CHAPTER 4: DATA PRESENTATION AND ANALYSIS 4.1 SITE INVENTORY 4.1.1.1. SITE SELECTION CRITERIA Site pre-selection is recommended based on a set of criteria to maximize the impact of the project. This is to ensure that the proposed development may be able to economically maximize the given lot. Moreover, this is to prove that the site to be chosen is favorable for the nature of the proposed project. The researcher laid out a set of criteria, mainly divided into two categorized as the major and minor site criteria. The major site criteria consists criterions based on the pertaining laws on the proposed development. These criteria were the ones which considered site values that are highly compatible with the requirements and specific needs of a high rise mixed-used development. Major Site Selection Criteria take on a higher percentage with a total value of 60%. The minor criteria were the ones that refer to the factors that are usually considered and are generally applicable to most type of projects rather than high rise developments. Minor Site Selection Criteria take on the remaining 40% the site selection process. 4.1.1.1.1 MAJOR CRITERIA • Availability of Basic needs – Necessary amenities for the proposed high rise mixed-use development shall be preferably available within reasonable distance from the project site. If such requirements are not available, the same shall be provided for by the developer. • Zoning/ Land Use Plan of the City – Generally, mixed-use projects should conform to the zoning ordinance of the city/municipality where they are to be located thus shall be in suitable sites for mixed-use developments. • Physical Suitability – A potential site must have characteristics assuring business opportunities, safety and environmentally sound community life. It shall be stable enough to accommodate foundation load without excessive site works. Critical areas such as those which are subject to calamities and other dangerous effects must be avoided.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
CHAPTER 4: DATA PRESENTATION AND ANALYSIS
4.1 SITE INVENTORY
4.1.1.1. SITE SELECTION CRITERIA
Site pre-selection is recommended based on a set of criteria to maximize the impact of the project.
This is to ensure that the proposed development may be able to economically maximize the given lot.
Moreover, this is to prove that the site to be chosen is favorable for the nature of the proposed project. The
researcher laid out a set of criteria, mainly divided into two categorized as the major and minor site criteria.
The major site criteria consists criterions based on the pertaining laws on the proposed development.
These criteria were the ones which considered site values that are highly compatible with the requirements
and specific needs of a high rise mixed-used development.
Major Site Selection Criteria take on a higher percentage with a total value of 60%. The minor
criteria were the ones that refer to the factors that are usually considered and are generally applicable to
most type of projects rather than high rise developments. Minor Site Selection Criteria take on the
remaining 40% the site selection process.
4.1.1.1.1 MAJOR CRITERIA
• Availability of Basic needs – Necessary amenities for the proposed high rise mixed-use
development shall be preferably available within reasonable distance from the project site. If
such requirements are not available, the same shall be provided for by the developer.
• Zoning/ Land Use Plan of the City – Generally, mixed-use projects should conform to the
zoning ordinance of the city/municipality where they are to be located thus shall be in
suitable sites for mixed-use developments.
• Physical Suitability – A potential site must have characteristics assuring business
opportunities, safety and environmentally sound community life. It shall be stable enough to
accommodate foundation load without excessive site works. Critical areas such as those
which are subject to calamities and other dangerous effects must be avoided.
• Accessibility – The site must be served by a road that is readily accessible to public
transportation lines. The said access road shall conform to the standards set in pertaining
rules to accommodate expected demand caused by the incoming development of the area.
4.1.1.1.2 MINOR CRITERIA
• Presence of Utilities - This criterion is needed because it makes the site be an efficient
one as it has the presence of potable and tap water supply, electric connection, and an
efficient drainage system. It also justifies how the users will be able to maximize the given
site, if the presence of the utility system is there.
• Orientation – The site must have a good site orientation as this factor provide a significant
impact on the proposed development and program of the site. Efficient orientation of the site
will allow the users to utilize the existing environment in terms of solar and wind energy.
