This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Heating & CoolingIndoor unIts FBQ35C FBQ50C FBQ60C
Capacitycooling nom. kW 3.40 3 5.0 3 5.70 3
heating nom. kW 4.00 4 5.50 4 7.00 4
Power inputcooling nom. kW 1.06 1.65 1.75
heating nom. kW 1.14 1.61 2.05
EER 3.21 3.03 3.26COP 3.51 3.42 3.41
Energy label cooling/heating A/B B/B A/B
Annual energy consumption kWh 530 825 875
Dimensions uni t heightxwidthxdepth mm 300x700x700 300x700x700 300x1,000x700
Weight unit kg 25 34
Casingcolour Unpainted
material Galvanised steel
Fan - Air ow ratecooling high/low m³/min 16/11 18/15
heating high/low m³/min 16/11 18/15
Fan - External static pressure high/nom. Pa 100/30
Sound pressurelevel
cooling high/low dBA 37/29
heating high/low dBA 37/29
Sound power level cooling high dBA 63 57
Power supply phase/frequency/voltage Hz/V 1~/50-60/220-240/220
Pipingconnections
liquid OD mm ø6.35 ø9.52
gas OD mm ø9.52 ø12.7 ø15.9
drain OD mm øVP20 (OD26, ID20)
Decoration panel
model BYBS45DJW1 BYBS71DJW1
colour White (10Y9/0.5)
dimensions heightxwidthxdepth mm 55x800x500 55x1,100x500
weight kg 3.5 4.5
(1) Energy label: scale from A (most ecient) to G (less ecient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent
piping length: 7.5m; level dierence: 0m (4) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level dierence: 0m (5) The sound pressure values are mentioned for a unit ins talled with rear suction.
outdoor unIts rXs35G rXs50G rXs60F
Dim ension s unit heightxwidthxdepth mm 550x765x285 735x825x300 735x903x300Weight unit kg 34 48
Compressor type Hermetically sealed swing Hermetically sealed scroll Herm eticall y seal ed scroll
Refrigerant type R-410A R-410A
Power supply phase/frequency/voltage Hz/V 1~/50/220-240 3N~/50/400
Pipingconnections
additional refrigerant charge kg/m See installation manual See installation manual
level dierenceIU - OU max. m 30 30.0
IU - IU max. m 0.5 0.5
piping length system equivalent m 70 75 75
(1) Energy label: scale from A (most ecient) to G (less ecient) (2) Annual energy consumption: based on average use of 500 runn ing hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent
piping length: 7.5m; level dierence: 0m (4) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level dierence: 0m (5) The sound pressure values are mentioned for a unit installed with rear suction.
Indoor unIts FBQ71C FBQ100C FBQ125C FBQ140C FBQ100C FBQ125C FBQ140C
Sound power level cooling high dBA 57 61 66Power supply phase/frequency/voltage Hz/V 1~/50-60/220-240/220
Pipingconnections
liquid OD mm ø9.52gas OD mm ø15.9drain OD mm ø26
Decoration panel
model BYBS71DJW1 BYBS125DJW1colour White (10Y9/0.5)
dimensions heightxwidthxdepth mm 55x1,100x500 55x1,500x500weight kg 4.5 6.5
(1) Energy label: scale from A (most ecient) to G (less ecient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent
piping length: 7.5m; level dierence: 0m (4) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level dierence: 0m (5) The sound pressure values are mentioned for a unit installed with rear suction.
