(217) 352-9330 | [email protected]| artisantg.com -~ ARTISAN ® ~I TECHNOLOGY GROUP Your definitive source for quality pre-owned equipment. Artisan Technology Group Full-service, independent repair center with experienced engineers and technicians on staff. We buy your excess, underutilized, and idle equipment along with credit for buybacks and trade-ins . Custom engineering so your equipment works exactly as you specify. • Critical and expedited services • Leasing / Rentals/ Demos • In stock/ Ready-to-ship • !TAR-certified secure asset solutions Expert team I Trust guarantee I 100% satisfaction A ll trademarks, brand names, and br ands appearing herein are the property of their respecti ve owners. Find the Advantest R3131A at our website: Click HERE
14
Embed
Find the Click HERE€¦ · on the PC (.txt, .bmp) PERSONAL SPECTRUM ANALYZER 5 Print-Out 2 Open in Excel format 3 Data editing 1 Save in txt format 4 Data Recall 5 Print-Out Artisan
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Common KeysAuto Tune, counter and powermeasurements made simple bythese keys.
Front Panel Layout Data Entry KeysThe data entry keys arranged togetherwith the FREQ, SPAN, and LEVEL basicfunctions improves operability.
Marker KeysVarious marker functions like deltamarker and peak search function areavailable.
Control KeysFor setting bandwidth, sweep andvarious parameters, R3131A meetsto all the measurements.
Floppy Disk DriveMeasurement parameters and results can berecorded on a 3.5-inch floppy disk.Because the bitmap and text formats are compatible,the recordeddata can easily be transferred to a PC.
Independent operation keys improve operabilityAUTO TUNESearches for the signal with the maximumlevel within the 3 GHz band and sets thecenter frequency automatically. Then,reproduces the setting which existedimmediately before execution of AUTOTUNE, allowing observation under the samemeasurement conditions.
COUNTERPerforms frequency measurement with thebuilt-in frequency counter simply by movingthe marker to the signal. You can select ameasurement resolution from 1Hz up to1kHz. The measurement results are displayedwith enlarged characters, for easy viewing.
POWER MEASUREThe R3131A can measure the power withinthe specified band of frequency diffuse signalsand the total power of multi-carrier signals. Itcan also be used to measure the occupiedfrequency bandwidth (OBW) and adjacentchannel leakage power (ACP) which areessential to transmission characteristics testingfor radio equipment.
Channel Power
The R3131A allows you to measure the total power within thewindow and display it as the channel power simply by settingthe measurement window to the specified occupied bandwidth.
Total Power
Obtains the total power from the spectrum displayed on thescreen. This function is useful for total power measurement ofmulti-carrier signals.
OBW
Measures the frequency band which contains 99% of the totalpower of the spectrum displayed on the screen. In addition,the % value of OBW can be set to any desired value.
ACP
The measurement results can be displayed in graphical form,including upper and lower point data, up to the 2nd ACP,respectively, offset from the carrier and leakage power value atall the displayed frequency points.
SAVE/RECALLThe R3131A allows you to store and recall measured waveformdata and measurement conditions. The R3131A unit offers upto 10 dedicated files for storage. In addition, the built-instandard floppy disk drive allows, you to store them on MS-DOS formatted floppy disks.
MULTIPLE MARKERSUp to 10 markers can be set. Therefore, this feature is usefulfor applications that require the measurement of each level ofmultiple carrier signals, filter cutoff characteristics, etc. atmultiple marked points.
PASS/FAILThere is a choice of two types of limit tests for waves to bemeasured. One is a simple method, in which either a signallevel or frequency is evaluated for wave shape in accordancewith a given window range. The other is a limit line method,in which electromagnetic compatibility (EMC) and filter char-acteristics are evaluated in accordance with the limit lines.
GATED SWEEPBursted signals could not directly be observed with formerspectrum analyzers. The R3131A allows spectrum analysis ofthe burst signal by supplying a trigger signal synchronizingwith the burst transmission.
6 R3131A-4E Jan. ´02
GATED SWEEP OFF
GATED SWEEP ON
The window range set along the X and Y axes is the PASS area. Thesignal level or frequency at a marked point is evaluated in accordancewith the range.
Any UPPER and LOWER limit lines can be set. Pass or Fail judge-ment can be made in accordance with the limit lines.