• Size/ Shape – The site configuration and area allow the maximum spaces given in the
layout which can be developed for the project. The site must be able to provide ample space
for the parking lots, parks, and other usable spaces without sacrificing required setbacks and
walkways for the development.
SITE SELECTION CRITERIA
PERCENTAGE SUMMARY
MAJOR CRITERIA (60%) PERCENTAGE
1. Availability of Basic Needs 20%
2. Zoning/ Land Use Plan 15%
3. Accessibility 15%
4. Physical Suitability 10%
MINOR CRITERIA (40%) PERCENTAGE
1. Presence of Utilities 20%
2. Orientation 10%
3. Size/ Shape 10%
The table shown above has a total of 100% suitable site result if all the requirements will be achieved. This
criterion must be followed for the proposed project development to be more effective moreover, to function
well on its existing community and environment.
SITE SELECTION
o SITE 1: Site near UP Town Center
o The first proposed site is in UP Town Center located along Katipunan Avenue, Quezon
City. UP Town Center is a mixed-use development project between University of the
Philippines Diliman and Ayala Land.It sits on land formerly occupied by the UP Integrated
School (UPIS). Strategically located, it offers different opportunities in rentals, commercial
and business activities because of the many benefits of the UP Town Center.The site is
near the UP Diliman, Ateneo and Miriam College Campuses. It is also accessible to
Katipunan LRT Station, and other public transportations. The site has a vibrant vibe
because it sits in a mixed use development. The users, primarily students will be able to
engage to different social activities while living near their respective campuses.
Map of Site near UP Town Center
o SITE 2: Site near Trinoma Mall
The second proposed site is located near the Trinoma Mall along Edsa, Quezon City. A
busy place with Trinoma, SM North, Eton Centris near the site offers a great place for
building a high rise office tower. Accessibility to commercial and business areas offers
great economic opportunities.
Map of site near Trinoma Mall
After discussing all the possible sites, the researcher came up with a tabulation of ratings with its
corresponding ranking system for the Site Selection Criteria. The table below will give the summary on
which site will be chosen for the proposed development.
Rating Guide:
5 - Highly Preferable/ Desirable
4 - Very Preferable/ Desirable
3 - Preferable/ Desirable
2 - Satisfactory/ Fair
1 - Poor
CRITERIA WEIGHT
Site 1
(Near U.P Town Center)
Site 2
(Near Trinoma Quezon City)
Ratings Points Ratings Points
Major Criteria 60%
1. Availability of Needs 20% 5 1 3 0.75
2. Zoning/ Land Use Plan 15% 4 0.6 3 0.45
3. Accessibility 15% 5 0.75 4 0.4
4. Physical Suitability 10% 4 0.4 4 0.4
Minor Criteria 40%
5. Presence of Utilities 20% 4 0.8 3 0.6
6. Orientation 10% 4 0.8 3 0.3
7. Size/ Shape 10% 3 0.3 3 0.3
TOTAL
c. FUNCTIONAL SITE SELECTION
4.1.1.2 SITE JUSTIFICATION
The proposed site is 3000 sq. m. in terms of total land area. It is owned by private company
named Ayala Land allotted for a high rise mixed used development.
The site has conformed to the major criteria for site selection of a mix used high rise such as:
Availability of utilities and basic services
Conformity with the Zoning Ordinance or Land Use Plan of the City/Municipality
Physical Suitability and Accessibility
Proximity to the economic opportunities
4.1.2 SITE DATA
4.1.2.1 MACRO SITE DATA
1.2.1.2 Climatological Condition
1.2.1.3 The climate in Quezon City is typical of Metro Manila’s, which has a distinct dry
season from December to April and wet season from May to November. The
normal annual rainfall total is 2,532.3 mm with the maximum mean monthly total
rains being experienced in August with 526.8 mm and the minimum in February
with 8.9 mm. The maximum number of 24-rainy days occurs in August while the
minimum of two-rainy days occurs in February. The annual total number of rainy
days is 153 while the average temperature is lowest at 20.4° C in January and