Fiber Network Monitoring and ManagementStandalone Solution (Fiber Guardian)
1610 nm port
Unique Features
Active Alarm Management View - Show system status at the NOC - Assign trouble tickets - Automatic ticket escalation
OSPInSight® – SpliceGUI - Add/modify and manage splice points
with this graphical tool
reports
with full alarm details
100 % Web-Based Solution - Only two clicks to provision new test
routes via web - Render OTDR on any port - Easy to setup and schedule fi ber tests - Four states of alert: new, still there,
changed, cleared
NMS Integration - Integration to unify alert views at the
NOC via SNMP and web services - Integration with a third-party GIS
application to show fault-location alerts
OSPInSight® – Web - View alarms and inventory reports
OSPInSight®-Edit - Create and maintain the OSP inventory - View capability
Watersensor Dedicated water sensor that will alert the user when a splice enclosure fi lls with water
Detect bend events with stable high-refl ectance peak
OSPInSight®-Edit - Create and maintain the OSP inventory - View capability
Executive Dashboard Create customs reports such as: - Fiber availability (%) - MTTR trend (hours) - Fault distribution (counts) - TTR distribution (counts per category) Per region, RTU or route and over time
Bidirectional SMS Communication - Receive alarms - Initiate test on demand ports - Skip/activate port monitoring - Renew reference traces
SmartPhone app: - Go to RTU web GUI for detailed
information
Section attenuation trend report
Disconnect and re-connect event
Visual and Sound Alarms.
Bidirectional SNMP - Detect rapidly if the fault is in the fi ber or
telecom equipment - Initiate test on demand ports - Skip/activate port monitoring - Renew reference traces
The Learning Phase - Optimized automatic thresholds applied to entire monitored link - Attenuation changes resulting from seasonal variations and environment
are considered - No false alarms due to misconfi gured thresholds
Automatic Baseline to Isolate and Locate
Create Trend Reports - Make proactive planning decisions,
recognize trends and identify potential problems before they affect business- critical services
- Detect cable failures early with attenuation reports for whole link, sections and events
Create and Schedule Reports - Fault alarms - Audit logs (changes by user to
the system) - Alarm lifecycles - Affected customers - Alarm duration
Mobile Access
Fault-on-Map and Outside Plant Inventory Solution
NQMSfi ber with OSPinSight – Architecture
Fault-on-Map and Outside Plant Inventory Solution Fiber Guardian with OSPInSight – Architecture
Full System Power in a Single Test Unit Fiber Guardian – Architecture
Fiber Test InSight - Draw and monitor - Create fi ber routes and correlate geographical
and optical distance based on OTDR information - Free internet maps - Export route details to other systems - Email with fault coordinates and Google Maps Link
Add a termination pointAdd a splice point Add a slack point
Fault-on-Map Web Application Fiber Guardian with Fiber Test InSight – Architecture
Long-Haul Dark Fiber Monitoring Coverage up to 265 km (165 miles) with extended range capability
Management - Certify FTTx construction - Standardize fi ber-network infrastructure acceptance tests
among multiple contractors - Reduce OPEX/CAPEX and improve network quality - Confi rm new suscriber connections with service activation
Monitoring - E2E loss at 1650 nm - Fault isolation and location after the splitter - Demarking at customer premises with HRD fi lter - Faster root-cause identifi cation
Central Diagnosis in FTTx FG-750 Node iOLM
Centralized Server Solution (NQMSfi ber)
NMS and GIS Integration Solution Fiber Guardian with Third-Party Integration – Architecture
Regional Topology View Global Status View - Drill down from Global view
to Regional view - Determine user access per region - Manage user preferences and profi les - Get alarms based on schedule - Display affected customer(s)
Watersensor Dedicated water sensor that will alert the user when a splice enclosure fi lls with water
200 km (125 miles)
E
Monitoring
Pr ov
is io
ni ng
EXFO CORPORATE HEADQUARTERS 400 Godin Avenue Quebec City, Quebec G1M 2K2 CANADA Tel.: +1 418 683-0211 Fax: +1 418 683-2170
EXFO America 3400 Waterview Parkway, Suite 100 Richardson, TX 75080 USA Tel.: +1 972 761-9271 Fax: +1 972 761-9067
EXFO Asia 100 Beach Road, #22-01/03 Shaw Tower SINGAPORE 189702 Tel.: +65 6333 8241 Fax: +65 6333 8242
EXFO China 36 North, 3rd Ring Road East, Dongcheng District Room 1207, Tower C, Global Trade Center Beijing 100013 P.R. CHINA Tel.: + 86 10 5825 7755 Fax: +86 10 5825 7722
EXFO Europe Ltd. Winchester House School Lane, Chandlers Ford SO53 4DG UK Tel.: +44 2380 246810 Fax: +44 2380 246801
EXFO Finland Elektroniikkatie 2 FI-90590 Oulu, FINLAND Tel.: +358 (0)403 010 300 Fax: +358 (0)8 564 5203
EXFO Service Assurance 270 Billerica Road Chelmsford, MA 01824 USA Tel.: +1 978 367-5600 Fax: +1 978 367-5700
© 2013 EXFO Inc. All rights reserved. Printed in Canada 13/12 20130201V2 SAP1065027
Fiber Network Monitoring and Management
TECHNICAL POSTER