7 7 Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield and external jacket in polyethylene type moisture barrier. Construction Conductor Soft copper wires Insulation Foam skin or solid high density polyethylene. Twisted Pairs Insulated conductors are twisted into pairs Core Assembly Up to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs, from 400 pairs and more, units of 100 pairs (each unit is conformed by 4 groups of 25 pairs) Spare pairs One spare pair white-red colored at the interstices of each 100 pairs unit, to guarantee nominal numbers of pairs. Identification Pairs, groups and units that conform the core, are identified by color code (Attached) Core Wrap Non-hygroscopic dielectric tape. Offers dielectric strength between core and sheath Shield Corrugated Aluminum tape both sides covered with copolymer Jacket Black polyethylene, abrasion, weather, and penetration to water resistant Outside Telephone Cable Filled Core. Moisture Barrier.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
77
Description
Soft copper wires insulated with high density polyethylene, foam skin or solid.Filled core, conformed by groups of pairs or by unit of groups of pairs. Aluminumshield and external jacket in polyethylene type moisture barrier.
Construction
ConductorSoft copper wires
InsulationFoam skin or solid high density polyethylene.
Twisted PairsInsulated conductors are twisted into pairs
Core AssemblyUp to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs,from 400 pairs and more, units of 100 pairs (each unit is conformed by 4 groupsof 25 pairs)
Spare pairsOne spare pair white-red colored at the interstices of each 100 pairs unit, toguarantee nominal numbers of pairs.
IdentificationPairs, groups and units that conform the core, are identified by color code(Attached)
Core WrapNon-hygroscopic dielectric tape. Offers dielectric strength between core andsheath
ShieldCorrugated Aluminum tape both sides covered with copolymer
JacketBlack polyethylene, abrasion, weather, and penetration to water resistant
Moisture BarrierFilled Core with elastomeric compound, aluminum tape both sidescovered with copolymer and polyethylene external jacket, firmly bondedto external side of aluminum tape
OptionsManufacturing according to REA and/or Bellcore specificationsShield in Flat Aluminum tape. Armor in corrugated and copolymercovered Steel tape for direct buried and for rodent protection. Galvanizedsteel wires armor for vertical installations. Other Core Assemblies areavailable upon request.
ApplicationsTrunk cable and distribution cable networks. Special for wet locations;the elastomeric compound filler prevents the entrance of moisture tothe core. Installation in ducts or raceways; for buried direct in locationswithout heavy traffic.
CENTELSA Outside Telephone Cable, are able for voice and datatransmission up to 6.3 MHz, optimizing the bandwidth of copper cables.
Standards and Specifications
CENTELSA Outside Telephone Cable, are manufactured under thefollowing standards:
Soft copper wires insulated with high density polyethylene, foam skin or solid.Core conformed by groups of pairs or by unit of groups of pairs. Filled coreAluminum shield and double Jacket (inner and outer) in polyethylene typemoisture barrier.
Construction
ConductorSoft copper wires
InsulationFoam skin or solid high density polyethylene.
Twisted PairsInsulated conductors are twisted into pairs
Core AssemblyUp to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs,from 400 pairs and more, units of 100 pairs (each unit is conformed by 4 groupsof 25 pairs)
Spare pairsOne spare pair white-red colored at the interstices of each 100 pairs unit, toguarantee nominal numbers of pairs.
IdentificationPairs, groups and units that conform the core, are identified by color code(Attached)
Inner JacketBlack polyethylene, abrasion, weather, and penetration to water resistant
Filled Core. Double Jacket. Moisture Barrier.
12
Core WrapNon-hygroscopic dielectric tape. Offers dielectric strength betweencore and sheath
ShieldCorrugated Aluminum tape both sides covered with copolymer
Outer JacketBlack polyethylene, abrasion, weather, and penetration to waterresistant
Moisture BarrierFilled Core with elastomeric compound, inner polyethylene jacket,aluminum tape both sides covered with copolymer and outerpolyethylene external jacket, firmly bonded to external side of aluminumtape.