Power inputcooling nom. kW 2.75 3.75heating nom. kW 2.49 3.70
EER 2.58 2.67
COP 3.21 3.03Annual energy consumption kWh 1,375 1,875Energy label cooling/heating E/C D/DDim ension s unit heightxwidthxdepth mm 300x1,000x700 300x1,400x700Weight unit kg 34 45
Casingcolour Unpaintedmaterial Galvanised steel
Fan - Air ow ratecooling high/low m³/min 18/15 32/23heating high/low m³/min 18/15 32/23
Fan - External static pressure high/nom. Pa 100/30 100/40
Sound power level cooling high dBA 57 61Power supply phase/frequency/voltage Hz/V 1~/50-60/220-240/220
Piping connectionsliquid OD mm ø9.52gas OD mm ø15.9drain OD mm ø26
Decoration panel
model BYBS71DJW1 BYBS125DJW1colour White (10Y9/0.5)
dimensions heightxwidthxdepth mm 55x1,100x500 55x1,500x500weight kg 4.5 6.5
(1) Energy label: scale from A (most ecient) to G (less ecient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nomina l conditions) (3) Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent
piping length: 5m; level dierence: 0m (4) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level dierence: 0m (5) The sound pressure values are mentioned for a unit installed with rear suction.
OUDOOR»UNIS RQ71BV3 RQ100BV3
Dim ension s unit heightxwidthxdepth mm 770x900x320 1,170x900x320Weight unit kg 84 103
D imensions unit heightxwidthxdepth mm 300x1,000x700 300x1,400x700
Weight unit kg 34 45
Casingcolour Unpainted
material Galvanised steel
Fan - Air ow ratecooling high/low m³/min 18/15 32/23 39/28
heating high/low m³/min 18/15 32/23 39/28
Fan - External static pressure high/nom. Pa 100/30 100/40 100/50
Sound pressurelevel
cooling high/low dBA 37/29 38/32 40/33
heating high/low dBA 37/29 38/32 40/33
Sound power level cooling high dBA 57 61 66
Power supply phase/frequency/voltage Hz/V 1~/50-60/220-240/220
Piping connections
liquid OD mm ø 9.52
gas OD mm ø15.9
drain OD mm ø 26
Decoration panel
model BYBS71DJW1 BYBS125DJW1colour White (10Y9/0.5)
dimensions heightxwidthxdepth mm 55x1,100x500 55x1,500x500
weight kg 4.5 6.5
(1) Energy label: scale from A (most ecient) to G (less ecient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent
piping length: 7.5m (horizontal); level dierence: 0m (4) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level dierence: 0m (5) The sound pressure values are mentioned for a unit installed with rear suction.
OUDOOR»UNIS RQ71BW1 RQ100BW1 RQ125BW1
Dim ension s unit heightxwidthxdepth mm 770x900x320 1,170x900x320Weight unit kg 83 101 108
Naamloze Vennootschap - Zandvoordestraat 300 B-8400 Oostende - Belgium - www daikin eu - BE 0412 120 336 - RPR Oostende E C P E N 1 0 - 1 5 2 • X X X • 0 5 / 1 0 • C o p y r i g
h t D a i k i n
T h e p r e s e n t p u b l i c a t i o n s u p e r s e d e s
E C P E N 1 0 - 1 0 2
P r i n t e d o n n o n - c h l o r i n a t e d p a p e r . P
r e p a r e d b y L a M o v i d a , B e l g i u m
R e s p o n s i b l e E d i t o r : D a i k i n E u r o p e N . V . , Z a n d v o o r d e s t r a a t 3 0 0 , B - 8 4 0 0 O o s t e n d e The present leaflet is drawn up by way of information only and does not constitute an offer binding upon
Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge.
No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular
purpose of its content and the pro ducts and services presented therein. Specifications are subject to change
without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in
the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is
copyrighted by Daikin Europe N.V.
Daikin’s unique position as a manufacturer of air
conditioning equipment, compressors and refrigerants
has led to its close involvement in environmental issues.
For several years Daikin has had the intention to become
a leader in the provision of products that have limited
impact on the environment. This cha llenge demands the
eco design and development of a wide range of products
and an energy management system, resulting in energy
conservation and a reduction of waste.
Daikin Europe N.V. participates in the Eurovent
Certification Programme for Air Conditioners (AC),
Liquid Chilling Packages (LCP) and Fan Coil Units (FC);
the certified data of certified models are listed in the
Eurovent Directory. Multi units are Eurovent certified for