FB - 2 - 003 Upstand detail under vertical cladding...BS EN 12691-A ≥1000 ≥1000 Resistance to Static Loading kg BS EN 12730 -A ≥15 ≥15 Low Temperature Flex °C -20 -20 BSEN
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Polyglass GB Ltd, Unit 1, Electrium Point, Ashmore Lake Way, Willenhall, West Midlands, WV12 4HD. T: 01902 637422 F: 01902 637459
1. Deck2. Vapour check or barrier3. Insulation fully bonded type4. Underlay5. Cap sheet6. Detail cap sheet7. Aluminium flashing8. Rooflight9. Rooflight upstand
FB - 2 - 023 Rooflight detail
Product Data Sheet
High Performance Elastomeric Membrane Cap Sheet March 2018
Description
Roof Flex Pro S6 Mineral Cap Sheet is a range of polyester based
elastomeric roofing membranes, coated with a high quality polymer
modified SBS bitumen coating. Roof Flex Pro S6 is available in two
versions, one for installation by the traditional pour & roll method and
one by torch-on application. The underside of the torch-on version is
protected by Polyflam a special polyethylene film which melts upon
torching and the pour & roll version is finished with a fine sand surface.
In both versions the top surface is protected by a uniform layer of slate
chippings and has a lateral selvedge for overlapping making
application fast and secure. Roof Flex Pro S6 membranes provide
reliable and effective flat roof waterproofing, combining the qualities of
excellent performance, good handling characteristics and economy.
Roof Flex Pro S6 membranes exhibit excellent dimensional and
mechanical stability making them suitable as part of a built-up system,
or as a refurbishment overlay to existing asphalt or selected compatible
surfaced membranes. Features and Benefits:-
• Available in both torch-on and pour & roll applications • Strong rot resistant polyester base • Flexible SBS elastomeric modified bitumen • Low temperature flexibility -20°C • Cost effective performance • 20 year System Warranty available
Dimensions & Weights Roof Flex Pro S6 Mineral Pour & Roll Roof Flex Pro S6 Mineral Torch-On
Roll Weight kg 40 40 Weight kg/m2 4 5 Roll Length m 10 8 Roll Width m 1 1 Thickness mm N.A. N.A. Selvedge Width mm 75 75 Product Components
Whilst every care is taken to see that the information given in this literature is correct and up to date it is not intended to form part of any
contract or give rise to any collateral liability, which is hereby specifically excluded. Intending purchasers of our materials should therefore verify
with the company whether any changes in our specification or application details or otherwise have taken place since this literature was issued.
Company Registration No. SC182195 - Registered Office: 7 Tollpark Road, Wardpark East, Cumbernauld, North Lanarkshire, G68 0LW
Product Data Sheet
High Performance Elastomeric Polyester Underlay February 2018
Description Roof Flex Pro S6 Underlay is a range of polyester based underlays,
coated with a high quality polymer modified SBS bitumen coating. The
underside of Roof Flex Pro S6 Underlay is protected by Polyflam a
special polyethylene film which melts upon torching.
Roof Flex Pro S6 TT Underlay is protected by Polyflam on both the top
and underside thus providing a bitumen rich surface when torching
applying the Flexo S6 cap sheet.
The upper face of Roof Flex Pro S6 TS Underlay is finished with fine
sand allowing the use of suitably approved adhesives to bond
insulation, etc. to the surface.
Roof Flex Pro S6 torch-on membranes provide reliable and effective flat
roof waterproofing, combining the qualities of excellent performance,
good handling characteristics and economy. Roof Flex Pro S6
membranes exhibit excellent dimensional and mechanical stability
making them suitable as part of a built-up system, or as a refurbishment
overlay to existing asphalt or selected compatible surfaced membranes.