Options
Manufacturing according to REA and/or Bellcore specificationsShield in Flat Aluminum tape. Armor in corrugated and copolymercovered Steel tape for direct buried and for rodent protection. Galvanizedsteel wires armor for vertical installations. Other Core Assemblies areavailable upon request.
Applications
Trunk cable and distribution cable networks. Special for wet locations;the elastomeric compound filler prevents the entrance of moisture tothe core.
Trunk cable and distribution cable networks. Special for wet locations;the elastomeric compound filler prevents the entrance of moisture tothe core.
The inner jacket offers additional blocking to the entrance of humidityto the core, increases the dielectric strength pair-shield and improvescable resistance to penetration of sharp objects.
CENTELSA Outside Telephone Cable, are able for voice and datatransmission up to 6.3 MHz, optimizing the bandwidth of copper cables.
13
Standards and Specifications
CENTELSA Outside Telephone Cable, are manufactured under the followingstandards:
Standards:ANSI/ICEA S-84-608 Telecommunications cable filled, polyolefin insulatedcopper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefininsulated and covered, filled and dry.
Certifications
CENTELSA Outside Telephone Cable, are certified by:ICONTEC (Colombia). Standard NTC 2061.
Note: Other configurations, sizes, colors and length not specified herein areavailable upon request.
Soft copper wires insulated with high density polyethylene, foam skin or solid. Aircore, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield andexternal jacket in polyethylene type moisture barrier.
Construction
ConductorSoft copper wires
InsulationFoam skin or solid high density polyethylene.
Twisted PairsInsulated conductors are twisted into pairs
Core AssemblyUp to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs, from 400pairs and more, units of 100 pairs (each unit is conformed by 4 groups of 25 pairs)
Spare pairsOne spare pair white-red colored at the interstices of each 100 pairs unit, to guaranteenominal numbers of pairs.
IdentificationPairs, groups and units that conform the core, are identified by color code (Attached)
Core WrapNon-hygroscopic dielectric tape. Offers dielectric strength between core and sheath
ShieldCorrugated Aluminum tape both sides covered with copolymer
JacketBlack polyethylene, abrasion, weather, and penetration to water resistant
Air Core. Moisture Barrier.
16
Moisture BarrierFilled Core with elastomeric compound, aluminum tape both sides coveredwith copolymer and polyethylene external jacket, firmly bonded to externalside of aluminum tape
Options
Manufacturing according to REA and/or Bellcore specificationsShield in Flat Aluminum tape. Armor in corrugated and copolymer coveredSteel tape for direct buried and for rodent protection. Galvanized steel wiresarmor for vertical installations. Other Core Assemblies are available uponrequest.
Applications
Trunk cable and distribution cable networks. For use in pressurized networks.Installation in ducts or raceways
CENTELSA Outside Telephone Cable, are able for voice and data transmissionup to 6.3 MHz, optimizing the bandwidth of copper cables.
Standards and SpecificationsCENTELSA Outside Telephone Cable, are manufactured under the followingstandards:
ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulatedcopper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefininsulated and covered, filled and dry.
Certifications
CENTELSA Outside Telephone Cable, are certified by:ICONTEC (Colombia). Standard NTC 2061.
Note: Other configurations, sizes, colors and length not specified hereinare available upon request.
17
Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
Soft copper wires insulated with high density polyethylene, foam skin or solid. Aircore, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield,support messenger and external jacket in polyethylene type moisture barrier.
Construction
ConductorSoft copper wires
InsulationFoam skin or solid high density polyethylene.
Twisted PairsInsulated conductors are twisted into pairs
Core AssemblyUp to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs, from 400pairs and more, units of 100 pairs (each unit is conformed by 4 groups of 25 pairs)
Spare pairsOne spare pair white-red colored at the interstices of each 100 pairs unit, to guaranteenominal numbers of pairs.
