Festo Tecsup DGP
Force sensor
FP 1130
Measuring range: 0 200 N Measuring error: 1 % of full-scale
value Sensitivity (nominal): 1 mV/V Overload: 130 % of measuring
range Breaking load: 200 % of measuring range Distance moved under
nominal load (calibration in pressure direction): 0.1 mm
max. Bridge resistance (full bridge): 350 (nominal) Supply
voltage, permissible: 3 10 V AC/DC
Motor controller
-
Festo Tecsup DGP
FP 1120
Motor output: 20 V DC/300 mA Remote input: 10 V DC Position
input: 0 24 V DC Proximity sensor inputs: 24 V DC/30 mA Positioning
accuracy: 5 %
Measuring bridge amplifier
FP 1130
Power consumption: 50 mA Complementary resistors: 350 Bridge
supply voltage: 5 V DC Amplifier input range: 10 mV Amplifier
output range: 5 V Amplification: Approx. 500
Non-contact inductive-magnetic proximity sensor
-
Festo Tecsup DGP
FP 1120
For mounting on the slide unit (Order no. 080824). Including
cable.
Power supply: 10 30 V DC Switching capacity: 6 W Overcurrent
trip: Min. 250 mA Switching accuracy: 0.1mm
Pneumatic-electrical converter
TP 201, BIBB-EP, FP 1130 (until 2004)
The pneumatic-electrical converter can fulfill 3 functions:
Pressure switch, vacuum switch, and differential pressure
switch.
Pneumatic technical data
Design: Prestressed metal bellows initiator Pressure ranges:
Pressure switch, connector P1: 25 800 kPa (0.25 8 bar) Vacuum
switch, connector P2: -20 -80 kPa (-0.2 -0,8 bar)
Differential pressure switch: connectors P1...P2: -95 800 kPa
(-0.95 8 bar) Hysteresis: Maximum 25 kPa (0.25 bar)
Electrical technical data
Switching current: 400 mA
-
Festo Tecsup DGP
Positioning slide
FP 1110, FP 1120
The positioning slide allows measurement of position and range
for proximity switches. Magnetic holders allow a vernier caliper
(Order no. 035653) to be mounted. This increases the accuracy of
measurements. When ordering the positioning slide on its own,
please also order 4 plug-in adapters (Order no. 323571) for
mounting on the aluminium profile plate.
Slide travel: 150 mm Graduation: 1 mm Angular scale: 90
Graduation: 2 Vernier scale: 0.2 mm Max. clamping thickness: 5
mm
Optical sensor with optical fiber connector, block-shaped
-
Festo Tecsup DGP
FP 1110
Type of light: Red light, 660 nm Switching output: PNP, normally
opened/closed, exclusive OR Nominal switching distance (with
fiber-optic cable ES, Order no. 150505): 80
mm Nominal switching distance (with optic-optic cable RT, Order
no. 150506): 30
mm Hysteresis (referred to nominal switching distance: 10 %
Reproducibility: 10 % Maximum switching current: 250 Hz Polarized,
short-circuit-proof: Yes
Optical sensor, Type M18
FP 1110
Type of light: Red light, 660 nm Switching output: PNP, normally
open Nominal switching distance: 150 mm Hysteresis (referred to
nominal switching distance):
-
Festo Tecsup DGP
Pressure manifold
FP 1130
The side connector of the pressure manifold has an L plug-in
coupling, the other connectors have self-closing plug-in
couplings.
Pressure range: 0 1600 kPa (0 16 bar)
Set of circular weights
FP 1130
Consisting of 10 disk weights at 1000 g each.
