112.6 m² 06:0/001 6th Form Study Room 48.8 m² 06:0/002 6th Form Common Room 51.4 m² 06:0/003 6th Form Common Room 44.2 m² 01:0/053 6th Form Common Room 8.0 m² 01:0/051 Office 68.6 m² 01:0/045 ICT Classroom 22.5 m² 01:0/046 Yr 7,8,9 Learning Coach Provision 14.1 m² 01:0/048 Circ. 28.7 m² 03:0/001 Circ. 12.4 m² 03:0/004 Bar Store 7.6 m² 03:0/038 Office 4.1 m² 03:0/006 Snack Bar 3.8 m² 03:0/007 Store 40.5 m² 01:0/044 Circ. New Fire Escape access to proposed carpark Additional 2 no. accessible parking bays provided within existing carpark adjacent to the main entrance of the school Outer red brick work skin added to match existing adjacent building New insulated roller shutter door Existing Vehicle Access from Stryt Isa 35 no. parking spaces- refer to Landscape drawings 35.2 m² 03:0/005A Nurture Classroom 18.4 m² 03:0/035 Boys W.C. 55.0 m² 03:0/003 Circ. Gender Neutral WCs_01 Gender Neutral WCs_02 Area shown within dotted blue boundary will need to be fire rated- including existing door into 6th Form Study Room- fire officer to confirm Caretaker Store Zone 01 Demolition & Proposed Carpark Zone 02 proposed new build Zone 03 Refurbishment Rev. Drawn Title Project Drawing number Rev. Revision description Checked Date VISUAL SCALE 1:100 @ A1 2m 8m 6m 4m 0m Lovelock Mitchell Architects 3 Stanley Street, Chester, CH1 2LS Tel +44 (0) 1244 404321 e-mail: [email protected] web: www.lovelockmitchell.com Notes Figured dimensions are to be used in all case. Dimensions should not be scaled from drawing All existing dimensions should be checked on site before commencement of the work. Any discrepancies in dimensions should be clarified with the Architect prior to commencement of the work. No deviation from this drawing will be permitted without the prior written consent of the Architect. This drawing is to be read in conjunction with all the relevant Mechanical and Electrical drawings. This drawing is to be read in conjunction with the relevant Structural Engineer's drawings, structural calculations and recommendations. This drawing is to be read in conjunction with the relevant Fire Safety Strategy drawings This drawing is copyright and to be returned to the architect on completion of the contract. LMA Project A1 P3 C:\Revit_Local\CAS-LMA-02-XX-M3-A-0001_Model_Building_Existing_Evie.greenallKL9T3.rvt Castell Alun School Fagl Ln, Hope, Wrexham, LL12 9PY GA_Plan_00Ground_Zone01_Proposed 1590 CAS-LMA-02-00-DR-A-2011 P1 Planning Issue EG TR 19-12-06 P2 General Updates Inline with Stage04 Pricing Info Issue EG TR 19-12-23 P3 Amended Planning Issue EG TR 20-05-01 Scale: 1 : 100 GA_Plan_00Ground_Zone01_Proposed 1 Key Plan_Zoning NOTE For landscaping proposals refer to drawings: Zone 01 CAH-LST-XX-XX-M3-L-2000 Zone 02 CAH-LST-XX-XX-M3-L-2001 N