IdentificationPairs, groups and units that conform the core, are identified by color code (Attached)
Core WrapNon-hygroscopic dielectric tape. Offers dielectric strength between core and sheath
ShieldCorrugated Aluminum tape both sides covered with copolymer
Support Messenger7 Strand high strength galvanized steel wire.
JacketBlack polyethylene, abrasion, weather, and penetration to water resistant
Outside Telephone CableSelf-supportedFigure 8. Air Core. Moisture Barrier.
20
Moisture BarrierAir Core (for pressurerd systems) with elastomeric compound, aluminumflat tape both sides covered with copolymer and polyethylene external jacket,firmly bonded to external side of aluminum tape
Options
Manufacturing according to REA and/or Bellcore specificationsShield in corrugated Aluminum tape. Filled Core. Galvanized steel wiresfully flooded for corrosion protection. Other Core Assemblies are availableupon request.
Applications
For pressured systems overhead trunk cable and distribution cable networks.Aerial installation suspended from Messenger
CENTELSA Outside Telephone Cable, are able for voice and data transmissionup to 6.3 MHz, optimizing the bandwidth of copper cables.
Standards and Specifications
CENTELSA Outside Telephone Cable Figure 8, are manufactured under thefollowing standards:
ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulatedcopper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefininsulated and covered, filled and dry.
Certifications
CENTELSA Outside Telephone Cable, are certified by:ICONTEC (Colombia). Standard NTC 2061.
Note: Other configurations, sizes, colors and length not specified hereinare available upon request.
21
Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
8.03 x 18.67 9.71 x 20.3511.00 x 21.6412.08 x 22.7213.04 x 23.6814.70 x 25.3416.86 x 27.5020.19 x 32.1522.61 x 34.5726.70 x 38.66 8.88 x 19.5210.90 x 21.5412.46 x 23.1013.77 x 24.4114.93 x 25.5716.93 x 27.5719.54 x 31.5023.48 x 35.4426.39 x 38.3531.34 x 43.30
8.03 x 18.67 9.71 x 20.3511.00 x 21.6412.08 x 22.7213.04 x 23.6814.70 x 25.3416.86 x 27.5020.19 x 32.1522.61 x 34.5726.70 x 38.66 9.10 x 19.7411.22 x 21.8612.85 x 23.4914.22 x 24.8615.43 x 26.0717.52 x 28.1620.25 x 32.2124.35 x 36.3127.40 x 39.3632.57 x 44.53
Drop Wire Paralleled. Hard copper conductors or steel copper covered,polyethylene or PVC insulated.
Construction
ConductorHard copper or steel copper covered (CCS)
InsulationSingle layer Polyethylene for DWP-PE and insulation – jacket integral for DWP-2PE, weather resistant.Polyethylene Insulation and PVC jacket for DWP PE-PVC.Flame retardant PVC for DWP-PVC.Paralleled conductors with polarization ridge and conductor separator membrane.
Application
Self supporting one pair parallel conductor Drop Wire intended for aerial serviceconnection to the subscriber
Standards
CENTELSA telephone wires DWP are manufactured under the followingstandards:NTC 1300 Service Drop telephone wire, inside installations and jumper.
Certifications
CENTELSA Outside Telephone Wire, are certified by:CIDET (Colombia). Standard NTC 1300.
Package100 or 200 meters spools in corrugated carton boxes
Note: other configurations and sizes not specified in this catalogue are availableupon request.