-
Festo Tecsup DGP
Pressure switch
FP 1130
Design: Pneumatic-electric signal converter Installation angle:
Any
Connections
Pneumatic: Internal thread R Electrical: Appliance socket to DIN
43650 Pressure range: 100 1200 kPa (1 12 bar) Overload pressure:
Short-term max. 5000 kPa (50 bar) Switching frequency: Max. 3.3 Hz
Reproducibility of switching point:
-
Festo Tecsup DGP
FP 1110
Switching voltage (reduced brightness of the LED at 18 V): 12 27
V AC/DC Switching point accuracy: 0.1mm Volume resistance: 100 m
Switching time (incl. bounce time):
-
Festo Tecsup DGP
Reflector unit for reflective lightbarrier
FP 1110
Diameter: 20 mm
Set of weights
FP 1120, FP 1130
Contains 5 weights from 20 to 500 g.
-
Festo Tecsup DGP
Spindle drive unit
FP 1120
The spindle drive unit with the geared motor (Order no. 080828)
implements one-dimensional motion. Electrical drive can be
controlled by a programmable logic controller or by the motor
controller (Order no. 162249). When ordering the spindle drive unit
alone, please also order adapters (Order no. 150519) for mounting
on the aluminium profile plate.
Max. displacement: 260 mm Attachment hole pattern Top: 4 x 5.3
(40 x 40 mm), with a counterbore on
both sides for socket hand screws M5 2 x 5.1 (36 x 15 mm)
Attachment hole pattern Sides: 2 x M5 (36 x 15 mm) Overall
dimensions: Approx. 110 x 420 x 30 mm Guide rod diameter: 12 mm
Spindle pitch : 3 mm
Ultrasonic proximity sensor,Type M18
FP 1110
Permissible operating voltage:24 V DC, 20 % Switching output:
PNP, normally open
-
Festo Tecsup DGP
Ultrasonic emitter frequency: 215 kHz Range: 100 200 mm
Hysteresis (referred to nominal value):
-
Festo Tecsup DGP
Air pressure reservoir
FP 1130
The accumulator can be used for the following applications:
Generation of static pressures with the aid of a one-way flow
control valve Generation of larger delay times in connection with
time-delay and flow control
valves Compensation of pressure fluctuations Use as reservoir in
the event of sudden pressure loss
Design: Brazed brass container Type of mounting: Spring clips,
retaining plate Volume: 400 ml Pressure range: 0 1600 kPa (0 16
bar)
Analog pressure sensor 1
-
Festo Tecsup DGP
FP 1130
Pressure range*: 0 1000 kPa (0 +10 bar) Max. perm. pressure:
1400 kPa (14 bar) Supply voltage VB: 12 30 V DC Voltage output: 0
10 V Current output: 0 20 mA Total error: 1 % of full-scale value
Max. measuring frequency: 100 Hz Electrical protection: Short
circuit proof, polarity reversal protection,
overvoltage-proof up to 50 V DC (short-term)
*The sensor provides a signal even if pressure
-
Festo Tecsup DGP
Backpressure switch
FP 1130
Bursting pressure: 200 kPa (2 bar) Switching frequency: Max. ca.
200 Hz Mech. service life: >108 switching cycles Switching
performance: Max. 50 mA at 24 V DC Measuring range: 120 800 Pa (1.2
8 mbar)
Capacitive proximity switch,Type M12
FP 1110
Switching output: PNP, normally open Nominal switching distance:
4 mm Hysteresis (referred to nominal switching distance): 3 15 %
Maximum switching frequency: 100 Hz Polarized, short-circuit-proof:
Yes
-
Festo Tecsup DGP
Deflecting arm force sensor
FP 1130
Measuring range: 0 5 N Overload: 130 % of measuring range Strain
gauge type: Foil SG Strain gauge resistance: 350 Max. permissible
supply voltage: 10 V
Connection unit, analogue
Permissible voltage range: 22 27 V DC Reference: GND 4 analogue
voltage inputs: Range: -10 V +10 V (max. 30 V), input
resistance:
200 k 4 analogue current inputs: Range: 0 20 mA (max. -4 +24
mA), input voltage:
max. 30 V 2 analogue outputs: Voltage: -10 +10 V,
short-circuit-proof, max. 30 V, fuse-
protected, current: max. 20 mA
Using an analogue cable (order no. 189551), the unit can also be
used as an analogue connection unit for the EduTrainer PLC.