Features and Benefits:- • Torch-on application • Strong rot resistant polyester base • Flexible SBS elastomeric modified bitumen • Low temperature flexibility -20 °C • Cost effective performance
Dimensions & Weights R F P S6 TT 3mm R F P S6 TS 4mm R F P S6 TS 3Kg
Roll Weight kg 32 36 20
Weight kg/m2 N.A. 2 3 Roll Length m 8 8 10 Roll Width m 1 1 1 Thickness mm. 3 4 N.A. Selvedge Width mm N.A. N.A. N.A. Product Components
Base Polyester Polyester Polyester
Typical Performance
Tensile Strength (MD) Nf50mm 500 500 500
Tensile Strength (TD) Nf50mm 400 400 400
BSEN 12311: 2000
Elongation (MD) % 35 35 35
Elongation (TD) % 35 35 35
BSEN 12311: 2000
Low Temperature Flex °C -20 -20 -20
BSEN 1109: 2000
Roof Flex Pro S6
Polyester Underlay
Product Information
Roof Flex Pro S6 Polyester Underlay Sand
Surfaced Finish - Incorporates a non-woven
polyester base, coated with SBS modified
bitumen, providing a very high degree of
strength and durability can be used as a
high performance underlay or as a capsheet
where the surface will be protected by
walkway tiles, chippings or other approved
surface protection.
Application Roof Flex Pro S6 torch-on roofing
membranes should be installed in
accordance with 8217: 2005, Code of
Practice for reinforced bitumen membranes
for roofing, and to Polyglass specifications
and recommendations. The application
should follow the general good practices for
torch-applied membranes. Care must be
taken when applying Flexo S6 torch-on
membranes in close proximity to
combustible materials, decorative coatings
and heat sensitive materials.
Apply roof Flex Pro S6 torch-on roofing by
melting the heat dispersible backing and
coating to create a molten flow in front of the
roll. The flame of the torch should be applied at
the low point where the roll meets the underlay.
As the film and bitumen melts, roll the roofing
forward. Side joints in the sheets should be
fully bonded and formed using the 75mm
selvedge. NB. A bead of bitumen must exude
from all lap joints to ensure a seal. Other Products Full product literature, health & safety and
technical sheets are available as downloads or
on request from our Head Office, detailed
below.
Roof Flex Pro Roofing Systems are only available to Approved Installers
Polyglass GB Ltd
Head Office & Sales Office 1 Electrium Point, Ashmore Lake Way,Willenhall.West Midlands WV12 4LF
Whilst every care is taken to see that the information given in this literature is correct and up to date it is not intended to form part of any
contract or give rise to any collateral liability, which is hereby specifically excluded. Intending purchasers of our materials should therefore verify
with the company whether any changes in our specification or application details or otherwise have taken place since this literature was issued.
Company Registration No. SC182195 - Registered Office: 7 Tollpark Road, Wardpark East, Cumbernauld, North Lanarkshire, G68 0LW
Product Data Sheet
High Performance Vapour Control Layers February 2018
Description Roof Flex Pro VC is a range of high performance, aluminium cored
vapour control layers (VCL’s) coated with a high quality polymer
modified bitumen coating. The underside of Roof Flex Pro TT & Roof
Flex Pro TS are protected by Polyflam a special polyethylene film
which melts upon torching. In the Roof Flex Pro TT version the top
surface is also protected by a layer of Polyflam providing a bitumen rich
surface. The top surface of Roof Flex Pro TS has a coating of fine sand
thereby enabling the use of bitumen or Roof Flex Pro polyurethane
adhesive to bond insulation to the upper face of the VCL. Roof Flex Pro
SA is a self-adhesive membrane manufactured using ADESO ®
technology and can be incorporated into a completely flame free self-
adhesive roofing system.
Features and Benefits:-
• Torch-on and Self-Adhesive applications available
• Aluminium core stops ingress of water vapour and damage to
roof construction.
• Durable polymer modified bitumen coating.
• Cost effective performance.
• Part of a complete package of waterproofing components.
Dimensions & Weights Roof Flex Pro TT Roof Flex Pro TS Roof Flex Pro SA
Roll Thickness kg 3mm 3mm 2mm
Roll Length m 8m 10m 15m
Roll Width m 1m 1m 1m
Product Components
Base Glassfibre/Aluminium Glassfibre/Aluminium Glassfibre/Aluminium
Whilst every care is taken to see that the information given in this literature is correct and up to date it is not intended to form part of any
contract or give rise to any collateral liability, which is hereby specifically excluded. Intending purchasers of our materials should therefore verify
with the company whether any changes in our specification or application details or otherwise have taken place since this literature was issued.
Company Registration No. SC182195 - Registered Office: 7 Tollpark Road, Wardpark East, Cumbernauld, North Lanarkshire, G68 0LW