Outside TelephoneWire DWPDrop Wire Paralell
24
Outside Telephone Wire (International System Unit)Drop Wire Parallel
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
Outside Telephone Wire (International System Unit)Drop Wire Parallel
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
0.800.80
0.80
0.800.801.50
MATERIALAISLAMIENTO
Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Hard cooper and 33.91 ohm-cmil/ft for steel copper covered.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
Hard CopperHard Copper
CopperClad Steel
CopperClad Steel
Hard CopperHard CopperHard CopperHard CopperHard Copper
2 x 18
DWP PVC
APPROX.TOTAL
WEIGTH(kg/km)
INSULATIONMATERIAL
EXTERNALDIMENSIONS
(mm)
DCRESISTANCE
AT 20° C1
(ohm/km)
INSULATIONRESISTANCE
(Mohm-km)TYPE CONDUCTOR
CROSSSECTION
(mm2)
INSULATIONTHICKNESS
(mm)
ONECONDUCTOR
TENSILE STRENGTH(Nominal)
(MPa)
JACKETTHICKNESS
(mm)SIZE
No. x AWG
SEPARATOR(mm)
STRANDDIAMETER
(mm)
DWP PE CCS
DWP PVC CCS
2 x 182 x 20
2 x 18
2 x 182 x 20
DWP PE
2 x 182 x 182 x 20
DWP 2PE
DWP PE-PVC
2 x 18
2 x 182 x 20
2 x 18
2 x 182 x 202 x 182 x 182 x 20
1.02
1.020.81
1.02
1.020.811.021.020.81
0.82
0.820.52
0.82
0.820.520.820.820.52
PE
PVCPVC
PVC
PEPEPEPEPE
0.80
0.800.80
0.80
0.800.801.600.700.70
1.00
1.001.00
1.00
1.001.00
---
-
--
-
---
0.800.80
2.62 x 6.25
2.62 x6.252.41 x 5.83
2.62 x 6.25
2.62 x 6.252.41 x 5.834.22 x 7.174.02 x 8.053.81 x 7.63
23
2922
28
2418364940
72.6
22.235.2
72.6
22.235.222.222.235.2
6229
249288
249
622972027167
362409
875
460473
875
460473460460473
Notas: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Hard cooper and 58.62 ohm-mm2/km for steel copper covered.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
Hard CopperHard Copper
CopperClad Steel
CopperClad Steel
Hard CopperHard CopperHard CopperHard CopperHard Copper
2 x 18
DWP PVC
APPROX.TOTAL
WEIGTH(pound/kft)
INSULATIONMATERIAL
EXTERNALDIMENSIONS
(mils)
DCRESISTANCE
AT 20° C1
(ohm/kft)
INSULATIONRESISTANCE
(Mohm/kft)TYPE CONDUCTOR
CROSSSECTION
(kcmil)
INSULATIONTHICKNESS
(mils)
ONECONDUCTOR
TENSILE STRENGTH(Nominal)
(ksi)
JACKETTHICKNESS
(mils)SIZE
No. x AWG
SEPARATOR(mils)
STRANDDIAMETER
(mils)
DWP PE CCS
DWP PVC CCS
2 x 182 x 20
2 x 18
2 x 182 x 20
DWP PE
2 x 182 x 182 x 20
DWP 2PE
DWP PE-PVC
2 x 18
2 x 182 x 20
2 x 18
2 x 182 x 202 x 182 x 182 x 20
40
4032
40
4032404032
1.63
1.631.02
1.63
1.631.021.631.631.02
PE
PVCPVC
PVC
PEPEPEPEPE
31
3131
31
3131632828
39
3939
39
3939---
-
--
-
---
3131
103 x 246
103 x 24695 x 229
103 x 246
103 x 24695 x 229
166 x 282158 x 317150 x 300
15
2015
19
1612253327
22.1
6.7710.7
22.1
6.7710.76.776.7710.7
6229
817944
817
204372362823514
11881342
875
6769
127
6769676769
25
Outside TelephoneWire DWTDrop Wire Twisted
Description
Drop Wire Twisted. Hard copper conductor, individually insulated with polyethyleneor PVC.
Construction
ConductorHard copper
InsulationBlack Polyethylene weather resistant or flame retardat PVC.
Application
Self supporting one pair twisted conductor Drop Wire intended for aerial serviceconnection to the subscriber
Standards
CENTELSA telephone wires DWT are manufactured under the following standards:NTC 1300 Service Drop telephone wire, inside installations and jumper.
Certifications
CENTELSA Outside Telephone Wire, are certified by:CIDET (Colombia). Standard NTC 1300.