-
Festo Tecsup DGP
Deflecting arm
FP 1120
Item to be measured for measuring compliance dependent on
load.
Counting unit
FP 1110
Input signal voltage: +15 +24 V Power consumption: 1.2 W
Accuracy:
Pulse output 100 pulses/s: 6 % Pulse output 1000 pulses/s: 3 %
Internal clock: 3 %
-
Festo Tecsup DGP
Diffuse reflective optical sensor,block-shaped
FP 1110
Type of light: IR, 880 nm Switching output: PNP, normally
open/closed, exclusive OR Nominal switching distance (adjustable):
360 mm Hysteresis (at nominal switching distance): 2 15 %
Reproducibility: 10 % Maximum switching frequency: 250 Hz
Polarized, short-circuit-proof: Yes
Gear motor
FP 1120
The motor drives for the spindle drive unit (Order no. 080824)
and can be used in combination with the assembly kit DE (Order no.
150539) as a rotary drive. Includes mounting.
-
Festo Tecsup DGP
Rated current: 0.3 A Output rating: 3.31 W Nominal speed: 158
min-1 Motor starting torque: 60.75 Ncm Nominal torque: 19 Ncm
Inductive analog distance sensor
FP 1120
Permissible operating voltage:15 30 V DC Voltage output: 0 10 V
Load resistance: 4.7 k Current output: 0 20 mA Load resistance: 500
Measuring range: 3 8 mm Max. measuring frequency: 80 Hz Temperature
error: 5 % of full-scale value Linearity error: 3 % of full-scale
value Reproducibility: 2 % of full-scale value Polarized,
short-circuit-proof: Yes
-
Festo Tecsup DGP
Inductive proximity sensor,Type M12
FP 1110
Switching output: PNP, normally open Nominal switching distance
(for S 235 JR): 4 mm Hysteresis (referred to nominal switching
distance): 1 15 % Maximum switching frequency: 400 Hz Polarized,
short-circuit-proof: Yes
Inductive proximity sensor,Type M18
FP 1110
Switching output: PNP, normally open Nominal switching distance
(for S 235 JR): 5 mm Hysteresis (referred to nominal switching
distance): 1 15 % Maximum switching frequency: 500 Hz Polarized,
short-circuit-proof: Yes
-
Festo Tecsup DGP
Linear potentiometer, 300 mm stroke
FP 1120
Suitable for slide unit (Order no. 80824). Assembly with
mountable vernier caliper (Order no. 150536) with the aid of the
assembly set ( Order no. 150540).
Permissible operating voltage*: 13 30 V DC Potentiometer
resistance: 5 k Electrical pick-up length: 304 mm Output voltage*:
0 10 V DC Max. linearity error: 0.07 % of full-scale value
Resolution and reproducibility: 0.01 mm Polarity protection: Yes
Adjustment speed: 10 m/s Adjustment acceleration: 200 m/s2
*Applicable for potentiometer including impedance converter.
Mountable vernier caliper
FP 1120
The mountable vernier caliper with digital display (Order no.
150540) can be mounted on the positioning slide (Order no. 080824).
Delivery including battery (Type CR 2032, Li-Mn 3 V).
Measuring path: 286 mm Measuring accuracy: 0,03 mm Resolution
and repeat accuracy: 0.01 mm
-
Festo Tecsup DGP
Speed:
-
Festo Tecsup DGP
Hysteresis: 0.1 1.5 mm Maximum switching frequency: 1000 Hz
Polarized, short-circuit-proof: Yes
On-off valve with filter regulating valve
TP 101, BIBB-P, TP 201, TP 301 (until 2004), TP 220
Filter regulator with pressure gauge, on-off valve, quick
push-in connections and quick couplings, mounted on a swivel
support.
