (Sales)F: +603 5131 1863 (Counter Sales) E: [email protected] W: www.uniquefire.com
Signal Line Surge Protector
TECHNICAL DATAModel No.Standard Compliance
Maximum Operating Voltage, U
Load Current, I
In-line resistance (per line ± 10%)Response time, tAFrequency (at -3dB)Insertion lossProtection ModeMethod of mountingIP codeDimensionsWorking environments
Maximum discharge current, I(8/20μs)
Nominal discharge current, I (8/20 μs)
Voltage protection level, U(10/700μs, 5kV)
Nominal Voltage, U
SP1-24PKT-DC
5kV (10/700 μs) to International Telecommunication Union (ITU-T K.20, K.21 and K.45)
32Vdc
2A
<1.0Ω
≤ 1ns
20MHz≤ 0.5dB
Line-Line and Line-PEDIN 35mm railwayIP20
90mm x 65mm x 13mm :Pluggable
Temperature -20°C - +80°C, Relative humidity ≤ 95%
10kA
5kA
<48Vdc
42Vdc
max
c
n
n
L
P
*Applicable for Unique 227 Fire Suppression System
All specifications and information indicated in this catalogue are subjected to change without prior notice.
42