Package100 or 200 meters spools in corrugated carton boxes
Note: other configurations and sizes not specified in this catalogue are availableupon request.
26
Outside Telephone Wire (International System Unit)Drop Wire Twisted
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
0.820.520.820.52
2 x 182 x 202 x 182 x 20
DWT PVCDWT PVCDWT PEDWT PE
1.020.811.020.81
249288
62297202
22.735.922.735.9
28212317
460473460473
0.800.800.800.80
2.622.412.622.41
5.254.835.254.83
APPROX.TOTAL
WEIGTH(kg/km)
CROSSSECTION
(mm2)
EXTERNALDIAMETER
(mm)
DCRESISTANT
AT 20°C1
(ohm/km)
INSULATIONRESISTANCE
(Mohm-km)
TYPE SIZENo. x AWG
STRANDDIAMETER
(mm)
ONE CONDUCTORTENSILE STRENGTH
(Nominal)(MPa)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Hard cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
Outside Telephone WireDrop Wire Twisted
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
1.631.021.631.02
2 x 182 x 202 x 182 x 20
DWT PVCDWT PVCDWT PEDWT PE
40324032
817944
2043723628
6.9011.06.9011.0
19141611
67696769
31313131
10395
10395
207190207190
APPROX.TOTAL
WEIGTH(pound/kft)
CROSSSECTION
(kcmil)
EXTERNALDIAMETER
(mils)
DCRESISTANT
AT 20°C1
(ohm/kft)
INSULATIONRESISTANCE
(Mohm-kft)
TYPE SIZENo. x AWG
STRANDDIAMETER
(mils)
ONE CONDUCTORTENSILE STRENGTH
(Nominal)(ksi)
INSULATIONTHICKNESS
(mils)
SEPARATOR(mils)
Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Hard cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
27
Description
Soft copper wires insulated with flame retardant PVC, paired, unshielded or shieldedwith aluminum foil and drain wire, external PVC jacket.
Construction
ConductorSoft copper
InsulationFlame retardant PVC
PairsTwo insulated conductor twisted together
CoreUp to 25 pairs one group of pairs, for 30 pairs and more, groups of 10 or 25 pairs.
Spare pairsOne pair color coded White-Red for 10 pairs or more.
IdentificationPairs, groups an units in the assembly core, are identified by color code (includedin this catalogue)
Core WrapNon hygroscopic polyester tape
ShieldUnshielded or shielded with aluminum foil and tinned copper drain wire
JacketFlame retardant PVC, gray colored.
Characteristics
Mutual capacitance120 nF/km.Capacitive Unbalance400 pF (referred to 500 m).
Inside Telephone Cables
28
DC Conductor Resistance97.8 ohm/km.
Maximum Operating Voltage60 V.
Insulation Resistance500 Mohm-km.
Dielectric Strength (60 seg)1000 V AC, 1500 V DC.
Applications
For inside residential commercial and industrial applications. Appropriatefor locations with electric interference produced by near power electric circuit.
Installation in dry locations in ducts trays and race ways.
Standards
CENTELSA Inside Cables are manufactured under the following standards:
NTC-983, IEC 189. Cables e hilos para bajas frecuencias con aislamientoy cubierta en PVC.
Notes: 1. Optionally with tinned copper conductor2. Other configurations and sizes not specified in this catalogue are available upon request.
29
Note: Data herein indicated are approximate and are subject to normal manufacturing tolerances.
Inside Unshielded Telephone Cable
Standards: Low Frecuency Cables and Wire with PVC Insulation and PVC Sheat.
Twisted pair for cross connections, for inside use. Soft tinned copper insulatedwith PVC or PVC and Nylon, assembly in pairs, triads or quads.
Construction
ConductorSoft tinned copper wire
InsulationFlame retardant PVC for JWT.Flame retardant PVC insulation; abrasion oil and gasoline resistant Nylonjacket for JWT PVC-NY.
Applications
JWT: twisted telephone wire for inside use, cross connections, telephonicderivations and radio and TV equipment wiring.