The filter with water separator removes dirt, pipe sinter, rust
and condensate. The pressure control valve regulates the supply air
pressure to the set operating pressure and compensates pressure
fluctuations. The filter bowl has a condensate drain valve. The
on-off valve pressurises and vents the entire control system. The
3/2-way valve is actuated by a rotary knob.
Type: Sintered filter with water trap, piston regulating valve
Standard nominal flow rate*: 750 l/min Input pressure: max. 1600
kPa (16 bar) Working pressure: max. 1200 kPa (12 bar) Grade of
filtration: 40 m Condensate quantity: 14 cm3 Connector: G 1/8,
QS-6, for plastic tubing PUN 6 x 1
*Input pressure: 1000 kPa (10 bar), operating pressure: 600 kPa
(6 bar), differential pressure: 100 kPa (1 bar).
-
Festo Tecsup DGP
One-way flow control valve
TP 101, TP 102, BIBB-P, TP 111, FP 1130 (until 2004)
The one-way flow control valve is a combination of flow control
valve and a nonreturn valve. The cross-section of the restrictor
can be set by means of a knurled screw.
Design: Combined flow control valve Pressure range: 30 1000 kPa
(0.3 10 bar) Nominal flow rate
in flow control direction: 0 180 l/min in open direction:
180/110 l/min (Throttle valve open/closed)
Optical analog distance sensor
FP 1120
Current output: 4 20 mA Measuring range with fiber-optic cable
(adjustable via potentiometer): 8 40
mm Response time:
-
Festo Tecsup DGP
One-way light barrier, receiver
FP 1110
Type of light: IR, 880 nm Switching output: PNP, normally
open/closed, exclusive OR Nominal switching distance: 10 m
Operational switching distance (adjustable): 0 8.1 m Hysteresis
(referred to nominal switching distance):
-
Festo Tecsup DGP
Optical fiber for diffuse reflective optical sensor
FP 1110
Diameter of fiber-optic cable: 1 mm Length: 1000 mm Bending
radius: >25 m Nominal switching distance: with Order no. 167
065: 30 mm
One-way flow control valve
TP 101, TP 102, BIBB-P, TP 111, FP 1130 (from 2005)
The one-way flow control valve is a combination of a flow
control valve and a nonreturn valve. The cross-section of the
restrictor can be set by means of a knurled screw.
Design: Combined flow control valve Pressure range: 30 1000 kPa
(0.3 10 bar) Nominal flow rate
in flow control direction: 0 180 l/min in open direction:
180/110 l/min (Throttle valve open/closed)
-
Festo Tecsup DGP
Optical fiber for one-way light barrier
FP 1110
Diameter of fiber-optic cable: 1 mm Length: 1000 mm Bending
radius: >25 m Nominal switching distance: with Order no. 167
065: 80 mm
Force sensorMotor controllerMeasuring bridge
amplifierNon-contact inductive-magnetic proximity
sensorPneumatic-electrical converterPositioning slideOptical sensor
with optical fiber connector, block-shapedOptical sensor, Type
M18Pressure manifoldSet of circular weightsPressure switchReed
switchSet of test objectsReflector unit for reflective
lightbarrierSet of weightsSpindle drive unitUltrasonic proximity
sensor,Type M18Plug-in adapter setFunction
generator/counter/stopwatchAir pressure reservoirAnalog pressure
sensor 1Analog pressure sensor 2Backpressure switchCapacitive
proximity switch,Type M12Deflecting arm force sensorConnection
unit, analogueDeflecting armCounting unitDiffuse reflective optical
sensor,block-shapedGear motorInductive analog distance
sensorInductive proximity sensor,Type M12Inductive proximity
sensor,Type M18Linear potentiometer, 300 mm strokeMountable vernier
caliperInfrared light barrier, block-shapedNon-contact
inductive-magnetic proximity sensorOn-off valve with filter
regulating valveOne-way flow control valveOptical analog distance
sensorOne-way light barrier, receiverOne-way light barrier,
transmitterOptical fiber for diffuse reflective optical
sensorOne-way flow control valveOptical fiber for one-way light
barrier