This function measures electromagnetic interference generatedby various electronic equipment. This function incorporatesthe 9 kHz and 120 kHz RBW and QP detector conforming tothe CISPR Pub.16-1 standard. In addition, using the AM/FMdemodulation signal fed from the PHONE jack on the rearpanel, you can identify broadcasting radio waves which act asexternal noise. Prior to measurement of noise emission on theapproved site, this function is very useful for preparatoryevaluation and solution.
Various antenna correction factors provided by Advantest arebuilt-in the R3131A. Simply by selecting the Model name ofthe antenna, the level indication of the R3131A is calibrated toan absolute value, allowing you to read the value directly in
unit of dBµ/m. When you use an antenna from othermanufacturers, you can reflect its antenna correction factor inthe level indication of the R3131A by performing steps and
below.
Diverse measurement functionsThe MEAS key incorporates the XdB Down measurementfunction which is useful for noise measurement, AMmodulation measurement, 2-signal 3rd-order distortionmeasurement, and filter cut-off frequency measurement. Innoise measurement, bandwidth conversion can easily be madeand the PBW calibration function for improvement ofmeasurement accuracy is effective. The PBW calibrationfunction is a new calibration function which performscorrection, in power measurement, based on conversion of theR3131A resolution bandwidth filter to an ideal filter, therebyallowing measurement with higher accuracy.
7R3131A-4E Jan. ´02
Antenna and Level Correction Functions (EDIT of Corr.table is not performed by the R3131A unit.)
SHIFT
RECALL
SAVE
Save
Save Item
Protect
Delete
1. Set Antenna Correction to ON and SAVE the file.
2. OPEN the file from the floppy disk using Excel on the PC.
3. Enter the frequency and correction level in the ⟨ANT CORR⟩ area and then overwrite it on the floppy disk.
4. Load the floppy disk in the R3131A and then RECALL the file. The Correction table is created.
Setup ON/OFF
Trace ON/OFF
AntennaCorrection ON/OFF
MAX. 50 Points
1
2
Set Correction to ON. The corrected data is reflected on the screen data.
Improved system throughputThe throughput of production and adjustment lines is largelyaffected by the measurement time of measuring instrumentsand data transmission time. With newly developed internalprocessing technology, the R3131A has shortened the timenecessary for GPIB control and data transmission by half ormore in comparison with former products. In addition, byreducing the settling time of the local oscillator, the waveformupdate rate in unit time has been doubled.(In either case, comparison is made under the same conditions.)
Use of Data Save/Recall of the R3131A
8 R3131A-4E Jan. ´02
Series of center frequency, sweep,marker, and data load operations
Former productsfrom Advantest
Former productsfrom Advantest
Former productsfrom Advantest
Former productsfrom AdvantestR3131A
About2.2 seconds
About1.2 seconds
About1.6 seconds
About0.7 seconds
About0.7 seconds
About0.3 seconds
About5 times/second
About10 times/second
R3131A R3131A R3131A
Trace data output Actual measurement Trace data update
The tracking generator (OPT.74) is a monoblock optionwhich is integrated in R3131A. It can generate constant levelsignal synchronized with sweep frequency in the frequencyrange up to 3 GHz and therefore can easily measure thefrequency characteristic of object device. Besides, with thenormalize function which cancels the frequency characteristicof measuring system, highly accurate measurement is possible.Because the output level can be set in a wide range (from 0 to-59.9 dBm, in 0.1 dB steps), it can be used to measure filterpass characteristic, cable loss, amplifier gain, etc.
For the measurement of reflection characteristic
With the SWR bridge, the reflection characteristic of antennasand filters can be measured.
For the measurement of cable loss
With the short cable, the high-frequency loss characteristic ofcable can be measured from the differential when the objectcable is connected.
Artisan Technology Group is an independent supplier of quality pre-owned equipment
Gold-standard solutions Extend the life of your critical industrial,
commercial, and military systems with our
superior service and support.
We buy equipment Planning to upgrade your current
equipment? Have surplus equipment taking
up shelf space? We'll give it a new home.
Learn more! Visit us at artisantg.com for more info
on price quotes, drivers, technical
specifications, manuals, and documentation.
Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate, representative, or authorized distributor for any manufacturer listed herein.
We're here to make your life easier. How can we help you today? (217) 352-9330 I [email protected] I artisantg.com