JWT PVC-NY: connection wire in distributors, mini-distributors and telephonicequipment. Nylon jacket provides abrasion resistance.
JWT NY: connection wire in distributors, mini-distributors and telephonicequipment.
Radio and TV equipment wiring, weld able without remove the insulation,Diameter reduced tightness and low friction advantages given by Nyloninsulation. Installation in dry locations, ducts or open installation.
Standards
CENTELSA telephone wires JWT are manufactured under the followingstandards:NTC 1300 Service Drop telephone wire, inside installations and jumper.
Inside TelephoneWire JWTJumper Wire Twisted
31
CertificationsCENTELSA Outside Telephone Wire, are certified by:CIDET (Colombia). Standard NTC 1300.
Package100 or 200 meters spools in corrugated carton boxes
Note: other configurations and sizes not specified in this catalogue are availableupon request.
Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
Inside Telephone Wire JWT PVC(International System Units)Jumper Wire Twisted PVC
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
0.320.320.320.210.210.210.280.280.280.200.200.20
2 x 223 x 224 x 222 x 243 x 244 x 242 x 0.63 x 0.64 x 0.62 x 0.53 x 0.54 x 0.5
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
0.250.400.64
2 x 262 x 242 x 22
15.920.125.3
126108
91
44.427.717.5
2.63.75.3
4.34.34.3
38.042.247.4
75.984.394.7
6.76.76.7
29.333.538.7
Inside Telephone Wire JWT PVC-NY(International System Units)Jumper Wire Twisted PVC-Nylon
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
Standards: NTC 1300 Service Drop telephone wire, inside installations andjumper.
Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
0.640.640.640.400.400.40
2 x 223 x 224 x 222 x 243 x 244 x 24
252525202020
572572572592592592
17.517.517.527.727.727.7
5.78.5
11.33.65.57.3
11.811.811.89.89.89.8
48.948.948.939.839.839.8
97.9105.5118.179.685.896.1
SIZEAWG or mm
DCRESISTANCE
AT 20° C¹(ohm/kft)
INSULATIONTHICKNESS
(mils)
APPROX.TOTAL WEIGTH
(pound/kft)
OVERALLDIAMETER
(mils)
STRANDDIAMETER
(mils)
CROSSSECTION(sq inches)
EXTERNALDIAMETER
(mils)
INSULATIONRESISTANCE
(Mohm/kft)
APPROX.TOTAL
WEIGTH(kg/km)
CROSSSECTION(sq inches)
EXTERNALDIAMETER
(mils)
DCRESISTANCE
AT 20°C1
(ohm/km)
INSULATIONRESISTANCE
(Mohm-km)
SIZEAWG or mm
STRANDDIAMETER
(mils)
JACKETTHICKNESS
(mils)
DIAMETEROVER JACKET
(mils)
NSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
33
Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
Inside Telephone Wire JWT NY(International System Units)Jumper Wire Twisted PVC-Nylon
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
0.250.400.64
2 x 262 x 242 x 22
15.920.125.3
333333
44.427.717.5
2.03.04.6
6.76.76.7
29.333.538.7
58.672.293.4
SIZEAWG or mm
DCRESISTANCE
AT 20° C¹(ohm/km)
INSULATIONTHICKNESS
(mm)
APPROX.TOTAL WEIGTH
(kg/km)
DIAMETEROVER
INSULATION(mm)
STRANDDIAMETER
(mm)
CROSSSECTION
(mm²)
EXTERNALDIAMETER
(mm)
INSULATIONRESISTANCE
(Mohm/km)
SIZEAWG or mm
DCRESISTANCE
AT 20° C¹(ohm/kft)
INSULATIONTHICKNESS
(mils)
APPROX.TOTAL WEIGTH
(pound/kft)
DIAMETEROVER
INSULATION(mils)
STRANDDIAMETER
(mils)
CROSSSECTION(sq inches)
EXTERNALDIAMETER
(mils)
INSULATIONRESISTANCE
(Mohm/kft)
34
Description
Inside drop wire paralleled. Soft copper insulated with PVC.
Construction
ConductorSoft copper wire
InsulationFlame retardant white PVC, paralleled conductors with polarization ridge.
Applications
Paralleled telephone wire for inside use from the interior box to exterior box;telephonic derivations.
Installation in dry locations, ducts or open installation.
Standards
CENTELSA telephone wires JWP are manufactured under the followingstandards:NTC 1300 Service Drop telephone wire, inside installations and jumper.
Certifications
CENTELSA Outside Telephone Wire, are certified by:CIDET (Colombia). Standard NTC 1300.
Package100 or 200 meters spools in corrugated carton boxes
Note: other configurations and sizes not specified in this catalogue areavailable upon request.
Inside TelephoneWire JWPJumper Wire Parallel
35
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for Soft cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
Inside Telephone Wire JWP(International System Units)Jumper Wire Parallel
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
0.520.32
2 x 202 x 22
0.810.64
240279
33.954.2
18.113.5
0.600.60
2.01 x 4.031.84 x 3.69
Notes: 1. DC resistance calculated based on a 10.371 ohm-cmil/ft resistivity for Soft cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
1.020.64
2 x 202 x 22
32.025.3
787914
10.316.5
12.29.1
23.623.6
79.3 x 158.572.6 x 145.1
Inside Telephone Wire JWPJumper Wire Parallel
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
SIZEAWG or mm
DCRESISTANCE
AT 20° C¹(ohm/km)
INSULATIONTHICKNESS
(mm)
APPROX.TOTAL WEIGTH
(kg/km)
STRANDDIAMETER
(mm)
CROSSSECTION
(mm²)
EXTERNALDIAMETER
(mm)
INSULATIONRESISTANCE
(Mohm/km)
SIZEAWG or mm
DCRESISTANCE
AT 20° C¹(ohm/kft)
INSULATIONTHICKNESS
(mils)
APPROX.TOTAL WEIGTH
(pound/kft)
STRANDDIAMETER
(mm)
CROSSSECTION
(kcmil)
EXTERNALDIAMETER
(mils)
INSULATIONRESISTANCE
(Mohm/kft)
34
Description
Inside drop wire paralleled. Soft copper insulated with PVC.
Construction
ConductorSoft copper wire
InsulationFlame retardant white PVC, paralleled conductors with polarization ridge.
Applications
Paralleled telephone wire for inside use from the interior box to exterior box;telephonic derivations.
Installation in dry locations, ducts or open installation.
Standards
CENTELSA telephone wires JWP are manufactured under the followingstandards:NTC 1300 Service Drop telephone wire, inside installations and jumper.
Certifications
CENTELSA Outside Telephone Wire, are certified by:CIDET (Colombia). Standard NTC 1300.
Package100 or 200 meters spools in corrugated carton boxes
Note: other configurations and sizes not specified in this catalogue areavailable upon request.
Inside TelephoneWire JWPJumper Wire Parallel
35
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for Soft cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
Inside Telephone Wire JWP(International System Units)Jumper Wire Parallel
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
0.520.32
2 x 202 x 22
0.810.64
240279
33.954.2
18.113.5
0.600.60
2.01 x 4.031.84 x 3.69
Notes: 1. DC resistance calculated based on a 10.371 ohm-cmil/ft resistivity for Soft cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.
1.020.64
2 x 202 x 22
32.025.3
787914
10.316.5
12.29.1
23.623.6
79.3 x 158.572.6 x 145.1
Inside Telephone Wire JWPJumper Wire Parallel
Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.
1 to 100101 to 200201 to 300301 to 400401 to 500501 to 600601 to 700701 to 800801 to 900
901 to 10001001 to 11001101 to 12001201 to 13001301 to 14001401 to 15001501 to 16001601 to 17001701 to 18001801 to 19001901 to 20002001 to 21002101 to 22002201 to 23002301 to 2400